Notice: No part of this publication may be
reproduced or transmitted in any form or by
any means, electronic or mechanical, including
photocopying and recording, or stored in a
database or retrieval system for any purpose
without the express written permission of
Hitachi Data Systems Corporation (hereinafter
referred to as “Hitachi Data Systems”).
Hitachi Data Systems reserves the right to
make changes to this document at any time
without notice and assumes no responsibility
for its use. Hitachi Data Systems products and
services can only be ordered under the terms
and conditions of Hitachi Data Systems'
applicable agreements. All of the features
described in this document may not be
currently available. Refer to the most recent
product announcement or contact your local
Hitachi Data Systems sales office for
information on feature and product
availability.
This document contains the most current
information available at the time of
publication. When new and/or revised
information becomes available, this entire
document is updated and distributed to all
registered users.
ii
Hitachi Data Systems is a registered
trademark and service mark of Hitachi, Ltd.,
and the Hitachi Data Systems design mark is a
trademark and service mark of Hitachi, Ltd.
Other company and product names mentioned
herein are trademarks of their respective
companies. Mention of third-party products is
for informational purposes only and
constitutes neither an endorsement nor a
recommendation. Hitachi Data Systems
assumes no responsibility with regard to the
performance or use of these products.
Congratulations on your new Hitachi Simple Modular Storage 100
array.
Your Hitachi Simple Modular Storage 100 is a powerful Internet
Small Computer System Interface (iSCSI) solution that provides
a range of benefits, features, and economics from its ability to
use familiar, proven, and widespread networking technologies
like Internet Protocol (IP) and Ethernet for storage solutions. Y our
Hitachi Simple Modular 100 is designed for businesses that want
to improve the reliability, availability, serviceability, and
performance of their storage systems.
This guide will assist you in installing, configuring, and
maintaining your Hitachi Simple Modular Storage 100.
This preface includes the following information:
•Document Revision Level
•Changes in this Revision
•Safety and Warnings
•Environmental Notices
•Intended Audience
•Product Version
•Supplemental Documentation
•Document Organization
•Related Documents
•Document Conventions
•Convention for Storage Capacity Values
•Getting Help
•CommentsNotice: The use of the Hitachi Simple Modular Storage and all
Hitachi Data Systems products is governed by the terms of your
agreement(s) with Hitachi Data Systems.
Prefacevii
Hitachi Simple Modular Storage 100 User’s Guide
Document Revision Level
This section provides a history of the revision changes to this document.
•
RevisionDateDescription
MK-97DF8061September 2007Initial Release
MK-97DF8061-01November 2007Revision 1, supersedes and replaces MK-
Changes in this Revision
This section provides a list of changes from the previous revision to this one.
•Not applicable (initial release)
Safety and Warnings
This document uses the following symbols to draw your attention to certain
information.
•
SymbolMeaningDescription
TipTips provide helpful information, guidelines, or suggestions for
performing tasks more effectively.
•
NoteNotes emphasize or supplement important points of the main
text.
•
CautionCautions indicate that failure to take a specified action could
result in damage to the software or hardware.
•
WARNINGWarnings indicate that failure to take a specified action could
result in loss of data or serious damage to hardware.
•
DANGERDanger warns users of possible injury or death if instructions
are not followed.
•
•cv
•
ELECTRIC
SHOCK
HAZARD!
Electrostatic
Sensitive
This symbol warns users of electric shock hazard. Failure to
take appropriate precautions such as not opening or touching
hazardous areas of the equipment could result in injury or
death.
The ESD symbol warns users that the equipment is sensitive
to electrostatic discharge (ESD) and could be damaged if users
do not take appropriate precautions such as using a grounded
wrist strap when touching or handling the equipment.
97DF8061-00.
viiiPreface
Hitachi Simple Modular Storage 100 User’s Guide
Environmental Notices
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment.This
equipment generates, uses, and can radiate radio fre quency energy and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference, in which case
users will be required to correct the interference at their own expense.
Intended Audience
This document is intended for users who are involved in installing,
configuring, and operating your Hitachi Simple Modular Storage 100.
To use this document, you should have a working knowledge of the
following:
•A basic understanding of data storage concepts
•Familiarity with system installation and configuration terminology
FCC Notice
Federal Communications Commission
•An understanding of the host operating system supported by your
Hitachi Simple Modular Storage 100
Product Version
This document revision applies to Hitachi Simple Modular Storage
microcode versions 1810/A and higher.
Supplemental Documentation
Release Notes. Please read the Release Notes before installing and/or
using this product. The Release Notes are located on the installation CD).
They may contain requirements and/or restrictions that are not fully
described in this document. The Release Notes may also contain updates
and/or corrections to this document.
Document Organization
The following table provides an overview of the contents and organization
of this document. Click the chapter title in the first column to go to that
chapter. The first page of every chapter or appendix contains a brief list of
the contents of that section of the manual, with links to the pages where
the information is located.
Prefaceix
Hitachi Simple Modular Storage 100 User’s Guide
•
Chapter/Appendix
Title
Chapter 1, IntroductionProvides a brief overview of your Hitachi Simple Modular
Storage 100.
Chapter 2, Identifying
Hardware Components
Chapter 3, Installing
Your Array
Chapter 4, Maintaining
Your Array
Chapter 5,
Troubleshooting
Appendix A, Upgrading
Firmware
Appendix B, Factory
Default Settings
Appendix B,
Specifications
Describes the hardware components on your Hitachi Simple
Modular Storage 100.
Provides instructions for installing your Hitachi Simple
Modular Storage 100.
Describes how to install spares and care, transport, and
store your Hitachi Simple Modular Storage 100. An overview
of migrating data is also provided.
Provides information for identifying and resolving problems.
Describes how to upgrade your Hitachi Simple Modular
Storage 100 firmware.
Shows your Hitachi Simple Modular Storage 100 factory
default configuration.
Lists your Hitachi Simple Modular Storage 100
specifications.
Description
GlossaryDefines the acronyms and special terms used in this
document.
IndexProvides a detailed and linked list of topics in this manual.
•Hitachi Simple Modular Storage 100 Auto Migration Assistant Guide
(MK-96DF8066)
•Hitachi Storage Navigator Modular 2 online help
•
xPreface
Hitachi Simple Modular Storage 100 User’s Guide
Document Conventions
The following table describes the typographic conventions used in this
document.
ConventionDescription
BoldIndicates text on a window, other than the window title, including
menus, menu options, buttons, fields, and labels.
ItalicIndicates a variable, which is a placeholder for actual text provided
by the user or system. Example: copy source-file target-file.
Note: Angled brackets (< >) are also used to indicate variables.
screen/codeIndicates text that is displayed on screen or entered by the user.
< > angled
brackets
[ ] square
brackets
{ } bracesIndicates required or expected values.
| vertical bar Indicates that you have a choice between two or more options or
underlineIndicates the default value.
Indicates a variable, which is a placeholder for actual text provided
by the user or system. Italic font is also used to indicate variables.
Indicates optional values.
arguments.
Convention for Storage Capacity Values
Storage capacity values for hard disk drives (HDDs) in Hitachi Data
Systems’ storage products are calculated based on the following values:
•1 KB = 1,000 bytes
2
•1 MB = 1,000
•1 GB = 1,000
•1 TB = 1,000
bytes
3
bytes
4
bytes
For further information on Hitachi Data Systems products and services,
please contact your Hitachi Data Systems account team, or visit Hitachi
Data Systems online at http://www.hds.com.
Prefacexi
Hitachi Simple Modular Storage 100 User’s Guide
Getting Help
If you have questions after reading this guide, contact an HDS authorized
service provider or visit the HDS support website: http://support.hds.com
Support Contact Information
If you purchased this product from an authorized HDS reseller, contact that
reseller for support. For the name of your nearest HDS authorized reseller,
refer to the HDS support web site for locations and contact information.
To contact the Hitachi Data Systems Support Center, please visit the HDS
website for current telephone numbers and other contact information.
http://support.hds.com
Please provide at least the following information about the problem:
•Product name, model number, part number (if applicable) and serial
number
•System configuration, including names of optional features installed,
host connections, and storage configuration such as RAID groups and
LUNs
•Operating system name and revision or service pack number
•The exact content of any error message(s) displayed on the host
system(s)
•The circumstances surrounding the error or failure
•A detailed description of the problem and what has been done to try to
solve it
•Confirmation that the HDS Hi-Track remote monitoring feature has
been installed and tested.
•
NOTE: To help improve the quality of our service and support, your calls
may be recorded or monitored.
HDS Support Web Site
The following pages on the HDS support web site contain other further help
and contact information:
•Home Page: http://support.hds.com
xiiPreface
Hitachi Simple Modular Storage 100 User’s Guide
Comments
Your comments and suggestions to improve this document are greatly
appreciated. When contacting HDS, please include the document title,
number, and revision. Please refer to specific section(s) and paragraph(s)
whenever possible.
• E-mail: doc.comments@hds.com
•Mail: Technical Writing, M/S 35-10
Thank you! (All comments become the property of Hitachi Data Systems
Corporation.)
Hitachi Data Systems
10277 Scripps Ranch Blvd.
San Diego, CA 92131
Prefacexiii
Hitachi Simple Modular Storage 100 User’s Guide
xivPreface
Hitachi Simple Modular Storage 100 User’s Guide
1
Introduction
This chapter provides an overview of your Hitachi Simple Modular
Storage 100 array. This chapter covers the following key topics:
Overview
Product Description
Key Features
Clear Customer Benefits
Storage Features
Supported Host Operating Systems
Overview
Supported Topologies
Concepts and Terms
Your Hitachi Simple Modular Storage 100 is a cost-effective,
easily deployable, and fully integrated iSCSI storage solution that
allows servers to connect to storage networking using Internet
SCSI (iSCSI).
iSCSI is a standard for linking data storage devices over a
network and transferring data by carrying SCSI commands over
IP networks. On your Hitachi Simple Modular Storage 100, iSCSI
disks reside on an expandable RAID-protected volume, but
appear to a client machine as a local SCSI drive. Connectivity to
the iSCSI disk is established using a software package or PCI card
known as an iSCSI initiator, which must be installed on a client
machine. The initiator recognizes your Hitachi Simple Modular
Storage 100 as a “target portal” and an iSCSI disk as a “target.”
Introduction1–1
Hitachi Simple Modular Storage 100 User’s Guide
Hitachi Data Systems has qualified a number of iSCSI initiators, network
interface cards (NICs), and other devices to interoperate with your Hitachi
Simple Modular Storage 100. For the latest information about supported
versions and models of iSCSI software and hardware products, please refer
to the Hitachi Feature and Interoperability Reports at https://
Your Hitachi Simple Modular Storage 100 is available in single- and dualcontroller configurations:
•Arrays with a single controller provide two iSCSI data ports and 1 GB of
cache.
•Arrays with dual controllers provide four iSCSI data ports and 2 GB of
cache.
All iSCSI data ports support 1 Gbps full-duplex Ethernet (1000Base-T)
speeds using standard Category 5e or Category 6 Ethernet Local Area
Network (LAN) cables.
Both configurations support six, eight, or 12 Serial Adv anced Technology
Attachment (SATA) or Serial At tached SCSI (SAS) drives. SATA and SAS
drives cannot be mixed in the same array.
Key Features
•1 Gbps full-duplex Ethernet (1000Base-T) iSCSI data ports using
standard Category 5e or Category 6 cables
•Available in single- and dual-controller configurations
•1 GB cache per controller
•Provides up to 9 TB of storage
•Supports up to 255 host connections via iSCSI switch
•RAID 6 support allows for two simultaneous drive failures without data
loss or downtime
•Modular design supports up to 12 SATA or SAS drives
•Modular design allows two spare drives to be added without having to
power-down the array
•iSNS for discovery of devices on the iSCSI network
•Redundant (2) power supplies and fans
•Web-based management software featuring a point-and-click GUI and
step-by-step wizards that simplify your ability to configure, provision,
and manage storage on an as-needed basis
•Array can be configured to send email alerts when a serious event,
such as a failure, occurs
1–2Introduction
Hitachi Simple Modular Storage 100 User’s Guide
Clear Customer Benefits
•Designed from the ground up as a reliable, cost-effective storage
solution that is easy for users to install and maintain, without requiring
storage expertise
•Proven, third-generation SAN storage technology that delivers
enterprise features and remote data protection to small-to-midsize
businesses
•High availability with RAID 6 protection to safeguard critical data assets
•Installs in minutes, with no single point of failure
•Scalable architecture allows up to two spare drives to be added while
the array is running
•Built-in redundancy provide continuous access to data with dual paths
from servers to disk drives, and fully redundant power
•Complete suite of quick-start guides, user guides, and Storage
Navigator Modular 2 online help ensure you get the most out of your
Hitachi Simple Modular Storage 100
Storage Features
Y our Hitachi Simple Modular Storage 100 may come with several preinstalled storage features that enable you to simplify your storage tasks.
