Hitachi RAS-10GH5, RAC-10GH5, RAS-14GH5, RAC-14GH5 Installation Manual

FOR SERVICE PERSONNEL ONLY
Indoor Unit / Outdoor Unit
SAFETY PRECAUTION
• Read the safety precautions carefully before operating the unit.
• The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING .......... Incorrect methods of installation may cause death or serious injury.
CAUTION .......... Improper installation may result in serious consequence.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper operation and maintenance of the unit as described in the user' s guide. Ask a customer to keep this installation manual together with the instruction manual.
WARNING
• Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the installation work yourself.
• Please observe the installation stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric shock and fire.
• Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and impose danger.
• Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical work. Use cables which are approved official in your country. Be sure to use the specified circuit. A short circuit and fire may occur due to the use of low quality wire or improper work.
• Be sure to use the specified cables for connecting the indoor and outdoor units. Please ensure that the connections are tight after the conductors of the wire are inserted into the terminals to prevent the external force is being applied to the connection section of the terminal base. Improper insertion and loose contact may cause over-heating and fire.
• Please use the specified components for installation work. Otherwise, the unit may collapse or water leakage, electric shock, fire or stronger vibration may occur.
• Be sure to use the specified piping set for R410A. Otherwise, this may result in broken copper pipes or faults.
• When installing or transferring an air conditioner to another location, make sure that air other than the specified refrigerant (R410A) does not enter the refrigeration cycle. If other air should enter, the pressure level of the refrigeration cycle may increase abnormally which could result in a rupture and injury.
• Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous gas may occur.
• After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the room, coming into contact with fire in the fan-driven heater, space heater, etc., a poisonous gas may occur.
• Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner technician or electrician. Improper repairs may result in water leakage, electric shock and fire, etc.
• Be sure to connect the earth line from the power supply wire to the outdoor unit and between the outdoor and indoor unit. Do not connect the earth line to the gas tube, water pipe, lighting rod or the earth line of the telephone unit. Improper earthing may cause electric shocks.
• When finishing the refrigerant collection (pumping down), stop the compressor and then remove the coolant pipe. If you remove the refrigerant pipe while the compressor is operating and the service valve is released, air is sucked and a pressure in the freezing cycle system will build up steeply, causing an explosion or injury.
• When installing the unit, be sure to install the refrigerant pipe before starting the compressor. If the refrigerant pipe is not installed and the compressor is operated with the service valve released, air is sucked and the pressure level of the refrigeration cycle may increase abnormally which could result in a rupture and injury.
CAUTION
• A circuit breaker must be installed in the house distribution box for the direct connected power supply cables to the outdoor unit. In case of other installations a main switch with a contact gap or more than 3mm has to be installed. Without a circuit breaker, the danger of electric shock exists.
• Do not install the unit near a location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
• Please ensure smooth flow of water when installing the drain hose. Improper installing may wet your funiture.
• An IEC approved power cord should be used. Power cord type: NYM.
INDOOR UNIT
WARNING
THE CHOICE OF MOUNTING SITE (Please note the following matters and obtain permission from customer before installation.)
• The unit should be mounted at stable, non-vibratory location which can provide full support to the unit.
CAUTION
• No nearby heat source and no obstruction near the air outlet is allowed.
• The clearance distances from top, right and left are specified in figure below.
• The location must be convenient for water drainage and pipe connection with the Outdoor unit.
• To avoid interference from noise, please place the unit and its remote controller at least 1m from the radio and television.
• To avoid any error in signal transmission from the remote controller, please put the controller far away from high­frequency machines and high-power wireless systems.
OUTDOOR UNIT
WARNING
• The Outdoor unit must be mounted at a location which can support heavy weight. Otherwise, noise and vibration will increase.
CAUTION
• Do not expose the unit under direct sunshine or rain. Besides, ventilation must be good and clear of obstruction.
• The air blown out of the unit should not point directly to animals or plants.
• The clearances of the unit from top, left, right and front are specified in figure below. At least three of the above sides must be open air.
• The installation height should be at least 2,300 mm or more from the floor.
• Be sure that the hot air blown out of the unit and noise do not disturb the neighbourhood.
• Do not install at a location where there is flammable gas, steam, oil and smoke.
• The location must be convenient for water drainage.
• Place the Outdoor unit and its connecting cord at least 1 m away from the antenna or signal line of television, radio or telephone. This is to avoid noise interference.
Names of Indoor Components
The Length of Indoor Unit
Connecting Cord
above
0.9 m
above
1.6 m
Direction of Piping
Backward piping from left
Connection There are 6 directions allowed, namely, backward piping, backward piping from left, horizontally piping from right, horizontally piping from left, vertically down from right, vertically down from left.
