Hitachi KP-F145WCL, KP-F500WCL, KP-FR500WCL Operation Manual

Page 1
High pixel CCD camera
KP-F145WCL
Operation Manual
Hitachi Kokusai Electric Inc.
The second edition in August, 2012.
These products comply with the requirement of the RoHS (Restriction of the use of Certain Hazardous Substances in Electrical and electronic Equipment) Directive 2002/95/EC.
Thank you for purchase this fine Hitachi Kokusai Electric CCD camera. Before using the camera, please read this operation manual carefully.
Page 2
A
IMPORTANT SAFETY INSTRUCTIONS
1. Read Instructions
All the safety and operating instructions should be read before the product is operated.
2. Retain Instructions
The safety and operating instructions should be retained for future reference.
3. Heed Warnings
All warnings on the product and the operating instructions should be adhered to.
4. Follow Instructions
All operating and use instructions should be followed.
5. Cleaning
Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
6. Attachments
Do not use attachments not recommended by the product manufacturer as they may cause hazards.
7. Water and Moisture
Do not use this product near water - for example, near a bath tub, wash bowl, kitchen sink, or laundry tub; in a wet basement; or near a swimming pool; and the like.
8. Accessories
Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, causing serious injury to a child or adult, and serious damage to the product. Use only with a cart, stand, tripod, bracket, or table recommended by the manufacturer, or sold with the product. Any mounting of the product should follow the manufacturer's instructions, and should use a mounting accessory recommended by the manufacturer.
9. Moving
A product and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the product and cart combination to overturn.
10. Ventilation
Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating, and these
openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer's instructions have been adhered to.
11. Power Sources
This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your product dealer or local power company. For products intended to operate from battery power, or other sources, refer to the operating instructions.
12. Grounding or Polarization
This product is equipped with a three-wire grounding-type plug a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type plug.
13. Power-Cord Protection
Power-supply cords should be routed to that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plug, convenience receptacles, and the point where they exit from the product.
14. Lightning
For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the product due to lightning and power-line surges.
15. Overloading
Do not overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock.
16. Object and Liquid Entry
Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product.
17. Inflammable and Explosive Substance
Avoid using this product where there are gases, and also where there are inflammable and explosive substances in the immediate vicinity.
18. Heavy Shock or Vibration
When carrying this product around, do not subject the product to heavy shock or vibration.
19. Servicing
Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
20. Damage Requiring Service
Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: a. When the power-supply cord or plug is damaged. b. If liquid has been spilled, or objects have fallen into the product. c. If the product has been exposed to rain or water. d. If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions
as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to
its normal operation. e. If the product has been dropped or damaged in any way. f. When the product exhibits a distinct change in performance-this indicates a need for service.
21. Replacement Parts
When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards.
22. Safety Check
Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to determine that the product is in proper operating condition.
23. Wall or Ceiling Mounting
The product should be mounted to a wall or ceiling only as recommended by the manufacturer.
24. Heat
The product should be situated away from heat sources such as radiators, heat registers, stoves, or other products (including amplifiers) that produce heat.
Page 3
B
1. Alle Anweisungen lesen
Vor Betrieb des Erzeugnisses sollten alle Sicherheits-und Bedienungsanleitungen gelesen werden.
2. Die Anweisungen aufbewahren
Die Sicherheits-und Bedienungsanleitungen sollten fünftigen Bezug aufbewahrt werden.
3. Warnungen beachten
Die Warnungen auf dem Erzeugnis und in den Bedienungsanleitungen solten beachtet werden.
4. Anweisungen befolgen
Alle Bedienungsanleitung-und Verwendungsanweisungen sollten befolgt werden.
5. Reinigung
Den Stecker des Geräts vor Reinigung aus der Steckdose ziehen. Keine flüssigen Reinigungsmittel oder Aerosolreiniger verwenden. Zum Reinigen einen feuchten Lappen verwenden.
6. Zubehör
Nur vom-Hersteller des Erzeugnisses empfohlenes Zubehör verwenden, da es sonst zu Störungen kommen kann.
7. Wasser und Feuchtigkeit
Dieses Erzeugnis nicht in der Nähe von Wasser verwenden - z.B, in der Nähe einer Badewanne, eines Waschbeckens, einer Küchenspüle, eines Waschzubers, in einem nassen Keller, in der Nähe eines Schwimmbeckens usw.