The following sections describe these storage features.
User manuals for the features described in the following sections can be
found as PDF files on the documentation CD supplied with your Hitachi
Simple Modular Storage 100. If your storage feature requires a license key
or code before it can be used, please refer to the Storage Navigator Modular
2 online help for instructions.
NOTE: Some of the features described in the following sections may not
be available at the time your Hitachi Simple Modular Storage 100 was
shipped. For more information, please refer to the Hitachi Feature and
Interoperability Reports at https://extranet.hds.com/http://
hifirerw.hds.com/HiFire/GuestRegister.jsp.
Holistic Backup and Recovery
Features
•ShadowImage™ In-system Replication software
•Hitachi Copy-on-Write Snapshot software
From accidental file deletions to natural disasters, all kinds of data
calamities threaten business operations and escalate the demands for
better business practices. The challenge facing most companies is how to
minimize the lost revenue and operating expenses these disasters cause.
No matter what your company does or what size it is, business continuity
matters to you. Y our ability to recove r data and resume operations depend
completely on what you do before the disaster.
Introduction1–3
Hitachi Simple Modular Storage 100 User’s Guide
Data backups offer critically important benefits, as long as backups are
done correctly and consistently. ShadowImage In-system Replication
software offers nondisruptive, high-speed data backup operations on a copy
of up-to-date production data, while critical applications run unaffected and
businesses remain online.
Traditional downtime recovery processes can be labor-intensive and span
several hours, during which production data is unavailable. Copy-on-Write
Snapshot software rapidly creates point-in-time copies of any data volume
within your Hitachi Simple Modular Storage 100 without impacting
application service or performance levels. Because snapshots store only the
changed data blocks, the storage capacity required for each copy is
substantially smaller than the source volume, providing significant savings
over full cloning methods. The Copy-on- Write Snapshot copies are fully
read/write compatible, simplifying rapid data restores, data mining and
warehousing, and nondisruptive backup and maintenance procedures.
•
NOTE: ShadowImage In-system Replication software and Copy-on-Write
Snapshot software are available only for Hitachi Simple Modular Storage
100s equipped with dual controllers.
LUN Management
Security
Feature
•LUN Manager
A Logical Unit Number (or LUN) refers to either an entire physical disk, or a
subset of a larger physical disk or disk volume. LUNs represent the
“virtualization layer” between the physical disk/volume and applications. A
LUN can be used to present a smaller view of the total amount of disk
storage available to a server. For example if you partition a drive into small
pieces for an application or to accommodate disk limitations of your server’s
operating system, each segment would share a common SCSI target ID,
with each partition having a unique LUN.
LUN Manager streamlines the processes associated with adding,
configuring, modifying, deleting, and reassigning LUNs to specific paths
without having to reboot your array. LUN Manager also lets you assign
multiple paths to a single LUN to support alternative path failover, path load
balancing, and clustered systems.
Feature
•Password Protection
Your Hitachi Simple Modular Storage 100 offers several data-protection
features to protect your critical data assets. Password Protection lets you
restrict access to your Hitachi Simple Modular Storage 100 to one registered
user at a time.
1–4Introduction
Hitachi Simple Modular Storage 100 User’s Guide
Monitoring System Performance
Feature
•Hitachi Performance Monitor feature
With business infrastructures constantly growing more complex, companies
need the knowledge, skills, and tools to quickly identify potential
bottlenecks in each element of the infrastructure and take corrective action,
preferably before a problem becomes severe enough to be noticed.
Performance Monitor is an essential tool for planning and analysis of storage
resource requirements. It provides detailed, in-depth storage performance
monitoring and reporting of your Hitachi Simple Modular Storage 100,
including drives, logical volumes, processors, cache, ports, and other
resources. It can help you achieve and maintain service-level objectives for
performance and availability , identify stor age performance bottlenecks, and
maximize the utilization of your storage assets. Performance Monitor’s indepth troubleshooting and analysis reduce the time to resolve storage
performance problems.
Supported Host Operating Systems
Y our Hitachi Simple Modular Storage 100 works with a number of operating
systems, including:
•Microsoft Windows Server 2003, XP, and Vista
•Red Hat Linux
•Red Flag Linux
•SUSE Linux
•Solaris
•VMware
The list of supported host operating systems continues to grow. For the
latest information, please refer to the Hitachi Feature and Interoperability
Reports at https://extranet.hds.com/http://hifirerw.hds.com/HiFire/
GuestRegister.jsp.
Supported Topologies
Y our Hitachi Simple Modular Storage 100 is designed to provide disk storage
for use by your host servers. At its front end, your Hitachi Simple Modular
Storage 100 uses the iSCSI protocol over Ethernet to connect to iSCSI HBAs
or NICs installed in your server. This connection can be a direct, point-topoint connection or a switched configuration through an IP storage switch
(also known as a “fabric”).
At its back end, your Hitachi Simple Modular Storage 100 contains six,
eight, or 12 internal SATA or SAS drives. The drives are preconfigured for
RAID 6 and are not intended to be removed from the array . Two spare drive
slots are provided for adding capacity, for a total of 12 drives and 9 TB of
storage.
Introduction1–5
Hitachi Simple Modular Storage 100 User’s Guide
Direct Connect Topology
Figure 1-1 shows an example of a direct connection between your Hitachi
Simple Modular Storage 100 and host server. In a direct-connect
configuration, the host server can reside up to 100 meters (328 feet) from
your Hitachi Simple Modular Storage 100.
•
ServersH itachi Simple
Figure 1-1: Example of a Direct Connection
Switch (Fabric) Topology
Figure 1-2 shows an example of using your Hitachi Simple Modular Storage
100 in a switch (fabric) configuration. Y our Hitachi Simple Modular Storage
100 supports up to 256 connections in a switch configuration. The Storage
Area Network shown in the figure is an Ethernet network used to exchange
data between your servers and your Hitachi Simple Modular Storage 100.
•
ServersGigabit Ethernet
Switch
Modular Storage 100
Hitachi Simple
Modular Storage 100
Management
Console
Management
Console
Servers
Gigabit Ethernet
Switch
Figure 1-2: Example of a Switch Connection
1–6Introduction
Hitachi Simple Modular Storage 100 User’s Guide
Concepts and Terms
This section describes key concepts and terms you will find helpful when
using your Hitachi Simple Modular Storage 100. For additional assistance, a
Glossary at the back of this guide defines the technical terms in this guide.
RAID 6
Drives in your Hitachi Simple Modular Storage 100 are preconfigured for
RAID 6. RAID 6 is an extension of the RAID 5 arra y, with a second
independent distributed parity scheme. Data and parity are striped on a
block level across multiple array members, and a second set of parity is
calculated and written across all drives. In this way, RAID 6 delivers
enhanced data protection compared with single-parity RAID systems by
allowing for two simultaneous drive failures without downtime or data loss.
Y our Hitachi Simple Modular Storage 100 supports RAID 6 in 6-, 8-, or 12drive configurations:
•For arrays with six drives, four drives are used for data and two are
used for parity.
•For arrays with eight drives, six drives are used for data and two are
used for parity.
•For arrays with 12 drives, 9 drives are used for data, two are used for
parity, and one acts as a spare in case one of the other drives fails.
iSCSI
Y our Hitachi Simple Modular Storage 100 is an iSCSI storage device. iSCSI
(pronounced “eye skuzzy”) is an IP-based protocol that leverages the low
cost and familiarity of Ethernet and IP networking.
iSCSI links data storage devices over standard Ethernet-based TCP/IP
networks using small computer system interface (SCSI) commands.
Because iSCSI uses the standard Ethernet infrastructure to provide access
to storage “targets,” it is compatible with, and can connect directly to,
standard Gigabit Ethernet switches and IP routers. In this way, iSCSI
enables low-cost storage access through the mature and predominant
Ethernet infrastructure.
iSCSI Initiators and Targets
iSCSI defines a SCSI encapsulation protocol across a TCP/IP connection. As
with SCSI, there are two types of components in an iSCSI system: initiators
and targets.
An iSCSI initiator is a hardware device — such as an iSCSI host bus adapter
(HBA) or TCP/IP offload engine (TOE) — and/or software installed in a
server. The iSCSI initiator is the source of iSCSI commands that are sent
over the network to the target. As such, it is responsible for:
•Originating iSCSI requests for target discovery and target connection.
•Creating the iSCSI packets.
Introduction1–7
Hitachi Simple Modular Storage 100 User’s Guide
LUNs
•Handling transmission of the packets and corresponding responses
using TCP/IP.
An iSCSI target is a device that receives iSCSI requests originating from an
iSCSI initiator. Typically, the target is a drive contained in a storage device,
such as your Hitachi Simple Modular Storage 100.
The following steps describe the sequence followed by the iSCSI initiator
and target when establishing a “session.”
1. The iSCSI initiator starts a TCP session with a target and tries to log in
by sending a list of log-in parameters.
2. The initiator and target may insist on authenticating each other with one
of several authentication methods (described next), depending on the
system's configuration.
3. After passing the authentication stage, the initiator and target negotiate
operating parameters, after which SCSI commands and data can pass
between them.
Y our Hitachi Simple Modular Storage 100 includes several drives, with each
drive including many gigabytes of storage. To effectively enable access to
this storage, it is organized into smaller portions called logical units or
volumes that can be allocated to different resources that want to access the
storage.
CHAP
Each volume itself consists of a numeric address, thereby permitting the
storage on your Hitachi Simple Modular Storage 100 to appear as many
smaller storage units to the host computers accessing it, enabling more
efficient operation. To the server, a volume appears to be a single virtual
“disk”.
LUNs can be assigned to hosts, so that a particular volume can be accessed
only by designated hosts that have “permission” to access that portion of
the storage. This provides enhanced security as the software controlling
access to the storage system will only permit access by certain previously
defined hosts. While it is somewhat arbitrary how many hosts are permitted
to access a given volume, conventionally only one host usually has access
rights to a given volume at a given time. As a result, data on t he volume is
protected against access by hosts or servers other than those previously
designated, thereby enhancing the security of the data.
The Challenge Handshake Authenti catio n Protocol (CHAP) is a security
mechanism that one entity uses to verify the identity of another entity,
without revealing a secret password that is shared by the two entities. In
this way, CHAP prevents an unauthorized system from using an authorized
system's iSCSI name to access storage.
1–8Introduction
Hitachi Simple Modular Storage 100 User’s Guide
CHAP involves configuring a secret that both your Hitachi Simple Modular
Storage 100 and the host server must know . You enable and configure CHAP
using Storage Navigator Modular 2. CHAP is not enabled by default, but it
is strongly recommended. The Storage Navigator Modular 2 online help
describes how to enable and configure CHAP.
The following sequence describes how CHAP works when it is configured and
enabled on your Hitachi Simple Modular Storage 100.
1. During negotiations between the iSCSI initiator and target, the initiator
sends a “challenge” message to the target.
2. The target responds with a calculated value.
3. The initiator compares the response against its own calculation of the
value. If the values match, the initiator acknowledges the
authentication; otherwise, it terminates the connection.
At random intervals, the initiator sends a new challenge to the target and
repeats steps 1 through 3 to ensure that it is communicating with the
appropriate peer.
Introduction1–9
Hitachi Simple Modular Storage 100 User’s Guide
1–10Introduction
Hitachi Simple Modular Storage 100 User’s Guide
2
Dri
P
LED
Dri
Identifying Hardware
Components
In This Chapter
This chapter describes the hardware components on your Hitachi
Simple Modular Storage 100 array. This chapter covers the
following key topics:
Front Panel Components
Back Panel Components
Top Components
Front Panel Components
Figure 2-1 shows the hardware components on the front panel of
your Hitachi Simple Modular Storage 100.
•
ve Slot
(behind bezel)
•
ower
(green)
Ready LED
(green)
Warning LED
(orange)
Figure 2-1: Front Panel Components
ve Slot
(behind bezel)
Alarm LED
(red)
Identifying Hardware Components2–1
Hitachi Simple Modular Storage 100 User’s Guide
Drive Slots
The front panel of your Hitachi Simple Modular Storage 100 has two drive
slots. Each slot can accommodate a spare drive. The spare drive must be of
the same type (SATA or SAS) as the other drives in your Hitachi Simple
Modular Storage 100.
