Hitachi RAK-50PPA(T), RAC-50WPAT, RAK-60PPA(T), RAC-60WPA(T), RAC-25NPA(T) Instruction Manual

...
Page 1
– 1 –
ENGLISH
SPLIT TYPE AIR CONDITIONER
INDOOR UNIT/OUTDOOR UNIT
RAK-50PPA(T)
OUTDOOR UNIT
INDOOR UNIT
RAC-50WPA(T)
RAK-50PPA(T) / RAC-50WPA(T)
RAK-50PPA(T)-1 1RAK-50PPA(T)-1 1 3/14/14 12:32 PM3/14/14 12:32 PM
Page 2
– 2 –
SAFETY PRECAUTION
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of “
!
Warning” and “!Caution”. The “Warning” section contains matters which, if not
observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The sign indicate the following meanings.
Make sure to connect earth line.
The sign in the fi gure indicates prohibition.
Indicates the instructions that must be followed.
Please keep this manual after reading.
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air ow for your health.
W
A R N
I
N
G
!
Do not insert a fi nger, a rod or other objects into the air outlet or inlet. As the fan is rotating
at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn the breaker OFF.
Do not use any conductor as fuse wire, this could cause fatal accident.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
Should abnormal situation arises (like burning smell), please stop operating the unit and turn
off the circuit breaker. Contact your agent. Fault, short circuit or fi re may occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric
shock and fi re.
Please contact your agent if you need to remove and reinstall the unit. Electric shock or fi re
may occur if you remove and reinstall the unit yourself improperly.
If the supply cord is damaged, it must be replaced by the special cord obtainable at
authorized service/parts centers.
W
A R N
I
N
G
!
During thunder storm, disconnect and turn off the circuit breaker.
WARNING
PRECAUTIONS DURING INSTALLATION
Do not reconstruct the unit.
Water leakage, fault, short circuit or fi re may occur if you reconstruct the unit by yourself.
Please ask your sales agent or qualifi ed technician for the installation of your unit. Water
leakage, short circuit or fi re may occur if you install the unit by yourself.
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth
line of telephone. Improper installation of earth line may cause electric shock.
Be sure to use the specifi ed piping set for R410A. Otherwise, this may result in broken
copper pipes or faults.
A circuit breaker should be installed depending on the mounting site of the unit. Without
a circuit breaker, the danger of electric shock exists.
Do not install near location where there is fl ammable gas. The outdoor unit may catch
re if fl ammable gas leaks around it.
Please ensure smooth ow of water when installing the drain hose.
Do not install the indoor unit in a machine shop or kitchen where vapor from oil or its
mist fl ows to the indoor unit. The oil will deposit on the heat exchanger, thereby reducing the indoor unit performance and may deform and in the worst case, break the plastic parts of the indoor unit.
CAUTION
!
!
Spray cans and other combustibles should not be located within a meter of the air outlets
of both indoor and outdoor units.
As a spray can’s internal pressure can be increased by hot air, a rupture may result.
RAK-50PPA(T)-1 2RAK-50PPA(T)-1 2 3/14/14 12:32 PM3/14/14 12:32 PM
Page 3
– 3 –
ENGLISH
PRECAUTIONS DURING OPERATION
Do not attempt to operate the unit with wet hands, this could cause fatal
accident.
When operating the unit with burning equipments, regularly ventilate the
room to avoid oxygen insuffi ciency.
Do not direct the cool air coming out from the air-conditioner panel to face
household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
Do not use any aerosol or hair sprays near the indoor unit. This chemical
can adhere on heat exchanger fi n and blocked the evaporation water fl ow to drain pan. The water will drop on tangential fan and cause water splashing
out from indoor unit.
Please ensure that outdoor mounting frame is always stable, fi rm and
without defect. If not, the outdoor unit may collapse and cause danger.
Do not splash or direct water to the body of the unit when cleaning it as
this may cause short circuit.
When operating the unit with the door and windows opened, (the room humidity is always above
80%) and with the air defl ector facing down or moving automatically for a long period of time, water will condense on the air defl ector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
If the amount of heat in the room is above the cooling or heating capability of the unit (for
example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
This appliance is not intended for use by young children or infi rm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
Do not climb on the outdoor unit or put objects on it.
Please switch off the unit and turn off the circuit breaker during cleaning,
the high-speed fan inside the unit may cause danger.
Turn off the circuit breaker if the unit is not to be operated for a long period.
C A U T
I O N
The product shall be operated under the manufacturer specifi cation and
not for any other intended use.
Do not put water container (like vase) on the indoor unit to avoid water
dripping into the unit. Dripping water will damage the insulator inside the unit and causes short-circuit.
Do not place plants directly under the air fl ow as it is bad for the plants.
!
RAK-50PPA(T)-1 3RAK-50PPA(T)-1 3 3/14/14 12:32 PM3/14/14 12:32 PM
Page 4
– 4 –
INDOOR UNIT
NAMES AND FUNCTIONS OF EACH PART
Pre-fi lter
To prevent dust from coming into the indoor unit. (Refer page 35)
Front panel
Indoor unit indicators
Light indicator showing the operating condition. (Refer page 5)
Horizontal defl ector
Vertical defl ector
(Air Outlet)
Remote controller
Send out operation signal to the indoor unit. So as to operate the whole unit. (Refer Remote control manual)
MODEL NAME AND DIMENSIONS
OUTDOOR UNIT
DRAIN PIPE
Condensed water drain to outside.
CONNECTING CORD
AIR INLET (BACK, LEFT SIDE)
AIR OUTLET
Air purifying fi lters are not washable. It is recommended to use vacuum to clean it. It can be use
for 1 year time. Type number for this air purifying fi lter is <SPX-CFH22>. Please use this number for ordering when you want to replace it.
NOTE
MODEL WIDTH (mm) HEIGHT (mm)
DEPTH (mm)
RAK-50PPA(T) 790 300
230
RAC-50WPA(T) 850 650
298
RAK-50PPA(T)-1 4RAK-50PPA(T)-1 4 3/14/14 12:32 PM3/14/14 12:32 PM
Page 5
– 5 –
ENGLISH
INDOOR UNIT INDICATORS
OPERATION INDICATOR
FILTER LAMP
When the device is operated for a total of about 200 hours, the FILTER lamp lights to indicate that it is time to clean the fi lter. The lamp goes out when the “ (AUTO SWING)” button is pressed while the device is on “STANDBY MODE”.
OPERATION LAMP
This lamp lights during operation. The OPERATION LAMP fl ashes in the following cases during heating.
(1) During preheating
For about 2–3 minutes after starting up.
(2) During defrosting
Defrosting will be performed about once every one
hour when frost forms on the heat exchanger of the outdoor unit, for 5–10 minutes each time.
TIMER LAMP
This lamp lights when the timer is working.
TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work.
By pressing the temporary switch, the operation is done in automatic mode.
When the operation is done using the temporary switch after the power source is turned off and turn
on again, the operation is done in automatic mode.
RAK-50PPA(T)-1 5RAK-50PPA(T)-1 5 3/14/14 12:32 PM3/14/14 12:32 PM
Page 6
– 6 –
PREPARATION BEFORE OPERATION
To install the batteries
To x the remote controller holder to the wall
1. Slide the cover to take it off.
2. Install two dry batteries AAA.LR03 (alkaline). The direction of the batteries should match the
marks in the case.
