To obtain the best performance and ensure years of trouble free use, please read this instruction manual
completely.
Инструкция по эксплуатации
Для обеспечения наилучших эксплуатационных характеристик и многолетней безотказной работы
оборудования необходимо ознакомиться с данной Инструкцией по эксплуатации.
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
●
Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which,
if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
●
The sign indicate the following meanings.
Make sure to connect earth line.
Indicates the instructions that must be followed.
●
Please keep this manual after reading.
PRECAUTIONS DURING INSTALLATION
● Do not reconstruct the unit.
Water leakage, fault, short circuit or fi re may occur if you reconstruct
the unit by yourself.
!
WARNING
!
CAUTION
● Please ask your sales agent or qualifi ed technician for the installation
of your unit. Water leakage, short circuit or fi re may occur if you install
the unit by yourself.
● Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor,
or the earth line of telephone. Improper installation of earth line may
cause electric shock.
● A circuit breaker should be installed depending on the mounting site of
the unit. Without a circuit breaker, the danger of electric shock exists.
● Do not install the unit near a location where there is fl ammable gas.
The outdoor unit may catch fi re if fl ammable gas leaks around it.
● Please ensure smooth fl ow of water when installing the drain hose.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
● Should abnormal situation arises (like burning smell), please stop operating the unit
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fi re may
W
occur if you continue to operate the unit under abnormal situation.
● Please contact your agent for maintenance. Improper self maintenance may cause
A
electric shock and fi re.
R
N
● Please contact your agent if you need to remove and reinstall the unit. Electric
I
shock or fi re may occur if you remove and reinstall the unit yourself improperly.
N
● If the supply cord is damaged, it must be replaced by the special cord obtainable
G
at authorized service/parts centers.
!
!
The sign in the fi gure indicates prohibition.
PRECAUTIONS DURING OPERATION
● Avoid an extended period of direct air fl ow for your health.
W
A
R
● Do not use any conductor as fuse wire, this could cause fatal accident.
N
I
N
G
● This unit has UV LED which emits ultra violet light.
AVOID DIRECT EYE EXPOSURE.
● Do not insert a fi nger, a rod or other objects into the air outlet or inlet. As
the fan is rotating at a high speed, it will cause injury. Before cleaning, be
sure to stop the operation and turn the breaker OFF.
● During thunder storm, disconnect and turn off the circuit breaker.
!
– 2 –
PRECAUTIONS DURING OPERATION
!
● The product shall be operated under the manufacturer specifi cation and
not for any other intended use.
● Do not attempt to operate the unit with wet hands, this could cause fatal
accident.
● When operating the unit with burning equipments, regularly ventilate the
room to avoid oxygen insuffi ciency.
● Do not direct the cool air coming out from the air-conditioner panel to face
household heating apparatus as this may affect the working of apparatus
such as the electric kettle, oven etc.
● Please ensure that outdoor mounting frame is always stable, fi rm and
without defect. If not, the outdoor unit may collapse and cause danger.
● Do not splash or direct water to the body of the unit when cleaning it as
this may cause short circuit.
● Do not use any aerosol or hair sprays near the indoor unit. This chemical
can adhere on heat exchanger fi n and blocked the evaporation water
fl ow to drain pan. The water will drop on tangential fan and cause water
splashing out from indoor unit.
C
A
U
● Please switch off the unit and turn off the circuit breaker during cleaning,
the high-speed fan inside the unit may cause danger.
T
I
O
● Turn off the circuit breaker if the unit is not to be operated for a long period.
N
● Do not climb on the outdoor unit or put objects on it.
ENGLISH
● Do not put water container (like vase) on the indoor unit to avoid water
dripping into the unit. Dripping water will damage the insulator inside the
unit and causes short-circuit.
● Do not place plants directly under the air fl ow as it is bad for the plants.
● When operating the unit with the door and windows opened, (the room humidity is always above
80%) and with the air defl ector facing down or moving automatically for a long period of time,
water will condense on the air defl ector and drips down occasionally. This will wet your furniture.
