Hitachi RAK-18NH5, RAK-18NH6, RAK-25NH5, RAK-35NH5, RAK-50NH5 Information Booklet & User Manual

...
room air
conditioners
Models
Monozone/Multizone (NH5/NH6/NH7/QH5)
Summit (YH5/FH5/YH6)
Bigflow (GH4/G4)
Air Exchanger (JX5)
ROOM AIR
CONDITIONERS
3
Company profile 4
Standards and quality certificates 5
Product range overview 6
General features and benefits 8
Monozone/Multizone range 12
Summit range 52
Monoduct range 58
Bigflow range 60
Air Exchanger range 62
Contents
Air conditioning from Hitachi can justifiably be described as the art of exploiting the latest ideas and developments in technology to create a range of innovative products which provide a more comfortable and more productive environment in which people can happily live and work. It is also an art executed with a responsible concern for protecting the environment. Ecological thinking begins at the very first stages of new product design and continues throughout production, installation procedures, equipment and operation.
Specifiers and users alike can always be assured that performance and costs are not the only parameters by which Hitachi products can be judged.
To achieve success with such objectives on a global scale requires not only enormous resources but also a commitment to the future. As one of the largest companies in the world, Hitachi is well positioned to undertake this commitment with confidence that comes from successfully responding to the changing needs of people for over 90 years.
In Japanese, Hitachi means sunrise – we are the forefront of research and development turning new ideas and innovations into new products. Of its $81.4 billion sales worldwide in 2003, close to 5.2% was invested into research and development programs. This vast amount of money has given Hitachi the opportunity to conceive many ‘world firsts’ – examples of which include the technologically advanced and acclaimed scroll and semi-hermetic screw compressors. These have been incorporated in Hitachi’s air conditioning systems and water chillers which have revolutionised air conditioning worldwide.
The majority of our room air conditioning products are developed at our Tochigi Works in Japan. This is the main focus not only for production but also for research and development with respect to all our room air conditioning products. To assist in production and distribution worldwide we have seven affiliated production companies for room air conditioners and compressors.
Hitachi’s advanced air conditioning products are specified all over the world, wherever there is a requirement for ultimate performance and cost effective, long term reliability. A wide range of units coupled with a choice of advanced control systems mean Hitachi can provide solutions to meet every possible air conditioning application or specification. Authorised distributors all over the world contribute their own specialised technical support and practical assistance to provide individual system designs, commissioning and after sales service.
Hitachi Authorised Distributors are committed to providing an unrivalled support from a combination of experienced engineers, local product and spare parts stock,
supported in turn by on-going technical support from Hitachi.
From the initial product concept at Hitachi’s research and development facility in Japan, product development is dedicated to providing the products the customer requires. Product design and development is continuous with priority being given to the use of ecologically friendly refrigerant. To satisfy your cooling and heating requirements and to ensure the optimum indoor environment, consider Hitachi the first and last word in air conditioning.
Company profile
5
Quality control
Tochigi Works and its overseas affiliates have
acquired International Standard Quality Management System ISO9001 and ISO14001 authorisation. The Tochigi Works performs thorough product quality control using various environmental tests. Hitachi Room Air Conditioning Indoor and Outdoor units are manufactured according to this ISO certification system.
Hitachi products all carry the necessary ‘CE’ declaration markings, and also feature in the extensive
Eurovent Listing programme. Listing in the Eurovent directory helps ensure peace of mind for the installer and the end user, as it certifies the important operating parameters and performance of the units.
Summit range the units have a stylish flat panel design offering elegance and comfort to any application.
The Hitachi range of Room Air Conditioners feature a vast array of significant features all designed with the user in mind.
• High efficiency DC Inverter PAM control
• Eco friendly R410a refrigerant
• High power and performance for greater energy efficiency
• Low ambient working range -10°C for cooling, -15°C for heating
Hitachi’s new range of Room Air Conditioning systems has developed significantly in recent years following a great deal of investment in research and development and testing facilities at various Hitachi factories and laboratories, around the world.
Hitachi has continuously developed sophisticated energy saving air conditioning systems that reduce CO
2
emissions and help to protect
the global environment.