Front Panel LEDs
The front panel has several light-emitting diodes (LEDs) that show the
status of your Hitachi Simple Modular Storage 100.
Power LED
The front panel has a green Power LED that shows when your Hitachi
Simple Modular Storage 100 is turned on and receiving power.
LED StatusDescription
ONHitachi Simple Modular Storage 100 is turned on and receiving power .
OFFHitachi Simple Modular Storage 100 is not turned on.
Table 2-1: Front Panel Power LED
Ready LED
Alarm LED
The green Ready LED shows when your Hitachi Simple Modular Storage
100 is ready for operation.
Table 2-2: Ready LED
LED StatusDescription
ONNormal operation; the array is operational.
Slow BlinkDownloaded firmware execution procedure is finished (displayed
during maintenance mode).
Fast BlinkFirmware is downloading (do not turn off the array).
The red Alarm LED shows when your Hitachi Simple Modular Storage 100
is operating normally or has encountered a fatal error.
Table 2-3: Alarm LED
LED StatusDescription
OFFNormal operation
ONFatal error. Please visit the Hitachi Web Portal at http://
support.hds.com.
Slow BlinkA serious failure has occurred. Please visit the Hitachi Web Portal at
http://support.hds.com.
2–2Identifying Hardware Components
Hitachi Simple Modular Storage 100 User’s Guide
Warning LED
The orange Warning LED shows when your Hita chi Simple Modular Storage
100 is operating normally, has encountered a nonfatal error, and is
upgrading firmware.
LED StatusDescription
OFFNormal operation
ON or Slow
Blink
Fast BlinkFlash is being updated with new firmware (do not turn off the array).
Nonfatal error. Array can remain operating.
Back Panel Components
Figure 2-2 shows the key hardware components on the back panel of a 2-
controller Hitachi Simple Modular Storage 100. Components associated with
CTL0 are indicated with blue callouts in the following figure, while
components associated with CTL1 are indicated with red callouts. If your
Hitachi Simple Modular Storage 100 has a single controller, ignore the
components for CTRL 1.
Table 2-4: Warning LED
NOTE: If your Hitachi Simple Modular Storage 100 has a single controller,
ignore the components for CTL1.
•
Auto Migration Port
iSCSI Data Ports
CTL1
CTL0
Fan
MAIN Switch
Maintenance Port
Management Port
Power
Receptacle
Management Port
Maintenance Port
Power
Receptacle
Fan
iSCSI Data Ports
Auto Migration Port
Figure 2-2: Key Back Panel Components
Identifying Hardware Components2–3
Hitachi Simple Modular Storage 100 User’s Guide
iSCSI Gigabit Ethernet Data Ports (PORT A and PORT B)
Each Hitachi Simple Modular Storage 100 controller has two standard RJ-45
Ethernet iSCSI data ports labeled PORT A and PORT B. Each iSCSI data
port provides a 1-Gigabit Ethernet interface for direct or switched
connections to IP hosts that require IP access to storage. Each iSCSI data
port accepts a straight-through or cross-over Ethernet cable, and
automatically adjusts to the type of cable used.
iSCSI Data Port B
CTL1
CTL0
iSCSI Data Port AiSCSI Data Port B
iSCSI Data Port A
Figure 2-3: Location of iSCSI Data Ports on the Back Panel
Each iSCSI data port has an amber port activity LED on the left side of the
port and a green link LED on the right side.
Table 2-5: Port Activity LED
LED StatusDescription
OFFData is not being sent or received on the port.
ONData is being sent or received on the port.
Table 2-6: Link LED
LED StatusDescription
OFFLink status error.
ONLink status is normal.
2–4Identifying Hardware Components
Hitachi Simple Modular Storage 100 User’s Guide
10/100 Ethernet Management Ports (LAN)
Each Hitachi Simple Modular Storage 100 controller has a 10/100BaseT
Ethernet management port labeled LAN. These ports connect to the PC
acting as the management console.
Using these ports, you can configure and manage your Hitachi Simple
Modular Storage 100 using the Hitachi Storage Navigator Modular 2
software on the supplied CD. You can also use the storage features
described under Storage Features on page 1-3 to interact with your Hi tachi
Simple Modular Storage 100.
These ports accept either a cross-over cable for direct connections to the
management port or a straight-through cable if connecting to the
management port through a switch.
Each management port has an amber port activity LED on the left side of
the port and a green link LED on the right side (see Table 2-5 on page 2-4
and Table 2-6 on page 2-4).
NOTE: If you use the Storage Navigator Modular 2 software to configure
your Hitachi Simple Modular Storage 100 to send email alerts, be sure the
management port can communicate via Ethernet with your mail server. For
more information, refer to the Storage Navigator Modular 2 online help.
•
Management Port
CTL1
CTL0
Management Port
Figure 2-4: Location of Management Ports on the Back Panel
Each Hitachi Simple Modular Storage 100 controller has a 10/100 10/
100Base T Ethernet maintenance por t labeled MAINTENACE ONLY. These
ports are for performing troubleshooting procedures in the unlikely event
you encounter a problem with your Hitachi Simple Modular Storage 100. Y ou
should not have to use these ports unless instructed to do so by an Hitachi
Customer Service Representative.
Each maintenance port has an amber port activity LED on the left side of
the port and a green link LED on the right side (see Table 2-5 on page 2-4
and Table 2-6 on page 2-4).
•
Maintenance Port
CTL1
CTL0
Fans
Maintenance Port
Figure 2-5: Location of Maintenance Ports on the Back Panel
•
The back panel has two fans that provide ventilation for your Hitachi Simple
Modular Storage 100. The fans pull air from the front and exhaust to the
back. When you install your Hitachi Simple Modular Storage 100, be sure
these fans are not blocked and that there is a free flow of air passing from
the front of your Hitachi Simple Modular Storage 100. The fans provide
redundant cooling. If one fan fails, the other fan runs at a higher speed to
compensate for the loss.
•
FanFan
Figure 2-6: Location of Fans on the Back Panel
2–6Identifying Hardware Components
Hitachi Simple Modular Storage 100 User’s Guide
Power Supplies
Your Hitachi Simple Modular Storage 100 comes with two fully redundant
power supplies. If one power supply fails, the other one takes over to
compensate for the loss.
Each power supply has its own power receptacle that is accessed on the
back panel. Both receptacles must be connected to a working AC source
using the supplied power cable.
A green LED above each power receptacle blinks when the corresponding
power receptacle is connected to a working AC outlet, even if your Hitachi
Simple Modular Storage 100 is not powered on; otherwise, the LED is OFF.
Below each power receptacle is a holder you can use to secure the power
cable after connecting it to your Hitachi Simple Modular Storage 100.
•
When connecting
CAUTION!When connecting to an AC outlet, do not use an outlet
controlled by a wall switch. Otherwise, you will lose access to your
Hitachi Simple Modular Storage 100 if the wall switch is
inadvertently turned off.
•
Power LEDPower LED
Power Receptacle
Power Cable Holder
Power Receptacle
Power Cable Holder
Figure 2-7: Location of Power Receptacles, LEDs, and Cable Insets
Identifying Hardware Components2–7
Hitachi Simple Modular Storage 100 User’s Guide
ON/OFF Switch (MAIN SW)
The back panel has an ON/OFF switch labeled MAIN SW that applies power
to your Hitachi Simple Modular Storage 100. To apply power, move this
switch to the following ON position:
The Power LED on the front panel goes ON.
To turn off your Hitachi Simple Modular Storage 100, move the MAIN SW
switch to the following OFF position:
The front panel Power LED and the C-PWR LED on the back panel both go
OFF.
•
WARNING! Before you move your Hitachi Simple Modular Storage
100, set the MAIN SW switch to the OFF position and disconnect the
power cables from the power receptacles and from the AC source.
•
C-PWR LED
MAIN SW Switch
Figure 2-8: Location of MAIN SW Switch on the Back Panel
Mode Switch
The back panel has a mode switch labeled MODE that places a dualcontroller Hitachi Simple Modular Storage 100 into migration mode.
2–8Identifying Hardware Components
Hitachi Simple Modular Storage 100 User’s Guide
For normal operation, the mode switch should be in the N position. The E
position is used when you need to migrate data from one dual-controller
Hitachi Simple Modular Storage 100 to another. The back panel C-PWR LED
then goes OFF and the EXT LED goes ON to show that the array is in
migration mode. For more information, see Migrating Data on page 4-7.
•
NOTE: When you move the MODE switch to the E position, a question
mark (?) appears for the status shown for the array in Storage Navigator
Modular 2 to show that the array is in migration mode.
•
EXT LEDMODE Switch
Figure 2-9: Location of MODE Switch and EXT LED on the Back Panel
Top Components
The top of your Hitachi Simple Modular Storage 100 may have cautions,
product information labels, and/or agency certifications.
Identifying Hardware Components2–9
Hitachi Simple Modular Storage 100 User’s Guide
2–10Identifying Hardware Components
Hitachi Simple Modular Storage 100 User’s Guide
3
Installing Your Array
This chapter describes how to install your Hitachi Simple Modular
Storage 100 array. This chapter covers the following key topics:
Installation at a Glance
Preparing Your Site
Safety Considerations
Unpacking
Required Items Supplied by the User
Installing the Hitachi Simple Modular Storage 100
Verifying Startup Operations
Configuring and Managing Your Storage
Installing iSCSI Initiator Software
Hitachi Simple Modular Storage 100 Host Installation Guide
Installing Your Array3–1
Hitachi Simple Modular Storage 100 User’s Guide
Installation at a Glance
Table 3-1 describes the steps to follow when installing your Hitachi Simple
Modular Storage 100.
1. Prepare Your
Site
5. Install the
9. See Host
Installation
Array
Guide
StepDescriptionSee Page
1.
2.
3.
4.
5.
6.
7.
8.
9.
2. Review All
Safety
Considerations
6. Verify
Startup
Operations
3. Unpack the
Array
7. Configure &
Manage
Storage
Required Items
8. Install iSCSI
Figure 3-1: Installation Roadmap
Table 3-1: Installation Roadmap
Prepare the site where you intend to install your Hitachi Simple
Modular Storage 100.
Review all safety considerations before you start the installation
process.
Unpack and make sure all items are accounted for and not
damaged.
Obtain the required user-supplied items to perform the
installation.
Install your Hitachi Simple Modular Storage 100. The array can
be installed on a desk or shelf or in a rack.
Verify startup operations.
Configure and manage your storage.
Install iSCSI initiator software.
Consult the Hitachi Simple Modular Storage 100 Host Installation
Guide for your host operating system.
4. Obtain
Initiator
3-3
3-5
3-7
3-8
3-9
3-17
3-18
3-22
3-22
3–2Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
Preparing Your Site
Planning the proper location and layout of your Hitachi Simple Modular
Storage 100 is essential for its successful operation. Equipment placed too
close together or in an inadequately ventilated area can cause overtemperature conditions. In addition, poor equipment placement can make
the back panel inaccessible.
To ensure normal operation and to avoid unnecessary maintenance, plan
your site configuration and prepare your site before installation. The
following sections provide guidelines to be observed when preparing your
site prior to installing your Hitachi Simple Modular Storage 100.
Topology Considerations
Plan the topology in which your Hitachi Simple Modular Storage 100 will be
used. Determine whether you want to set up a dedicated point-to-point
configuration for your Hitachi Simple Modular Storage 100 and its iSCSI
initiators (a recommended, simple configuration) or include your Hitachi
Simple Modular Storage 100 in a shared and potentially complex switch
configuration that requires more network expertise and possibly the use of
Challenge Handshake Authentication Protocol (CHAP) security.
For more information, see Supported Topologies on page 1-5.
Site Considerations
The site where you install your Hitachi Simple Modular Storage 100 can
affect its performance. Therefore, choose a site that:
•Is fairly cool and dry for the acceptable temperature and humidity
ranges.
•Is free of strong electromagnetic field generators (such as motors),
vibration, dust, and direct exposure to sunlight.
•Provides a sturdy, level surface that can support your Hitachi Simple
Modular Storage 100. A fully populated unit weighs approximately 72.6
lbs. (33 kg.).
•Has a power outlet within six feet (1.82 meters) of your Hitachi Simple
Modular Storage 100.
•Allows for at least six inches (152.3 mm) of space at the front and back
of your Hitachi Simple Modular Storage 100 for ventilation.
