![](/html/7d/7d63/7d63c67c25b00f04c2b5fef7f39cb5be496a8135c3362e2db1584dadd373374c/bg1.png)
SPLIT TYPE
INDOOR UNIT/OUTDOOR UNIT
MODEL
RAS-19JP4/RAC-19JP4
RAS-24JP4/RAC-24JP4
OUTDOOR UNIT
RAC-19JP4
RAC-24JP4
Instruction manual Page 1~22
To obtain the best performance and ensure years of
trouble free use, please read this instruction manual
completely.
INDOOR UNIT
RAS-19JP4
RAS-24JP4
تﺎﻤﻴﻠﻌﺘﻟا ﺐﻴﺘﻛ٢٢-١ ص
ﻮـﻃ ةﺪﳌ زﺎﻬﳉا لﺎﻤﻌﺘﺳا ﻦﻜﳝ ﻲﻜﻟعﻼﻃﻹا ﺐﺠﻳ ﺐﻄﻋ نوﺪﺑ ﺔﻠﻳ
.اﺪﻴﺟ ﺐﻴﺘﻜﻟا اﺬﻫ ﻰﻠﻋ
RAS/RAC 19/24JP4(ENG COVER) 17/2/09, 3:13 PM1
![](/html/7d/7d63/7d63c67c25b00f04c2b5fef7f39cb5be496a8135c3362e2db1584dadd373374c/bg2.png)
– 2 –
!
SAFETY PRECAUTION
●
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
●
Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which,
if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
●
The sign indicate the following meanings.
●
Please keep this manual after reading.
WARNING
PRECAUTIONS DURING INSTALLATION
●
Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct
the unit by yourself.
●
Please ask your sales agent or qualified technician for the installation
of your unit. Water leakage, short circuit or fire may occur if you install
the unit by yourself.
●
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor,
or the earth line of telephone. Improper installation of earth line may
cause electric shock.
●
A circuit breaker should be installed depending on the mounting site of
the unit. Without a circuit breaker, the danger of electric shock exists.
●
Do not install near location where there is flammable gas. The outdoor
unit may catch fire if flammable gas leaks around it.
●
Please ensure smooth flow of water when installing the drain hose.
CAUTION
PRECAUTIONS DURING OPERATION
●
Avoid an extended period of direct air flow for your health.
W
A
R
N
I
N
G
●
Do not insert a finger, a rod or other objects into the air outlet or inlet. As the fan
is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop the
operation and turn the breaker OFF.
●
During thunder storm, disconnect and turn off the circuit breaker.
●
Do not use any conductor as fuse wire, this could cause fatal accident.
!
Make sure to connect earth line.
Indicates the instructions that must be followed.
The sign in the figure indicates prohibition.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
●
Should abnormal situation arises (like burning smell), please stop operating the unit
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may
occur if you continue to operate the unit under abnormal situation.
●
Please contact your agent for maintenance. Improper self maintenance may cause
electric shock and fire.
●
Please contact your agent if you need to remove and reinstall the unit. Electric
shock or fire may occur if you remove and reinstall the unit yourself improperly.
●
If the supply cord is damaged, it must be replaced by the special cord obtainable
at authorized service/parts centers.
W
A
R
N
I
N
G
!
(EN1) RAS-19/24JP4 (1-5) 17/2/09, 14:452
Black
![](/html/7d/7d63/7d63c67c25b00f04c2b5fef7f39cb5be496a8135c3362e2db1584dadd373374c/bg3.png)
– 3 –
ENGLISH
PRECAUTIONS DURING OPERATION
●
Do not attempt to operate the unit with wet hands, this could cause fatal
accident.
●
When operating the unit with burning equipments, regularly ventilate the
room to avoid oxygen insufficiency.
●
Do not direct the cool air coming out from the air-conditioner panel to face
household heating apparatus as this may affect the working of apparatus
such as the electric kettle, oven etc.
●
Do not use any aerosol or hair sprays near the indoor unit. This chemical
can adhere on heat exchanger fin and blocked the evaporation water flow
to drain pan. The water will drop on tangential fan and cause water splashing
out from indoor unit.
●
Please ensure that outdoor mounting frame is always stable, firm and
without defect. If not, the outdoor unit may collapse and cause danger.
●
Do not splash or direct water to the body of the unit when cleaning it as this
may cause short circuit.
●
When operating the unit with the door and windows opened, (the room humidity is always above
80%) and with the air deflector facing down or moving automatically for a long period of time,
water will condense on the air deflector and drips down occasionally. This will wet your furniture.
Therefore, do not operate under such condition for a long time.
●
If the amount of heat in the room is above the cooling or heating capability of the unit (for
example: more people entering the room, using heating equipments and etc.), the preset room
temperature cannot be achieved.
●
This appliance is not intended for use by young children or infirm persons unless they have been
adequately supervised by a responsible person to ensure that they can use the appliance safely.
●
Young children should be supervised to ensure that they do not play with the appliance.
●
Do not climb on the outdoor unit or put objects on it.
●
Please switch off the unit and turn off the circuit breaker during cleaning, the
high-speed fan inside the unit may cause danger.
●
Turn off the circuit breaker if the unit is not to be operated for a long period.
C
A
U
T
I
O
N
!
●
The product shall be operated under the manufacturer specification and
not for any other intended use.
●
Do not put water container (like vase) on the indoor unit to avoid water
dripping into the unit. Dripping water will damage the insulator inside the unit
and causes short-circuit.
●
Do not place plants directly under the air flow as it is bad for the plants.