3. Replace the cover at its original position.
1. Choose a place from where the signals can reach the unit.
2. Fix the remote controller holder to a wall, a pillar or similar location with the provided screws.
3. Place the remote controller in the remote controller holder.
NOTE
Notes on batteries
When replacing the batteries, use batteries of the same
type, and replace both old batteries together.
When the system is not used for a long time, take the
batteries out.
The batteries will last for approximately 1 year. However, if
the remote controller display begins to fade and degradation of reception performance occurs within a year, replace both batteries with new size AAA.LR03 (alkaline).
The attached batteries are provided for the initial use of
the system.
The usable period of the batteries may be short depending
on the manufactured date of the air conditioner.
Notes on the remote controller
Never expose the remote controller to direct sunlight.
Dust on the signal transmitter or receiver will reduce the
sensitivity. Wipe off dust with soft cloth.
Signal communication may be disabled if an electronic-
starter-type fl uorescent lamp (such as inverter-type lamps) is in the room. Consult the shop if that is the case.
If the remote controller signals happen to operate another
appliance, move that appliance to somewhere else, or consult the service shop.
When the remote controller is not in use, please close the
slide cover to prevent failure.
Remote controller
Screws
Remote
controller holder
RAK-50PPA(T)-2 6RAK-50PPA(T)-2 6 3/14/14 12:32 PM3/14/14 12:32 PM
Page 7
– 7 –
PREPARATION BEFORE OPERATION
To set calendar and clock
1. Press (RESET) button when fi rst time setting.
"Year" blinks.
2. Press
(TIME) button to set the current year.
3. Press
(CLOCK) button. "Day" and "Month"
blink.
4. Press
(TIME) button to set the current day and
month.
5. Press
(CLOCK) button. "CLOCK" blinks.
6. Press
(TIME) button to set the clock to the current
time.
7. Press
(CLOCK) button.
Calendar and clock are set.
To modify the calendar and clock, press
(CLOCK) button. Then follow steps 1 to 7.
Calendar and clock need to be set again after changing batteries.
After changing the batteries,
1. Press (RESET) button.
2. Direct remote controller towards indoor unit and press
(INFO) button.
3. The calendar and clock from indoor unit will be transmitted.
Calendar and clock will not be transmitted from indoor
unit when the following occurs:
When there is a power failure.
When breaker is OFF by user (unit is not in STANDBY
MODE).
NOTE
Note on setting the calendar and clock.
If the calendar and clock are not set, the ON-timer, OFF-timer and Weekly Timer cannot be set.
If the calendar and clock are not set correctly, the ON-timer, OFF-timer and Weekly Timer will not
operate correctly.
When the ON-timer, OFF-timer and Weekly Timer are set, the calendar and clock cannot be changed.
If there is a need to change the calendar and clock, ON-timer, OFF-timer and Weekly Timer need to be cancelled.
RAK-50PPA(T)-2 7RAK-50PPA(T)-2 7 3/14/14 12:32 PM3/14/14 12:32 PM
Page 8
– 8 –
NAMES AND FUNCTIONS OF REMOTE CONTROLLER
REMOTE CONTROLLER
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is
controlled electronically, the range of control may be shorter.
This unit can be fi xed on a wall using the fi xture provided. Before fi xing it, make sure the indoor unit can
be controlled from the remote controller.
Handle the remote controller with care. Dropping it or getting it wet may compromise its signal transmission
capability.
After new batteries are inserted into the remote controller, the unit will initially require approximately 10
seconds to respond to commands and operate.
When remote controller is not in use for about 3 minutes during OFF condition, indicated by on the
display, the LCD will turn off.
During clock setting, the LCD will turn off about 10 minutes later if the remote controller is not in use.
When pressing any button, the LCD will turn on.
The LCD will not turn off during TIMER setting.
Signal Transmitting/Receiving Window
Point this window towards the indoor unit when controlling it.
Sensor
A temperature sensor inside the remote controller senses ambient temperature around the remote­controller.
Display
This indicates the room temperature selected, current time, timer status, function and airfl ow rate selected.
ROOM TEMPERATURE setting Buttons
Press these buttons to set the room temperature.
Press the [ ] button to raise the room temperature.
Press the [
] button to lower the room
temperature.
Keep pressing and the value will change more quickly.
ECO Button
Use this button to set the ECO mode. (
p. 17)
START/STOP button
Press this button to start operation. Press it again to stop operation.
FAN SPEED selector Button
This determines the fan speed.
Every time you press this button,
the airfl ow rate will change from
(AUTO) (HIGH)
(MED) (LOW)
(SILENT) (This button allows
selection of optimal or preferred fan
speed for each operation mode).
Transmission sign
The transmission sign lights up when a signal is sent.
RAK-50PPA(T)-2 8RAK-50PPA(T)-2 8 3/14/14 12:32 PM3/14/14 12:32 PM
Page 9
– 9 –
MODE SELECTOR AUTO HEAT DEHUMIDIFY COOL FAN
FAN SPEED AUTO SILENT LOW MED HIGH
START / STOP
ECO
Precautions for Use
Do not put the remote controller in the following places.
Under direct sunlight.
● In the vicinity of a heater.
Handle the remote controller carefully. Do not drop it on the fl oor, and protect it from water.
Once the outdoor unit stops, it will not restart for about 3 minutes (unless you turn the power switch
off and on or unplug the power cord and plug it in again).
This is to protect the device and does not indicate a failure.
If you press the MODE selector button during operation, the device may stop for about 3 minutes for
protection.
POWERFUL Button
Use this button to set the POWERFUL mode. ( p. 15)
INFORMATION Button
(
p. 29)
ONE TOUCH CLEAN Button
(
p. 19)
ON / OFF TIMER setting Buttons
(
p. 20)
MODE selector Button
Use this button to select the operating mode. Every time you press this button, the mode will change from
(AUTO)
(HEAT)
(DEHUMIDIFY) (COOL) and (FAN) cyclically.
SILENT Button
Use this button to set the SILENT mode. ( p. 16)
AUTO SWING (Vertical) Button
Controls the angle of the horizontal air defl ector. (
p. 14)
AUTO SWING (Horizontal) Button
Controls the angle of the vertical air defl ector. (
p. 14)
WEEKLY TIMER setting Buttons
(
p. 23)
LEAVE HOME Button
( p. 18)
NAMES AND FUNCTIONS OF REMOTE CONTROLLER
ECO SLEEP TIMER Button
Use this button to set the ECO sleep timer. (
p. 21)
FAN
POWERFUL
SILENT
INFO
SLEEP TIMER
AUTO SWING (VERTICAL)
AUTO SWING (HORIZONTAL)
LEAVE HOME
CLEAN
DAY
PROGRAM NO.
ON / OFF TIMER
TIME
OK
DELETE
COPY / PASTE
CANCEL
SEND
CLOCK
RAK-50PPA(T)-2 9RAK-50PPA(T)-2 9 3/14/14 12:32 PM3/14/14 12:32 PM
Page 10
– 10 –
AUTOMATIC OPERATION
The device will automatically determine the mode of operation, HEAT or COOL depending on the current room temperature. The selected mode of operation will change when the room temperature varies. However, the mode of operation will not change when indoor unit is connected to multi type outdoor unit.
VARIOUS FUNCTIONS
Auto Restart Control
If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation
mode and airfl ow direction.
(As the operation is not stopped by remote controller.)
If you intend not to continue the operation when the power is resumed, switch off the power supply.
When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode
and airfl ow direction.
