Hitachi RAS-30CHP6, RAC-30CHP6, RAS-63CHA4, RAC-63CHA4 Instruction Manual

RAS-30CHP6
Instruction manual Page 1~26
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
ULOKF²« VO²≤∑≠µ≤ ’
Ÿö?Þù« V−¹ VDŽ ÊËbÐ WK¹uÞ …b* “UN'« ‰ULF²Ý« sJ1 wJ
RAC-30CHP6
SPLIT TYPE
INDOOR UNIT/OUTDOOR UNIT
MODEL
RAS-30CHP6/RAC-30CHP6
INDOOR UNIT
OUTDOOR UNIT
<
H224: A
>
Made in Malaysia
2
SAFETY PRECAUTION
Please read the Safety Precaution carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of Warning and Caution. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The sign indicate the following meanings.
Please keep this manual after reading.
WARNING
PRECAUTIONS DURING INSTALLATION
Do not reconstruct the unit. Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by yourself.
Please ask your sales agent or qualified technician for the installation of your unit. Water leakage, short circuit or fire may occur if you install the unit by yourself.
Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
Do not install near location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose.
CAUTION
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air flow for your health.
W
A R N
I
N
G
Should abnormal situation arises (like burning smell), please stop operating the unit and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock and fire.
Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
Do not insert a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn the breaker OFF.
During thunder storm, disconnect and turn off the circuit breaker.
Do not use any conductor as fuse wire, this could cause fatal accident.
Make sure to connect earth line.
Indicates the instructions that must be followed.
The sign in the figure indicates prohibition.
W
A R N
I N G
This unit has UV LED which emits ultra violet light. AVOID DIRECT EYE EXPOSURE.
3
ENGLISH
PRECAUTIONS DURING OPERATION
Do not attempt to operate the unit with wet hands, this could cause fatal accident.
When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
Do not use any aerosol or hair sprays near the indoor unit. This chemical can adhere on heat exchanger fin and blocked the evaporation water flow to drain pan. The water will drop on tangential fan and cause water splashing out from indoor unit.
Please ensure that outdoor mounting frame is always stable, firm and without defect. If not, the outdoor unit may collapse and cause danger.
Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit.
When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automatically for a long period of time, water will condense on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
Do not climb on the outdoor unit or put objects on it.
Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause danger.
Turn off the circuit breaker if the unit is not to be operated for a long period.
C A U T
I O N
The product shall be operated under the manufacturer specification and not for any other intended use.
Do not put water container (like vase) on the indoor unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and causes short-circuit.
Do not place plants directly under the air flow as it is bad for the plants.
This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
4
INDOOR UNIT
OUTDOOR UNIT
WIDTH (mm)
1150
925
MODEL
RAS-30CHP6
RAC-30CHP6
HEIGHT (mm)
333
875
DEPTH (mm)
245
315
MODEL NAME AND DIMENSIONS
NAMES AND FUNCTIONS OF EACH PART
AIR FILTER
To prevent dust from coming into the indoor unit. (Refer page 21)
FRONT PANEL (AIR INLET).
INDOOR UNIT INDICATORS
Light indicator showing the operating condition. (Refer page 5)
HORIZONTAL DEFLECTOR
VERTICAL DEFLECTOR (AIR OUTLET)
(Refer page 16)
REMOTE CONTROLLER
Send out operation signal to the indoor unit. So as to operate the whole unit. (Refer page 6)
AIR INLET (BACK, LEFT SIDE)
AIR OUTLET
Blow out warm air.
5
ENGLISH
Press
Temporary Switch
Non-conductor Stick
INDOOR UNIT INDICATORS
TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work. [Use non-conductor stick (example toothpick)]
By pressing the temporary switch, the operation is
done in previously set operation mode.
When the operation is done using the temporary switch
after the power source is turned off and turn on again, the operation is done in automatic mode.
OPERATION INDICATOR
TIMER LAMP
This lamp lights when the timer is working.
OPERATION LAMP
This lamp lights during operation.
FILTER LAMP
When the device is operated for a total of about 200 hours, the FILTER lamp lights to indicate that it is time to clean the filter. The lamp goes out when the (AUTO SWING) button is pressed while the device is on STANDBY MODE”.
