Hitachi RAS-10C9G, RAC-10C9G, RAS-13C9G, RAC-13C9G Instruction Manual

– 1 –
ENGLISH
INDOOR UNIT/OUTDOOR UNIT
MODEL
RAS-10C9G/RAC-10C9G RAS-13C9G/RAC-13C9G
OUTDOOR UNIT
INDOOR UNIT
SPLIT TYPE AIR CONDITIONER
Instruction manual Page 1~20
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
Arahan pengendalian Muka surat 21~40
Untuk mendapatkan prestasi yang tinggi dan mengelakkan masalah untuk jangka masa yang lama, sila baca arahan ini sepenuhnya.
– 2 –
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air flow for your health.
W
A R N
I N G
Do not put objects like thin rods into the panel of blower and suction side because the high-speed fan inside may cause danger.
During thunder storm, disconnect and turn off the circuit breaker.
Do not use any conductor as fuse wire, this could cause fatal accident.
!
SAFETY PRECAUTION
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The sign indicate the following meanings.
Please keep this manual after reading.
WARNING
PRECAUTIONS DURING INSTALLATION
Do not reconstruct the unit. Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by yourself.
Please ask your sales agent or qualified technician for the installation of your unit. Water leakage, short circuit or fire may occur if you install the unit by yourself.
Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or
the earth line of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
Do not install near location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose.
CAUTION
!
!
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
Should abnormal situation arises (like burning smell), please stop operating the unit and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock and fire.
Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
If the supply cord is damaged, it must be replaced by the special cord obtainable at authorized service/parts centers.
!
Make sure to connect earth line.
Indicates the instructions that must be followed.
The sign in the figure indicates prohibition.
W
A R N
I N G
!
– 3 –
ENGLISH
PRECAUTIONS DURING OPERATION
Do not attempt to operate the unit with wet hands, this could cause fatal accident.
When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
Do not place plants directly under the air flow as it is bad for the plants.
Please ensure that outdoor mounting frame is always stable, firm and without defect. If not, the outdoor unit may collapse and cause danger.
Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit.
When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automatically for a long period of time, water will condense on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
Do not climb on the outdoor unit or put objects on it.
Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause danger.
Turn off the circuit breaker if the unit is not to be operated for a long period.
C A U
T
I O N
The product shall be operated under the manufacturer specification and not for any other intended use.
Do not put water container (like vase) on the indoor unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and causes short-circuit.
Do not use any aerosol or hair sprays near the indoor unit. This chemical can adhere on heat exchanger fin and blocked the evaporation water flow to drain pan. The water will drop on tangential fan and cause water splashing out from indoor unit.
– 4 –
PRODUCT PERFORMANCE AND TECHNICAL PARAMETERS
Fuzzy control
High performance rotary
compressor
Low noise air intake system
Temperature sensing automatic
dehumidification
Sleep mode with automatic
adjustable temperature controls
High performance timer
Remote control swing mode
Automatic parking air vent grilles
Automatic fan speed adjustment
Left right drain hoses
Automatic functions
Detachable dust filter screen
High sensing thermostat
Unit body with well designed
curves
3 minute delay circuitry
3 fan speed selection
Flared piping joints
Instant dehumidifying functions
High performance cooling
functions
Fuzzy control
The common timer controls will always switch on the air conditioner at a predetermined time that could cause over cooling, however, with this advanced fuzzy control system the air conditioner will be either switched on before preset time or delayed depending on the indoor temperature changes, allowing the room temperature to reach the preset temperature within an optimal time frame, as such it will create an optimal air conditioned environment and will also provide greater savings on electrical energy consumption
Low noise air intake system
This newly modified low noise air intake system allows better and smoother air flows that will provide a quiet and refreshing environment
Sleep mode with automatic adjustable temperature controls
After adjusting the sleep mode timer before sleep, the temperature will be automatically controlled and adjusted accordingly to the lowering or body temperature during sleep and lower temperature throughout the night, to provide a conducive environment for a good sleep.