Note: 1. If you do not require Auto Restart Control, please consult your sales agent.
2. Auto Restart Control is not available when Timer or Sleep Timer mode is set.
As the settings are stored in the memory of the remote controller, you
only have to press the
(START/STOP) button next time.
Press the MODE selector button so that the display indicates the (AUTO) mode of operation.
When AUTO has been selected, the device will automatically determine the mode of operation, HEAT or COOL depending on the current room temperature. However the mode of operation will not change when indoor unit is connected to multi type outdoor unit.
If the mode automatically selected by the unit is not satisfactory, manually change the mode setting (HEAT, DEHUMIDIFY, COOL or FAN).
Press the (FAN SPEED) button to select AUTO, HIGH, MED, LOW or SILENT.
Press the
(START/STOP) button. Operation starts with a beep. Press the button again to stop operation.
Set the desired room temperature with the TEMPERATURE buttons (the display indicates the setting). The temperature setting and the actual room temperature may vary depending on conditions.
START
STOP
1
2
3
Set the desired FAN SPEED with the (FAN SPEED) button (the display indicates the setting).
(AUTO) (HIGH) (MED)
(SILENT) (LOW)
RAK-50PPA(T)-2 10RAK-50PPA(T)-2 10 3/14/14 12:32 PM3/14/14 12:32 PM
Page 11
– 11 –
HEATING OPERATION
Use the device for heating when the outdoor temperature is under 21°C.
When it is too warm (over 21°C), the heating function may not work in order to protect the device.
In order to maintain reliability of the device, please use this device when outdoor temperature is above
–15°C.
Press the MODE selector button so that the display indicates (HEAT).
Set the desired FAN SPEED with the (FAN SPEED) button (the display indicates the setting).
(AUTO) (HIGH) (MED)
(SILENT) (LOW)
Set the desired room temperature with the TEMPERATURE buttons (the display indicates the setting).
The temperature setting and the actual room temperature may vary depending on conditions.
Press the
(START/STOP) button. Heating operation starts with
a beep. Press the button again to stop operation.
As the settings are stored in the memory of the remote controller, you only have to press the
(START/STOP) button next time.
During AUTO fan, the fan speed automatically changes as below:
When the difference between room temperature and setting temperature
is large, fan starts to run at HI speed.
After room temperature reaches the preset temperature, fan speed
will be changed to lower speed to obtain optimum room temperature condition for natural healthy heating.
START
STOP
Defrosting will be performed about once an hour when frost forms on the heat exchange of the outdoor unit, for 5~10 minutes each time. During defrosting operation, the operation lamp blinks in a cycle of 3 seconds on and 0.5 second off. The maximum time for defrosting is 20 minutes. However, if the indoor unit is connected to multi type outdoor unit, the maximum time for defrosting is 15 minutes. (If the piping length used is longer than usual, frost is likely to form.)
1
2
3
Defrosting
RAK-50PPA(T)-2 11RAK-50PPA(T)-2 11 3/14/14 12:32 PM3/14/14 12:32 PM
Page 12
– 12 –
DEHUMIDIFYING OPERATION
Dehumidifying Function
When the room temperature is higher than the temperature setting: The device will dehumidify the room,
reducing the room temperature to the preset level.
When the room temperature is lower than the temperature setting: Dehumidifying will be performed at the
temperature setting slightly lower than the current room temperature, regardless of the temperature setting.
The preset room temperature may not be reached depending on the number of people present in the room
or other room conditions.
Set the desired room temperature with the ROOM TEMPERATURE setting buttons (the display indicates the setting).
The range of 20-26˚C is recommended as the room temperature for dehumidifying.
Press the (START/STOP) button. Dehumidifying operation starts with a beep. Press the button again to stop operation.
As the settings are stored in the memory of the remote controller, you only have to press the
(START/STOP) button next time.
START
STOP
Press the MODE selector button so that the display indicates
(DEHUMIDIFY). The fan speed is set at LOW. Press (FAN SPEED) button to select SILENT or LOW fan speed.
Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work.
1
2
RAK-50PPA(T)-2 12RAK-50PPA(T)-2 12 3/14/14 12:32 PM3/14/14 12:32 PM
Page 13
– 13 –
COOLING OPERATION
Use the device for cooling when the outdoor temperature is -10~ 43°C. If indoors humidity is very high (80%), some dew may form on the air outlet grille of the indoor unit.
Press the MODE selector button so that the display indicates (COOL).
As the settings are stored in the memory of the remote controller, you only have to press the
(START/STOP) button next time.
During AUTO fan, the fan speed automatically changes as below:
When the difference between room temperature and setting
temperature is large, fan starts to run at HI speed.
After room temperature reaches the preset temperature, fan speed
will be changed to lower speed to obtain optimum room temperature condition for natural healthy cooling.
START
STOP
1
2
3
Set the desired FAN SPEED with the (FAN SPEED) button (the display indicates the setting).
(AUTO) (HIGH) (MED)
(SILENT) (LOW)
Set the desired room temperature with the TEMPERATURE buttons (the display indicates the setting).
The temperature setting and the actual room temperature may vary depending on conditions.
Press the
(START/STOP) button. Cooling operation starts with a beep. Press the button again to stop operation. The cooling function does not start if the temperature setting is higher than the current room temperature (even though the (OPERATION) lamp lights). The cooling function will start as soon as user set the temperature below the current room temperature.
RAK-50PPA(T)-2 13RAK-50PPA(T)-2 13 3/14/14 12:32 PM3/14/14 12:32 PM
Page 14
– 14 –
FAN OPERATION
AUTO SWING OPERATION
User can use the device simply as an air circulator.
VERTICAL SWING
HORIZONTAL SWING
START
STOP
1
2
Press the MODE selector so that the display indicates (FAN).
Set the desired FAN SPEED with the (FAN SPEED) button (the display indicates the setting).
(HIGH) (MED) (LOW) (SILENT)
Press the (START/STOP) button. Fan operation starts with a beep. Press the button again to stop operation.
To start Vertical Auto Swing
To start Horizontal Auto Swing
To cancel Vertical Auto Swing
To cancel Horizontal Auto Swing
Press (AUTO SWING (VERTICAL)) button. The de ector(s) will start
to swing up and down.
is displayed on the LCD.
Press (AUTO SWING (HORIZONTAL)) button. The de ectors will
start to swing right and left.
is displayed on the LCD.
Press (AUTO SWING (VERTICAL)) button again. The de ector(s) will
stop in the current position.
disappeared from the LCD.
Press (AUTO SWING (HORIZONTAL)) button again. The de ectors
will stop in the current position.
disappeared from the LCD.
NOTE
During cooling and dehumidifying operation, do not keep the defl ectors swinging or in the lower position
(in the case of vertical auto swing) for a long time. It may cause dew condensation on the defl ectors.
RAK-50PPA(T)-2 14RAK-50PPA(T)-2 14 3/14/14 12:32 PM3/14/14 12:32 PM
Page 15
– 15 –
POWERFUL OPERATION
By pressing (POWERFUL) button during AUTO, HEATING, DEHUMIDIFYING, COOLING or FAN
operation, the air conditioner performs at the maximum power.
During POWERFUL operation, cooler or warmer air will be blown out from indoor unit for COOLING or
HEATING operation respectively.
To start POWERFUL operation
To cancel POWERFUL operation
Press (POWERFUL) button during operation.
” is displayed on the LCD.