Therefore, do not operate under such condition for a long time.
● If the amount of heat in the room is above the cooling or heating capability of the unit (for
example: more people entering the room, using heating equipments and etc.), the preset room
temperature cannot be achieved.
● This appliance is not intended for use by young children or infi rm persons unless they have
been adequately supervised by a responsible person to ensure that they can use the appliance
safely.
● Young children should be supervised to ensure that they do not play with the appliance.
– 3 –
NAMES AND FUNCTIONS OF EACH PART
!
INDOOR UNIT
PRE-fi lter
To prevent dust from coming into the indoor unit.
(Refer page 21)
Front panel
Indoor unit indicators
Light indicator showing the operating condition.
(Refer page 5)
Horizontal defl ector
(Air Outlet)
(Refer page 16)
Remote controller
Send out operation signal to the indoor unit. So as
to operate the whole unit.
(Refer page 6)
OUTDOOR UNIT
RAC-08LH1
RAC-10LH1
RAC-14LH1
Drain pipe
Condensed water drain to outside.
●
Vertical defl ector
MODEL NAME AND DIMENSIONS
MODEL
LH1/10LH1/14LH1
RAS-08
RAS-08LH1(B)/10LH1(B)/14LH1(B)
RAC-08LH1/10LH1/14LH1
Connecting cord and insulation pipe for piping
Air inlet (Back, Left side)
Air outlet
CAUTION
● When heating operation, drain or defrosted water fl ows
out from outdoor unit. Don’t close drain outlet portion
in chilly area so as not to freeze these.
WIDTH (mm)
780
700
– 4 –
HEIGHT (mm)
280
468
DEPTH (mm)
220
258
INDOOR UNIT INDICATORS
TEMPORARY
SWITCH
TEMPORARY
SWITCH
Press
Temporary Switch
Non-conductor Stick
OPERATION INDICATOR
FILTER LAMP
When the device is operated for a total of about 100
hours, the FILTER lamp lights to indicate that it is time
to clean the fi lter. The lamp goes out when the POWER
SWITCH set to OFF and ON again.
OPERATION LAMP
This lamp lights during operation.
The OPERATION LAMP fl ashes in the following cases
during heating.
(1) During preheating
For about 2–3 minutes after starting up.
(2) During defrosting
Defrosting will be performed about once every one
hour when frost forms on the heat exchanger of the
outdoor unit, for 5–10 minutes each time.
TIMER LAMP
This lamp lights when the timer is working.
ENGLISH
TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work. [Use non-conductor stick
(example toothpick)]
● By pressing the temporary switch, the operation is done in previously set operation mode.
● When the operation is done using the temporary switch after the power source is turned off and turn
on again, the operation is done in automatic mode.
– 5 –
AUTO
HEAT
DEHUMIDIFY
COOL
FAN
FAN SPEED
LOW
MED
HI
SLEEPING
STOP (CANCEL)
START (RESERVE)
START/STOP
TIME
TIMER SET
TIMER SELECTOR
ON TIMER
OFF TIMER
AUTO SWING
˚
CH
RESET
˚
CH
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
REMOTE CONTROLLER
● This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is
controlled electronically, the range of control may be shorter.
This unit can be fi xed on a wall using the fi xture provided. Before fi xing it, make sure the indoor unit can
be controlled from the remote controller.
● Handle the remote controller with care. Dropping it or getting it wet may compromise its signal transmission
capability.
● After new batteries are inserted into the remote controller, the unit will initially require approximately 10
seconds to respond to commands and operate.
●Signal emitting window/transmission sign
Point this window toward the indoor unit when controlling it.
The transmission sign blinks when a signal is sent.
●Display
This indicates the room temperature selected, current time, timer status, function
and intensity of circulation selected.
●START/STOP button
Press this button to start operation. Press it again to stop operation.
●SLEEP button
Use this button to set the sleep timer.