8. Aufstellung
Das Erzeugnis nicht auf einen unstabilen Wagen, Stand, Dreifuß, Träger oder Tisch stellen.Das Erzeugnis kann sonst herunterfallen und ein kind oder einen Erwachsenen schwer verietzen.Außerdem kann das Gerät schwer beschädigt werden. Nur mit einem Wagen, Stand, Dreifuß, Träger oder Tisch verwenden, der vom Hersteller empfohlen oder mit dem Erzeugnis verkauft worden ist. Für jegliche Anbringung sollten die Anweisungen des Herstellers befolgt werden, und das vom Hersteller empfohlene Anbringungszubehör sollte verwendet werden.
9. Eine Kombination von Erzeugnis und Wagen sollte vorsichtig bewegt werden
Schneller Halt, übermäßige Krafteinwirkung und unebene Oberflächen können Umkippen der kombination von Erzeugnis und Wagen verursachen.
10. Ventilation
Schlitze und Öffnungen im Gehäuse dienen der Ventilation. Sie sind für zuverlässigen Betrieb des Gerätes und Schutz vor Überhitzung erforderlich und dürfen nicht blockiert oder abgedeckt werden. Die Öffnungen sollten niemals dadurch blockiert werden, daß, das Gerät auf ein Bett, ein Sofa, einen Teppich oder eine ähnliche Oberfläche gestellt wird.
Das Gerät sollte nur dann in Einbauinstallierung wie in einem Bücherschrank oder einem Gestell verwendet werden, wenn angemessene Ventilation vorgesehen ist bzw. Die Anweisungen des Herstellers befolgt worden sind.
11. Stromversorgung
Dieses Erzeugnis sollte nur an der auf dem Typenschild angegebenen Stromversorgungsart betrieben werden. Wenn Sie nicht sicher sind, was für eine Stromversorgung Sie haben, so wenden Sie sich bitte an Ihren Erzeugnishändler oder an das lokale Elektrizitätswerk. Beziehen Sie sich für Batteriebetrieb oder andere Stromquellen vorgesehene Erzeugnisse bitte auf die Bedienungsanleitungen.
12. Erdung oder Polarisierung
Dieses Erzeugnis ist mit einem Schutzkontaktstecker mit drei Leitern ausgerüstet, mit einem Erdungskontakt. Dieser Stecker paßt nur in ein schuko-Steckdose. Dies ist eine Sicherheitsmaßnahme. Wenn Sie den Stecker nicht in die Steckdose stecken können, so wenden Sie sich bitte an ihren Elektriker, damit er die veraltete Schuts des Schutzkontaktsteckers unwirksam.
13. Netzkabelschutz
Netzkabel sollten so verlegt werden, deß möglichst nicht darauf getreten wird und daß sie nicht eingeklemmt werden, mit besonderer Beachtung der kabel an Stackern, Verlängerungskabeln und dem Austritt des Kabels aus dem Erzeugnis.
14. Blitzschlag
Für zusätzlichen Schutz des Erzeugnisses während eines Gewitters oder bei Nichtverwendung für lange Zeit den Stecker aus der Steckdose ziehen. Dies verhütet Beschädigung durch Blitzschlag und Netzspannungsstöße.
15. Überlastung
Wandsteckdosen, Verlängerungskabel und eingebaute Bequemlickkeitssteckdosen nicht überlasten, da dies Feuer oder elektrischen Schlag verursachen kann.
16. Eindringen von Fremdkörpern und Flüssigkeit
Niemals Objekte irgendwelcher Art durch die Öffnungen in das Gerät schieben, da diese unter hoher Spannung stehende Teile berühren oder kurzschließen können, wodurch es zu Feuer oder elektrischem Schlag kommen kann. Niemals Flüssigkeiten irgendwelcher Art auf das Erzeugnis verschütten.
17. Entflammbare und explosive Substanzen
Vermeiden Sie Verwendung dieses Erzeugnisses an Orten mit Gasen bzw. entflammbaren oder explosiven Substanzen in der direkten Umgebung.
18. Starke stöße oder Vibrationen
Setzen Sie das Erzeugnis beim Transport nicht starken Stößen oder Vibrationen aus.