The latest Room Air Conditioning offering from Hitachi is the Framed Flat range of wall mounted units. Available in the MonoMultizone or
• Remarkably low sound levels
• Strong heating capacity under low ambient temperature conditions
• Zone by zone heating or cooling for up to four areas, and wide selection of indoor unit type and capacities
• Highest air quality
• Easy installation and servicing
• An elegant design
Product range overview
Outdoor Units
All DC Inverter PAM Monozone/Multizone Indoor Units
Non Inverter Mono Split
1.8 6.0
Capacity Range [Kw]
5.0
3.5
2.5
Framed Flat Wall
Wall
Floor
4-way Cassette
In-the-Ceiling
Monozone
*
Capacity Range [Kw]
2.5 3.5 5.0 7.5 8.8 11.0 12.06.0 15.5 17.6
Multizone
**
*
Nominal cooling capacities
**
Maximum indoor combination nominal cooling capacities
All DC Inverter PAM Mono Split
Summit Framed Flat
Capacity Range [Kw]
2.0 3.5 8.0 2.5
6.0
7.0
5.0
Summit YH5
Summit YH6
Monoduct
Air Exchanger
Bigflow – Heat Pump
Capacity Range [Kw]
2.0 3.5 2.9 5.0 6.5
Bigflow – Cooling Only
7
High Energy Efficiency
Hitachi conforms to the 2002/31/EC Directive – 92/75/EEC “Energy labelling Directive (ELD)” , which is applicable from June 2004 on all air conditioning products up to 12Kw cooling capacity. The DC inverter PAM technology helps us to achieve the ‘A’ class, the highest level of energy efficiency which is clearly indicated on the standard labelling system.
Advantages include:
Rapid start up
The variable speed compressor (inverter) enables the system to rapidly reach the desired room temperature setting. Once the desired room temperature has been achieved the compressor rotation speed is reduced, saving up to 30% in energy usage (when compared to conventional systems) without compromising comfort levels.
Improved performance
The inclusion of a DC driven motor delivers an enhanced performance over standard AC motor driven systems. This enhanced performance can be as much as 10%!
Features and benefits
Rapid Start Up
Improved Performance
PAM – Minimised loss of performance
Hitachi’s PAM (Power Active Module) control system mirrors the current pulse waveform to avoid distortion and therefore achieve almost 100% power factor to enhance power efficiency. This cutting edge device is employed in all Hitachi Mono/Multizone products for your comfort and energy saving for our environment. It ensures the efficient use of input power and minimises loss to less than 1%. The PAM range boasts an industry leading COP of more than 4.0.
All DC Inverter
As you would expect from an Industry leader such as Hitachi, we have been at the forefront of technological development and advancement. As the pioneer of ‘DC’ Inverter driven Room
Air Conditioners, our units boast the significant advantage of all DC Inverter driven compressors and fans. Enhanced inverter performance and system performance are achieved by the addition of a ‘DC’ drive.
Conventional Inverter PAM Inverter
9
High performance cooling at -10ºC and heating at -15ºC
The cooling and heating performance is even more impressive than previously. The units have been designed for cooling operation under low temperatures down to
-10°C. At outdoor temperatures as low as -15°C, the PAM controlled range of inverter split systems continue to provide high capacity heating performance.
Digital DC Scroll Compressor
The motor uses digital control to maximise PAM control performance.
• Loss during high-speed revolution is reduced thanks to digital control of the motor.
• Shaft runout during high-speed revolution is lessened by three balancers mounted on the crank shaft.
• Efficient operation with drastically reduced refrigerant leakage is ensured by the automatic compression system, in which the tip of the slewing scroll is kept in absolute contact with the fixed scroll, in addition to special processing of the scroll surface.
DC Twin Rotary Compressor
Today all Monozone and two Multizone room air conditioning units have Hitachi’s new twin rotary compressor which has even less vibration and even higher performance efficiency than conventional rotary compressors.
• Two rotating cylinders ensure well balanced rotation unlike the conventional single-rotary type, thus greatly reducing any vibration noise.
• The compressor’s operation is magnificently improved by the independent operation of the cylinders leading to greater efficiency and lower vibration.
Drawing of cylinder balance
Comparison of vibration
Single
1
Twin
1/5
Conventional single-rotary New twin-rotary
Compressor Technology
Heating at
Cooling at
Features and benefits
R410a Refrigerant
Hitachi is using the new R410a refrigerant in all of its room air conditioning products to ensure its continual environmentally friendly approach as well as the on going development of techniques for saving energy and reducing power consumption.