•Will not place your Hitachi Simple Modular Storage 100 next to, on top
off , or below any device that generates heat or will block the fee flow of
air through the array’s ventilation slots.
Installing Your Array3–3
Hitachi Simple Modular Storage 100 User’s Guide
Rack-Mount Considerations
The following additional considerations must be observed for rack
installations (see Figure 2 4):
•Y our Hitachi Simple Modular Storage 100 can be mounted in a standard
19-inch rack. The rack-mounting hardware must be carefully selected
to properly support the equipment. Follow the instructions in the
documentation for the rack.
•The operating ambient temperature of rack-mounted equipment must
not exceed the maximum r a ted ambient temperature indicated in this
guide (refer user to Appendix A for more information).
•The air flow clearances specified in this guide must be maintained
within the rack.
•The AC supply circuit for rack-mounted equipment must be capable of
supplying the total current specified on all the labels of the rackmounted equipment.
•All AC power supply connections must be properly earthed. To ensure
the integrity of the earth connection, special attention must be given to
connections that are not directly connected to the branch circuit (for
example, power strips).
Server Considerations
•Your Hitachi Simple Modular Storage 100 supports a variety of client
operating systems (see Supported Host Operating Systems on page 1-
5).
•Be sure your server has an installed iSCSI HBA or NIC with the latest
HDS-supported Basic Input Output System (BIOS). For the latest HDSsupported iSCSI HBAs and NICs, please refer to Hitachi Feature and
Interoperability Reports at https://extranet.hds.com/http://
hifirerw.hds.com/HiFire/GuestRegister.jsp.
•Follow the directions for your iSCSI HBA or NIC to install the card and
its appropriate driver(s). Install any required updates, such as service
packs, hot fixes, or patches, and reboot the server when the installation
is complete.
•Be sure your server is using an HDS-supported iSCSI initiator and
driver. For a list of HDS-supported iSCSI initiators and HBAs, please
refer to Hitachi Feature and Interoperability Reports at https://
Observe the following guidelines to ensure safety. Failure to follow these
guidelines could result in bodily injury or damage to your Hitachi Simple
Modular Storage 100 chassis or components
•Do not wear loose clothing that could get caught in the chassis or
mounting hardware.
•Wear safety glasses when working under conditions that are hazardous
to your eyes.
•Do not perform any action that creates a potential hazard to people or
makes the equipment or rack unsafe.
•Do not work on the equipment or disconnect cables during a
thunderstorm, when wearing a wool sweater or other heavy wool
clothing, or when power is applied.
•Disconnect all power before installation.
•Avoid hazards such as moist floor and ungrounded power-extension
cables.
•To avoid damage to your Hitachi Simple Modular Storage 100 due to
electrostatic discharge (ESD), wear an anti-static wrist strap. Connect
the clip to an unpainted part of the array chassis frame to safely
channel any static electricity generated by your body to ground. If no
wrist strap is available, ground yourself by touching an unpainted part
of the array chassis frame.
•A fully populated Hitachi Simple Modular Storage 100 weighs
approximately 72.6 pounds (33 kg) and requires three or more persons
to lift the array. Always turn off your Hitachi Simple Modular Storage
100 and unplug all data and power cables before lifting.
•If rack mounting the array, mount the array at the bottom of the rack.
If the array is mounted at the top of the rack, the rack may become
unstable and fall.
Installing Your Array3–5
Hitachi Simple Modular Storage 100 User’s Guide
WARNING! During installation, if your Hitachi Simple Modular Storage 100
falls at a high position, a personal injury will be caused. Three or more
persons are required to installing the array in a rack above chest level.
Perform the positioning, fastening, or other handlings very carefully.
CAUTION!Be sure to perform the rack installation with three or
more persons. Work carefully because a single Hitachi Simple
Modular Storage 100 can weigh 72.6 pounds (33 kg). Be sure to
install the array from the bottom of the rack to prevent the rack
from falling. Lift the array up to the height suitable for mounting.
Adjust the position of the array, so it is seated in the center of the
rack frame. Shift the array onto the rails in the rack frame. When
shifting the array, push it in to the end gently.
3–6Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
Unpacking
After receiving your Hitachi Simple Modular Storage 100, perform the
following steps to ensure that your contents arrived safely .
1. Inspect the outer shipping container for damage during shipping. Report
2. Remove the contents from the shipping container and check for the
3. Inspect your Hitachi Simple Modular Storage 100 thoroughly. If you see
•
any sign of damage to the appropriate shipping carrier.
following items:
• One Hitachi Simple Modular Storage 100
• Two power cables
• A front bezel
• Product and documentation CDs
• One Quick Installation Guide
any signs of damage, contact the shipping carrier.
Product and
Documentation CDs (2)
Power Cords (2)
Accessory Box
Quick Installation
Guide
Front Bezel
(in Polyethylene Bag)
Buffer Pads
Hitachi Simple Modular Storage
100 (in Polyethylene Bag with
Desiccating Agent)
In addition to the contents supplied in your Hitachi Simple Modular Stor age
100, the following user-supplied items are required to perform the
installation.
For your Hitachi Simple Modular Storage 100
•An IP address, subnet mask, gateway (if applicable), and Ethernet
cable for each iSCSI data port that will connect to your storage network
•An IP address and Ethernet cable for each management port
•Two AC outlets (100 V to 120/200 V to 240 V)
For the computer that will act as the iSCSI initiator
•A NIC
•An iSCSI initiator driver for your operating system
For the computer that will act as the management console
•An installed NIC with connection to the storage network
•Video resolution of 800 x 600 dots per inch (1024 x 768 or higher
recommended)
•One of the following operating systems:
• Microsoft Windows XP (Service Pack 2)
• Microsoft Windows 2003 Server (Service Pack 1)
• Microsoft Windows 2000 (Service Pack 3/4)
• Sun™ Solaris™ v8
• Sun Solaris v9
•Internet access using one of the following browsers
• Internet Explorer v6.0
• Mozilla v1.7
•
CAUTION!Pop-up blockers must be disabled in the browse r.
Rack-mount users require the following additional items
•A standard 19-inch rack.
•Mounting hardware for the specific rack being used.
•Documentation for the rack and mounting hardware.
3–8Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
Optional Items
An Ethernet switch and Ethernet cable are required to use your Hitachi
Simple Modular Storage 100 in a switch (fabric) topology.
•
Installing the Hitachi Simple Modular Storage 100
Installing your Hitachi Simple Modular Storage 100 involves the following
steps:
1. Installing your Hitachi Simple Modular Storage 100 on a table or shelf or
in a rack. See the sections below.
2. Attaching the front panel bezel. See page 3-12.
3. Connecting to the 10/100 Ethernet management ports. See page 3-14.
4. Connecting to the iSCSI Gigabit Ethernet Data Ports. See page 3-15.
5. Connecting power. See page 3-16.
Installing on a Table or Shelf
If installing your Hitachi Simple Modular Storage 100 on a table or shelf:
•Place your Hitachi Simple Modular Storage 100 near an AC power
source.
•Allow enough ventilation space between your Hitachi Simple Modular
Storage 100 and other objects in the vicinity.
•Be sure the air vents on the front and back of the your Hitachi Simple
Modular Storage 100 enclosure are not blocked.
WARNING! Three or more persons are required to lift your Hitachi
Simple Modular Storage 100. Grasp the enclosure from the bottom
and lift with both hands. To prevent injury, keep your back straight
and lift with your legs, not your back.
Rack-Mounting the Hitachi Simple Modular Storage 100
Y our Hitachi Simple Modular Storage 100 can be mounted in a standard 19inch rack. The rack-mount and/or rail kit hardware must be carefully
selected to support the equipment properly. Follow the instructions in the
documentation for the rack and/or rail kit. F or more information, please
contact your place of purchase.
The following procedure provides general guidelines to follow when
installing your Hitachi Simple Modular Storage 100 in a rack.
WARNING! Three or more persons are required to lift your Hitachi
Simple Modular Storage 100. Grasp the enclosure from the bottom
and lift with both hands. To prevent injury, keep your back straight
and lift with your legs, not your back.
•
DANGER! Before mount your Hitachi Simple Modular Storage 100 in a
rack, be sure the rack is secure and is in no danger of falling over.
Installing Your Array3–9
Hitachi Simple Modular Storage 100 User’s Guide
•
NOTE: Be sure the rack provides sufficient airflow to the front and back of
your Hitachi Simple Modular Storage 100 to maintain correct cooling.
1. Verify that your Hitachi Simple Modular Storage 100 is turned off.
2. Verify that the MAIN SW switch is in the OFF position.
3. With help from another person, position and hold your Hitachi Simple
Modular Storage 100 in the rack. Then secure the array to the rack frame
using M5×10 binding screws (one screw at the right and left sides of the
array, as sho wn in Figure 3-3). For more information, refer to the
manual for your mounting hardware and rack.
•
WARNING! To prevent bodily injury when mounting or servicing
your Hitachi Simple Modular Storage 100 in a rack, you must take
special precautions to ensure that the array remains stable. The
following guidelines are provided to ensure your safety:
•Perform the rack installation with three or more persons.
•Work carefully because a single Hitachi Simple Modular Stor age 100 can
weigh 72.6 pounds (33 kg).
•Your Hitachi Simple Modular Storage 100 should be mounted at the
bottom of the rack if it is the only unit in the rack.
•Lift the array up to the height suitable for mounting. Adjust the position
of the array, so it is seated in the center of the rack frame. Shift the
array onto the rails in the rack frame. When shifting the array , push it in
to the end gently.
•When mounting your Hitachi Simple Modular Stor age 100 in a partially
filled rack, load the rack from the bottom to the top, with the heaviest
component at the bottom of the rack.
•If the rack is provided with stabilizing devices, install the stabilizers
before mounting or servicing your Hitachi Simple Modular Storage 100
in the rack.
•
WARNING! During installation, if your Hitachi Simple Modular
Storage 100 falls at a high position, a personal injury will be caused.
Three or more persons are required to installing the array in a rack
above chest level. Perform the positioning, fastening, or other
handlings very carefully.
•
3–10Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
•
Screws Securing the ArrayBinding Screw
Figure 3-3: Example of Securing the Array to a Rack
Installing Your Array3–11
Hitachi Simple Modular Storage 100 User’s Guide
Attaching the Front Panel Bezel
For table and shelf installations, the bezel connects directly to the four ball
catches (two on each side) of the Hitachi Simple Modular Storage 100 front
panel:
1. Unwrap the front bezel.
2. Holding the side of front bezel with both hands, align it with the four ball
catches on the front panel.
3. Gently push the bezel against the catches and front panel until the bezel
snaps into place.
Figure 3-4 shows how to attach the bezel for table and shelf installations.
•
Figure 3-4: Attaching the Front Bezel (Table/Shelf Installations)
For rack -mount installations, attach the bezel to the front left and right sides
of the rack chassis (see Figure 3-5 on page 3-13).
3–12Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
•
Figure 3-5: Attaching the Front Bezel (Rack-Mount Installation)
CAUTION!It is important to keep the front panel bezel and rear
panel clean (see Caring for Your Hitachi Simple Storage Modular on page
4-7). Otherwise, the array’s internal temperature can increase,
causing the array to fail.
Removing the Front Panel Bezel
To remove the front bezel, grasp the front bezel and gently pull it toward
you until it disengages from the four ball catches (two on each side).
Installing Your Array3–13
Hitachi Simple Modular Storage 100 User’s Guide
Connecting to the 10/100 Ethernet Management Port
For local administrative access to your Hitachi Simple Modular Storage 100,
connect the 10/100 Ethernet management port to a PC acting as the
management console. Yo u can then use the Storage Navigator Modular 2
software to configure your Hitachi Simple Modular Storage 100.
Initially , you configure your Hitachi Simple Modular Storage 100 by directly
connecting a management console PC equipped with a NIC to each
management port using the default IP addresses in Table 3-2. These default
IP addresses can be changed using the Storage Navigator Modular 2
software. Thereafter, you can connect the management port(s) to your
network and access your Hitachi Simple Modular Storage 100 via the Web
using Storage Navigator Modular 2.
Table 3-2: Default Management Port IP Addresses
ControllerIP Address
Controller 0192.168.0.16
Controller 1192.168.0.17
1. Connect either end of an Ethernet cable to a NIC installed in a
management console.
2. Connect the other end of the cable to the management port(s) labeled
LAN on the back of your Hitachi Simple Modular Storage 100 (see
Figure 3-6 on page 3-15).
NOTE: If your Hitachi Simple Modular Storage 100 has one controller,
ignore the management port on CTL1 in Figure 3-6 on page 3-15.