19. Wartung
Versuchen Sie nicht, dieses Erzeugnis Selbst zu warten, da Sie sich durch Öffnen bzw. Entfernen von Abdeckungen hohen Spannungen und sonstigen Gefährdungen ausserzen können. Beziehen Sie sich für jegliche Wartung auf qualifiziertes Wartungspersonal.
20. Beschädigung, die Wartung erfordert
Ziehen Sie den Stecker dieses Erzeugnisses aus der Steckdose und wenden Sie sich an qualifiziertes Wartungspersonal, wenn eine der folgenden Bedingungen vorliegt: a. Wenn das Netzkabel oder der Stecker beschädigt ist. b. Bei Eindringen von Flüssigkeit oder Fremdkörpern in das Gerät. c. Wenn das Erzeugnis Regen oder Wasser ausgesetzt worden ist. d. Wenn das Erzeugnis bei Befolgen der Bedienungsanleitungen nicht normal funktioniert.Nur die Regelelemente verstellen, die in den
Bedienungsanleitungen behandelt werden, da unangemessene Einstellung anderer Regelelemente Beschädigung verursachen kann und oft beträchtliche Arbeit durch einen qualifizierten Techniker erfordert, um das Erzeugnis wieder, zu normalem Betrieb zurückzubringen.
e. Wenn das Erzeugnis fallen gelassen oder beschädigt worden ist. f. Wenn das Erzeugnis eine klare Änderung in der Leistung zeigt-dies weist darauf hin, daß Wartung erforderlich ist.
21. Ersatzteile
Wenn Ersatzteile erforderlich sind, darauf achten, daß der Wartungstechniker nur die vom Hersteller festgelegten Ersatzteile oder Teile mit den gleichen Charakteristiken wie die ursprünglichen Teile verwendet. Unautorisierte Ersatzteile können Feuer, elektrischen Schlag oder sonstige Gefährdungen verursachen.
22. Sicherheitsprüfung
Bitten Sie den Wartungstechniker nach der Vollendung von Wartung oder Reparaturarbeiten an diesem Erzeugnis um die Durchführung von Sicherheitsprüfungen, um zu bestimmen, daß das Erzeugnis im angemissenen Betriebszustand ist.
23. Anbringung an der Wand oder an der Decke
Das Erzeugnis sollte nur entsprechend den Empfehlungen des Herstellers an einer Wand oder an der Decke angebracht werden.
24. Wärme
Das Erzeugnis sollte fern von Wärmequellen wie Radiatoren, Heizwiderständen, Öfen und anderen Wärme erzeugenden Erzeugnissen (einschließlich Verstärkern) aufgestellt werden.
WICHTIGE SICHERHEITSANWEISUNGEN
Page 4
C
MISES EN GARDE IMPORTANTES
1. Lire les instructions
Lire toutes les instructions de sécurité et de fonctionnement avant de faire fonctionner l’appareil.
2. Conserver ces instructions
Conserver les instructions de sécurité et de fonctionnement á des fins de référence ultérieure.
3. Tenir compte des avertissements
Tous les avertissements qui figurent sur l’appareil et dans le mode d’emploi devront être respectés.
4. Observer les instructions
Observer toutes les instructions de fonctionnement et d’utilisation.
5. Nettoyage
Avant de procéder au nettoyage, débrancher l’appareil de la prise secteur. Ne pas utiliser de produits de nettoyage liquides ou en aérosol.
Nettoyer l’appareil avec un chiffon humide.
6. Fixations
Ne pas utiliser de fixations non recommandées par le fabricant de l’appareil car elles pourraient être source de danger.
7. Eau et humidité
Ne pas utiliser l’appareil á proximité d’eau-ar exemple prés d’une baignoire, d’un lavabo, d’un évier ou d’un bac á lessive, dans un sous-sol humide, ou prés d’une piscine, etc.
8. Accessoires
Ne pas placer l’appareil sur un chariot, un socle, un pied, un support ou one table instables L’appareil pourrait tomber, blessant griévement des enfants ou des adultes, et étant sérieusement endommagé. Utiliser exclusivement le chariot, le socle, le pied, le support ou la table recommandés par le fabricant, ou vendus avec l’appareil. Pour tout montage de l’appareil, respecter les instructions du fabricant, et utiliser á cette fin l’accessoire de montage recommandé par le fabricant.