Air Quality
Either the SPX-CFH5 or SPX-CFH11, washable carbon and anti-bacteria air purifying filters are included in all of Hitachi’s room air conditioning products. This ensures that the micro dust, pollen particles and odours that can collect on filters can be easily removed. The filters can be washed and reused up to 20 times.
Self Diagnosis System for Easy Servicing
All air conditioning units are made with easy servicing in mind. All components can be easily reached and self diagnosis is made easy. Errors are easily identified by the blinking patterns made by lights on the LED outside the indoor and inside the outdoor units.
SPX-CH5, SPX-CH11
Breathable structure. Micro level dust is absorbed by static electricity.
Reusable after washing.
11
Nano-Titanium Filter (Air Exchanger range only)
Automatic Operational Control
In our new Air Exchanger models we have introduced the Hitachi state of the art Nano-Titanium Catalyst which dramatically improves the functions of deodourisation, bacteria elimination and anti-bacterial measures. Titanium Oxide has been used as a photocatalyst for many years but Hitachi have now enhanced it by reducing its size to a nanometer – over 1000 times smaller than ordinary bacteria agent.
This ultrafine catalyst can therefore catch smaller microbes or bacteria which may escape from other filters leading to higher air quality circulating around the room.
The comparison table easily shows the size of the Nano Titanium Catalyst in relation to other ordinary anti bacterial agents and also details the size of some common bacteria in relation to the size of the filter and showing what does get through.
The Nano-Titanium does not deteriorate or run out as particles and dead fungi do not accumulate on the surface, so it can be used semi-permanently.
Both the SPX-CFH15 and SPX-NFH1 filters are included.
Auto restart
If the auto start mode is selected at the ON/OFF switch, then the unit automatically resumes operation in the mode that was in use before it was switched off. This saves time for the user on start up and setting selection.
Auto changeover
The built-in microcomputer continuously selects the best operating mode to achieve the required heating and cooling temperature. The sensor checks the operating mode periodically to provide maximum comfort for the user. (Applicable to all DC Inverter models.)
Easy to use remote control
All units come with a standard easy to use wireless or wired remote control, equipped with 24hr timer. All commands are shown on the liquid crystal display while convenient, frequently-used functions (sleep mode timer, fan speed and louver control) can be operated with one touch buttons.
Monozone/Multizone
13
Extensive range and full indoor/outdoor compatibility
The Hitachi Multizone range was the worlds first all DC Inverter Multisplit system with zone by zone cooling or heating for up to four rooms.
Hitachi DC scroll and DC twin-rotary compressor, together with award­winning DC inverter PAM technology, aid the achievement of a system power factor of almost 100%, thus providing unparalleled performance and efficiency. The all DC Inverter system ensures extremely sensitive and accurate temperature control through fuzzy logic and offers remarkably low sound levels.
The wide range of units have been designed for cooling operation under low temperatures, down to -10°C. This feature enables cooling to be obtained even in winter on buildings with high internal heat gains due to lighting, people and machines, particularly in areas such as shops and lecture rooms. The heating operation under low temperature, down to
-15°C can also be performed.
The recent integration of Multizone and Monozone employing R410A refrigerant provides a comprehensive selection of DC inverter PAM mono and multi split systems, maintaining full compatibility of indoor unit throughout the range.
Monozone/Multizone compatible indoor unit range caters for all requirements offering wall mounted, floor standing, 60cm x 60cm cassettes, and in the ceiling duct units, designed to offer elegance and comfort to any application.
Comprehensive range/long pipe length and easy installation
You can choose and connect freely from different types of indoor and outdoor units depending on the number of rooms, width and shape of the room.
The single Monozone outdoor units work on a 20m to 30m maximum length of piping, and are made in four different capacities.
Multizone outdoor units can have a maximum chargeless piping length up to 70m when one outdoor unit is used with four indoor units in various locations. A maximum combination of indoor units can provide a wide selection of 6.5kW to 12.0kW.
