Hitachi RAS-ME14HA, RAC-ME10HZ, RAS-ME10HA, RAS-MES10HA, RAS-MES14HA Installation Manual

...
Screw for Hanger
(Φ4x35)
HITACHI SPLIT-UNIT AIR CONDITIONER
INSTALLATION MANUAL
+ – Screwdriver Measuring Tape Knife Saw ø 65mm Power Drill Allen Key ( 4mm) Wrench (14, 17, 19, 22mm) Gas Leakage Detector Pipe Cutter Plastic Tape Pliers Flare Tool
Carefully read through the procedures of proper installation before starting installation work. The sales agent should inform customers regarding the correct operation of installation.
Tools Needed For Installation Work
SAFETY PRECAUTION
Read the safety precautions carefully before operating the unit. The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING ........ Incorrect methods of installation may cause death or serious injury.
CAUTION ......... Improper installation may result in serious consequence.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit as described in the user’s guide.
Be sure to use the earth line. Do not place earth line near gas or water pipes, lightning conductor and the earth line of telephone. Improper earthing may cause electric shocks.
A circuit breaker should be installed depending on the mounting size of the unit. Without a circuit breaker, the danger of electric shock exists.
Do not install the unit near a location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose.
Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the installation work yourself.
Please observe the instructions stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric shock and fire.
Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and impose danger.
Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical work. Use wire which is specified for the air conditioner. A short circuit and fire may occur due to the use of low quality wire or improper work.
Be sure to use the specified wire for connecting the indoor and outdoor units. Please ensure that the connections are tight after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact may cause over-heating and fire.
Please use the specified components for installation work. Otherwise, the units may collapse or water leakage, electric shock and fire may occur.
Do not mix any coolant other than R-22 into the cooling
circulation path when mounting or shifting the unit. If it is mixed with air, the high pressure in the circulation path will rise and this may result in broken copper pipes or faults.
THE CHOICE OF MOUNTING SITE (Please note the following matters and obtain permission from customer before installation).
The unit should be mounted at stable, non-vibratory location which can provide full support to the unit.
The outdoor unit must be mounted at a location which can sup­port heavy weight. Otherwise, noise and vibration will increase.
No nearby heat source and no obstruction near the air outlet is allowed. The clearance distances from top, right and left are specified in figure below. The location must be convenient for water drainage and pipe connection with the Outdoor unit. To avoid interference from noise please place the unit and its remote controller at least 1m from the radio, television and inverter type fluorescent lamp. To avoid any error in signal transmission from the remote controller, please put the controller far away from high-frequency machines and high-power wireless systems. The installation height of indoor unit must be 2.3m or more in a non public area.
Do not expose the unit under direct sunshine or rain. Besides, ventilation must be good and clear of obstruction. The air blown out of the unit should not point directly to animals or plants. The clearances of the unit from top, left, right and front are specified in figure below. At least three of the above sides must be open air. Be sure that the hot air blown out of the unit and noise do not disturb the neighbourhood. Do not install at a location where there is flammable gas, steam, oil and smoke. The location must be convenient for water drainage. Place the outdoor unit and its connection wire at least 1m away from the antenna or signal line of television, radio or telephone. This is to avoid noise interference.
TINUROODNI
Names of Indoor Components
The Length of Indoor Unit
Power Cord
Do not alter the power cord.
Direction of Piping
Figure showing the Installation of Indoor and Outdoor Unit.
TINUROODTUO
There are 4 directions allowed, namely, horizontally perpendicular to the unit, vertically down from right, horizontally out from right and horizontally out to left. Don't form the piping downward at the left of the unit.
Installation of Mounting Plate, Wall Penetration and Installation of Protection Pipe
1
The draining of the water container inside the indoor unit can be done from the left. Therefore the mounting plate must be fixed horizontally or slightly tilted towards the side of drain hose. Otherwise, condensed water may overflow the water container.
Direct Mounting On The Wall
Please use hidden beams in the wall to hold the mounting plate.
Wall Penetration and Installation of Protection Pipe
Drill a ø 65mm hole on wall which is slightly tilted towards the outdoor side. Drill the wall at a small angle. Cut the protection pipe according to the wall thickness. Empty gap in the sleeve of protection pipe should be completely sealed with putty to avoid dripping of rain water into the room.