3. Configure the NIC in the management console to use the subnet
192.168.0.x.
4. Launch your browser and access the management port at the
appropriate default IP address:
• For CTL0, use the IP address 192.168.0.16.
• For CTL1, use the IP address 192.168.0.17.
NOTE: If you are not able to connect, you may need to use a cross-over
cable between the management console PC and the management ports.
5. Perform the configuration activities for that controller.
6. If your Hitachi Simple Modular Storage 100 has a second controller,
perform the configuration activities for the other controller using the
appropriate IP address in Table 3-2.
•
3–14Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
•
Management Port on CTL1
Management Port on CTL0
Figure 3-6: Management Ports
Connecting to the iSCSI Gigabit Ethernet Data Ports
The following procedure describes how to connect the iSCSI Gigabit
Ethernet data ports to your storage network or server. The default IP
addresses for the iSCSI data ports are shown in Table 3-3. These settings
can be changed using the Storage Navigator Modular 2 software.
NOTE: If your Hitachi Simple Modular Storage 100 has one controller,
ignore the IP addresses for on CTL1 in Table 3-3.
Table 3-3: Default iSCSI Data Port IP Addresses
ControlleriSCSI Data PortIP Address
Controller 0Port A192.168.0.200
Port B192.168.0.201
Controller 1Port A192.168.0.208
Port B192.168.0.209
1. On the back panel, insert one end of an Ethernet cable into an iSCSI data
port (either PORT A or PORT B) on the back of your Hitachi Simple
Modular Storage 100 (see Figure 3-7 on page 3-16 and Figure 3-8 on
page 3-16). Connect the other end of the cable to your host system or
switch.
2. To connect additional iSCSI data ports to your storage network, repeat
step 1 using another Ethernet cable and another available iSCSI data
port.
•
NOTE: If your Hitachi Simple Modular Storage 100 has one controller,
ignore the iSCSI data ports on CTL1 in Figure 3-7 on page 3-16.
•
NOTE: The IP address for your server(s) console must be on the same IP
subnetwork (192.168.0.x) as the iSCSI data ports.
Installing Your Array3–15
Hitachi Simple Modular Storage 100 User’s Guide
•
iSCSI Data Ports for CTL1
iSCSI Data Ports for CTL0
Figure 3-7: iSCSI Gigabit Ethernet Data Ports
•
Connecting Power
Your Hitachi Simple Modular Storage 100 comes with two power cables.
Both receptacles must be connected to a working AC source using the
supplied power cables. This provides redundancy in the unlikely event that
one power supply fails.
1. Make sure the MAIN SW switch on the back panel is in the OFF position
(see Figure 3-9 on page 3-17).
2. Attach one power cable to the 3-pronged power connectors on the back
panel and secure with the power clamp (see Figure 3-9 on page 3-17).
Attach the other end to a working AC outlet. Use the holder below the
receptacle to secure the power cable. The green LED above the power
receptacle blinks.
•
NOTE: The AC outlet should not be controlled by a wall switch. Otherwise,
the wall switch can accidentally turn off power to your Hitachi Simple
Modular Storage 100.
3. We recommend that you repeat step 2 to connect and secure the second
power cable.
4. Set the MAIN SW switch to the ON position.
Figure 3-8: Connecting an Ethernet Cable
3–16Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
•
Power LED
Figure 3-9: Attaching the Power Cables
Verifying Startup Operations
To verify that your Hitachi Simple Modular Storage 100 is installed and
starts up properly:
1. On the back panel, verify that the green LEDs above each power
receptacle are blinking.
Power LED
Power Cable HolderPower Cable HolderMAIN SW Switch
2. Set the MAIN SW switch on the back panel to the ON position to apply
power.
3. Listen for the fans to start operating and check for airflow.
4. On the front panel, verify that the green Power LED goes on (see
Figure 2-1 on page 2-1).
5. In a few minutes, verify that the green Ready LED on the front panel
goes ON (see Figure 2-1 on page 2-1).
•
Installing Your Array3–17
Hitachi Simple Modular Storage 100 User’s Guide
Configuring and Managing Your Storage
After you verif y startup operations, your H i tachi Simple Modular Storage
100 is ready for software configuration using the Storage Navigator Modular
2 software on the supplied CD.
With primary goals of simplicity and ease-of-use, the configuration of your
Hitachi Simple Modular Storage 100 has been designed to make things
obvious for new users from the get-go. To that end, the Storage Navigator
Modular 2 software includes the following wizards and point-and-click
screens for configuring, provisioning, and managing your storage quickly
and easily.
Installing the Storage Navigator Modular 2 Software
The Storage Navigator Modular 2 software is installed on the management
console attached to the LAN management port. The console must meet the
following minimum requirements:
•Intel processor: 1 GHz (2 GHz or faster recommended)
•Memory: At least 1 GB
•Free disk space: 1.5 GB
•Video resolution: 1024 x 768
•Microsoft® Windows® XP (Service Pack 2), 2003 Server (Service Pack
1), Windows 2000 (Service Pack 3/4); or Sun Solaris™ v8 or v9
•Browser: Internet Explorer v 6.0 for Microsoft Windows operating
systems or Mozilla v1.7 for Solaris operating systems
•
CAUTION!Pop-up blockers must be disabled in the browse r.
To install Storage Navigator 2:
1. In the management console’s CD-ROM drive, insert the CD containing
the Storage Navigator Modular 2 software (see Figure 3-10).
•
Figure 3-10: Inserting the Storage Navigator Modular 2 CD
3–18Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
2. When the installation starts, follow the instructions in the friendly
screens that appear. As part of these instructions, you will be asked to
either accept the default destination directory where Storage Navigator
Modular 2 is to be installed or specify a different location.
NOTE: If autostart is turned off on the management console, double-click
the file SNM2.exe in the SNM2 folder to start the installation.
Logging in to Storage Navigator Modular 2
1. After you install Storage Navigator Modular 2, log in:
http://<IP address of management console PC>:23015/
StorageNavigatorModular/
2. When the login window appears (see Figure 3-11), enter system as the
default User ID and manager as the default password ID box.
NOTE: For security, each password character you type appears as a dot
(•). We recommend you change the default password to protect your
Hitachi Simple Modular Storage 100 against unauthorized access. For more
information, refer to the Storage Navigator Modular 2 online help.
3. Click the Login button.
Adding Arrays (Add Array Wizard)
When Storage Navigator Modular 2 is launched, it displays all existing
arrays contained in its database. The first time it starts, the database does
not contain any arrays and Storage Navigator Modular 2 launches the Add
Array wizard automatically.
Installing Your Array3–19
Hitachi Simple Modular Storage 100 User’s Guide
The Add Array wizard takes you step by step through the process of
discovering arrays on your stor age network and adding them to the Storage
Navigator Modular 2 database.
For more information, please refer to the Hitachi Simple Modular Storage 100 Quick Configuration Guide (MK-97DF8090) and the Storage Navigator
Modular 2 online help.
Configuring Array Drives (Initial Setup Wizard)
After you finish using the Add Array wizard, y ou use the Initial Setup wizard
to configure the array’s spare drives. This wizard lets you:
•Enable the array to send email notifications of serious array events
•Set the IP address, subnet mask, and default gateway for each
management port
•Select the type of negotiation to be used
•Set the IP addresses for each data port
After you run the Initial Setup wizard, you edit the management port IP
addresses for the controllers in your array to match the addresses you
specified in this wizard. For more information, please refer to the Hitachi Simple Modular Storage 100 Quick Configuration Guide (MK-97DF8090) and
the Storage Navigator Modular 2 online help.
Creating Logical Units
After you add arrays and configure the array drives, you define the logical
units to be allocated to the host. In this step, you:
•Add the LU to a RAID group
•Enter a LUN number and specifying the amount of free space to be
allocated to the LUN
•Specify a stripe size
•Indicate whether formatting is necessary
For more information, please refer to the Hitachi Simple Modular Storage 100 Quick Configuration Guide (MK-97DF8090) and the Storage Navigator
Modular 2 online help.
3–20Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
Specifying Mode Parameters
After you run the Storage Navigator Modular 2 wizards, use Storage
Navigator Modular 2 to set mode parameters. The selections you make will
be based on your host’s operating system and clustering configuration.
To access this page, use the following procedure.
1. If the Arrays pane appears next to the Explorer pane, skip to the next
step. Otherwise:
a. In the Explorer pane, click Resources > Arrays.
b. In the Arrays area, check an array to be initialized.
c. Click Show & Configure Array.
2. In the Arrays pane, select Groups > iSCSI Targets.
3. Under the iSCSI Target column, check an iSCSI target. Then click Edit Target.
4. When the Edit iSCSI Target window appears, click on the Options tab
and make the following selections (see Table 3-4):
a. Platform — select your host’s operating system. If your host’s
operating system is not shown, select not specified.
b. Middleware — select Not specified for all operating systems.
c. Common Setting — select Standard Mode for all operating
systems.
d. Additional Settings — select None for all operating systems.
Table 3-4: Mode Parameters
...and These Mode Settings
For This Operating
System
AsianuxLinuxNot specified (none)Standard ModeNone
Red Hat LinuxLinuxNot specified (none)Standard ModeNone
Microsoft Windows
2003
Microsoft Windows XP WindowsNot specified (none)Standard ModeNone
Microsoft Windows
Vista
SolarisSolarisNot specified (none)Standard ModeNone
SuSE Linux Enterprise
Server (SLES)
VMwareNot specifiedNot specified (none)Standard ModeNone
Select This
Platform...
WindowsNot specified (none)Standard ModeNone
WindowsNot specified (none)Standard ModeNone
LinuxNot specified (none)Standard ModeNone
...This Middleware
Setting...
Common
Setting
Additional
Settings
Installing Your Array3–21
Hitachi Simple Modular Storage 100 User’s Guide
Installing iSCSI Initiator Software
Depending on your operating system, you may need to download an
initiator software. For example, the iSCSI initiator for Microsoft Windows XP
or Windows Server 2003 can be downloaded free of charge from the
following site: http://www.microsoft.com/downloads. iSCSI initiator
software for Microsoft Windows Vista or Windows Server 2008, Solaris, and
VMware, on the other hand, are included with these operating systems.
Using the instructions for your iSCSI initiator, install the software on your
host and write the name of the initiator (you will need this when you enter
the iSCSI host name). Then tell your host where to find volumes on your
array. Depending on your oper ating system, you may also need to add the
target to the iSCSI service's binding list, initialize new drives, create
partitions, and format new volumes.
Before you start using your Simple Modular Storage 100, please refer to the
Hitachi Simple Modular Storage 100 Host Installation Guide that is
appropriate for your host operating system. These guides, which are
available on the documentation CD that came with your array, contain
valuable information specific to your operating system that will enable you
to get the most out of your Hitachi Simple Modular Storage 100.
3–22Installing Your Array
Hitachi Simple Modular Storage 100 User’s Guide
4
Maintaining Your Array
This chapter describes how to maintain your Hitachi Simple
Storage Modular 100 array. This chapter covers the following key
topics:
Installing Spares
Caring for Your Hitachi Simple Storage Modular
Migrating Data
Moving Your Hitachi Simple Storage Modular
Storing Your Hitachi Simple Storage Modular 100
Maintaining Your Array4–1
Hitachi Simple Modular Storage 100 User’s Guide
Installing Spares
Your Hitachi Simple Modular Storage 100 contains two compartments that
can accommodate spare drives. The array's hot-swappable feature enables
you to add the drives without shutting down or turning off your Hitachi
Simple Modular Storage 100.
To install a spare drive, you need:
•A new drive that meets the requirements in step 2 below.
•A server connected to the management port of your Hitachi Simple
Modular Storage 100.
Before You Begin
Before you begin, observe the following guidelines:
•The new drive(s) must be the same type (SAT A or SAS) as the others in
your Hitachi Simple Modular Storage 100.
•The new drive(s) must have the same capacity as the other drives in
your Hitachi Simple Modular Storage 100.
•Wear a wrist strap attached to chassis ground when performing this
procedure.
Checking for Defective Drives
Before installing a spare drive, use Storage Navigator 2 to see whether any
of the other drives are defective.
1. Start a Web browser and launch Storage Navigator 2.
2. Log in to Storage Navigator 2:
http://<IP address of management console PC>:23015/
StorageNavigatorModular/
3. In the Explorer pane and select Resources > Arrays.
4. If a Warning does not appear in the Status column, skip to Installing
the Spare Drives on page 4-5. Otherwise:
• Verify that the serial number shown in the Serial No. column
matches the one on your array (see Figure 4-2 on page 4-3).