POWERFUL operation ends in 20 minutes. Then the system
automatically operates with the previous settings used before POWERFUL operation.
Press the (START/STOP) button. Or
Press (POWERFUL) button again.
POWERFUL operation stops.
” disappears from the LCD.
1
NOTE
When SLEEP mode, ECO mode, SILENT mode or LEAVE HOME mode is selected, POWERFUL
operation is cancelled.
During POWERFUL operation, capacity of the air conditioner will not increase
– if the air conditioner is already running at maximum capacity. – just before defrost operation (when the air conditioner is running in HEATING operation).
After auto restart, POWERFUL operation is cancelled and previous operation shall start.
For multi model connections, POWERFUL operation may not function depending on operation conditions.
RAK-50PPA(T)-2 15RAK-50PPA(T)-2 15 3/14/14 12:32 PM3/14/14 12:32 PM
Page 16
– 16 –
SILENT OPERATION
By pressing (SILENT) button during AUTO, HEATING, DEHUMIDIFYING, COOLING or FAN
operation, the fan speed will change to ultra slow.
To start SILENT operation
To cancel SILENT operation
Press (SILENT) button during operation.
” is displayed on the LCD. Fan speed will be ultra slow.
Press (START/STOP) button. Or
Press (SILENT) button again or (FAN SPEED)
button.
Fan speed will return to previous fan speed before SILENT
operation starts.
SILENT operation stops.
” disappears from the LCD.
1
NOTE
When POWERFUL operation is selected, SILENT operation is cancelled. Fan speed will return to
previous fan speed before SILENT operation.
After auto restart, SILENT operation is cancelled. Fan speed will return to previous fan speed before
SILENT operation.
During any operation with fan speed (SILENT), if press (SILENT) button, fan speed will
not change.
RAK-50PPA(T)-2 16RAK-50PPA(T)-2 16 3/14/14 12:32 PM3/14/14 12:32 PM
Page 17
– 17 –
ECO OPERATION
ECO operation is an energy saving function by changing set temperature automatically and by limiting the maximum power consumption value.
By pressing the (ECO) button during AUTO, HEATING,
DEHUMIDIFYING or COOLING operation, the air conditioner
performs the "ECO" operation.
1
To start ECO operation
To cancel ECO operation
Press (ECO) button during operation.
” is displayed on the LCD.
Energy saving operation will start by changing the set temperature
higher or lower automatically and reducing operation power consumption. This function may vary based on the connected outdoor unit.
Press (START/STOP) button. Or
Press (ECO) button again.
” disappears from the LCD.
NOTE
ECO function will not be effective when power consumption is low.
By pressing (POWERFUL) button, ECO operation is cancelled.
After auto restart, ECO operation is cancelled and previous operation mode shall start.
For multi model connections, energy saving operation shall start only by changing set temperature higher
or lower automatically. However, effectiveness of ECO depends on operation conditions.
RAK-50PPA(T)-2 17RAK-50PPA(T)-2 17 3/14/14 12:32 PM3/14/14 12:32 PM
Page 18
– 18 –
LEAVE HOME(LH) OPERATION
Prevent the room temperature from falling too much by setting temperature 10°C automatically when no one is at home.
This operation is able to operate by "Continuous operation" or "Day timer operation". Please use "Day timer operation" to set the number of days up to 99 days.
To start LEAVE HOME operation
Option 1. Continuous operation.
Press (LEAVE HOME) button during stop or operation.
Room temperature is set at 10°C and heating operation starts.
”, “ ”, “ ”, “ ” is displayed on the LCD.
Option 2. Day timer operation.
Press (LEAVE HOME) button during stop or operation.
Room temperature is set at 10°C and heating operation starts.
“ ”, “ ”, “ ”, “ ” is displayed on the LCD.
Set number of operation days (1 to 99 days), if needed.
Press
(TIME) button to select number of days.
Number of days blink.
* Press “
(UP)” to set number of days from 1 day, 2 days, 3
days ..... 98 days, 99 days, 1 day and so on.
* Press “
(DOWN)” to set number of days from 99 days, 98
days, 97 days .... 3 days, 2 days, 1 day, 99 days and so on.
* Number of day is counted when clock indicates 0:00.
Press (SEND) button to confi rm number of operation
days. Display for number of operation days will stop blinking.
Press (CANCEL) button to reset number of operation
days or to have continuous operation.
1
To cancel LEAVE HOME operation
Press (START/STOP) button. Or
Press (LEAVE HOME) button again.
Return to previous operation mode. Or
Change to other operation mode by pressing (MODE) button.
NOTE
After reaching the set number of operation days for Leave Home or by pressing the (Leave Home) button again,
the unit will operate in previous mode.
During Leave Home operation, fan speed and horizontal air de ector position cannot be changed.
By pressing (Leave Home) button, implementation of Weekly Timer or Once Timer is cancelled.
In case of power supply shut down, after autorestart, all setting for number of days operation will be reset and unit
shall be in continuous operation.
For multi connections, when each room is running in different operation modes such as FAN only, COOLING,
DEHUMIDIFYING or AUTO mode, Leave Home operation cannot operate even though it is possible to set Leave Home operation.
In order to start Leave Home operation, all rooms must stop its operation. Then, press (LEAVE HOME) button to
operate Leave Home operation.
For multi connections, when all rooms are running HEATING operation, it is possible to operate Leave Home operation
by pressing the (LEAVE HOME) button.
For multi connections, if two or more rooms are set to operate Leave Home operation, the capability to reach the
set temperature at 10°C may not possible. In addition, this also depends on outdoor temperature.
POWERFUL, SILENT and ECO operations are not applicable during Leave Home operation.
Continuous operation
Day timer operation
RAK-50PPA(T)-2 18RAK-50PPA(T)-2 18 3/14/14 12:32 PM3/14/14 12:32 PM
Page 19
– 19 –
CLEAN (ONE TOUCH CLEAN) OPERATION
Drying indoor heat exchanger after cooling operation to prevent mildew.
To start CLEAN operation
To cancel CLEAN operation
Press (CLEAN) button when unit is OFF.
Total time taken for One Touch Clean operation is 60 minutes.
During this operation, HEATING or FAN operation shall operate.
During one touch clean, operation lamp is blinking.
”, “ ” is displayed on the LCD.
Press (START/STOP) button. Or
Press (CLEAN) button again.
1
NOTE
When CLEAN operation nish, unit will switch OFF automatically.
If Weekly Timer or Once Timer is set, there is a need to cancel those timer before operating CLEAN
function.
For multi connections, when pressing (CLEAN) button, operation is limited to FAN operation.
For multi connections, when one room operates CLEAN operation rst, other rooms can operate
COOLING, DEHUMIDIFYING or FAN operation. However, when other rooms need to operate HEATING operation, air conditioner will be in STANDBY mode. After CLEAN operation fi nish, HEATING operation will start.
RAK-50PPA(T)-2 19RAK-50PPA(T)-2 19 3/14/14 12:32 PM3/14/14 12:32 PM
Page 20
– 20 –
ONCE TIMER (ON/OFF TIMER) OPERATION
The device can be set to turn off at a preset time.
1. Press
(OFF-TIMER) button. and blink on the display.
2. Set the "turn-off time" with
(TIME) button.
3. After setting, direct the remote controller towards the indoor and press (SEND) button.
and "set time" lights up instead of blinking.
A beep sound emitted from indoor unit and the (TIMER) lamp on the
indoor unit lights up.
ON TIMER
The device will turn on at a designated time.