●TEMPERATURE buttons
Use these buttons to raise or lower the temperature setting. (Keep pressed,
and the value will change more quickly.)
●TIME button
Use this button to set and check the time and date.
● RESET buttons
● FUNCTION selector
Use this button to select the operating mode. Every time you press it,
the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to
(COOL) and to (FAN) cyclically.
●FAN SPEED selector
This determines the fan speed. Every time you press this button, the intensity
of circulation will change from (AUTO) to (HI) to (MED) to (LOW)
(during the (FAN) mode, from HI to MED to LOW).
●AUTO SWING button
Controls the angle of the horizontal air defl ector.
●TIMER control
Use this button to set the timer.
● OFF-TIMER button Select the turn OFF time.
● ON-TIMER button Select the turn ON time.
● RESERVE button Time setting reservation.
● CANCEL button Cancel time reservation.
Precautions for Use
● Do not put the remote controller in the following places.
● Under direct sunlight.
● In the vicinity of a heater.
● Handle the remote controller carefully. Do not drop it on the fl oor,
and protect it from water.
● Once the outdoor unit stops, it will not restart for about 3 minutes
(unless you turn the power switch off and on or unplug the power
cord and plug it in again).
This is to protect the device and does not indicate a failure.
● If you press the FUNCTION selector button during operation, the
device may stop for about 3 minutes for protection.
– 6 –
AUTOMATIC OPERATION
°C
RESET
The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on
the initial room temperature. The selected mode of operation will not change when the room temperature varies.
Press the FUNCTION selector so that the display indicates the (AUTO)
mode of operation.
● When AUTO has been selected, the device will automatically determine
1
the mode of operation, HEAT, COOL or DEHUMIDIFY depending on
the initial room temperature.
ENGLISH
■Condition of Automatic Operation
Initial room temperature
(approx.)
START
STOP
■ As the settings are stored in memory in the remote controller, you only have
to press the (START/STOP) button next time.
You can raise or lower the temperature setting as necessary by maximum
of 3°C.
● The preset temperature and the actual room temperature may vary
● The display does not indicate the preset temperature in the AUTO mode.
Over 27°CCOOL
23~27°C
Under 23°CHEAT
-
-
-
DEHUMIDIFY
Press the (START/STOP) button.
Operation starts with a beep.
Press the button again to stop operation.
Press the temperature button and the temperature setting
will change by 1°C each time.
somewhat depending on conditions.
If you change the setting, the indoor unit will produce a beep.
Temperature settingFunction
27°C
Slightly lower than the
room temperature
23°C
FAN SPEED
HI at start, MED or LOW
after the preset temperature
is reached
LOW
HI at start, MED or LOW
after the preset temperature
is reached
– 7 –
HEATING OPERATION
˚
C
RESET
˚
C
● Use the device for heating when the outdoor temperature is under 21°C.
When it is too warm (over 24°C), the heating function may not work in order to protect the device.
● In order to keep reliability of the device, please use this device above –10°C of the outdoor temperature.
Press the FUNCTION selector so that the display indicates
(HEAT).
1
Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).
(AUTO) : The fan speed is HI at fi rst and varies to MED or
2
(HI) : Economical as the room will become warm
But you may feel a chill at the beginning.
(MED) : Quiet.
(LOW) : More quiet.
Set the desired room temperature with the TEMPERATURE
buttons (the display indicates the setting).
3
The temperature setting and the actual room temperature may
vary somewhat depending on conditions.
LOW automatically when the preset temperature
has been reached.
quickly.
The range of 18-22°C is recommended as the
room temperature for heating.
If the temperature setting is 20°C, the room
temperature will be controlled at around 20°C.
START
STOP
Press the (START/STOP) button. Heating operation starts
with a beep. Press the button again to stop operation.
■ As the settings are stored in memory in the remote controller, you
only have to press the (START/STOP) button next time.
– 8 –
Loading...
+ 18 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.