• In the Array Name column, click the name of the array that has
the Warning status.
4–2Maintaining Your Array
Hitachi Simple Modular Storage 100 User’s Guide
•
Example of Array with W arning StatusSerial Number Column
•
Hardware Serial Number
Figure 4-1: Checking for Failed Drives
Figure 4-2: Locating the Serial Number
5. If one failed part is shown in the Alerts & Events window, click Show
Details (see Figure 4-3 on page 4-4), read the details about the failed
part in the Alarm Information window (see Figure 4-4 on page 4-4), and
click the link to the support site.
If two or more parts are shown, see Chapter 5, Troubleshooting.
•
NOTE: If the console does not have an Internet connection, note the
information shown and access the link from a computer that has a
connection to the Internet.
Maintaining Your Array4–3
Hitachi Simple Modular Storage 100 User’s Guide
•
Check Here
for Failed
Array
Show Details Button
Figure 4-3: Example of Failed Part in the Alerts & Events Window
•
Figure 4-4: Example of Alarm Information Window
•
4–4Maintaining Your Array
Hitachi Simple Modular Storage 100 User’s Guide
Installing the Spare Drives
To install the spare drives:
1. Wear an anti-static wristband connected to chassis ground.
2. Remove the new drive from its anti-static bag.
3. If you are replacing the drive due to a failure code you receiv ed, v erify
that the failure code in the Failed Pa rt List window matches the model of
the disk drive shown on the disk drive label (see Figure 4-5):
• WSx100 = Model AJH146xxx (142.63 Gbyte drive)
• WSx10a = Model AJH300xxx (287.62 Gbyte drive)
•
Disk Drive Label
Figure 4-5: Label on Disk Drive
4. With your Hitachi Simple Modular Storage 100 running, remove the front
panel bezel to gain access to the front of your Hitachi Simple Modular
Storage 100 (see Removing the Front Panel Bezel on page 3-13).
5. Locate the drive slot into which you will install the drive. Facing the front
of your Hitachi Simple Modular Storage 100, one slot appears on the left
side of the array and the other slot appears on the right.
6. Loosen the two screws on the selected drive slot.
7. Remove the repair slot cover and remove the “dummy” drive from the
slot.
8. Slide the new drive into the spare drive slot until the locking handle
engages (see Figure 4-6 on page 4-6). When the drive is firmly installed,
it begins to spin up automatically.
Maintaining Your Array4–5
Hitachi Simple Modular Storage 100 User’s Guide
•
Drive Slots
Dummy Drive
ScrewsRepair Slot CoverSpare Drive
Figure 4-6: Installing the Spare Drives
9. Be sure the drive is installed securely in the slot.
10.Attach the repair slot cov er, then secure it by tightening the two screws
you loosened in step 4.
11.Verify that the Warning LED goes OFF.
12.Replace the front panel bezel (see Attaching the Front Panel Bezel on
page 3-12).
13.Click the Refresh Information button to clear the Failed status and
verify that No Object appears in the Failed Part List (see s).
•
Refresh Information Button
Click Here for
No Object
Figure 4-7: Confirming No Object Status
14.In the Arrays window, verify that the array status is Normal.
15.R emo ve the anti-static wristband.
4–6Maintaining Your Array
Hitachi Simple Modular Storage 100 User’s Guide
Caring for Your Hitachi Simple Storage Modular
To keep your Hitachi Simple Modular Storage 100 operating at peek
performance, we recommend that you perform the fol l ow ing simple
maintenance tasks on a regular basis.
•
CAUTION!Do not pour or spray liquids directly onto your Hitachi
Simple Modular Storage 100.
•Clean the outside of your Hitachi Simple Modular Storage 100 with a
dry, lint-free cloth. Keep the cloth away from the array fans.
CAUTION!It is important to keep the front panel bezel and rear
panel clean. Otherwise, the array’s internal temperature can
increase, causing the array to fail.
•Remove the front bezel (see Removing the Front Panel Bezel on page
3-13). Then clean it with a dry, lint-free cloth and reattach the bezel
(see Attaching the Front Panel Bezel on page 3-12).
•Keep the air vents clean and free from dust.
Migrating Data
Y our Hitachi Simple Modular Storage 100 supports RAID 6. RAID 6 delivers
enhanced data protection compared by allowing for two simultaneous drive
failures without downtime or data loss.
In the unlikely event that a sufficient number of drive failures render your
Hitachi Simple Modular Storage 100 unusable, you can migrate your data to
a replacement array.
Performing array migration is straightforward using the Hitachi Simple
Modular Storage 100 Auto Migration Kit. The Kit comes with all the cables
and instructions you need to migrate data. For more information, please
visit the Hitachi Web Portal at http://support.hds.com. Instructions for
migrating data can also be found in the Auto Migration topic in the Storage
Navigator 2 online help.
•
TIP:Before you migrate data, you may want to print the relevant topics
from the Storage Navigator online help for reference.
Maintaining Your Array4–7
Hitachi Simple Modular Storage 100 User’s Guide
Moving Your Hitachi Simple Storage Modular
This section contains critical information for avoiding damage when moving
your Hitachi Simple Modular Storage 100. Before moving your Hitachi
Simple Modular Storage 100 across the room or to another nearby location,
be sure to remove all cables from the back panel.
Before You Move Your Hitachi Simple Modular Storage 100
Before moving your Hitachi Simple Modular Storage 100 longer distances,
including moves that require an elevator or a ride in a vehicle, use the
following checklist as a general guide.
Do not clean your Hitachi Simple Modular Storage when moving the
array.
Make sure the new location for your Hitachi Simple Modular Storage
100 meets the requirements described under Preparing Your Site on
page 3-3.
Do not disconnect your Hitachi Simple Modular Storage 100’s power
cable while the power is on or while the array’s internal fans are
operating.
After turning off your Hitachi Simple Modular Storage 100, allow the
array to cool.
Disconnect all data and power cables after your Hitachi Simple Modular
Storage 100 has cooled .
Gather the documentation (CD-ROMs, user guide, quick-start guide).
Have at least three persons move your Hitachi Simple Modular Storage
100 to the new location.
For long distances, including those involving transportation in a vehicle,
place your Hitachi Simple Modular Storage 100 in its original packing
material and shipping container.
After Your Array is in the New Location
Complete the following tasks in order.
Connect all data and power cables to your Hitachi Simple Modular
Storage 100.
Make sure that your Hitachi Simple Modular Storage 100 is set up
correctly.
Make sure your applications and users can access data through your
Hitachi Simple Modular Storage 100.
Make sure your Hitachi Simple Modular Storage 100 can be accessed
using Storage Navigator Modular 2.
4–8Maintaining Your Array
Hitachi Simple Modular Storage 100 User’s Guide
Storing Your Hitachi Simple Storage Modular 100
Read this section if you turn your Hitachi Simple Modular Storage 100 on
and off for extended periods.
If your Hitachi Simple Modular Storage 100 is removed from an AC power
supply longer than six months, its internal battery will become over
discharged and unrecoverably damaged, and you will need to replace yo ur
array. To avoid this situation, connect your Hitachi Simple Modular Stor age
100 to an AC outlet for more than six hours at least once every six months
so the battery can be charged.
Maintaining Your Array4–9
Hitachi Simple Modular Storage 100 User’s Guide
4–10Maintaining Your Array
Hitachi Simple Modular Storage 100 User’s Guide
5
Troubleshooting
This chapter provides information to help you identify and resolve
problems in the unlikely event you encounter a problem with your
Hitachi Simple Modular Storage 100 array.
Troubleshooting5–1
Hitachi Simple Modular Storage 100 User’s Guide
Recovering from Failures
An array failure may have occurred if one or more of the following occurs:
•Y our Hitachi Simple Modular Storage 100 sends an email alerting you to
a failure.
•The Alarm or Warning LED on the front panel goes ON.
•The Ready LED on the front panel is OFF.
•You experience performance deterioration with your Hitachi Simple
Modular Storage 100.
•A LUN cannot be recognized.
•A host cannot see an iSCSI data port on your Hitachi Simple Modular
Storage 100.
If one or more of these actions occurs, perform the following steps to
recover form the failure:
1. Log in to Storage Navigator Modular 2:
http://<IP address of management console PC>:23015/
StorageNavigatorModular/
2. Go to the Explorer pane and click Arrays.
•
NOTE: If Storage Navigator Modular 2 does not start, a communication
failure with the Storage Navigator Modular 2 server may have occurred or
the Storage Navigator Modular 2 server may not be started normally. See
“Hitachi Storage Navigator Modular 2 will not start” in Table 5-1 o n page 5-
5.
3. In the Arrays area, check the status and serial number of the array
where the failure occurred (see Figure 5-1 on page 5-3).
5–2Troubleshooting
Hitachi Simple Modular Storage 100 User’s Guide
•
Figure 5-1: Locating the Array Name and Serial Number
NOTE: If Storage Navigator Modular 2 cannot access your Hitachi Simple
Modular Storage 100, the array may be turned off or there may be a
network failure between Storage Navigator Modular 2 and the array. See
“Hitachi Storage Navigator Modular 2 cannot communicate with the array”
in Table 5-1 on page 5-5.
4. If you received an email about the failure or used SNMP to detect the
failure, check that the hardware serial number in the email/SNMP
matches the one on your Hitachi Simple Modular Storage 100 (see
Figure 4-2 on page 4-3).
5. Check the status column of the system that matches the hardw are serial
number checked in the previous step.
• Normal = Your Hitachi Simple Modular Storage 100 is operating
normally. The fault may have occurred between the array and the
host. See “A failure other than an array failure occurs” in Table 5-
1 on page 5-5.
• --- = Sto rage Navigator Modular 2 cannot access your Hitachi
Simple Modular Storage 100. The MAIN SW switch may be set to
the OFF position or a network failure may have occurred between
the host and the array.See “Hitachi Storage Navigator Modular 2
cannot communicate with the array” in Table 5-1 on page 5-5.
6. From the Arrays area shown in Figure 5-1, click the name of the array.
When the next screen appears, click either Alerts & Events in the
Arrays pane or Check for Errors in the Common Array Tasks area. In
the Alert Parts tab, check for the failed part, such as a disk drive (see
Figure 5-2 on page 5-4).
• If a disk drive is shown, do not try to remove the faulty drive. Your
Hitachi Simple Modular Storage 100 is designed to prevent drives
form being removed. However, you can insert up to two spare
drives.
Troubleshooting5–3
Hitachi Simple Modular Storage 100 User’s Guide
• If your Hitachi Simple Modular Storage 100 is shown, the array is
faulty and should be replaced.
• If neither appears in the failure list window, a software failure may
have occurred. See “Unidentified failure has occurred” Table 5-1 on
page 5-5.
•
Figure 5-2: Example of the Failure Parts List Tab
7. If an entry appears in the failure parts list window, click Show Details
in the lower right corner of the screen for detailed information (see
Figure 5-3 on page 5-5). To remove the information, click the Close
button.
5–4Troubleshooting
Hitachi Simple Modular Storage 100 User’s Guide
•
Click
Information for order
Figure 5-3: Example of an Alarm Information Window
Troubleshooting Your Array
Table 5-1: Troubleshooting
SymptomSuggested Actions
Missing or damaged partsIf any of the contents included with your Hitachi Simple
Modular Storage 100 are missing or damaged, contact
your place of purchase immediately.
Power LED does not go ON1. Check that the power connections to your Hitachi
Simple Modular Storage 100 are secure.
2. Verify that the power outlet is working. Plug a lamp
into the outlet to determine whether the outlet is
working.
3. If the outlet is controlled by a wall switch, be sure the
switch is set to provide power to the outlet. We
recommend you use a power outlet not controlled by
a wall switch.
4. If these steps do not fix the problem, visit the Hitachi
Web Portal at http://support.hds.com.
Troubleshooting5–5
Hitachi Simple Modular Storage 100 User’s Guide
Table 5-1: Troubleshooting (Continued)
SymptomSuggested Actions
Host cannot access storage1. Verify that the port activity LED on the used iSCSI
data ports is ON (see Figure 2-3 on page 2-4). If not,
try a different iSCSI data port.
2. Check that all iSCSI cables are connected securely at
both ends.
3. Send a ping command from the host to your Hitachi
Simple Modular Storage 100. If the ping fails, verify
that the host is communicating with your Hitachi
Simple Modular Storage 100 at the appropriate IP
address.