9. L’appareil monté sur son chariot devra être déplacé avec précaution
Des arrêts brusques, une force excessive et des surfaces irréguliéres pourraient provoquer le renversement de l’ensemble appareil-chariot.
10. Ventilation
Les fentes et les ouvertures du coffret sont prévues pour la ventilation ainsi que pour garantir un fonctionnement en toute sécurité de l’appareil et le protéger de toute surchauffe, et ces ouvertures ne devront donc être ni obstruées ni recouvertes. Ne jamais obstruer les ouvertures en placant l’apparei sur un lit, un sofa, un tapis ou toute surface similaire. Ne jamais placer l’appareil dans un support confiné, par exemple une bibliothéque ou une é tagé re, sans ventilation suffisante ou sans repecter les instructions du fabricant.
11. Sources d’allmentation
L’appareil devra être alimenté exclusivement sur le type d’alimentation indiqué sur l’étiquette signalétique. Sil’on n’est pas sûr du type d’alimentatio du local, consulter le revendeur de l’appareil ou la compagnie d’électricité locale. Pour les appareils qui fonctionnent sur batterie ou sur d’autres sources, voir le mode d’emploi.
12. Mise á la terre ou polarisation
L’appareil est doté d’une fiche trifilaire avec mise á la terre, dont la troisiéme broche assure la mise á la terre. Cette fiche ne rentrera que dans les prises trifilaires de mise á la terre. Ceci est une mesure de sécurité. Si la fiche ne rentre pas dans la prise, faire remplacer la prise désuéte par un électricien. Ne pas rendre vaine la measure de sécurité assurée par cette prise avec mise á la terre.
13. Protection du cordon d’alimentation
Acheminer les cordons d’alimentation de facon qu’on ne risque pas de marcher dessus ou de les coincer sous un objet placé dessus ou contre eux. Faire particuliérement attention aux fiches des cordons, á la proximité des prises, et á l’endroit oú ils ressortent de l’appareil.
14. Foudre
Pour renforcer la protection de l’appareil pendant un orage, ou si l’on s’en éloigne ou qu’on reste longtemps sans l’utiliser, le débrancher de la source d’alimentation. Ceci permettra d’éviter tout dommage de l’appareil dú á la foudre et aux surtensions de ligne.
15. Surcharge
Ne pas surcharger les prises, rallonges et prises multiples car cela pourrait entraîner un risque de feu ou de choc électrique.
16. Pénétration d’objets et de liquides
Ne jamais enfoncer d’objets d’aucune sorte dans les ouvertures de l’appareil car ils pourraient toucher des points de tension dangereuse ou court-circuiter des piéces, ce qui pourrait provoquer un feu ou un choc électrique. Ne jamais renverser de liquide d’aucune sorte sur l’appareil.
17. Substances inflammabes et explosives
Eviter d’utiliser l’appareil en présence de gaz, ainsi qu’á proximité immédiate de substances inflammables et explosives.
18. Chocs ou vibrations violents
Lorsqu’on transporte l’appareil, ne pas le soumettre á des chocs ou des vibrations violents.
19. Réparations
Ne pas tenter de réparer l’aapareil soi-même car le fait d’ouvrir ou de retirer les caches risque d’exposer l’utilisateur á des tensions dangereuses notamment. Confier toute réparation á un personnel qualifié.
20. Dommages nécessitant réparations
Débrancher l’appareil de la source d’alimentation et confier les réparations á un personnel qualifié dans les cas suivants: a. Lorsque le cordon d’alimentation ou sa fiche sont endommagés b. Si du liquide s’est renversé sur l’appareil ou que des objets sont tombés dedans c. Si l’appareil a été exposé á la pluie ou á l’eau. d. Si l’appareil ne fonctionne pas normalement lorsqu’on observe les instructions d’utilisation.
Ne régler que les commandes couvertes par le mode d’emploi ; en effet, un réglage incorrect des autres commandes pourrait entrainer des dommages
et nécessiteront souvent des travaux de réparation coûteux par un technicien qualifié pour remettre l’appareil en état de marche. e. Si l’appareil est tombé ou qu’il a été endommagé. f. Si l’appareil affiche une nette modification de ses performances, cela signifie qu’il a besoin d’être réparé.