1. Press
(ON-TIMER) button. and blink on the display.
2. Set the "turn-on time" with
(TIME) button.
3. After setting, direct the remote controller towards the indoor and press (SEND) button.
and "set time" light up instead of blinking.
A beep sound emitted from indoor unit and the (TIMER) lamp on the indoor
unit lights up.
ON/OFF TIMER
The device will turn on (off) and off (on) at the designated time.
The switching occurs rst at the preset time that comes earlier.
The arrow mark appears on the display to indicate the sequence of switching
operations.
1. Press
(OFF-TIMER) button so that and blink on the
display.
2. Set the "turn-off" time with
(TIME) button. After setting, direct the remote
controller towards the indoor and press
(SEND) button.
3. Press
(ON-TIMER) button so that and set "turn-off" time light up.
The
and blink.
4. Set the "turn-on" time with
(TIME) button.
5. After setting, direct the remote controller towards the indoor and press
(SEND) button
and set "turn-on" time light up instead of blinking.
A beep sound emitted from indoor unit and the (TIMER) lamp on the indoor
unit lights up.
The timer may be used in three ways: OFF-timer, ON-timer and ON/OFF (OFF/
ON)-timer. Set the current time fi rst because it serves as a reference.
To cancel Reservation
Point the signal window of the remote controller towards the indoor unit and press (CANCEL) button.
and "ON or OFF set time" goes out with a beep and the (TIMER) lamp on the indoor unit turns off.
NOTE
User can set only one of the OFF-timer, ON-timer or ON/OFF-timer.
If WEEKLY TIMER already set, by setting the ONCE TIMER, ONCE TIMER operation is prioritized. When ONCE
TIMER operation is complete, WEEKLY TIMER operation will be activated.
OFF TIMER
1
RAK-50PPA(T)-2 20RAK-50PPA(T)-2 20 3/14/14 12:32 PM3/14/14 12:32 PM
Page 21
– 21 –
ECO SLEEP TIMER OPERATION
The timer can be set up to a duration of 7 hours.
By pressing
(SLEEP) button during AUTO, HEATING, DEHUMIDIFYING, COOLING or FAN operation,
the unit shifts the room temperature and reduces the fan speed. It results in energy saving. Set the current time fi rst before operating the ECO SLEEP TIMER operation.
To start ECO SLEEP TIMER operation
To cancel ECO SLEEP TIMER operation
Press (SLEEP) button during operation.
”, “ ”, “ ”, “OFF”, off time, “ ” and number
of hour are displayed on the remote controller display.
During ECO SLEEP TIMER operation, fan speed will be ultra
slow.
A beep sound emitted from indoor unit and the (TIMER) lamp
on the indoor unit lights up.
Pressing (SLEEP) button repeatedly, the number of hours
will change as below:
During ECO SLEEP TIMER operation, air conditioner will
continue to operate for the designated number of hours and then turn off.
When the ECO SLEEP TIMER has been set, the display on
the remote controller indicates the turn off time.
Press
(START/STOP) button.
Room air conditioner will switch off.
Press
(SLEEP) button again until “ ”, “ ”, “ ”,
off time, “
” and number of hour disappear from the remote
controller display.
Press
(CANCEL) button.
A beep sound emitted from indoor unit and the (TIMER) lamp
on the indoor unit turns off.
SLEEP TIMER operation is cancelled.
1
Example: If ECO SLEEP TIMER is set for 1 hour at 18:00, the switch off time will be at 19:00.
1 H 2 H 3 H 7 H
SLEEP TIMER off
RAK-50PPA(T)-2 21RAK-50PPA(T)-2 21 3/14/14 12:32 PM3/14/14 12:32 PM
Page 22
– 22 –
ECO SLEEP TIMER OPERATION
To set ECO SLEEP TIMER and ON TIMER
To cancel ECO SLEEP TIMER and ON TIMER operation
The air conditioner will be turned off by ECO SLEEP TIMER and turned on by ON TIMER.
1. Set the ON TIMER.
2. Press
(SLEEP) button and set ECO SLEEP TIMER.
Direct the remote controller towards the indoor unit and press
(CANCEL) button.
”, “ ”, “ ”, “OFF”, off time, “ ”, number of hour, "ON" and ON TIMER set time disappear
from the remote controller display.
A beep sound emitted from indoor unit and the (TIMER) lamp on the indoor unit turns off.
ECO SLEEP TIMER and ON TIMER reservations are cancelled.
30 minutes after setting ECO SLEEP TIMER, outdoor fan speed will be reduced to lower the noise level and to have comfort operation. 1 hour after setting ECO SLEEP TIMER, set temperature will be slightly shifted. Amount of temperature shifted depends on type of air conditioner. These automatic operation changes contribute to energy saving without losing comfort. The level of energy consumption depends on outside temperature, room temperature, set temperature or air conditioner type.
Cooling operation [diagram representation for illustrative purpose only]
Example: In this case, air conditioner will turn off in 2 hours (at 1:38) and it will be turned on at 6:00 the next morning.
NOTE
If ECO SLEEP TIMER is set when OFF TIMER or ON/OFF TIMER has been set earlier, the ECO
SLEEP TIMER becomes effective instead of the OFF TIMER or ON/OFF TIMER.
Heating operation [diagram representation for illustrative purpose only]
Temperature
30 minutes
Outdoor fan
speed reduce
Shift
temperature
1 hour
Temperature
30 minutes
Outdoor fan
speed reduce
Shift
temperature
1 hour
RAK-50PPA(T)-2 22RAK-50PPA(T)-2 22 3/14/14 12:32 PM3/14/14 12:32 PM
Page 23
– 23 –
It is possible to select Mode A or Mode B. For each mode, up to 6 programs can be set per day. In total, a
maximum of 42 programs can be set for a week for each mode.
If calendar and clock are not set, the reservation setting for WEEKLY TIMER cannot be set.
If calendar and clock are not set correctly, WEEKLY TIMER will not operate correctly.
Reservation for calendar and clock shall be set rst before operating WEEKLY TIMER.
WEEKLY TIMER OPERATION
How to set a WEEKLY TIMER.
1. Select Mode A or Mode B
Press (WEEKLY) button. lights up. and blink on the
display. (Mode A is selected).
Press (WEEKLY) button again, and blink on the display.
(Mode B is selected).
If no reservation has been made, ON/OFF, , appear.
If reservation has been made, ON/OFF, , will not appear.
2. Set a program
Press (WEEKLY) button for about 3 seconds. The selection mode
can be changed.
, day: Mon, program no. : 1, ON/OFF, setting time and setting
temperature blink on the display.
3. Select the desired day of the week
Press (DAY) button.
The day changes from Mon
Tue Wed Thu Fri Sat Sun
Mon, Tue, Wed, Thu, Fri, Sat, Sun [Full days] Mon, Tue, Wed, Thu,
Fri [weekday] Sat, Sun [weekend] Mon Tue ......
Select [Full days] for daily reservation. Select [weekday] for Monday to Friday reservation. Select [weekend] for Saturday and Sunday reservation.
After reservation has been set, it is easy to check and edit at the same
time.
4. Press
button to select a program number.
The number changes from 1
2 3 4 5 6 1 2 .....
If program number has been set, follow above in order to make
changes.
1
2
Step 1 : Set the reservation schedule to the remote controller. Send the registered reservation to indoor
unit and then operate. Step 2 : Select Mode A or Mode B and activate or deactivate WEEKLY TIMER . Step 3 : Copy and cancel the reservation schedule.