An hour after setting the sleep mode timer, the air conditioner will automatically adjust the optimal temperature; during summer it will be adjusted to 2°C higher than the preset room temperature, and the timer can be set at a 1-hour, 2-hour, 3-hour and 7-hour cycle. All can be set by pressing the control buttons that save you the trouble to pre-set the required operating modes before sleep
Temperature sensing automatic dehumidification
Hitachi air conditioners are specially equipped with précised and reliable temperature sensing automatic dehumidification function, that automatically operates the dehumidification whenever the room temperature exceeds the preset temperature and it stops whenever the room temperature falls back within the preset temperature as such it stabilizes the temperature and provides a more conducive environment for the user
Well designed unit body
The indoor unit incorporates the latest design and has a non-bulky body that measures 815 X 298 X 208 cm
Fuzzy control
Quiet
– 5 –
ENGLISH
Air filter
To prevent dust from coming into the indoor unit. (Refer page 17)
Front panel (Air inlet)
Indoor unit indicators
Light indicator showing the operating condition. (Refer page 6)
Horizontal deflector
Vertical deflector
(Air Outlet)
(Refer page 13)
Remote controller
Send out operation signal to the indoor unit. So as to operate the whole unit. (Refer page 7)
OUTDOOR UNIT
Drain pipe
Condensed water drain to outside.
Connecting cord
Air inlet (Back, Left side)
Air outlet
WIDTH (mm)
815
700
MODEL
RAS-10C9G, RAS-13C9G
RAC-10C9G, RAC-13C9G
HEIGHT (mm)
298
570
DEPTH (mm)
208
210
MODEL NAME AND DIMENSIONS
INDOOR UNIT
NAMES AND FUNCTIONS OF EACH PART
– 6 –
ATTACHING AND REMOVING FRONT PANEL
RECEIVABLE INDICATOR FUNCTIONS
While gripping both the left and right hand edges
[recessed in the front housing] of the front panel, lift up to open the front panel.
After completion of job, slightly lift up the front
panel and pull down to close the front panel. Ensure that the 3 sets of left, centre and right clips are fully secured.
Signal Receivable Window
Timer Lamp
This lamp lights when the timer is working.
Operation Lamp
This lamp lights during operation.
Filter Lamp
When the device is operated for a total of about 100 hours, the FILTER lamp lights to indicate that it is time to clean the filter. The lamp goes out when the POWER SWITCH set to OFF and ON again.
OPERATION INDICATOR
TEMPORARY SWITCH
When the remote control device is not functioning, use the Temporary Switch mode
(1) When the Temporary Switch is pressed, the unit will
operate as per the previous setting. Should there be a discontinuation of power supply the unit will operate as per its automatic setting.
(2) Press the Temporary Switch a second time will stop
the operations of the air conditioner unit
AUTO RESTART FUNCTION
In the event of power failure, the air conditioner will restart automatically.
In the event of power failure during TIMER operation, the timer will be reset and the unit will begin or stop operating under a new timer setting.
Temporary Switch On/Off Switch
– 7 –
ENGLISH
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
REMOTE CONTROLLER
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
Transmission sign
The transmission sign blinks when a signal is sent.
Display
This indicates the room temperature selected, current time, timer status, function and intensity of circulation selected.
CIRCULATION button
Use this button to set air circulation in the room or start operation.
DEHUMIDIFYING button
Use this button to reduce water quantity in the room or start operation.
COOLING button
Use this button to set cooling mode in the room or start operation.
RESET button
STOP button
Press this button to stop operation only.
SLEEP button
Use this button to set the sleep timer.
FAN SPEED selector
This determines the fan speed. Every time you press this button, the intensity of circulation will change from (AUTO) to (HI) to (MED) to (LOW) (during the (FAN) mode, from HI to MED to LOW).
AUTO SWING button
Controls the angle of the horizontal air deflector and to turn off filter lamp.
TEMPERATURE button
Use this button to raise or lower the temperature setting. (Keep pressed, and the value will change more quickly.)
OFF-TIMER button Select the turn OFF time.
ON-TIMER button Select the turn ON time.
Precautions for Use
Do not put the remote controller in the following places.
In direct sunlight.
In the vicinity of a heater.
Handle the remote controller carefully. Do not drop it on the floor, and protect it from water.
Once the outdoor unit stops, it will not restart for about 3 minutes (unless you turn the power switch off and on or unplug the power cord and plug it in again). This is to protect the device and does not indicate a failure.
If you press the FUNCTION selector button during operation, the device may stop for about 3 minutes for protection.
CIRCULATION / START
DEHUMIDIFY / START
COOLING / START
FAN
FAN SPEED LOW MED HI
SLEEP TIMER
STOP
TIMER SELECTOR ON TIMER OFF TIMER
AUTO SWING
8
˚
C
COOLING OPERATION
Use the device for cooling when the outdoor temperature is 21-43°C. If humidity is very high (over 80°C) indoors, some dew may form on the air outlet grille of the indoor unit.
