Hitachi RA-08JF2, RA-10JF2 Operation And Installtion Manual

RA08/10JF2-EN 29/09/2006, 10:03 am1
– 1 –
SAFETY PRECAUTION
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
Please keep this manual after reading.
PRECAUTIONS DURING INSTALLATION
Please ask your sales agent or qualified technician for the installation of your unit. Water
WARNING
CAUTION
WARNING
leakage, short circuit or fire may occur if you install the unit yourself.
Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor or the earth line of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
Do not install near location where there is flammable gas. The unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose. (For drain model)
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
Should abnormal situation arises (like burning smell), please stop operating the unit and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock and fire.
Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air flow for your health.
Do not put objects like thin rods into the panel of blower and suction side because the high-speed fan inside may cause danger.
Do not use any conductor as fuse wire, this could cause fatal accident.
During thunder storm, disconnect and turn off the circuit breaker.
The product shall be operated under the manufacturer specification and not for any other intended use.
Do not attempt to operate the unit with wet hands, this could cause fatal accident.
When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
W
A
Please ensure that unit mounting frame is always stable, firm and without defect. If not, the unit may collapse and
R
cause danger.
N
I
Do not place plants directly under the air flow as it is bad for the plants.
N G
Turn off the circuit breaker if the unit is not be operated for a long period.
Do not put water container (like vase) on the unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and causes short circuit.
When operating the unit with the door and windows opened, and with the air deflector facing down for a long period of time, water will condensed on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
If the amount of heat in the room is above the cooling capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit.
Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause danger.
Do not climb on the unit or put objects on it.
RA08/10JF2-EN 29/09/2006, 10:03 am2
– 2 –
PARTS IDENTIFICATION AND OPERATIONS
CONTROL PANEL
OPERATION MODE SELECTOR DIAL
AUTO SWING
1
2
1 Cabinet 2 Suction Grille
3
3 Horizontal Deflectors
4 5
4 Vertical Deflector 5 Air Exhaust Lever 6 Front Cover
76
Model Width Height Depth
RA-08JF2
QUIET COOL
181/2", 470mm 139/16", 345mm 237/20", 610mm
OFF
HI FAN
HI COOL
TEMPERATUREMAIN SWITCH
9
8
10
COOLER
7
6
5
TEST
4
1
2
3
RA-10JF2
CAUTION
BEFORE
RESTARTING
ON
OFF
WAIT 3 MINUTES
AUTO SWING
QUIET FAN
7 Switch Panel Cover
1 Auto Swing Switch 2 Operation Mode Selector Dial 3 Thermostat Dial
123
When the AUTO SWING switch is turned to “ON” position, the vertical deflectors automatically
oscillate right and left sweeping the cold air alternately to obtain comfortable cooling.
The vertical deflectors may be stopped at any position when the AUTO SWING switch is
turned “OFF”.
OFF Stop the fan and cooling operation.
QUIET FAN The air conditioner will perform fan operation only at low speed.
HI FAN The air conditioner will perform fan operation only at high speed.
QUIET COOL Cooling operation with low fan speed. This is recommended for sleeping comfort.
HI COOL Cooling operation with high fan speed for maximum cooling power.
The starting operation will occur an abnormal sound (turbo sound) which doesn’t affect the
operation.
– 3 –
RA08/10JF2-EN 29/09/2006, 10:03 am3
Setting the desired room temperature. Turn the dial further clockwise for cooler indoor temperature.
AIR DEFLECTORS
VERTICAL DEFLECTORS
HORIZONTAL DEFLECTORS
THERMOSTAT DIAL
CAUTIONS
The compressor operates continuously by setting the temperature dial to “TEST”. This setting is used for technician. If the unit is operated at this position, the heat exchanger may freeze and causing water leakage or other malfunction. Do not set to “TEST” for normal usage.
When the compressor stops by turning the temperature dial counterclockwise in cooling operation, wait 3 minutes before turning it clockwise to restart it.
Vertical deflectors at both sides of outlets can be set to either auto-swing or static position to direct discharge air rightward, leftward or forward direction.
Vertical
Vertical Deflector
CAUTION
To avoid dew forming on the deflectors which eventually may drip to the floor, please do not adjust horizontal deflectors extremely downward position or vertical deflectors extremely leftward or rightward position during cool operation for a long time. Also, do not adjust the vertical deflectors position by hand or any other object.
Deflector
Horizontal deflectors at both sides of the outlets can be set to direct discharge air upward, downward or forward direction.
Horizontal
Horizontal Deflectors
Deflectors
AIR EXHAUST LEVER
Set the air exhaust lever to the OPEN (pull) position for air ventilation in the room. The air exhaust lever should normally be kept in CLOSE (push inward) position during cooling operation and in the case of typhoon.
Air Exhaust Lever
RA08/10JF2-EN 29/09/2006, 10:03 am4
– 4 –
AIR CLEANING FILTER
ALWAYS STOP THE OPERATION BEFORE INSTALLING THE AIR CLEANING FILTER.
1. Open the suction grille
2. Remove the normal filter
Air Cleaning Filter
3. Install the air cleaning filter in the frame
4. Install back the normal filter and close the suction grille
Hook
AIR CLEANING FILTER IS WASHABLE AND REUSABLE UP TO 20 TIMES BY USING VACUUM CLEANER OR RINSE WITH RUNNING TAP WATER.