Procedures of Installation and Precautions
Procedures to fix the mounting plate.
1.Drill holes on wall. 2.Fix the mounting plate on (As shown below)
wall with 4.1 x 32 screw (As shown in figure below)
Installation of the Indoor Unit
2
VERTICALLY DOWNWARD PIPING
Preparation
Connect power cord. Pull out the pipe, power cord and drain hose.
Installation
The upper part of the indoor unit is hanged on the mounting plate. The projection at the lower part of the indoor unit is hooked onto the mounting plate.
Please pull the lower part of the indoor unit outwards to check if the unit is hooked onto the mounting plate. Improper installation may cause vibration and noise.
HORIZONTAL PIPING
Preparation
Change of Drain Hose and Installation Procedures.
Exchange the location of drain hose and drain cap during horizontal piping as shown in figure below. Be sure to plug in the drain hose until the insulating material folds upon itself.
Please use pliers to pull out the drain cap. (This is an easier way to remove the drain cap).
HORIZONTAL & DOWNWARD PIPING – MAKING OPENINGS
During horizontal or downward piping, use a knife to cut openings as shown in figure. Then smoothen the edges of openings with a file.
INSTALLATION OF COOLANT PIPES AFTER CONNECTION
The coolant pipes should be adjusted to fit into the hole on the wall and then ready for further connection. The terminals of 2 connected pipes must be covered with insulator used for terminal connection. Connect the power cord. After adjustment, fit the power cord and pipes into the space available under the indoor unit.
The rubber strap used for fixing the insulator should not be tied with great force. Otherwise, this will damage heat insulation and causes water condensation.
THE CONNECTION OF COOLANT PIPE DURING THE INSTALLATION OF INDOOR UNIT
Preparation To Install Coolant Pipes
Please fix in the plastic core after flaring to avoid plastic chips entering the pipes.
CAUTION
You are free to choose the side (left or right) for the installation of drain hose. Please ensure the smooth flow of condensed water of the indoor unit during installation. (Carelessness may result in water leakage.)
Be sure that the drain hose is not loosely connected or bent.
Be sure that the wire is not in contact with any metal in the wall. Please use the protection pipe as wire passing through the hollow part of the wall so as to prevent the possibility of damaged by mouse.
Coolant pipes and power cord must be tied together. The front part of the coolant pipes are at locations marked with “ ” symbol.
Installation of Drain Hose
3
Pull this to the front during the connection of coolant pipes to ease task.
Installation
Hang the indoor unit onto the mounting plate. Use the temporary stand at the back of the indoor unit to push its lower part 15cm forwards.
Place the drain hose through the hole on the wall. Insulate the connecting portion of coolant pipe with insulator. Connect the power cord. After adjustment, the power cord and coolant pipes are placed into the space available under the indoor unit. The projection of indoor unit must hook to the mounting plate.
TINUROODNI
AAA Size Battery
Hanger
QtyNo. Component’s Name
1
6
2
Remote Controller
Bush
about 1.6m
about
0.9m
20
Cut away shaded portion, and finish the edge of the opening so that there is no burr.
Connection
Horizontally perpendicular to the unit
Pipe
Power cord
Drain hose
Pipe
Rubber strap tied with great force
Pipe
below 5mm
Please bend at a small radius to form an arc
about 15cm
Projection
Temporary stand
Hook
Power cord
Protection pipe
Drain hose
Connected terminals of coolant pipes
Coolant pipes
Power cord
Heat insulation pipe
Bending upwards
Stagment water
Drain
Stagment water
Openings
Drain cap
Please insert until here
Drain hose
Please insert until here
Mounting Plate
Hook
Coolant pipe
Power Cord
Drain Hose
Protection Pipe
Lift the body of the unit upwards and then force it downwards.
Mounting Plate
Projection
Power line, pipe and drain hose must be tied together with plastic tape.
2~5mm
Protection pipe
Outdoor
Indoor
Seal with putty
Sleeve of protection pipe
WALL
Remove the cap for drain hose installation
Drain cap
Drain hose
Drain hoseDrain cap
Condensed water may leak out if not inserted properly.