Step 1 : Set reservation schedule to the remote controller. Send the registered
reservation to indoor unit and then operate.
3
4
RAK-50PPA(T)-2 23RAK-50PPA(T)-2 23 3/14/14 12:32 PM3/14/14 12:32 PM
Page 24
– 24 –
5. Press
(ON-OFF TIMER) button to select ON TIMER or OFF TIMER
reservation.
6. Press
(TIME) button to set time reservation.
7. Press (TEMP or ) button to set temperature reservation.
8. Press (OK) button. The reservations are set. Day, program number, ON reservation, setting temperature will light up. will be continuously blinks. If reservation is not complete, settings will not be stored in memory.
To continue with the reservation, press buttons. Follow step 3 to 8 for reservation.
9. After all the reservations have been set, press (SEND) button while directing the remote controller towards the indoor unit for about 3 seconds. Timer lamp on the indoor unit will blink rapidly.
After beep sound emitted from indoor unit, TIMER lamp will light up.
Please ensure that the TIMER lamp lights up.
This indicates that the reservation has been stored in the indoor unit and
Timer function has been completed.
The reservation contents will appear on the remote controller display.
If TIMER lamp on the indoor unit does not light up, press (SEND)
button while directing the remote controller towards the indoor unit for about 3 seconds.
CAUTION ! Do not press (CANCEL) button during reservation
setting because this will result in all reservation contents to be lost.
The reservation contents will not stored in the indoor unit until
(SEND) button has been pressed.
5
6
7
8
9
NOTE
Up to 6 programs can be set per day. Setting ON TIMER or OFF TIMER for each program number
can be at random. When pressing (SEND) button, the set ON TIMER or OFF TIMER for each program number will automatically arranged so that program number 1 shall have the earliest time and program number 6 shall have the latest time.
If the setting time is the same, Priority will be given to the latest reservation contents.
CAUTION ! If the remote controller is left idle and (SEND) button is not pressed within 3 minutes
after reservations have been made , all current reservations will be lost.
WEEKLY TIMER OPERATION
RAK-50PPA(T)-2 24RAK-50PPA(T)-2 24 3/14/14 12:32 PM3/14/14 12:32 PM
Page 25
– 25 –
How to select Mode A or Mode B of WEEKLY TIMER setting.
1. Press
(WEEKLY) button. and blink on the display.
(Normally Mode A will blink fi rst).
2. Press (WEEKLY) button again. and blink on the display.
3. Select Mode A or Mode B. Press (SEND) button while directing the remote controller towards the indoor unit for about 3 seconds. Timer lamp on the indoor unit will blink rapidly.
After beep sound emitted from indoor unit, TIMER lamp will light up.
Please ensure that the TIMER lamp lights up.
This indicates that Mode A or Mode B selection and active WEEKLY
TIMER have been confi rmed.
Setting non-active WEEKLY TIMER .
1. Direct the remote controller towards the indoor unit and press (CANCEL) button.
Beep sound will be emitted from indoor unit and TIMER lamp will be OFF.
Reservation indication on remote display will also disappear.
This indicates that non-active WEEKLY TIMER has been confi rmed.
To activate back the setting of WEEKLY TIMER , repeat the steps for
"How to select Mode A or Mode B of WEEKLY TIMER setting".
NOTE
When setting ONCE TIMER, operation of WEEKLY TIMER is interrupted. After ONCE TIMER operation
is complete, WEEKLY TIMER operation will be activated.
When ONCE TIMER is cancelled, operation of WEEKLY TIMER is also cancelled. Need to set WEEKLY
TIMER operation for activation.
After auto restart, WEEKLY TIMER operation is cancelled. Need to set WEEKLY TIMER operation for
activation.
1
2
1
WEEKLY TIMER OPERATION
Step 2: Select Mode A or Mode B and activate or deactivate WEEKLY TIMER.
3
RAK-50PPA(T)-2 25RAK-50PPA(T)-2 25 3/14/14 12:32 PM3/14/14 12:32 PM
Page 26
– 26 –
How to copy and paste.
Editing the reservation schedule is easy by copying data from one day to another day.
1. Press
(WEEKLY) button to select Mode A or Mode B.
2. Press (WEEKLY) button for about 3 seconds to start editing the reservation schedule.
3. Press (DAY) button to select a day of the week to copy.
4. Press (COPY/PASTE) button. Then "PASTE" blinks on the display.
* Press
(CANCEL) button to cancel the COPY mode. Normal
setting mode is activated.
5. Press
(DAY) button to select a day of the week to paste.
6. Press (COPY/PASTE) button one more time to paste. only blinks on the display.
7. To continue copying to other days, press or or or
.
Then start from step 3.
8. After copy and paste completed, press (SEND) button while directing the remote controller towards the indoor unit for about 3 seconds. Timer lamp on the indoor unit will blink rapidly.
After beep sound emitted from indoor unit, TIMER lamp will light up.
Please ensure that the TIMER lamp lights up.
If TIMER lamp does not light up, Press
(SEND) button again.
Reservation data will not change if (SEND) button is not pressed.
Step 3: Copy and cancel the reservation schedule.
NOTE
If there is no reservation data, copying data from one day to another day cannot be done.
1
2
3
4
5
6
8
WEEKLY TIMER OPERATION
RAK-50PPA(T)-2 26RAK-50PPA(T)-2 26 3/14/14 12:32 PM3/14/14 12:32 PM
Page 27
– 27 –
Step 3: Copy and cancel the reservation schedule.
How to delete WEEKLY TIMER data.
[Delete one program number reservation]
1. Press (WEEKLY) button to select Mode A or Mode B.
2. Press (WEEKLY) button for 3 seconds to start editing the reserva-
tion schedule.
3. Press
(DAY) button to select a day of the week to edit.
4. Press
to select program number. Selected program number will
blink.
5. Press (DELETE) button. Reservation of selected program number
is deleted.
6. After deleting, press (SEND) button while directing the remote controller towards the indoor unit for about 3 seconds. Timer lamp on the indoor unit will blink rapidly.
After beep sound emitted from indoor unit, TIMER lamp will light up.
Please ensure that the TIMER lamp lights up.
Reservation will not change if (SEND) button is not pressed.
1
2
3
4
5
6
WEEKLY TIMER OPERATION
RAK-50PPA(T)-2 27RAK-50PPA(T)-2 27 3/14/14 12:32 PM3/14/14 12:32 PM
Page 28
– 28 –
Step 3: Copy and cancel the reservation schedule.
[Delete one day reservation]
1. Press (WEEKLY) button to select Mode A or Mode B.
2. Press (WEEKLY) button for 3 seconds to start editing the
reservation schedule.
3. Press (DAY) button to select a day of the week to edit.
4. Press
(DELETE) button for about 10 seconds. Reservations for all
program numbers will be deleted.
If press for a short time, reservation for one program number will be
deleted.
5. After deleting, press
(SEND) button while directing the remote controller towards the indoor unit for about 3 seconds. Timer lamp on the indoor unit will blink rapidly.
After beep sound emitted from indoor unit, TIMER lamp will light up.
Please ensure that the TIMER lamp lights up.
Reservation will not change if (SEND) button is not pressed.
1
1
2
NOTE
If all reservations in the remote controller were deleted and pressed (SEND) button, no signal will
be transmitted to indoor unit. TIMER lamp will remain off and no changes will be done to the reservations stored in the indoor unit.