4. Check whether other devices in your network, such as
a router or switch, are the cause of the problem.
5. If these steps do not fix the problem, visit the Hitachi
Web Portal at http://support.hds.com.
A failure other than an array failure occurs 1. Check that the host is turned on.
2. Verify that the port activity LED on the used iSCSI
data ports is ON (see Figure 2-3 on page 2-4). If not,
try a different iSCSI data port.
3. Send a ping command from the host to your Hitachi
Simple Modular Storage 100. If the ping fails, verify
that the host is communicating with your Hitachi
Simple Modular Storage 100 at the appropriate IP
address.
4. Check your CHAP authentication, LUN Manager,
mapping, and LUN settings.
Hitachi Storage Navigator Modular 2 will
not start
1. Be sure the computer acting as the management
console meets the minimum requirements described
in Required Items Supplied by the User on page 3-8.
2. Check the settings of your Web browser.
3. Verify that the Storage Navigator Modular 2 server is
working.
4. Verify that your host has Java Runtime Environment
(JRE) version 1.6 (update 2) installed. This is a free
download from http://java.sun.com/javase/
downloads/index.jsp.
5. Verify that the correct IP address was entered in the
Web browser address bar.
6. If these steps do not fix the problem, you may need
to reinstall the Storage Navigator Modular 2 software.
5–6Troubleshooting
Hitachi Simple Modular Storage 100 User’s Guide
Table 5-1: Troubleshooting (Continued)
SymptomSuggested Actions
Hitachi Storage Navigator Modular 2
cannot communicate with the array
Array or part has failed1. Start Storage Navigator Modular 2. If it fails to start,
Unidentified failure has occurred1. If using preinstalled Hitachi software (see Key
1. Check that both power cables are connected to the
array and to working AC outlets, and that the
Power LEDs above each receptacle on the back panel
are blinking.
2. Check that the MAIN SW switch on both arrays is in
the ON position.
3. Check that the Power and EXT LEDs on both arrays
are ON.
4. Check whether other devices in your network, such as
a router or switch, is the cause of the problem.
5. Turn off your Hitachi Simple Modular Storage 100.
Verify that the front panel Power LED goes OFF. If the
Power LED is ON, disconnect both power cables and
verify that the front panel Power LED is OFF.
6. Turn on y our Hitachi Simple Modular Storage 100 and
verify that the Ready LED goes ON.
7. Repeat steps 4 and 5 again.
8. If these steps do not resolve the problem, see Array
or part has failed, below.
see Unidentified failure has occurred, below.
2. Go to the Explorer pane and select Resources > Arrays.
3. In the Arrays pane, check for a failed array . If you find
one, select Components > Trays.
4. From the Alerts screen, click the Details button to
check for additional failed parts.
5. Read any detailed information about the failed part.
6. If the failed component is a drive, order a
replacement drive from the Hitachi Web Portal at
http://support.hds.com.
Features on page 1-2), refer to the documentation for
that product.
2. Turn off your Hitachi Simple Modular Storage 100.
Verify that the front panel Power LED goes OFF. If the
Power LED is ON, disconnect both power cables and
verify that the front panel Power LED is OFF.
3. Turn on y our Hitachi Simple Modular Storage 100 and
verify that the Ready LED goes ON.
4. If these steps do not resolve the problem, see Array
or part has failed above.
Troubleshooting5–7
Hitachi Simple Modular Storage 100 User’s Guide
Table 5-1: Troubleshooting (Continued)
SymptomSuggested Actions
Auto migration or data shredding
operation has failed
An error message appears in Storage
Navigator Modular 2 during auto
migration
The array went down during the auto
migration procedure.
1. If a auto migration or data shredding operation has
failed, an error message appears in the Error field of
the Array Migration window.
2. Confirm that the auto migration cables are connected
properly.
3. Confirm that the target array is in migration mode
(MODE switch is in the E position).
4. Connect the target array again.
5. Only one migration operation can be performed on an
array. If the array has already been used as a target
in an array migration, it cannot be used as a target
array again.
6. If the problem persists, visit the Hitachi Web Portal at
http://support.hds.com.
Please see Table 5-2 on page 5-10 for troubleshooting
suggestions.
1. Move the MAIN SW switch on the back panel of the
source array to the OFF position. Verify that the
POWER LED goes OFF.
2. Move the MAIN SW switch on the back panel of the
target array to the OFF position. Verify that the EXT
and POWER LEDs go OFF.
3. Remove the migration cable between the source and
target arrays.
4. Move the MAIN SW switch on the back panel of the
source array to the ON position and verify that the
POWER LED goes ON.
If array down condition occurs again when starting the
source array , turn off the source arra y again and then turn
it on. Check that the READY LED goes ON after a few
minutes. If the READY LED does not go ON after 20
minutes, visit the Hitachi Web Portal at http://
support.hds.com.
5–8Troubleshooting
Hitachi Simple Modular Storage 100 User’s Guide
Table 5-1: Troubleshooting (Continued)
SymptomSuggested Actions
Before you perform an array migration,
you may want to test the new target array
by writing data to it. When you write data
to the array, the array’s migration guard
becomes enabled automatically. This
safety feature prevents an array that
contains data from being overwritten.
Therefore, to use an array with data as a
target array in a data migration operation,
you must first release the migration guard
using the suggested actions to the right to
allow the data on that array to be
overwritten.
1. Move the MAIN SW switch on the back panel of the
source array to the OFF position. Verify that the
POWER LED goes OFF.
2. Move the MAIN SW switch on the back panel of the
target array to the OFF position. Verify that the EXT
and POWER LEDs go OFF.
3. Remove the migration cable between the source and
target arrays.
4. Connect your storage network to the management
port on the target array.
5. On the target array, set the MODE switch to N.
6. Move the MAIN SW switch on the back panel of the
source array to the ON position. Verify that the
POWER LED goes ON and that the READY LED goes
ON in a few minutes.
7. Log in to Storage Navigator Modular 2.
8. In the Arrays area, click the Add Array button and
add the array to the Storage Navigator Modular 2
database.
9. Go to Settings > Replacement of Array and select
Check for New Array.
10. A status of Guarded means the release migration
guard is enabled. T o disable the migration guard, click
Release Migration Guard in the Migration Guard
Setting to acknowledge that the array can be
overwritten. A confirmation dialog box appears.
11. Click the checkbox, then click OK to continue.
12. Move the MAIN SW switch on the back panel of the
target array to the OFF position. Verify that the
POWER LED goes OFF.
13. Remove the cable from the management port of the
target array.
14. Return the MODE switch on the target array to the E
position.
15. Connect the auto migration cables to the source and
target arrays.
16. Move the MAIN SW switch on the back panel of the
target array to the ON position. Verify that the EXT
and POWER LEDs go ON.
17. Move the MAIN SW switch on the back panel of the
source array to the ON position. Verify that the
POWER LED goes ON and that the READY LED goes
ON in a few minutes.
18. Perform the auto migration operation described in the
Hitachi Simple Modular Storage 100 Auto Migration
Assistant Guide (MK-97DF8066).
Troubleshooting5–9
Hitachi Simple Modular Storage 100 User’s Guide
Table 5-2: Auto Migration Troubleshooting
Error MessageSuggested Actions
Restore is in progress on ShadowImage pairs Wait until restore is completed and try Create Copy
again.
Restore is in progress on SnapShot pairsWait until restore is completed and try Create Copy
again.
Unreadable PIN exists in the source arrayAuto migration cannot be performed. Visit the Hitachi
Web Portal at http://support.hds.com.
Quick Format is in progressWait until the quick format is completed and try Create
Copy again.
No DM-LUN exists in the source arrayAuto migration cannot be performed. Visit the Hitachi
Web Portal at http://support.hds.com.
Cache resident LUN exists in the source
array
Change on cache partition is reservedShut down and restart the source array. Then try the
PIN over has occurred in the source arrayAuto migration cannot be performed. Visit the Hitachi
FAN in the target array is in Alarm statusDisconnect the target array as described on the next
The power supply in the target array is in
Alarm status
HDU in the target array is in Alarm statusDisconnect the target array as described on the next
ENC in the target array is in Alarm statusDisconnect the target array as described on the next
The type of HDDs in the target array is
incorrect
The number of HDDs in the target array is
incorrect
The capacity of HDDs in the target array is
insufficient
The target array is guarded against array
migration
The controller configuration of the target
array is incorrect
Disable Cache Resident LUN and try the auto migration
again.
auto migration again.
Web Portal at http://support.hds.com.
page and start it in normal mode to see if the alarm
disappears. If the alarm message disappears, try the
auto migration again. Otherwise, visit the Hitachi Web
Portal at http://support.hds.com.
Disconnect the target array as described on the next
page and start it in normal mode to see if the alarm
disappears. If the alarm message disappears, try the
auto migration again. Otherwise, visit the Hitachi Web
Portal at http://support.hds.com.
page and start it in normal mode to see if the alarm
disappears. If the alarm message disappears, try the
auto migration again. Otherwise, visit the Hitachi Web
Portal at http://support.hds.com.
page and start it in normal mode to see if the alarm
remains. If the alarm message disappears, try Array
Migration again. Otherwise, visit the Hitachi Web Portal
at http://support.hds.com.
Visit the Hitachi Web Portal at http://support.hds.com.
Visit the Hitachi Web Portal at http://support.hds.com.
Visit the Hitachi Web Portal at http://support.hds.com.
Disconnect the target array as described on the next
page and start it in normal mode to confirm if it can be
the target array. If it can, try the auto migration again.
Visit the Hitachi Web Portal at http://support.hds.com.
5–10Troubleshooting
Hitachi Simple Modular Storage 100 User’s Guide
Table 5-2: Auto Migration Troubleshooting
Error MessageSuggested Actions
The new target array has an earlier firmware
version than the source array
The type of interface boards in the target
array is incorrect
The number of interface boards in the target
array is incorrect
The bandwidth of interface boards in the
target array is insufficient
An incorrect array is connectedV isit the Hitachi Web Portal at http://support.hds.com.
Failure has occurred in the source arrayShut down and restart the source array. Restart the
Failure has occurred in the target arrayShut down and restart the source array. It is possible to
Intermittent failure has occurred in the
source array
Failure has occurred in the source arrayThe data shredding operation has failed. Return the
Unexpected error has occurredVisit the Hitachi Web Portal at http://support.hds.com.
Disconnect the target array as described below and start
it in normal mode to upgrade the firmware to the same
or later version as the source array. Then try the auto
migration again.
Visit the Hitachi Web Portal at http://support.hds.com.
Visit the Hitachi Web Portal at http://support.hds.com.
Visit the Hitachi Web Portal at http://support.hds.com.
source array. When the Ready LED goes ON, perform
the migration again. If the Ready LED does not go ON,
visit the Hitachi Web Portal at http://support.hds.com.
use the source array after reboot. If the problem
persists, visit the Hitachi Web Portal at http://
support.hds.com to obtain a target array.
Click Switch Array in the Array Migration window.
source array, without trying to shred the data.
Troubleshooting5–11
Hitachi Simple Modular Storage 100 User’s Guide
5–12Troubleshooting
Hitachi Simple Modular Storage 100 User’s Guide
A
Upgrading Firmware
Your Hitachi Simple Modular Storage 100 array can use newer
versions of its firmware as they become av ailable. This appendix
describes how to upgrade the firmware on your Hitachi Simple
Modular Storage 100. This procedure requires the use of Storage
Navigator Modular 2.
1. Download the latest firmware.
2. Start your web browser and log in to Storage Navigator
Modular 2:
http://<IP address of management console PC>:23015/
StorageNavigatorModular/
3. In the Explorer pane, click Resources > Arrays.
4. In the Arrays area, check the array whose firmware you want
to upgrade, then click Show & Configure Array.
•
A screen similar to the following appears.
•
Hitachi Simple Modular Storage 100 User’s Guide
A–1
•
5. Under Common Array Tasks, click Update Microprogram. The
following window appears.
•
A–2
6. Next to Update operatio n, click Update microprogram.
7. Next to Update file path, click the Browse button, navigate to the
location where the firmware file resides, click the file, and click the Open
button. The path and filename appear in the Browse field.
8. Click OK. The following confirmation window appears.
Hitachi Simple Modular Storage 100 User’s Guide
•
9. Read the information in the window. Then check Yes, I have read the above warning and agree to update the Microprogram.
10.Click the Confirm button to proceed. A window similar to the following
appears as the firmware is updated. The window shows the approximate
duration required to update the firmware.