21. Piéces de rechange
Si l’on a besoin de piéces de rechange, veiller á ce que le technicien de réparation utilise exclusivement les piéces de rechange spécifiées par le fabricant ou des piéces ayant les mêmes caractéristiques que les piéces d’origine. Les piéces de rechange non autorisées risquent de provoquer un feu, un choc électrique et autres dangers.
22. Vérificaton de sécurité
Aprés tout travail d’entretien ou de réparation de l’appareil, demander au technicien de réparation d’effectuer les vérifications de sécurité pour s’assurer que l’appareil est en bon état de marche.
23.Montage au mur ou au plafond
L’appareil ne pourra être monté au mur ou au plafond que de la maniére recommandée par le fabricant.
24. Chaleur
Eloigner l’appareil des sources de chaleur, telles que radiateurs, appareils de chauffage, cuisiniéres, et de tour produit engendrant de la chaleur (y compris les amplificateurs)
Page 5
D
The following statement is related to the regulation on “ Measures for the Administration of the control of Pollution by Electronic Information Products “ , known as “ China RoHS “. The table shows contained Hazardous Substances in this camera.
说明书(环境方面:补充资料)
对象产品CCD 摄像机
1.电子产品污染控制标志
此 标 志是 根据 2006 2 28 日 公 布的 《电 子信息 产 品污染 控 制管 理办法 》 以及
SJ/T11364-2006《电子信息产品污染控制标识要求》而制定的,是用来表示适用于在中华人民 共和国流通的电子信息产品的环保使用期限。
只要遵守此类产品的安全事项以及使用上应注意的问题,从制造日起到此年限内,不会发生产 品中的有害物质外泄、突变等,不会对环境、人体以及财产产生严重影响。同时,此年限是除去 必须定期交换的保守部品的,是其他产品的环保使用期限。
产品在正常情况下使用完毕要废弃时,请遵守各地区对电子信息产品的回收再利用的相关各项法律、法规。 另外,从第三者处转买的情况下即使在本期限内也视为失去效力。
2.产品中有毒有害物质或元素的名称及含量
有毒有害物质或元素
部件名称
(Pb)
水银
(Hg)
(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
主机 × ○ ○:表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T11363-2006 标准规定的限量要求以下。 ×:表示该有毒有害物质至少在该部件的某一均材料中的含量超出 SJ/T11363-2006 标准规定的限量要求。
IMPORTANT NOTICE
China RoHS
These products have been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this product in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WARNING Changes or modifications not expressly approved by Hitachi Denshi responsible for compliance could void the user’s authority to operate the equipment.
This product does not exceed the class A/class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations. Le présent appareil n’émet pas de bruits radioélectriques dépassant les limités applicable aux appareils numériques de classe A prescrites dans le rVglement sur le brouillage radioélectrique édicter par le ministére des communications du canada.
For U.S.A.
For Canada
Page 6
E
Page 7
F
Phenomena inherent to CCD imaging device
The following phenomena are inherent to a charge coupled device imaging element and do not indicate malfunction.
1) Smear and blooming
Vertical bands are visible when a strong light enters the scene. Adjust the camera aiming direction carefully to avoid strong direct or reflected light.
2) Fixed pattern noise High ambient temperature can cause fixed pattern noise to appear throughout the scene.
3) Moire Interaction between patterns can produce an additional "phantom" pattern to appear. The CCD picture elements (pixels) are arranged in a pattern, which can interact with a pattern in the scene (e.g., a performer wearing a finely striped necktie) to result in a Moire pattern. The effect should be considered when selecting costumes, props and other scene elements.
4) Ghosting Strong direct or reflected light near an object of interest can cause ghosting of the object to appear in the picture. The effect is more obtrusive with certain iris settings and lens types. Select the scene layout and camera pointing direction carefully in order to avoid this effect.
5White spot
Imperceptible white spots may rarely come up on the screen due to cosmic rays and so on. It becomes easy to appear when the sensitivity of the camera is raised in the operation at the high temperature.