3
2
4
5
WEEKLY TIMER OPERATION
[Delete Mode A or Mode B]
1. Press (WEEKLY) button to select Mode A or Mode B.
2. Direct the remote controller towards the indoor unit and press (DELETE) button for about 10 seconds while Mode A or Mode B display blinks.
After beep sound emitted from indoor unit, reservations for Mode A or
Mode B will disappear.
RAK-50PPA(T)-2 28RAK-50PPA(T)-2 28 3/14/14 12:32 PM3/14/14 12:32 PM
Page 29
– 29 –
INFO FUNCTION
By pressing (INFO) button, temperature around remote controller and monthly power consumption will
be displayed on the remote controller.
After changing the batteries, direct the remote controller towards the indoor unit and press (INFO) button.
Current calendar and clock will be transmitted from indoor unit.
In order to receive information from indoor unit, the distance between remote controller and receiver of indoor
units is within 2 meters.
To check temperature around remote controller
Current calendar and clock can be retrieved from indoor unit
To check monthly power consumption
Press (INFO) button.
Temperature will be displayed for 10 seconds.
Direct the remote controller towards the receiver of indoor unit (within 2 meters in front of indoor unit) and press
(INFO) button. Wait for 2
seconds for signal transmission.
Once received the current calendar and clock, check whether they are correct or not by pressing
(CLOCK) button.
If there is no power supply to indoor unit or calendar and clock have not
been set, INFO function cannot be used for sending or receiving information.
Direct the remote controller towards the receiver of indoor unit (within 2 meters in front of indoor unit) and press
(INFO) button. Wait for 2
seconds for signal transmission.
While temperature around remote controller is displayed, press (INFO) button repeatedly. The display will show as below:
this month power consumption amount for heating
last month power consumption amount for heating this month power consumption amount for cooling last month power consumption amount for cooling temperature around remote controller this month power consumption
amount for heating ...... cyclically.
If indication is not given, bring remote controller closer to the receiver of
the indoor unit.
Indicated value shall be regarded as a guide only.
1
NOTE
In case failure occurs to the air conditioner, by pressing (INFO) button, an error code will be displayed.
Direct the remote controller towards the receiver of indoor unit (within 2 meters in front of indoor unit) and
press (INFO) button. Wait for 2 seconds for signal transmission.
An error code will be displayed. Call service center and inform the error code.
Information of “Monthly power consumption” are not available for model RAM-130NP6A.
Info Function to check monthly power consumption.
During installation, in case of power failure or breaker ON / OFF, ensure to set the clock and calendar for
each indoor unit (unit in standby mode or auto restart), for single or multi connection, by pressing (START / STOP) button.
Failure to do the above, monthly power consumption amount will not be displayed on the remote controller.
RAK-50PPA(T)-2 29RAK-50PPA(T)-2 29 3/14/14 12:32 PM3/14/14 12:32 PM
Page 30
– 30 –
OPERATION MODE LOCK
The remote controller can be set to fi x the HEATING mode (including FAN), COOLING mode (including FAN) and DEHUMIDIFYING mode (including FAN) operations.
Method to lock HEATING mode (including FAN) operation.
Press (ECO) and (POWERFUL) buttons simultaneously for about 5 seconds when the remote controller is OFF.
”, “ ” and “ ” will be displayed for about 10 seconds. Later, “ ” and
” will remain.
This indicates that HEATING mode operation is locked.
When pressing
(MODE) button, “ ” or “ ” will be displayed.
Method to unlock HEATING mode (including FAN) operation.
Press
(ECO) and (POWERFUL) buttons simultaneously for about 5
seconds when the remote controller is OFF. All operation mode symbols will appear on the display for about 10 seconds. After that, operation mode symbol before cancellation will be displayed. This indicates that HEATING mode operation is unlocked.
Method to lock COOLING and DEHUMIDIFYING modes (including FAN) operations.
Press
(ECO) and (SILENT) buttons simultaneously for about 5 seconds
when the remote controller is OFF.
“ ”, “ ”, “ ” and “ ” will be displayed for about 10 seconds. Later, “ ” and “ ” will remain.
This indicates that COOLING and DEHUMIDIFYING mode operation is locked.
When pressing (MODE) button, “ ”, “ ” or “ ” will be displayed.
Method to unlock COOLING and DEHUMIDIFYING modes (including FAN) operations.
Press
(ECO) and (SILENT) buttons simultaneously for about 5 seconds
when the remote controller is OFF. All operation mode symbols will appear on the display for about 10 seconds. After that, operation mode symbol before cancellation will be displayed. This indicates that COOLING and DEHUMIDIFYING modes operation is unlocked.
NOTE
Operation Mode Lock function will not activate if TIMER reservations activate.
TIMER reservations shall be deactivated fi rst. Then, Operation Mode Lock function can be activated.
HEATING, COOLING and DEHUMIDIFYING mode (including FAN) operations can be unlocked by pressing
the (RESET) button. However, by pressing the (RESET) button, all the information stored in the remote controller will disappear. You may need to set the necessary information again.
For multi connections, unit and mode which is set to lock HEATING and switched on fi rst shall have
higher priority. Other units which are chosen to operate at different modes shall be in STANDBY until either the fi rst unit operation is switched off or the mode is selected to be same as the fi rst unit.
RAK-50PPA(T)-2 30RAK-50PPA(T)-2 30 3/14/14 12:33 PM3/14/14 12:33 PM
Page 31
– 31 –
ENGLISH
Note
The recommended temperature range for safety testing should be as below:
Cooling Heating
Minimum Maximum Minimum Maximum
Indoor
Dry bulb °C 21 32 20 27
Wet bulb °C 15 23 12 19
Outdoor
Dry bulb °C 21 43 2 21
Wet bulb °C 15 26 1 15
CIRCUIT BREAKER
When you do not use the room air conditioner, set the circuit breaker to “OFF”.
RAK-50PPA(T)-3 31RAK-50PPA(T)-3 31 3/14/14 12:38 PM3/14/14 12:38 PM
Page 32
– 32 –
Suitable Room Temperature Install curtain or blinds
Ventilation Effective Usage Of Timer
Do Not Forget To Clean The Pre-fi lter
Please Adjust Suitable Temperature
For Baby And Children
!
Warning
Freezing temperature is bad for health and a waste of electric power.
It is possible to reduce heat entering the room through windows.
At night, please use the “OFF or ON timer operation mode”, together with your wake up time in the morning. This will enable you to enjoy a comfortable room temperature. Please use the timer effectively.
Dusty pre-fi lter will reduce the air volume and the cooling effi ciency. To prevent from wasting electric energy, please clean the lter every 2 weeks.
Please pay attention to the room temperature and air fl ow direction when operating the unit for baby, children and old folks who have diffi culty in movement.
!
Caution
Do not close the room for a long period of time. Occasionally open the door and windows to allow the entrance of fresh air.
THE IDEAL WAYS OF OPERATION
RAK-50PPA(T)-3 32RAK-50PPA(T)-3 32 3/14/14 12:38 PM3/14/14 12:38 PM
Page 33
– 33 –
ENGLISH
FOR USER’S INFORMATION
The Air Conditioner And The Heat Source In The Room
Not Operating For A Long Time
When Lightning Occurs
!
Caution
If the amount of heat in the room is above the cooling capability of the air conditioner (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
When the indoor unit is not to be used for a long period of time, please switch off the power from the mains. If the power from mains remains “ON”, the indoor unit still consumes about 12W in the operation control circuit even if it is in “OFF” mode.