Main Key Benefits
• DC Inverter PAM control
• Wide selection of indoor unit types and capacities
• Compatibility between product ranges of outdoor and indoor units
• Highest COP and low noise
• Cooling available under -10°C ambient temperature*
• Heating available under -15°C ambient temperature
• Auto restart by previous mode and Auto changeover**
• Washable carbon and anti-bacteria air purifying filter
• 24hr remote control timer
• R410a refrigerant
Notes: * Except RAM 80QH5 ** Auto changeover for Monozone only
In the Ceiling
60cm x 60cm Cassette
Floor Mounted
Framed Flat Wall Mounted
Outdoor Unit
Hitachi’s R410A All DC Inverter Ranges elevate air conditioning to a new level, incorporating significant advances in electronics technology.
With cooling and heating capacities from 2.0kW to 5.0kW, the all DC Inverter PAM driven mono split Monozone/Multizone Framed Flat range incorporates the R410A refrigerant, Hitachi DC Scroll, or DC Twin Rotary compressor all working together for high performance and ultimate efficiency.
• New Flat Framed design
• DC inverter PAM control
• Low noise down to 20dBA on sleep mode
• Heating available even at -15ºC ambient temperature
• Auto restart and Auto changeover
• Washable carbon and anti-bacteria air purifying filter
• 24hr remote control timer
• R410A refrigerant
RAK Technical Description
Framed flat wall mounted
15
General Data
Model RAK-18NH6 RAK-25NH6 RAK-35NH6 RAK-50NH6
Power Supply DC35V DC35V DC35V DC35V Sound Pressure Level (Overall Scale)
Cooling dBA 35/30/26/20 38/32/26/20 41/35/29/25 47/39/31/27 Heating dBA 36/33/27/23 39/33/27/23 41/35/30/26 47/39/31/27
Outer Dimensions (Net/(Carton))
Height mm 280(279) 280(279) 280(279) 280(279) Width mm 780(828) 780(828) 780(828) 780(828) Depth mm 220(341) 220(341) 220(341) 220(341) Weight Kg 9.5(13) 9.5(13) 9.5(13) 9.5(13)
Refrigerant R410A R410A R410A R410A
Flow Control ––––
Indoor Fan
Air Flow Rate Cooling m
3
/min 7.3/6.7/5.8 8.5/7.0/6.0 10.1/8.0/6.5 13.5/10.0/6.8
Air Flow Rate Heating m
3
/min 8.0/7.0/5.8 9.5/8.0/7.0 10.8/8.5/7.5 13.5/10.0/6.8
Refrigerant Piping
Liquid Line mm (in) 6.35(1/4) 6.35(1/4) 6.35(1/4) 6.35(1/4) Gas Line mm (in) 9.52(3/8) 9.52(3/8) 9.52(3/8) 12.7(1/2)
Interconnection Wires pcs3333 Auto Restart by Previous Mode Yes Yes Yes Yes LED Self Diagnosis Yes Yes Yes Yes Air Purifying Filter Type SPX-CFH11 SPX-CFH11 SPX-CFH11 SPX-CFH11 Anti-bacterial Tangential Fan Ye s Yes Yes Yes Remote Control Hr 24 24 24 24
NOTES:
Cooling Operation Conditions Heating Capacity Conditions
Indoor Air Inlet Temperature: 27 ˚C DB Indoor Air Inlet Temperature: 20 ˚C DB
19 ˚C WB
Outdoor Air Inlet Temperature: 35 ˚C DB Outdoor Air Inlet Temperature: 7 ˚C DB
6 ˚C WB
Piping Length: 7.5 meters Piping Length: 7.5 meters Piping Lift: 0 meters Piping Lift: 0 meters
Powerful
A bigger, compact flap delivers air quickly to every corner of the room and the powerful, sweeping air flow eliminates dead zones and improves the cooling and heating effect.
Silent
The trapezoidal blades cut the air diagonally to minimise air resistance and the conical blade fan ensures a high airflow. With this diagonal air blow, less friction is caused, which reduces noise and improves efficiency. The fan diameter has been increased from the conventional 90mm to 100mm.
Efficient
The Lambda- shaped heat exchanger’s advanced design has a wide suction area and graduation – design grill which both increase the efficiency and performance of the heat exchanger. The wide suction area increases the air intake which enables the unit to adjust the room temperature quickly.
Clean
A washable carbon and anti-bacteria air purifying filter ensures that the micro dust, pollen particles and odours that can collect on filters can be easily removed. The filters can be washed and reused up to 20 times.