Pipe support
Pull up the pipe after bending downward
Transform the piping while holding down the lower portion of pipe-support by hand.
Indoor Unit
Outdoor Unit
RAS-ME10HZ
RAC-ME10HZ
+
RAS-ME14HZ
RAC-ME14HZ
+
In case the pipe length is more than 5m, add refrigerant R22 at 20 gram (
ME14HZ
)/15 gram (
ME10HZ
) per every meter exceeds.
1
2
3
4
5
1
1
WARNING
CAUTION
WARNING
CAUITON
WARNING
CAUITON
CAUITON
Level
Line
Hole for pipe
Mark
Screw for Mounting plate
Please use more than 4 screws.
Mounting Plate
0.85m
CAUITON
CAUITON
CAUITON
CAUITON
CAUITON
CAUITON
CAUITON
External dimension of
indoor unit
450mm
400mm 316mm
20mm
125mm 44mm
42mm
390mm 530mm 780mm
80mm
65mm
45mm
10mm
65mm
65mm
125mm
199mm
280mm
41mm
45mm
wall nole
wall nole
Drain HoseDrain Hose
Dimension of Mounting Stand of the outdoor unit
500
698
45
300
282
257
The difference in height between the indoor and outdoor unit should be kept below 5m. The connecting pipe, no matter big or small, should all be insulated with insulation pipe and then wrapped with plastic tape. (The insulator will deteriorate if it is not wrapped with tape).
The connection of insulated drain hose.
Please use insulated drain hose for the indoor piping (commercial product).
Be sure to completely seal any gap with putty.
about 0.45m
Maximum pipe
length 10m
above 300mm
must not bend
above 50mm
above 250mm
above 100mm
RAC-ME14HZ
RAC-ME10HZ
ME10HZ
ME14HZ
8m
10m
(For ME10HZ)
(For ME14HZ)
UNIT OUTDOOR
Please mount the outdoor unit on stable ground
There are holes on the base of outdoor unit for condensed water to exhaust.
In order for condensed water to flow to the draining part, installed the unit on the level ground or block so that the unit is 70mm above
the ground,same as figure shown.Join the drain pipe to one hole. At first insert one portion of the hook to the base(Portion A), then pull the drain pipe in the direction shown by the arrow while inserting the hook into the base. After installation, check whether the drain pipe cling to the base firmly.
to prevent vibration and increase of noise level.
Decide the location for piping after sorting out
the different types of pipe available.
Removal Of Air From The Pipe And Gas Leakage Inspection Preparation of Pipe
1
Use a pipe cutter to cut the copper pipe.
Jagged edge will cause leakage. Point the side to be trimmed downwards during trimming to prevent copper chips from entering the pipe.
Before flaring, please put on the hexagon screw cap.
Spanner
Torque wrench
Hexagon screw nut
Pipe Connection
2
Please be careful when bending the copper pipe. Applied frozen grease to the connection points and then screw in manually. After that, use a torque wrench to tighten the connection.
INSTALLATION OF COOLANT PIPES AND AIR REMOV LA
Procedures of using Vacuum Pump for Air Removal
3
REMOVAL AIR
Outer
diameter
of pipe
6.35 (1/4")
9.52 (3/8")
Valve head cap
Valve core cap
Torque N·m
(kgf · cm)
13.7 – 18.6 (140 – 190)
34.3 – 44.1 (350 – 450)
12.7 (4/8") 44.1 – 53.9 (450 – 550)
19.6 – 24.5 (200 – 250)
12.3 – 15.7 (125 – 160)
Small diameter side
Big diameter side
Lo
Hi
As shown in figure on the right, remove the cap of valve head and valve core and then connect them to the vacuum pump and sub-division valve.
Fully tighten the “Hi” shuttle of the sub­division valve and completely unscrew the “Lo” shuttle. Run the vacuum pump for about 10–15 minutes, then completely tighten the “Lo” shuttle and switch off the vacuum pump.
2
Completely unscrew the spindle of the service valve (at 2 places) in anti­clockwise direction to allow the flow of coolant (using Allen key).
3
Remove the connection pipe and tighten the cap of valve head. The task is then completed.
4
Gas Leakage Inspection
Please use gas leakage detector to check if leakage occurs at the connection of hexagon screw nut as shown on the right.