Operating considerations Notes to users
1. Important safety notes
Use this camera with a 12VDC power supply, Observe that flammable objects, water or metal do not enter the camera interior. These may lead to failure or accident. Do not modify the camera or use the camera with external covers removed. These may cause failure, void any warranties and
pose a safety hazard.
Stop using the camera at the approach of electrical storm (thunder audible). Protect the camera from rain if using it outdoors. In event the camera shows any abnormality, switch off the camera and disconnect the power cord. Contract a Hitachi Denshi
service representative.
2. Handling
Do not attempt to remove cover. When installing or removing a lens, be sure to use care that water or dust dose not enter the inside of the camera.
3. Installing and storage
Avoid installing or storing the camera in the following environments.
Environments exposed to direct sunlight, rain or snow. Environments where combustible or corrosive gas exists. Excessively warm or cold environment (Operating ambient temperature: -10 to 50℃). Humid or dusty environment. Place subjected to excessive vibration or shock. Environment exposed to strong electric or magnetic field. Do not aim the camera lens at the sun. Do not shoot strong light.
When such a scene is shot, vertical trailing will appear. However, this is not due to failure. In case strong light enters camera through the lens, partial deterioration in picture quality will result.
4. To obtain stable performance for long time
When the camera is used continuously for long time under high ambient temperature, the inside electrical parts become deteriorated, resulting in shortening its life. To use the camera continuously for long time, the highest temperature must be below 40℃.
5. Connectors
Confirm the power is off before connecting or disconnecting a signal cable. Grasp connectors by the body, not the attached
wires.
6. Cleaning
Use a blower or a lens brush to remove dusts on the lens or the optical filter. Wipe dirts on the case off with dry soft cloth. If dirts are hardened, wipe them off with cloth moistened with neutral detergent
liquid; wipe the cover with dry cloth.
Do not use benzene, thinner, alcohol, liquid cleaner or spray-type cleaner. In event dust or other debris is lodged between the CCD and optical filter, consult dealer for cleaning by an optical technician.
7. Attention about laser light
Laser light may do damage to CCD. When you use laser light, be careful not to irradiate it on the CCD surface. The CCD
breakage by laser light irradiation is out of warranty. (The repair is not free of charge.)
Page 8
G
Table of Contents
1. Overview ··········································································································································· 1
2. Standard Composition ······················································································································· 1
3. Features ············································································································································ 1
4. System example ································································································································ 1
5. Section name and functions ·············································································································· 2
6. Camera mounting ······························································································································ 2
7. Lens ·················································································································································· 2
8. Optical filter ······································································································································· 3
9. Connector ········································································································································· 4
10. Functions and operations ·················································································································· 5
11. Remote control ·································································································································· 8
12. Command list ·································································································································· 15
13. CameraLink output timing chart ······································································································ 17
14. Trigger operation and timing chart ·································································································· 20
15. Input / Output signal ························································································································ 25
16. Spectral response ··························································································································· 26
17. Specifications ·································································································································· 27
18. Dimensions ····································································································································· 28
Page 9
1
Overview
KP-F145WCL are CameraLink output type black and white camera which utilized the 2/3 –inch progressive scan CCD
image sensor with square pixel. It provide images of unparalleled quality at 30 frame per second non-interlaced output. Because square pixel CCD is adopted, the image that is appropriate for the picture processing is obtained.
Standard composition
Check when unpacking Camera ··································································································· 1 Composition table ··············································································· 1
Features
・High resolution
The 2/3-inch 1,450,000 pixels square lattices CCD achieve a high resolution.
・Small and lightweight
The small SDR connector for digital output allows the camera size and mass to be drastically reduced to 44(W) x 44(H) x
41(D) mm / approx. 110g. ・Automatic power supply change
The power supply through the cameralink cable is possible from the PoCL frame grabber board. Because the power supply
from the DCIN/SYNC connector is also possible, it is possible to make the camera work by using usual frame grabber board.
The power supply from the DCIN/SYNC connector is given to priority when the power supply is supplied from both..
System example
KP-F145WCL connect to frame grabber board using CameraLink cable.