AIR CLEANING FILTER SHOULD BE CLEANED EVERY MONTH OR SOONER IF NOTICEABLE LOADING OCCURS. WHEN USE OVERTIME, IT MAY LOSE ITS DEODORIZING FUNCTION.
FOR MAXIMUM PERFORMANCE, IT IS RECOMMENDED TO REPLACE IT EVERY 3-6 MONTHS DEPENDING ON APPLICATION REQUIREMENT.
TYPE NUMBER FOR THIS AIR CLEANING FILTER IS <SPX-CFH8W>, PLEASE USE THIS NUMBER FOR ORDERING WHEN YOU WANT TO RENEW IT.
NOTES ON OPERATION
TEMPERATURE AND HUMIDITY
Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). Recommended operation humidity should be below 80%. Continuous long operation at over 80% humidity (indoor) will cause some dews form on the outlet grille of the unit.
NOISE
In a quiet environment or stopping and starting operation, phenomena like flowing noise of refrigerant in the refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is normal for the operation. Water will condense on the evaporator coil and collected in the bottom tray, it is picked up by the condenser fan and blown onto the condenser coil, this creates a “splashing” noise which is normal.
ODOR
The odor will possibly be emitted from the room air conditioner especially at the starting of operation and in a high humidity condition. This is not abnormal phenomena because of the various kind of odors emitted by smoke, food stuffs, cosmetics and others which may stick to the room air conditioner. So, please clean the air filter and evaporator at the beginning of long no operation period to reduce the odor.
RA08/10JF2-EN 29/09/2006, 10:03 am5
– 5 –
THE IDEAL WAYS OF OPERATION
Suitable Room Temperature
FOR USER’S INFORMATION
Install Curtain or Blinds
Ventilation
Warning
Freezing temperature is bad for health and a waste of electric power.
Do Not Forget To Clean The Air Filter
Please Adjust Suitable Temperature
It is possible to reduce heat entering the room through windows.
For Baby And Children
Dusty air filter will reduce the air volume and the cooling efficiency. To prevent from wasting electric energy, please clean the filter every 2 weeks.
Please pay attention to the room temperature and air flow direction when operating the unit for baby, children and old folks who have difficulty in movement.
The Air Conditioner And The Heat Source In The Room
Caution
If the amount of heat in the room is above the cooling capability of the air conditioner (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
Caution
Do not close the room for a long period of time. Occasionally open the door and windows to allow the entrance of fresh air.
Warning
To protect the whole unit during lightning, please stop operating the unit and remove the plug from the socket.
RA08/10JF2-EN 29/09/2006, 10:03 am6
When Lightning Occurs
– 6 –
MAINTENANCE
CAUTION
ALWAYS TURN OFF AND UNPLUG BEFORE ANY CLEANING OR MAINTENANCE TO ENSURE SAFETY.
AIR FILTER
If the air filter is clogged with dust, the air flow volume will decrease and resulting in poor cooling performance, and increased operating noise. Be sure to clean the filter about every 20 days.
1 Remove the suction grille by pulling at both
bottom corner and then lift it up slightly before pull downward to unhook the suction grille.
2 Lift and unhook the bottom of the air filter and
remove it.
SUCTION GRILLE
3 Remove dust from the filter by using a vacuum
cleaner. If the filter is very dirty, wash it with detergent and rinse properly with water. Dry it with soft cloth and do not expose it to heat or under direct sunlight.
4 Install the filter by fitting the top hooks and then
hook the bottom of the filter.
5 Attach the suction grille back to its place by
hooking at the top side to the front cover, then gently push at both bottom corner.
CAUTION
Do not use hot water above 40°C for cleaning the filter.
Do not operate the air conditioner with the filter removed.
HOOK
RA08/10JF2-EN 29/09/2006, 10:03 am7
– 7 –
FRONT COVER AND SUCTION GRILLE
Clean the front cover and suction grille with a soft dry cloth. When it is excessively dirty, wipe it with a soft cloth dampened with mild soap, then wipe it again thoroughly with a soft dry cloth.
The suction grille can also be removed and be washed with water and mild soap. Remove the suction grille in the following manner.
1 Pull the suction grille at both bottom
corner and released it.
2 Lift up the suction grille slightly.
3 Remove the suction grille by pulling
downward to release it from the hook hole located at the top side.
CAUTION
Never use hot water above 50°C, erosive chemicals or brush to clean the front cover and suction grille because they will damage the plastic surface.
BEFORE ASKING FOR SERVICE
Check the following items before asking for service. If the malfunction persists, please contact service centre.
Symptom Cause
Does not operate 1 Is the power cord loosened or unplugged? at all 2 Is the fuse blown out or the circuit breaker tripped?
3 Is the voltage normal? 4 Is the main switch set to “OFF” position?
Poor cooling 1 Is the air filter covered with heavy dust? performance Clean the filter and replace it.
2 Is the temperature setting correctly? 3 Is the sunlight fall directly in the air conditioner? 4 Is the air flow on the rear side (outdoor) blocked?
Leave a space of 900 mm (3 feet) behind the rear side of air conditioner.
5 The doors or windows may be opened widely or there are
other sources of heat in the room.
6 Is the ventilation damper opened?
CAUTIONS
IF THE POWER SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE ONE SPECIALLY PREPARED AND ONLY AVAILABLE FROM THE MANUFACTURER OR ITS SERVICE AGENT.
RA08/10JF2-EN 29/09/2006, 10:03 am8
– 8 –