If gas leakage occurs, further tighten the connection to stop leakage.
The body of service valve
Cap of valve core
Allen key
Cap of valve head
Cap of valve head
A
Mould
Mould
Copper pipe
Copper pipe
Trimming tool
Outer
Diameter (ø)
6.35 (1/4")
9.52 (3/8")
Imperial flaring tool
0.8 – 1.5
1.0 – 1.8
Rigid flaring tool
0 – 0.5
12.7 (4/8") 1.2 – 2.0 0 – 1.0
0 – 0.5
A (mm)
1
CONNECTION OF POWER CORD
The naked part of the wire core should be 14 mm and the insulated part of the wire must be push into the terminal for 3 – 4 mm. Then try to pull the individual wire to check if the contact is tight. Improper insertion may burn the terminal. Be sure to use only wire specified for the use of air-conditioner. Please refer to the installation manual for wire connection and the wiring technique should meet the standards of electrical installation. There is a AC voltage drop between the AB terminals if the power is on. Therefore, be sure to remove the plug from its socket.
FINAL STAGE OF INSTALLATION
Insulation And Maintenance Of Pipe Connection
1
The connected terminals should be completed sealed with
heat insulator and then tied up with rubber strap.
Please tie the pipe and power line together with plastic tape
as shown in the figure of installation of both the indoor and
outdoor units. Then fix their position with holders.
To enchance the heat insulation and to prevent water
condensation, please cover the outdoor part of the drain hose
and pipe with insulation pipe.
Completely seal any gap with putty.
Earth Line And Circuit Breaker
2
Power Source And Operation Test
3
The earth line terminal of the outdoor unit is below the service valve. To avoid short circuit, it is necessary to install circuit breaker depending on the mounting location of the unit. Do not place earth line near the following objects: (1) Water pipe (2) Gas pipe — There is danger of catching fire. (3) The earth line of lightning conductor and telephone —
short circuit may occur during lightning.
Power Source
Do not alter the plug of power cord. Do not make extension to the power cord.
Please use a new socket. Accident may occur due to the use of old socket because of poor contact. Please plug in and then remove the plug for 2 – 3 times. This is to ensure that the plug is completely plugged into the socket. Keep additional length for the power cord and do not render the plug under external force as this may cause poor contact. Do not fix the power cord with U-shape nail.
Operation Test
Please ensure that the air conditioner is in normal operating condition during the operation test. Explain to your customer the proper operation procedures as described in the user’s manual.
Insulation material for pipe connection
Sleeve of protection pipe
Putty
WARNING
You may not be able to close the side cover due to the connecting cord, under such situation, please press against the wait of side cover to fix it.
Be sure that the hooks (2 places) are plugged in. Otherwise, water leakage may occur and this causes short circuit or faults.
THIS APPLIANCE MUST BE EARTHED.
Procedures of Wiring
Wiring Of The Outdoor Unit
Please remove the side cover for wire connection.
Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not reach the specified capacity.
Wiring Of The Indoor Unit
Procedures of Removing the Wire Connection Cover Pull the hooks at positions 1 and 2 of the s-cover of the air outlet on the right bottom of front cover in the directions as shown by
arrows to remove the s-cover.
Procedures of Wiring Open the front panel, loosen and remove the screw at the electric box cover located at the right side of front cover. Loosen and remove the screw fixing inner cover (sheet metal). After inserting the connecting cords from the s-cover of air outlet, bend the tips of connecting cords as shown in the figure below. Fix the cords securely to the inner cover (sheet metal) according to their respective colors. (Tightening torque: 5kgf·cm). After the wiring is done, reinstall the inner cover (sheet metal) and the electric box cover accordingly.
CAUITON
WARNING
WARNING
CAUITON
WARNING
CAUTION
CONDENSED WATER DISPOSAL OF OUTDOOR UNIT
RAC-ME10HZ
RAC-ME14HZ
RAC-ME10HZ
RAC-ME14HZ
5~10mm
FNL
D
1
2
Yellow/green lines grounding
Wire clamp for
power cord
Inner Cover (sheet metal)
S-cover
white black red
yellow
yelloweulbder
brown
Electric Box Cover
5
5
5
Loading...