1
2
Figure showing the Installation of Indoor and Outdoor Unit.
above 50mm
above 250mm
above 100mm
about 300mm
about 0.45m
must not bend
The indoor piping should be insulated with the enclosed insulation pipe. (If the insulator is insufficient, please use commercial products.)
• The refrigerating machine oil is easily affected by moisture. Use caution to prevent water from entering the cycle.
• The difference in height between the indoor and outdoor unit should be kept below 5m.
• The connecting pipe, no matter big or small, should all be insulated with insulation pipe and then wrapped with vinyl tape. (The insulator will deteriorate if it is not wrapped with tape).
The connection of insulated drain hose. Inner diameter 16mm
Please use insulated drain hose for the indoor piping (commercial product)
above 100mm
above 400mm
above 150mm
give clearance as wide as possible
above
200mm
Be sure to completely seal any gap with putty.
Maximum pipe length 10m
INDOOR UNIT
1 Installation of Hanger, Wall Penetration and Installation of Protection Pipe
CAUTION
• The draining of the water container inside the Indoor unit can be done from the left. Therefore the hanger must be fixed horizontally or slightly tilted towards the side of drain hose. Otherwise, condensed water may overflow the water container.
Direct Mounting On The Wall
• Please use hidden beams in the wall to hold the hanger.
Wall hole
Weight
Line
1 Hanger
Procedures of Installation and Precautions
• Procedures to fix the hanger.
1.Drill holes on wall. (As shown below)
2.Push plug into the holes. (As shown below)
3.Fix the hanger on wall with
4.1 x 32 screw. (As shown in figure below)
Wall Penetration and Installation of Protection Pipe
• Drill a ø65mm hole on wall which is slightly tilted towards the outdoor side. Drill the wall at a small angle.
• Cut the protection pipe according to the wall thickness.
• Empty gap in the sleeve of protection pipe should be completely sealed with putty to avoid dripping of rain water into the room.
• Please ensure smooth flow of water when installing the drain hose. Improper installing may wet your funiture.
• An IEC approved power cord should be used. Power cord type: NYM.
WARNING
Be sure that the wire is not in contact with any metal in the wall. Please use the protection pipe as wire passing through the hollow part of the wall so as to prevent the possibility of damaged by mouse. Unless it seals completely, any air with high humidity flows from outdoor and any dew may drop.
Seal with putty
Protection pipe
Sleeve of protection pipe
Seal with putty
Outdoor
Indoor
2-5mm
2 Installation Of The Indoor Unit
Level
WALL
When the power is supplied from the indoor unit, pull the power cable from the cable drawer at the right or left side of the indoor unit.
32mm
Wall
ø4.8mm
1 Hanger
2 Screw
Wall
above 50mm
4.1 x 32 screw
Ceiling
Plug (Procure locally)
above 200mm
450mm
400mm 316mm
125mm
41mm
45mm
ø65mm
199mm
280mm
65mm
390mm
80mm
530mm 780mm
10mm
45mm
ø65mm
42mm
44mm
125mm
20mm
Drain Hose
Drain Hose
2 Screw for Hanger
Screw the hanger at the positions possibly near the upper and lower hooks where the indoor unit is hung. Use 4 or more screws to fix the hanger.
¡
PIPING FROM THE RIGHT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
Preparation
• Connect connecting cord.
• Pull out the pipe, connecting cord and drain hose.
Installation
• Insert the pipe through the wall hole. ¡ The upper part of the Indoor unit is hanged on the
hanger.
The projection at the lower part of the Indoor unit is
hooked onto the hanger.
Connecting cords, pipe and drain hose must be laid together with Vinyl tape.
Lift the body of the unit upwards and then force it downwards.
1 Hanger
Refrigerating Pipe
Protection Pipe
Drain Hose
Connecting Cord
1 Hanger
Projection
PIPING FROM THE LEFT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
Preparation
Changed of Drain Hose and Installation Procedures.
Exchange the location of drain hose and drain cap while installing the pipe from the left side as shown in below. Be sure to plug in the drain hose until the insulating material folds upon itself.
• Please use pliers to pull out the drain cap. (This is an easier way to remove the drain cap).
CAUTION
Insufficient insert may result in water leakage.
Drain Hose
Drain cap
Drain cap
Remove low cover
Insert drain cap up to the location securely till the cap stops.
Rib at the Indoor unit
Insulating section of the drain hose end
Cutting Low Cover bush
• While installing the pipe from the right, left or bottom side, use a knife to cut openings as shown in figure. Then smoothen the edges of openings with a file.