• Powerful
• Silent
Efficient
Clean
RAK Technical Description
Wall mounted
With diagonal air blow, less friction is caused, which reduces noise and improves efficiency.
Conventional blade fan
New Conical blade fan
Wide and Big Air Flap
17
General Data
Model RAK-18NH5 RAK-25NH5 RAK-35NH5 RAK-50NH5 RAK-65NH5
Power Supply DC 35V DC 35V DC 35V DC 35V DC 35V
Sound Pressure Level (Overall Scale)
Cooling dBA 35/30/26/20 38/32/26/20 41/35/29/25 47/39/31/27 47/42/33/28
Heating dBA 36/33/27/23 39/33/27/23 41/35/30/26 47/39/31/27 47/42/34/33
Outer Dimensions (Net/(Carton)
Height mm 280(254) 280(254) 280(254) 280(254) 295(271)
Width mm 780(826) 780(826) 780(826) 780(826) 1030(1100)
Depth mm 210(325) 210(325) 210(325) 210(325) 191(368)
Weight Kg 9(11) 9.5(11) 9.5(11) 9.5(11) 11(13)
Refrigerant R410A R410A R410A R410A R410A
Flow Control –––––
Indoor Fan
Air Flow Rate Cooling m
3
/min 7.3/6.7/5.8 8.5/7.0/6.0 10.1/8.0/6.5 13.5/10.0/6.8 13.5/12.5/11.3
Air Flow Rate Heating m
3
/min 8.0/7.0/5.8 9.5/8.0/7.0 10.8/8.5/7.5 13.5/10.0/6.8 13.5/12.5/11.3
Refrigerant Piping
Liquid Line mm (in) 6.35(1/4) 6.35(1/4) 6.35(1/4) 6.35(1/4) 6.35(1/4)
Gas Line mm (in) 9.52(3/8) 9.52(3/8) 9.52(3/8) 12.7(1/2) 12.7(1/2)
Interconnection wires pcs33333
Auto Restart by Previous Mode Yes Yes Yes Yes Yes
LED Self Diagnosis Yes Yes Yes Yes Yes
Air Purifying Filter Type SPX-CFH11 SPX-CFH11 SPX-CFH11 SPX-CFH11 SPX-CFH5
Anti-bacterial Tangential Fan Ye s Yes Yes Yes Yes
Remote Control Timer Hr 24 24 24 24 24
MULTIZONE combination. For capacity information please refer to Combination Table
NOTES:
Cooling Operation Conditions Heating Capacity Conditions
Indoor Air Inlet Temperature: 27 ˚C DB Indoor Air Inlet Temperature: 20 ˚C DB
19 ˚C WB
Outdoor Air Inlet Temperature: 35 ˚C DB Outdoor Air Inlet Temperature: 7 ˚C DB
6 ˚C WB
Piping Length: 7.5 meters Sound Pressure Level Measurement Distance: Piping Lift: 0 meters 1m from discharge grille
0.8m beneath the unit’s height centre
Comfortable heating
The air flow from the upper and lower outlets enables the whole room to be heated evenly, from the floor to the ceiling.
Large and gentle air flow is generated by the larger upper blades, achieving efficient air conditioning.
Easy cleaning
The waved shape of the pre-filter provides a dust collecting area which is almost three times larger than that of a conventional one. It can easily be removed for washing or cleaning by a vacuum cleaner.
High performance
The larger conical blade fan rotates the air flow slowly, thus achieving high efficiency and low noise.