•
NOTE: On arrays with one controller, the Warning LED flashes when the
firmware is being updated.
•
CAUTION!Do not cancel or have your Hitachi Simple Modular
Storage 100 perform I/O operations while the firmware is being
upgraded.
11.After the firmware has been updated, a message informs you that the
operation has been completed successfully. Click the Close button to
remove the message. You can then return to normal operation.
Hitachi Simple Modular Storage 100 User’s Guide
A–3
A–4
Hitachi Simple Modular Storage 100 User’s Guide
B
Specifications
This appendix lists the specifications for your Hitachi Simple
Modular Storage 100 array.
Depth: 28.7 inches (731.4 mm)
WeightApprox 72.6 pounds (33 kg)
Acoustic NoiseApproximately 60 dB
Insulation to Withstand VoltageAC 1,500 V (10 mA, 1 min)
Insulation ResistanceDC 500 V, 10 M Ω or more
Table B-4: Cache Specifications
ParameterSpecification
Capacity1,024 Mbytes
Control MethodRead LRU/Write after
Battery BackupProvided
Backup Duration24 hours with 1 G bytes cache /controller
Electrical Specifications
The following table describes the electrical specifications for the Hitachi
Simple Modular Storage
Table B-5: Input Specifications
ParameterSpecification
Input VoltageAC 100/200 V
Frequency50/60 Hz ±1
Number of Phases, CablingSingle-phase with Protective Grounding
Steady-state Current3.2 2/1.6 2
Breaking Current10.0
Heat Value2,160 kj/h or less
Required PowerSteady State (VA): 640 or less
•
.
(100 V to 120/200 V to 240 V)
Starting State (VA): 640 or less
Hitachi Simple Modular Storage 100 User’s Guide
B–3
Environmental Specifications
The following table describes the environmental specifications for the
Hitachi Simple Modular Storage.
Table B-6: Environmental Specifications
ParameterSpecification
Temperature, Operating50° F to 104° F (10° to 40° C)
Temperature, Storage14° F to 122° F (–10° to 50° C)
Temperature, Transporting–22° F to 140° F (–30° to 60° C)
Temperature Change Rate50° F (10°C) per hour
Humidity, Operating46° F to 176° F (8° to 80° C)
Humidity, Storage46° F to 194° F (8° to 90° C)
Maximum Wet Bulb Temperature84° F (29° C) noncondensing
Vibration, Operating (m/s2)2.5 or less (5 to 300Hz) (within 5 seconds)
Vibration, Storage (m/s2)5.0 or less (5 to 300Hz)
Vibration, Transporting (m/s2)5.0 or less
Impact, Operating (m/s2)20 or less (10 ms, half sine wave impact)
Impact, Storage (m/s2)50 or less (10 ms, half sine wave impact)
Impact, Transporting (m/s2)80 or less (10 ms, half sine wave impact)
Altitude, Operating–984.25 to 9842 feet (–300 to 3,000 m)
Altitude, Storage-300 to 12,000
Acoustic Noise60 dB (environmental temperature: 32°C
or less)
Power Cables
Table B-7: Power Cable and Plug Identification
Input Rating
100V-120V
(standard
attachment)
200V-240V
Configuration
North America
North America
Plug
Reference
Standards
1 ANSI C73.11
2 NEMA 5-15P
3 IEC 83
1 ANSI C73.11
2 NEMA 6-15P
3 IEC 83
Cable and Connector
ab
c
Three wire power cable
with a two-pole, threeterminal groundingtype connector.
B–4
Hitachi Simple Modular Storage 100 User’s Guide
Table B-7: Power Cable and Plug Identification
Input Rating
Plug
Configuration
Universal Euro
United Kingdom
Australia
Reference
Standards
4 CEE (7)
II, IV, VII
3 IEC 83
5 BS 1365
3 IEC 83
6 AS C112
Cable and Connector
23mm
Hitachi Simple Modular Storage 100 User’s Guide
B–5
Ethernet Specifications
The following table describes the Ethernet specifications for the Hitachi
Simple Modular Storage.
Table B-8: Ethernet Specifications
ParameterSpecification
Works with switches that comply to the
following standards:
Figure B-2: RJ-45 Jack on the Hitachi Simple Modular Storage 100
Hitachi Simple Modular Storage 100 User’s Guide
Glossary
This glossary provides definitions of general storage networking
terms as well as specific terms related to the technology that
supports your Hitachi Simple Modular Storage 100 array. Click
the letter of the glossary section to display that page
•
#ABCDE FGHIJKLMNO PQRSTUVWXY Z
Glossary–1
Hitachi Simple Modular Storage 100 User’s Guide
#
1000Base-T
A specification for Gigabit Ethernet over copper wire. The standard
defines 1 Gbps data transfer over distances of up to 100 meters using
four pairs of Category 5 balanced copper cabling and a 5-level coding
scheme.
A
Array
A set of hard disks grouped logically together to function as one
contiguous storage space.
ATA
Advanced Technology Attachment, a disk drive implementation that
integrates the controller on the disk drive.
B
BIOS
Basic Input Output System, built-in software code that determines the
functions that a computing device can perform without accessing
programs from a disk.
Bps
Bits per second, the standard measure of data transmission speeds.
C
Cache
A temporary , high-speed stor age mechanism. It is a reserved section of
main memory or an independent high-speed storage device. Two types
of caching are found in computers: memory caching and disk caching.
Memory caches are built into the architecture of microprocessors and
often computers have external cache memory. Disk caching works like
memory caching; however, it uses slower, conventional main memory
that on some devices is called a memory buffer.
Capacity
The amount of information (usually expressed in megabytes) that can
be stored on a disk drive. It is the measure of the potential contents of
a device; the volume it can contain or hold. In communications,
capacity refers to the maximum possible data transfer rate of a
communications channel under ideal conditions.
•
#ABCDE FGHIJKLMNO PQRSTUVWXY Z
Glossary–2
Hitachi Simple Modular Storage 100 User’s Guide
Challenge Handshake Authentication Protocol
A security protocol that requires users to enter a secret for access.
CHAP
See Challenge Handshake Authentication Protocol.
D
DHCP
Dynamic Host Configuration Protocol, allows a computer to join an IPbased network without having a pre-configured IP address. DHCP is a
protocol that assigns unique IP addresses to devices, then releases and
renews these addresses as devices leave and re-join the network.
Duplex
The transmission of data in either one or two directions. Duplex modes
are full-duplex and half-duplex. Full-duplex is the simultaneous
transmission of data in two direction. F or example, a telephone is a fullduplex device, because both parties can talk at once. In contrast, a
walkie-talkie is a half-duplex device because only one party can
transmit at a time.
F
Fabric
The hardware that connects workstations and servers to storage
devices in a SAN. The SAN fabric enables any-server-to-any-storage
device connectivity through the use of Fibre Channel switching
technology.
Firmware
Software embedded into a storage device. It may also be referred to as
Microcode.
FUll-duplex
The concurrent transmission and the reception of data on a single link.
G
Gbps
Gigabit per second.
•
#ABCDFGHI JKLMNO PQRSTUVWXYZ
Glossary–3
Hitachi Simple Modular Storage 100 User’s Guide
H
HBA
Host bus adapter, a circuit board and/or integrated circuit adapter
installed in a workstation or server that provides input/output
processing and physical connectivity between a server and a storage
device. An iSCSI HBA implements the iSCSI and TCP/IP protocols in a
combination of a software storage driver and hardware.
HDD
Hard disk drive.
I
Initiator
A system component that originates an I/O command over an I/O bus
or network, such as an I/O adapters or network interface cards.
I/O
Input/output.
IP
Internet Protocol, specifies the format of packets and addressing
scheme. Most networks combine IP with a higher-level protocol called
Transmission Control Protocol (TCP), which establishes a virtual
connection between a destination and a source.
IP address
An identifier for a computer or device on a TCP/IP network. Networks
using the TCP/IP protocol route messages based on the IP address of
the destination. The format of an IP address is a 32-bit numeric
address written as four numbers separated by periods. Each number
can be zero to 255 (for example, 192.168.0.200).
IP-SAN
Block-level Storage Area Networks over TCP/IP using the iSCSI
protocol.
iSCSI
Internet SCSI, an IP-based standard for connecting data storage
devices over a network and transferring data using SCSI commands
over IP networks. iSCSI enables a Storage Area Network to be
deployed in a Local Area Network.
•
#ABCDE FGHIJKLMNO PQRSTUVWXY Z
Glossary–4
Hitachi Simple Modular Storage 100 User’s Guide
iSNS
Internet Storage Name Service, a protocol that allows automated
discovery, management and configuration of iSCSI devices on a T CP/IP
network.
L
LAN
Local Area Network, a computer network that spans a relatively small
area, such as a single building or group of buildings.
LU
Logical unit.
LUN
Logical unit number.
M
Middleware
Software that connects two otherwise separate applications. For
example, a middleware product can be used to link a database system
to a Web server. Using forms, users request data from the database;
then, based on the user's requests and profile, the Web server returns
dynamic Web pages to the user.
N
NIC
Network Interface Card, an expansion board in a computer that allows
the computer to connect to a network
R
RAID
Redundant Array of Independent Disks, a disk array in which part of the
physical storage capacity is used to store redundant information about
user data stored on the remainder of the storage capacity. The
redundant information enables regeneration of user data in the event
that one of the array's member disks or the access path to it fails.
SNIA.
•
#ABCDFGHI JKLMNO PQRSTUVWXYZ
Glossary–5
Hitachi Simple Modular Storage 100 User’s Guide
RAID 6
An extension of the RAID 5 array, that allows for two simultaneous
drive failures without downtime or data loss.recovery point objective
(RPO)
After a recovery operation, the recovery point objective (RPO) is the
maximum desired time period, prior to a disaster, in which changes to
data may be lost. This measure determines up to what point in time
data should be recovered. Data changes preceding the disaster are
preserved by recovery.
S
SAN
Storage Area Network, a network of shared storage devices that
contain disks for storing data.
SAS
Serial Attached SCSI, an evolution of parallel SCSI into a point -to-point
serial peripheral interface in which controllers are linked directly to disk
drives. SAS delivers improved performance over traditional SCSI
because SAS enables up to 128 devices of different sizes and types to
be connected simultaneously.
SATA
Serial ATA is a computer bus technology primarily designed for the
transfer of data to and from hard disks and optical drives. SATA is the
evolution of the legacy Advanced Technology Attachment (ATA)
interface from a parallel bus to serial connection architecture.
SCSI
Small Computer System Interface, a parallel interface standard that
provides faster data transmission rates than standard serial and parallel
ports.
Session
A series of communications or exchanges of data between two end
points that occurs during the span of a single connection. The session
begins when the connection is established at both ends, and terminates
when the connection is ended. For some applications each session is
related to a particular port. In this document a session is the exchange
of data between groups of primary and secondary volumes.
SMTP
Simple Mail Transfer Protocol, a protocol used to receive and store
email data directly from email servers.
•
#ABCDE FGHIJKLMNO PQRSTUVWXY Z
Glossary–6
Hitachi Simple Modular Storage 100 User’s Guide
Software initiator
A software application initiator communicates with a target device. A
software initiator does not require specialized hardware because all
processing is done in software, using standard network adapters.
Storage Navigator Modular 2
A multi-featured scalable storage management application that is used
to configure and manage the storage functions of Hitachi arrays. Also
referred to as “Navigator 2".
Subnet
In computer networks, a subnet or subnetwork is a range of logical
addresses within the address space that is assigned to an organization.
Subnetting is a hierarchical partitioning of the network address space of
an organization (and of the network nodes of an autonomous system)
into several subnets. Routers constitute borders between subnets.
Communication to and from a subnet is mediated by one specific port
of one specific router, at least momentarily. SNIA.
Switch
A network infrastructure component to which multiple nodes attach.
Unlike hubs, switches typically have internal bandwidth that is a
multiple of link bandwidth, and the ability to rapidly switch node
connections from one to another. A typical switch can accommodate
several simultaneous full link bandwidth transmissions between
different pairs of nodes. SNIA.
T
Target
Devices that receive iSCSI requests that originate from an iSCSI
initiator.
TOE
A dedicated chip or adapter that handles much of the TCP/IP processing
directly in hardware. TCP/IP transmission is inherently a CPU-intensive
operation. Therefore, using dedicated hardware that can operate in
parallel with the main processor allows for superior system
performance. Although all iSCSI HBAs have a TOE, a generic TOE only
implements TCP/IP, while an iSCSI HBA implements the iSCSI protocol
in addition to TCP/IP.