Openings
Push the pipe deeply until the insulating section of the drain hose end gets over the rib at the indoor unit side.
Openings
CAUTION
• The rubber strap used for fixing the insulator should not be tied with great force. Otherwise, this will damage heat insulation and causes water condensation.
• Please pull the lower part of the Indoor unit outwards to check if the unit is hooked onto the hanger. Improper installation may cause vibration and noise.
• Transform the piping while holding down the lower portion of pipe-support by hand.
Pipe
Rubber strap tied with great force
Pipe support
Transform after bending downward.
INSTALLATION AFTER CONNECTION OF REFRIGERATING PIPES
• The refrigerating pipe should be adjusted to fit into the hole on the wall and then ready for further connection.
• The terminals of 2 connected pipes must be covered with insulator used for terminal connection. Then the pipes are wrapped with insulation pipe.
• Connect the connecting cord after removing low cover. (Refer to "CONNECTION OF POWER CORD")
• After adjustment, fit the connecting cord and pipes into the space available under the unit. Use holder to hold them tight.
• Holder can be attached at the either of 2 places. Please select the easier position.
Holder
Pipe
Connecting cord
Drain hose
Insulation pipe (must be wrapped with vinyl tape at every 120 mm)
THE CONNECTION OF REFRIGERATING PIPE DURING THE INSTALLATION OF INDOOR UNIT
Preparation To Install Refrigerating Pipes
• The refrigerating pipes and connecting cord transform and are attached.
0.85m below 5mm
Please bend at a small radius to form an arc
Installation
Hang the indoor unit onto the hanger. Use the temporary stand at the back of the Indoor unit to push its lower part 15cm forwards.
• Place the drain hose through the hole on the wall.
• Wrap the refrigerating pipes with insulation pipe after connecting refrigerating pipe.
• Connect the connecting cord after removing low cover. (Refer to "Connection of Power Cord")
• After adjustment, the connecting cord and refrigerating pipes are placed into the space available under the Indoor unit.
• The projection of Indoor unit must hook to the hanger.
about 15cm
Hook
Projection
Protection pipe
Pull this to the front during the connection of refrigerating pipe to ease task.
Heat insulation pipe
Connecting cord
Holder
Connected section
Refrigerating pipe
Connecting cord
Drain hose
Wall hole
Pipe
Drain hose
Cable
4 Installation of Drain Hose
CAUTION
Be sure that the drain hose is not loosely connected bend or proper condition like left figure.
CAUTION
You are free to choose the side (left or right) for the installation of drain hose. Please ensure the smooth flow of condensed water of the Indoor unit during installation. (Careless may result in water leakage.)
Condensed water pond
Bending upwards
Condensed water pond
Ditch
• The connected terminals should be completed sealed with heat insulator and then tied up with rubber strap.
• Do not tie the terminals with the tape too tight. If any clearance or over-tightening may cause condensation.
• Please tie the pipe and power line together with vinyl tape as shown in the figure showing the installation of Indoor and Outdoor units.
• To enhance the heat insulation and to prevent water condensation, please cover the outdoor part of the drain hose and pipe with insulation pipe.
• Completely seal any gap with putty.
Insulation material for pipe connection
Sleeve of protection pipe
Putty
Putty
Cable drawer (right side)
Visible outline of the outdoor unit
Wall hole
Wall hole
Pipe
Drain hose
Cable
Drain layout of backward piping
Drain layout of backward piping from left
The end of the refrigerating pipes are at locations marked with “
” symbol.
3 Heat Insulation and Finish of the Piping
2,300 mm or more
The clearances of the unit from top, left, right and front are specified in figure below. At least three of the above sides must be open air.
¡
RAS-10GH
RAC-10GH
RAS-1 GH
RAC-1 GH
5 /
5
4
5 /
4
5
Screw for Hanger
(Φ4.1x32)
AAA Size Battery
Hanger
QtyNo. Component’s Name
1
6
2
Remote Controller
1
2
3
4
5
1
1
Drain Pipe
Dimension of Mounting
Stand of the outdoor unit
(unit : mm)
500 750
50
330
310
290
500 698
45
300
282
257
(10GH5)
(14GH5)
The installation height of the indoor unit must be at least 2300mm or more from the floor.
• Please mount the Outdoor unit of stable ground to prevent vibration and increase of noise level.
• Decide the location for piping after sorting out the different types of pipe available.
• When removing side cover, please pull the handle after undoing the hook by pulling it downward. Reinstall the side cover in the reverse order of the removal.