RAF Technical Description
Floor mounted
The dust collecting area is almost three times larger than that of conventional one
A washable air purifying filter (option) can be installed
Pre-filter can be removed easily
open
New long life pre-filter
Current Fan New Fan
Diameter of blade fan
Conventional blade fan
New Conical blade fan
19
Model RAF-25NH5 RAF-35NH5 RAF-50NH5
Power Supply DC 35V DC 35V DC 35V
Sound Pressure Level (Overall Scale)
Cooling dBA 35/31/26/23 40/35/28/24 44/37/28/24
Heating dBA 35/31/26/25 41/35/31/26 44/39/34/31
Outer Dimensions (Net/(Carton)
Height mm 600(656) 600(656) 600(656)
Width mm 750(797) 750(797) 750(797)
Depth mm 215(278) 215(278) 215(278)
Weight Kg 15(17) 15(17) 15(17)
Refrigerant R410A R410A R410A
Flow Control –––
Indoor Fan
Air Flow Rate Cooling m
3
/min 7.2/5.0/4.5 9.5/5.5/5.0 10.3/8.5/6.0
Air Flow Rate Heating m
3
/min 8.7/7.5/6.2 10.8/8.5/7.2 12.3/10.0/7.5
Refrigerant Piping
Liquid Line mm (in) 6.35 (1/4) 6.35 (1/4) 6.35(1/4)
Gas Line mm (in) 9.52 (3/8) 9.52 (3/8) 12.7(1/2)
Interconnection wires pcs 3 3 3
Auto Restart by Previous Mode Yes Yes Yes
LED Self Diagnosis Yes Yes Yes
Air Purifying Filter Type (SPX-CFH5)* (SPX-CFH5)* (SPX-CFH5)*
Anti-bacterial Tangential Fan –––
Remote Control Timer Hr 24 24 24
MULTIZONE combination. For capacity information please refer to Combination Table *Option. Not included
General Data
NOTES:
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27 ˚C DB Indoor Air Inlet Temperature: 20 ˚C DB
19 ˚C WB
Outdoor Air Inlet Temperature: 35 ˚C DB Outdoor Air Inlet Temperature: 7 ˚C DB
6 ˚C WB
Piping Length: 7.5 meters Sound Pressure Level Measurement Distance: Piping Lift: 0 meters 1m from discharge grille
Half of unit height from floor level
Fits into 60cm x 60cm ceiling module
With it’s the compact design the 60cm x 60cm ceiling unit neatly fits inside a standard ceiling module which minimises the installation work.
Silent
The noise level is just 25dB (sleep mode) thanks to the 3D – twisted wing design of the compact turbo-fan.
Flexible air flow system
The user can select between 2-way, 3-way or 4 way operation of auto swing louvers.
Built in drain pump
This ductable unit is equipped with an internal drain pump to remove accumulated condensation water from the drain pan even while it is operating. A float switch monitors the water level and automatically activates the pump as necessary.
One-touch panel
The panel can be swung open up to 90º with just one push so that the filter can be removed for cleaning.
RAI Technical Description
60cm x 60cm cassette
2-way 3-way 4-way
21
General Data
Model RAI-25NH5 RAI-35NH5 RAI-50NH5 RAI-ECPM
Power Supply DC 35V DC 35V DC 35V DC 35V
Sound Pressure Level (Overall Scale)
Cooling dBA 35/32/29/25 39/34/29/26 43/35/32/29
Heating dBA 36/33/30/27 40/36/32/29 43/36/32/30
Outer Dimensions (Net/(Carton)
Height mm 285(395) 285(395) 285(395) 650(710)
Width mm 580(760) 580(760) 580(760) 650(710)
Depth mm 580(706) 580(706) 580(706) 32(124)
Weight Kg 20(25) 20(25) 20(25) 4(5)
Refrigerant R410A R410A R410A
Flow Control ––––
Indoor Fan
Air Flow Rate Cooling m
3
/min 8.5/7.0/5.8 10.8/8.0/5.8 12.0/8.0/5.8
Air Flow Rate Heating m
3
/min 8.5/7.0/5.8 10.8/8.0/5.8 12.0/8.0/5.8
Refrigerant Piping
Liquid Line mm (in) 6.35 (1/4) 6.35 (1/4) 6.35(1/4)
Gas Line mm (in) 9.52 (3/8) 9.52 (3/8) 12.7(1/2)
Interconnection wires pcs3333
Auto Restart by Previous Mode Yes Yes Yes Yes
LED Self Diagnosis Yes Yes Yes Yes
Air Purifying Filter Type (SPX-CFH5)*
Anti-bacterial Tangential Fan ––––
Remote Control Timer Hr 24 24 24
MULTIZONE combination. For capacity information please refer to Combination Table *Option. Not included
NOTES:
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27 ˚C DB Indoor Air Inlet Temperature: 20 ˚C DB
19 ˚C WB
Outdoor Air Inlet Temperature: 35 ˚C DB Outdoor Air Inlet Temperature: 7 ˚C DB
6 ˚C WB
Piping Length: 7.5 meters Sound Pressure Level Measurement Distance: Piping Lift: 0 meters 1.4m from beneath the unit
Loading...