HITACHI
HITACHI
AC adaptor
Power over type CameraLink
frame grabber board
CameraLink
frame grabber board
Power over type
Mini-CameraLink cable
Mini-CameraLink cable
Optional accessories (1) 12 pin plug HR10A-10P-12S(01) (2) Junction box JU-F30/JC-100 (3) Dummy glass (AR coated) ARC1214 (4) IR cut filter IRC650 (5) Tripod adaptor TA-F500 (6) Mini-CameraLink cable
(7) Camera cable
Molded type
Shield type
2m C-201KSM
C-
201KSS
5m C-501KSM
C-
501KSS
10m C-102KSM
C-
102KSS
In the CE Marking region, use the shied type and install clamp filter (ZCAT 2035-0930A: TDK) at both ends (camera and video processor ends).
Page 10
2
Section name and functions
Camera mounting
Attached optional accessory the tripod adaptor "TA-F500", mount the camera to a tripod or mounting bracket.
Lens
CameraLink connectors Use for digital video output and camera control signal input/output signal. The power supply from the board is also possible.
Camera / Tripod adaptor
mounting screw holes
Lens mo
unt
(C mount)
DC IN/SYNC 12pin connector Use for DC+12V power and external trigger/VD signal input. When the board supplies the power supply by way of the CameraLink connector, the connection is unnecessary.
Camera / Tripod adaptor
mounting screw holes
CAUTION Observe the dimensions of the lens mounting selection as illustrated at the right. If the dimensions are not observed, do not use such a lens, because the lens and the camera will be damaged.
Lens flange
Lens optics
Max 9mm
Screw type: U1/4-20 Length L = 4 to 5.5mm Screws longer than 5.5 mm can cause internal damage, while less than 4 mm prevents secure fastening and risks dropping to cause damage and injury.
L
Page 11
3
Optical filter
How to remove the optical filter. (1) Remove two screws ① and filter holder ② will come off. (2) Remove the optical filter ③ from filter frame ④. (3) Then, reinstall and secure filter holder ② with two screws ①. Note: Prior to removing the optical filter, be sure to turn off the power. Since garbage etc. invades into image reception surface camera, please work under the clean air, such as a CLEAN ROOM.
1
2
3
4
Page 12
4
Connector
1. CameraLink connector D.OUT1 (Connector 1)
Pin No. Signal Pin No. Signal
+12V (PoCL)
1
GND (non-PoCL)
14 GND
2 TXOUT 0 (-) 15 TXOUT 0 (+) 3 TXOUT 1 (-) 16 TXOUT 1 (+) 4 TXOUT 2 (-) 17 TXOUT 2 (+) 5 TXCLKOUT (-) 18 TXCLKOUT (+) 6 TXOUT 3 (-) 19 TXOUT 3 (+) 7 RX (+) [ SERTC (+) ] 20 RX (-) [ SERTC (-) ] 8 TX (-) [ SERTFG (-) ] 21 TX (+) [ SERTFG (+) ]
9 TRIG-A/VD (-) [ CC1 (-) ] 22 TRIG-A/VD (+) [ CC1 (+) ] 10 N.U. [ CC2 (+) ] 23 N.U. [ CC2 (-) ] 11 N.U. [ CC3 (-) ] 24 N.U. [ CC3 (+) ] 12 N.U. [ CC4 (+) ] 25 N.U. [ CC4 (-) ]
+12V (PoCL)
13 GND 26
GND (non-PoCL)
SDR connector (3M) or equivalent N.U.: Not used
- The digital out cable should be comprised of a twisted pair of wires having 100Ω characteristic impedance and an outer heath shield type conductor.
- Connect the shield (ground) of the digital out cable to the ground terminal of the video equipment, frame grabber, etc.
- TX: Transmit data from camera to machine
- RX: Transmit data from machine to camera
(Note) Please do not unplug and insert cable (digital out cable) with a power supplied to a camera.
2. DCIN/SYNC connector PIN NO. Signal PIN NO. Signal
1 GND 7 Trigger IN / VD IN
---- (PoCL)
2
+12V (non-PoCL)
8 GND
3 GND 9 ---­4 ---- 10 FLASH OUT / VD OUT 5 GND 11 ---­6 ---- 12 GND
Connector (camera side) : SNH-10-12(RPCB) SAMWOO or equivalent
Plug (matching cable plug) : HR10A-10P-12S(01) HIROSE or equivalent
Page 13
5
Functions and operations
Various mode setup and adjustment of KP-F145WCL are performed by the remote control via CameraLink. Operation and adjustment way of function utilized are described below. See "Remote control" and "Command list" (page 8 to 16) about communication method of each command.