Please face this side (suction side) of the unit to the wall.
Please remove terminal cover when connecting the piping and connecting cord.
CONDENSED WATER DISPOSAL OF OUTDOOR UNIT
• There is holes on the base of Outdoor unit for condensed water to exhaust.
• In order to flow condensed water to the drain, the unit is installed on a stand or a block so that the unit is 100mm above the ground as shown figure. Join the drain pipe to one hole.
• After installation, check whether the drain pipe clings to the base firmly.
• Install the outdoor unit horizontally and make sure that condensate drains away.
• In case of using in chilly area Especially, in case that there are many snows by very cold in chilly area, condensed water freezes on the base and may result not to drain. In this case, please remove the bush and the drain pipe at the bottom of unit. (Left and center near discharge portion of air, each 1 place). It becomes smooth drain. Ensure that the distance from the drain hole to the ground is 250 mm or more.
CAUTION
• Remove burr and jagged edge will cause leakage.
• Point the side to be trimmed downwards during trimming to prevent copper chips from entering the pipe.
Copper pipe
Trimming tool
• Before flaring, please put on the flare nut.
A
Die
Die
Copper pipe
• Please use exclusive tool for refrigerant R410.
Outer A (mm) Rigid Flaring Tool Diameter (Ø) For R410A tool For R22 tool
6.35 (1/4") 0 - 0.5 1.0
9.52 (3/8") 0 - 0.5 1.0
2 Pipe Connection
CAUTION
• In case of removing flare nut of a indoor unit, first remove a nut of small diameter side, or a seal cap of big diameter side will fly out. Free from water into the piping when working.
• Be sure to tighten the flare nut to the specified torque with a torque wrench. If the flare nut is overtightened, the nut may be split after a long period has passed, and may cause a refrigerant leak.
• Please be careful when bending the copper pipe.
• Screw in manually while adjusting the center. After that, use a torque wrench to tighten the connection.
INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL
Torque wrench
Flare nut
Wrench
Small diameter side 6.35 (1/4") 13.7 – 18.6 (140 – 190) Large diameter side 9.52 (3/8") 34.3 – 44.1 (350 – 450)
Small diameter side
6.35 (1/4") 19.6 – 24.5 (200 – 250)
Large diameter side
9.52 (3/8") 19.6 – 24.5 (200 – 250)
Valve core cap 12.3– 15.7 (125 – 160)
Torque N·m
(kgf·cm)
Valve
head cap
3Remove of Air From The Pipe And Gas Leakage Inspection
AIR REMOVAL
Procedures of using Vacuum Pump for Air Removal
As shown in right figure, remove the cap of valve core. Then, connect the charge hose. Remove the cap of valve head. Connect the vacuum pump adapter to the vacuum pump and connect the charge hose to the adapter.
1
Fully tighter the "Hi" shuttle of the manifold valve and completely unscrew the "Lo" shuttle. Run the vacuum pump for about 10-15 minutes, then completely tighten the "Lo" shuttle and switch off the vacuum pump.
• Loosen the spindle of the service valve with small diameter by 1/4 turn and tighten the spindle immediately after 5 to 6 seconds.
• Remove the charging hose from the service valve.
2
Completely unscrew the spindle of the service valve (at 2 places) in anticlockwise direction to allow the flow of refrigerant (using Hexagonal Wrench key).
3
Tighten the cap of valve head. Check the cap's periphery if there is any gas leakage. The task is then completed.
4
When the meter reaches - 101KPa (-76cmHg) during pumping fully tighten the shuttle.
Meter showing pressure
Closed
R410A Manifold valve
Vacuum pump
Valve
Charge hose
Vacuum pump adapter
When pumping starts, slightly loosen the flare nut to check of air sucked in. Then tighten the flare nut.
The body of service valve
Cap of valve core
Hexagonal wrench Key
Cap of valve head
Gas leakage inspection
Please use gas leakage detector to check if leakage occurs at connection of Flare nut as shown on the right.
If gas leakage occurs, further tighten the connection to stop leakage.
CONNECTION OF POWER CORD
OUTDOOR UNIT
FINAL STAGE OF INSTALLATION
1Preparation of Pipe
• Use a pipe cutter to cut the copper pipe and remove burr.
How to remove the front cover How to Attach the Front Cover
¡ Check that the drain pan is securely attached.After installing the front cover onto the unit, hook three claws
at upper side of the cover securely. Then, push the center of the front cover to lock the claws.
£ Tighten the two screws.
¢ Install the filter.Slide the shafts of the right and left arms on the front panel
along the steps to insert the shafts into the holes till they stop. After checking that the shafts are securely inserted, close the panel.