(EN1) RAS-19/24JP4 (1-5) 17/2/09, 14:453
Black
![](/html/7d/7d63/7d63c67c25b00f04c2b5fef7f39cb5be496a8135c3362e2db1584dadd373374c/bg4.png)
– 4 –
INDOOR UNIT
NAMES AND FUNCTIONS OF EACH PART
Air filter
To prevent dust from coming into the indoor unit.
(Refer page 17)
Front panel
Indoor unit indicators
Light indicator showing the operating condition.
(Refer page 5)
Horizontal deflector
●
Vertical deflector
(Air Outlet)
(Refer page 12)
Remote controller
Send out operation signal to the indoor unit. So as to
operate the whole unit.
(Refer page 6)
OUTDOOR UNIT
Drain pipe
Condensed water drain to outside.
Connecting cord and insulation pipe for piping
Air inlet (Back and Left side)
Air outlet
WIDTH (mm)
1030
850
MODEL
RAS-19JP4 / RAS-24JP4
RAC-19JP4 / RAC-24JP4
HEIGHT (mm)
295
650
DEPTH (mm)
207
298
MODEL NAME AND DIMENSIONS
(EN1) RAS-19/24JP4 (1-5) 17/2/09, 14:454
Black
![](/html/7d/7d63/7d63c67c25b00f04c2b5fef7f39cb5be496a8135c3362e2db1584dadd373374c/bg5.png)
– 5 –
ENGLISH
INDOOR UNIT INDICATORS
OPERATION INDICATOR
● This figure shows the opening condition of
front panel. Refer to page 16 in relation to
how to open or close the front panel.
OPERATION LAMP
This lamp lights during operation.
TIMER LAMP
This lamp lights when the timer is working.
FILTER LAMP
When the device is operated for a total of about 200
hours, the FILTER lamp lights to indicate that it is time
to clean the filter. The lamp goes out when the POWER
SWITCH set to OFF and ON again.
TEMPORARY
SWITCH
TEMPORARY
SWITCH
HITACHI
TEMPORARY SWITCH
● Use this switch to start and stop when the remote controller does not work.
● By pressing the temporary switch, the operation is done in automatic mode.
(EN1) RAS-19/24JP4 (1-5) 17/2/09, 14:455
Black
![](/html/7d/7d63/7d63c67c25b00f04c2b5fef7f39cb5be496a8135c3362e2db1584dadd373374c/bg6.png)
– 6 –
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
REMOTE CONTROLLER
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting
is controlled electronically, the range of control may be shorter.
This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can
be controlled from the remote controller.
●
Transmission sign
The transmission sign blinks when a signal is sent.
●
Display
This indicates the room temperature selected, timer status, function
and intensity of circulation selected.
●
CIRCULATION button
Use this button to set air circulation in the room or start operation.
●
DEHUMIDIFYING button
Use this button to reduce humidity in the room or start operation.
●
COOLING button
Use this button to set cooling mode in the room or start operation.
●
RESET button
●
STOP button
Press this button to stop operation only.
●
SLEEP button
Use this button to set the sleep timer.
●
FAN SPEED selector
This determines the fan speed. Every time you press this button,
the intensity of circulation will change from (AUTO) to (HI)
to (MED) to (LOW).
●
AUTO SWING button
Controls the angle of the horizontal air deflector.
●
TEMPERATURE button
Use this button to raise or lower the temperature setting. (Keep
pressed, and the value will change more quickly.)
●
OFF-TIMER button Select to turn OFF time.
●
ON-TIMER button Select to turn ON time.
Precautions for Use
●
Do not put the remote controller in the following places.
●
In direct sunlight.
●
In the vicinity of a heater.
●
Handle the remote controller carefully. Do not drop it on the
floor, and protect it from water.
●
Once the outdoor unit stops, it will not restart for about 3 minutes
(unless you turn the power switch off and on or unplug the
power cord and plug it in again).
This is to protect the device and does not indicate a failure.
CIRCULATION / START
DEHUMIDIFY / START
COOLING / START
FAN
FAN SPEED
LOW
MED
HI
SLEEP TIMER
STOP
TIMER SELECTOR
ON TIMER
OFF TIMER
AUTO SWING
(EN2) RAS-19/24JP4 (6-12) 17/2/09, 14:466
Black
![](/html/7d/7d63/7d63c67c25b00f04c2b5fef7f39cb5be496a8135c3362e2db1584dadd373374c/bg7.png)
– 7 –
ENGLISH
COOLING OPERATION
Use the device for cooling when the outdoor temperature is 21-54°C.
If indoor humidity is very high (over 80%), some dew may form on the air outlet grille of the indoor unit.
Press the button so that the display indicates
(COOL).
Cooling operation starts with a beep.
The cooling function does not start if the temperature setting is
higher than the current room temperature (even though the
(OPERATION) lamp lights). The cooling function will start as
soon as you set the temperature below the current room
temperature.
Set the desired FAN SPEED with the
(FAN SPEED) button
(the display indicates the setting).
(AUTO): The FAN SPEED is HI at first and varies to
MED or LOW automatically when the preset
temperature has been reached.
(HI) : Economical as the room will become cool
quickly.
(MED) : Fan speed slow.
(LOW) : Fan speed slower.
Set the desired room temperature with the TEMPERATURE
button (the display indicates the setting).
The range of 25-28°C is recommended as the
room temperature for cooling.
If the temperature setting is 27°C, the room
temperature will be controlled at around 27°C.
The temperature setting and the actual room temperature may
vary somewhat depending on conditions.
Press the
(STOP) button to stop operation.
■ As the settings are stored in memory in the remote controller, you
only have to press the
(COOLING) button next time.
1
2
STOP
3
(EN2) RAS-19/24JP4 (6-12) 17/2/09, 14:467
Black