– 6 –
NAMES AND FUNCTIONS OF EACH PART
REMOTE CONTROLLER
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
Signal emitting window/transmission sign
Point this window toward the indoor unit when controlling it. The transmission sign blinks when a signal is sent.
Display
This indicates the room temperature selected, current time, timer status, function and intensity of circulation selected.
START/STOP button
Press this button to start operation. Press it again to stop operation.
FAN SPEED selector
This determines the fan speed. Every time you press this button, the intensity of circulation will change from (AUTO) to (HI) to (MED) to (LOW) (during the (FAN) mode, from HI to MED to LOW).
AUTO SWING button
Controls the angle of the horizontal air deflector.
TEMPERATURE buttons
Use these buttons to raise or lower the temperature setting. (Keep pressed, and the value will change more quickly.)
SLEEP button
Use this button to set the sleep timer.
TIME button
Use this button to set and check the time and date.
RESET buttons
FUNCTION selector
Use this button to select the operating mode. Every time you press it, the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to
(COOL) and to (FAN) cyclically.
PARALLEL SWING button
Controls the angle of the vertical air deflectors to parallel.
SYMMETRY SWING button
Controls the angle of the vertical air deflectors to symmetry.
TIMER control
Use this button to set the timer.
OFF-TIMER button Select the turn OFF time.
ON-TIMER button Select the turn ON time.
RESERVE button Time setting reservation.
CANCEL button Cancel time reservation.
Precautions for Use
Do not put the remote controller in the following places.
In direct sunlight.
In the vicinity of a heater.
Handle the remote controller carefully. Do not drop it on the floor,
and protect it from water.
Once the outdoor unit stops, it will not restart for about 3 minutes
(unless you turn the power switch off and on or unplug the power cord and plug it in again).
This is to protect the device and does not indicate a failure.
If you press the FUNCTION selector button during operation, the
device may stop for about 3 minutes for protection.
– 7 –
ENGLISH
AUTOMATIC OPERATION
The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the initial room temperature. The selected mode of operation will not change when the room temperature varies.
As the settings are stored in memory in the remote controller, you only have to press the (START/STOP) button next time.
Press the FUNCTION selector so that the display indicates the (AUTO) mode of operation.
When AUTO has been selected, the device will automatically determine
the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the current room temperature.
Press the (START/STOP) button. Operation starts with a beep. Press the button again to stop operation.
You can raise or lower the temperature setting as necessary by maximum of 3°C.
Press the temperature button and the temperature setting will change by 1°C each time.
The preset temperature and the actual room temperature may vary
somewhat depending on conditions.
The display does not indicate the preset temperature in the AUTO mode.
If you change the setting, the indoor unit will produce a beep.
1
START
STOP
°C
RESET
Over 27°C COOL
23~27°C
Under 23°C HEAT
Temperature settingFunction
27°C
23°C
Slightly lower than the room temperature
LOW
FAN SPEED
HI at start, MED or LOW after the preset temperature is reached
HI at start, MED or LOW after the preset temperature is reached
-
-
DEHUMIDIFY
-
Initial room temperature (approx.)
Condition of Automatic Operation
– 8 –
HEATING OPERATION
Use the device for heating when the outdoor temperature is under 21°C.
When it is too warm (over 21°C), the heating function may not work in order to protect the device.
Press the FUNCTION selector so that the display indicates (HEAT).
Set the desired FAN SPEED with the (FAN SPEED) button (the display indicates the setting).
(AUTO): The fan speed is HI at first and varies to
MED or LOW automatically when the preset temperature has been reached.
(HI) : Economical as the room will become warm
quickly. But you may feel a chill at the beginning.
(MED) : Quiet.
(LOW) : More quiet.
Set the desired room temperature with the TEMPERATURE buttons (the display indicates the setting).
The range of 18-22°C is recommended as the room temperature for heating. If the temperature setting is 20°C, the room temperature will be controlled at around 20°C.
The temperature setting and the actual room temperature may vary somewhat depending on conditions.
Press the (START/STOP) button. Heating operation starts with a beep. Press the button again to stop operation.
As the settings are stored in memory in the remote controller, you only have to press the (START/STOP) button next time.
1
2
3
START
STOP
Loading...
+ 18 hidden pages