Warning
To protect the whole unit during lightning, please stop operating the unit and remove the plug from the socket.
Interference From Electrical Products
Caution
To avoid noise interference, please place the indoor unit and its remote controller at least 1m away from electrical products.
Inverter-type uorescent lamp.
To prevent interference, place at least 1m away.
!
!
OFF
RAK-50PPA(T)-3 33RAK-50PPA(T)-3 33 3/14/14 12:38 PM3/14/14 12:38 PM
Page 34
– 34 –
ATTACHING THE AIR PURIFYING FILTERS
1
Open the front panel
Pull up the front panel by holding it at both sides with
both hands.
2
Remove the Pre-fi lter
Push upward to release the claws and pull out the
Pre-fi lter.
3
Attaching the air purifying fi lters
Attach the air purifying fi lters to the frame by gently
compress its both sides and release after insertion into Pre-fi lter frame.
4
Attach the Pre-fi lters
Attach the Pre-fi lters by ensuring that the surface
written “FRONT” is facing front.
After attaching the Pre-fi lters, push the front panel at
three arrow portions as shown in fi gure and close it.
Cleaning and maintenance must be carried out when fi lter lamp lights. Before cleaning, stop operation and switch off the power supply.
CAUTION
!
!
CAUTION
Do not bend the air purifying lter as it may cause damage to the structure.
Please do not smell direct from source of fi lter.
NOTE
In case of removing the air purifying lters, please follow the above procedures.
The cooling capacity is slightly weakened and the cooling speed becomes slower when the air purifying
lters are used. So, set the fan speed to "HIGH" when using it in this condition.
Air purifying fi lters are not washable. It is recommended to use vacuum to clean it. It can be use for 1
year time. Type number for this air purifying fi lter is <SPX-CFH22>. Please use this number for ordering when you want to renew it.
Do not operate the air conditioner without Pre-fi lter. Dust may enter the air conditioner and fault may
occur.
RAK-50PPA(T)-3 34RAK-50PPA(T)-3 34 3/14/14 12:38 PM3/14/14 12:38 PM
Page 35
– 35 –
ENGLISH
MAINTENANCE
Cleaning and maintenance must be carried out when fi lter lamp lights. Before cleaning, stop operation and switch off the power supply.
1. PRE-FILTER
Clean the Pre-fi lter, as it removes dust inside the room. In case the Pre-fi lter is full of dust, the air fl ow will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to clean the Pre-fi lter following the procedure below.
!
CAUTION
1
Open the front panel and remove the Pre-fi lter
Gently lift and remove the air purifying fi lters
from the air purifying fi lter frame.
2
Vacuum dust from the Pre- lter and air purifying lter using vacuum cleaner. If there is too much
dust, rinse under running tap water and gently brush it with soft bristle brush. Allow fi lters to dry in shade.
3
Re-insert the air purifying fi lter to the fi lter frame.
Set the Pre-fi lter with “FRONT” mark facing front, and slot them into the original state.
After attaching the Pre-fi lters, push the front
panel at three arrow portions as shown in gure and close it.
!
CAUTION
Do not wash with hot water at more than 40°C. The pre- lter may shrink.
When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to the
sun. The pre-fi lter may shrink.
PROCEDURE
RAK-50PPA(T)-3 35RAK-50PPA(T)-3 35 3/14/14 12:38 PM3/14/14 12:38 PM
Page 36
– 36 –
2. Washable Front Panel
Remove the front panel and wash with clean water.
Wash it with a soft sponge. After using neutral detergent, wash thoroughly with clean water.
When front panel is not removed, wipe it with a soft
dry cloth. Wipe the remote controller thoroughly with a soft dry cloth.
Wipe the water thoroughly.
If water remains at indicators or signal receiver of indoor unit, it causes trouble.
Method of removing the front panel. Be sure to hold the front panel with both hands to detach and attach it.
!
CAUTION
Do not splash or direct water to the body of the unit when cleaning it as
this may cause short circuit.
Never use hot water (above 40°C), benzine, gasoline, acid, thinner or a
brush, because they will damage the plastic surface and the coating.
Removing the Front Panel
When the front panel is fully opened with both
hands, push the right arm to the outside to release it, and while closing the front panel slightly, pull it out forward.
Attaching the Front Panel
Move the projections of the left and right arms
into the Flanges in the unit and securely insert them into the holes.
Projection
Hole
Flange
RAK-50PPA(T)-3 36RAK-50PPA(T)-3 36 3/14/14 12:38 PM3/14/14 12:38 PM
Page 37
– 37 –
ENGLISH
1
2
3
REGULAR INSPECTION
PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONNEL EITHER
EVERY HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT OR SERVICE SHOP.
Is the earth line disconnected or broken?
Is the mounting frame seriously affected by rust and is the out­door unit tilted or unstable?
Is the plug of power line fi rmly plugged into the socket? (Please ensure no loose contact between them).
Cleaning and maintenance must be carried out only by qualifi ed service personnel. Before cleaning, stop operation and switch off the power supply.
!
CAUTION
3. MAINTENANCE BEFORE LONG OFF PERIOD
Run the unit by setting the operation mode to (COOL),
the temperature to 32°C and the fan speed to HI for about half a day on a fi ne day, and dry the whole of the unit.
Switch off the power plug.
Air
Blow
Confi rm
RAK-50PPA(T)-3 37RAK-50PPA(T)-3 37 3/14/14 12:38 PM3/14/14 12:38 PM
Page 38
– 38 –
AFTER SALE SERVICE AND WARRANTY
WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS.
When it does not operate
Is the fuse all right?
Is the voltage extremely high or low?
Is the circuit breaker “ON”?
Is the setting of operation mode different from other indoor units?
Is the pre- lter blocked with dust?
Does sunlight fall directly on the outdoor unit?
Is the air ow of the outdoor unit obstructed?
Are the doors or windows opened, or is there any source of heat
in the room?
Is the set temperature suitable?
Are the air inlets or air outlets of indoor and outdoor units
blocked?
Is the fan speed “LOW” or “SILENT”?
CONDITION CHECK THE FOLLOWING POINTS
Notes
In quiet operation or stopping the operation, the following phenomena may
occassionally occur, but they are not abnormal for the operation. (1) Slight fl owing noise of refrigerant in the refrigerating cycle. (2) Slight rubbing noise from the fan casing which is cooled and then
gradually warmed as operation stops.
The odor will possibly be emitted from the room air conditioner because the
various odor, emitted by smoke, foodstuffs, cosmetics and so on, sticks to it. So the pre-fi lter and the evaporator regularly must be cleaned to reduce the odor.
Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above
inspections. Inform your agent of the model of your unit, production number, date of installation. Please also inform him regarding the fault.
Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not reach the
specifi ed capacity.
When it does not cool well When it does not hot well
If the remote controller is not transmitting a signal.
Do the batteries need replacement?
Is the polarity of the inserted batteries correct?
Remote controller display is dim or blank.)
NOTE:
If the supply cord is damaged, it must be replaced by the special cord obtainable at authorized service
parts centers.
On switching on the equipment, particularly when the room light is dimmed, a slight brightness fl uctuation
may occur. This is of no consequence. The conditions of the local Power Supply Companies are to be observed.
RAK-50PPA(T)-3 38RAK-50PPA(T)-3 38 3/14/14 12:38 PM3/14/14 12:38 PM
Loading...