Press the button so that the display indicates
(COOL).
Set the desired FAN SPEED with the
(FAN SPEED) button
(the display indicates the setting).
(AUTO): The FAN SPEED is HI at first and varies to
MED or LOW automatically when the preset temperature has been reached.
(HI) : Economical as the room will become cool
quickly.
(MED) : Fan speed slow.
(LOW) : Fan speed slower.
Set the desired room temperature with the TEMPERATURE button (the display indicates the setting).
The range of 25-28°C is recommended as the room temperature for cooling. If the temperature setting is 27°C, the room temperature will be controlled at around 27°C.
The temperature setting and the actual room temperature may vary somewhat depending on conditions.
Press the
(COOLING) button. Cooling operation starts with
a beep. Press the
(STOP) button to stop operation. The
cooling function does not start if the temperature setting is higher than the current room temperature (even though the
(OPERATION) lamp lights). The cooling function will start as soon as you set the temperature below the current room temperature.
As the settings are stored in memory in the remote controller, you
only have to press the
(COOLING) button next time.
1
2
STOP
3
9
ENGLISH
DEHUMIDIFYING OPERATION
Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work.
Dehumidifying Function
When the room temperature is higher than the temperature setting: The device will dehumidify the room, reducing the room temperature to the preset level. When the room temperature is lower than the temperature setting: Dehumidifying will be performed at the temperature setting slightly lower than the current room temperature, regardless of the temperature setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature becomes lower than the setting temperature.
As the settings are stored in memory in the remote controller, you only
have to press the
(DEHUMIDIFY) button next time.
Set the desired room temperature with the TEMPERATURE button (the display indicates the setting).
The range of 20-26˚C is recommended as the room temperature for dehumidifying.
2
Press the (DEHUMIDIFY) button. The FAN SPEED is set at LOW automatically.
The FAN SPEED button does not work.
1
Press the (DEHUMIDIFY). Dehumidifying operation starts with a beep. Press the
(STOP) button to stop operation.
˚
C
STOP
10
CIRCULATION OPERATION
Press the button so that the display indicates (CIRCULATE)..
Press the FAN SPEED button and select the desired FAN SPEED (the display indicates your choice).
Press the temperature control button to set to the desired temperature.
As the settings are stored in memory in the remote controller,
you only have to press the
(CIRCULATION) button next time.
2
1
3
Press the (CIRCULATION) button. Circulating operation starts with a beep. Press the
(STOP) button to stop
operation.
STOP
11
ENGLISH
HOW TO SET THE SLEEP TIMER
Press the (SLEEP) button, and the display changes as shown below.
Mode
Sleep timer
Indication
1 hour 2 hours 3 hours 7 hours
Sleep timer off
44 44
1
Sleep Timer: The device will continue working for the designated number of hours and then turn off. Point the signal window of the remote controller toward the indoor unit, and press the SLEEP button. The timer information will be displayed on the remote controller. The TIMER lamp lights with a beep from the indoor unit. When the sleep timer has been set, the display indicates the turn-off time.
Cooling
and
dehumidifying
Explanation of the sleep timer
The device will control the FAN SPEED and room temperature automatically so as to be quiet and good for people’s health. You can set the sleep timer to turn off after 1, 2, 3 or 7 hours. The FAN SPEED and room temperature will be controlled as shown below.
Function Operation
The settings of room temperature and circulation are varied.
The room temperature will be controlled 2°C above the setting temperature and the FAN SPEED will be set to LOW setting 60 minutes after the setting of the sleep timer.
Fan
Operation with the sleep timer
Sleep timer set
60 minutes later
3 hours later
7 hours later
2 hours later
SLEEP
12
HOW TO SET THE TIMER
ON Timer and OFF Timer are available.
OFF TIME setting
Select the OFF TIME by pressing the (OFF) Button.
Setting time will change according to the below sequence
when you press the button.
OFF Timer Reservation
Operation stop at setting time
1 2 3 9 10 11 12
1 hour interval
ON TIME setting
Select the ON TIMER by pressing the (ON)
Button.
Setting time will change according to the below
sequence.
ON Timer Reservation
1 2 3 9 10 11 12
1 hour interval
Operation will start for setting temperature at setting time (The starting time may different depend on the room temperature and set temperature).
Loading...
+ 28 hidden pages