¡ Remove the front panel
• Please remove and attach the front panel by both hands.
• After opening the front panel by both hands.
1 Undo the right arm while pushing it inside. 2 Slide the front panel to right as shown in figure. Then remove
while pulling it to front.
Remove the filters. £ After removing two screws, pull the center of the front cover
towards you and release the claws.
¢ Pull the side faces (lower sections) of the front cover towards
you as shown in the figure and remove the cover.
Cap of valve head
< S4249 : >
Valve
Step
Shaft
Hole
CAUTION
• Do not touch the suction port, bottom surface, or aluminum fin of the outdoor unit. Failure to do so may cause an injury.
• Push up the [PUSH] sections at the bottom of the indoor unit and pull the bottom plate towards you. Then the claws are released from the stationary plate. (The [PUSH] sections are indicated by 2 arrows in the right figure)
HOW TO REMOVE INDOOR UNIT
[PUSH] mark positions
Outer diameter
of pipe (ø)
DRAIN PIPE
DRAIN HOLE
above 100mm
BASE
Outer diameter: 16 mm or more
RAC-14GH5
RAC-10GH5
Be sure to use only wire specified for the use of air-conditioner. Please refer to the manual for wire connection and the wiring technique should meet the standards of the electrical installation. There is a AC voltage drop between the AB terminal if the power is on. Therefore, be sure to remove the plug from its socket.
THIS APPLIANCE MUST BE EARTHED.
Procedures of Wiring
Wiring Of The Outdoor Unit
Please remove the side cover for wire connection.
Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not reach the specified capacity.
Wiring Of The Indoor Unit
Procedures of Wiring Open the front panel, loosen and remove the screw at the electric box cover located at the right side of front cover. Loosen and remove the screw fixing inner cover (sheet metal). After inserting the connecting cords from the s-cover of air outlet, bend the tips of connecting cords as shown in the figure below. Fix the cords securely to the inner cover (sheet metal) according to their respective colors. (Tightening torque: 5kgf·cm). After the wiring is done, reinstall the inner cover (sheet metal) and the electric box cover accordingly.
WARNING
WARNING
RAC-14GH5
RAC-10GH5
Wire clamp for power cord
cover
white black red
yellow
A B C D
A B C D
AC 230V
A
B
C
D
5
Terminal cover
The earth line terminal of the outdoor unit is below the service valve. To avoid short circuit, it is necessary to install circuit breaker depending on the mounting location of the unit. Do not place earth line near the following objects: (1) Water pipe (2) Gas pipe — There is danger of catching fire. (3) The earth line of lightning conductor and telephone —
short ci
rcuit may occur during lightning.
CAUITON
n
The naked part of the wire core should be 10mm fix it to the terminal tightly. Then
try to pull the individual wire to check if the contact is
burn the terminal.
tight. Improper insertion may
Pull at the ¡ and in
the directions as shown
by arrows to remove the
cover.
¡
Green + Yellow
Earth Line And Circuit Breaker
Power Source And Operation Test
Power Source
CAUTION
!
Please use a new socket. Accident may occur due to the use of old socket because of poor contact.
Please plug in and then remove the plug for 2 – 3 times. This is to ensure that the plug is completely plugged into the socket.
Keep additional length for the power cord and do not render the plug under external force as this may cause poor contact.
Do not fix the power cord with U-shape nail.
Operation Test
Please ensure that the air conditioner is in normal operating condition during the operation test.
Explain to your customer the proper operation procedures as described in the user’s manual.
WARNING
If you cannot attach the side cover due to the
connecting cord, press the connecting cord in direction
to the front panel
Be sure that the hooks of the side cover is fixed in
certainly. Otherwise water leakage may occur and this
causes short
The connecting cord should not touch to service valve
and pipes. (It becomes high temperature in heating
operation.)
to fix it.
circuit or faults.
5~10mm
ABC
D
ABC
D
WARNING
• Leave some space in the connecting cord for maintenance purpose and be sure to secure it with the cord band.
• Secure the connecting cord along the coated part of the wire using the cord band. Do not exert pressure on the wire as this may cause overheating or fire.
After remove the screw and terminal cover, and put the connecting cords and fix the terminal cover with screw.
After remove the screw and terminal cover, and put the connecting cords and fix the terminal cover with screw.
1
The indoor unit is supplied with a power cord without AC power plug.Please use a AC power plug
acc. to the technical standards in your country.
The AC outlet closed to the indoor unit, electrical installation cable (3x1,5mm²) and fuse breaker
(16A) has to be installed in accordance
to the technical standards in
your country
.