1. Main functions
(1) TRIGGER : Setting about external trigger
・MODE : Select of mode OFF (Factory setting) : Trigger mode set to OFF (normal mode). FIXED SHUTTER : Set to Fixed shutter mode. ONE TRIGGER : Set to ONE trigger mode. VD CONTROL : Set to VD reset mode. ・POLARITY : Select of trigger polarity POSITIVE (Factory setting) : Input polarity HIGH is made into trigger signal. NEGATIVE : Input polarity LOW is made into trigger signal. ・SOURCE : Select of trigger source CL-CC1 (Factory setting) : Input trigger signal from CameraLink signal CC1 (see page 4 "Connector"). 12pin : Input trigger signal from 7 pin of 12 pin DCIN/SYNC connector. * See "Trigger operation and timing chart" (page 20 to 24).
(2) OUTPUT SIGNAL : Setting of the tenth pin of DCIN/SYNC connector
OFF (Factory setting) : No output. FLASH OUT : Output flash pulse (strobe out). VD OUT : Output camera VD.
(3) SHUTTER : Setting of electronic shutter
OFF (Factory setting) : Shutter operation set to OFF (normal shutter). 1/30, 1/60, 1/100, 1/250, 1/1000, 1/2000, 1/10000, 1/50000 second : Set to setting shutter speed (PRESET shutter). VARIABLE : Set to shutter speed from 10 second to 1/100000 second (VARIABLE shutter).
-VARIABLE VALUE- : Setting speed of VARIABLE shutter. 10 to 1/100000 second : Electronic shutter can be set in the range of 10 to 1/100,000 second in 1536 steps.
Shutter speed setting value and exposure time can be derived as follows. (
ShutterSpeed
:: μsecond)
a) Setting value XYY16 obtained from exposure time.
 
 
 
 
9
100
1
10
1
16
1X
YY
X
edShutterSpe
edShutterSpe
int
))int(log(
b) Exposure time obtained from setting value XYY16.
sec])[(
9110
1
16
16
X
100
YY
edShutterSpe
Page 14
6
Ex.1 Exposure time = setting value XYY16 to obtain 1/125 second (= 8000μsecond).

16
16
16
16
12
2C7XYY
C7
9
100
7
9
100
1
10
8000
YY
2
18000X
 
 
 
 
 
 
    int
int
logint
Ex.2 Setting value 25D16 that produces 1/234.22 second exposure time.
[sec]
sec][
)(
234.22
1
4269.53
9
100
5D
110
16
16
2
1
edShutterSpe
(4) DATA BIT : Setting of output bit depth
8bit (Factory setting) : Image is outputted by 8 bit. 10bit : Image is outputted by 10 bit. 12bit : Image is outputted by 12 bit.
(5) VD/FVAL : Setting of vertical sync signal
VD : Output VD. FVAL (Factory setting) : Output FVAL.
(6) HD/LVAL : Setting of horizontal sync signal
HD : Output HD. LVAL (Factory setting) : Output LVAL.
(7) GAIN : Setting of electrical sensitivity
0 (Factory setting) to 18dB : Set from 0 to 18dB in 504 steps.
(8) BLACK LEVEL : Adjust offset level
0 (Factory setting) to 63 : Set in 64 steps.
(9) VERTICAL 2 PIXEL ADDITION : Setting of vertical two pixel addition
OFF (Factory setting) : Not perform vertical two pixel addition. ON : Perform vertical two pixels addition and frame rate is increased about 2 times.
(10) PARTIAL SCAN : Setting about partial scan
-MODE- : Select of mode OFF (Factory setting) : Not perform partial scan. ON : Perform partial scan.
-START- : Start position of partial scan 1 (Factory setting) to 1040: Scan is started from the line set up in 1 to 1040.
-WIDTH- : Width of partial scan 1 to 1040 (Factory setting): Scan is performed number of line set up in 1 to 1040 is scanned.
* When using partial scan, please make sum total of START and WIDH into 1041 or less. * When using partial scan, please use FVAL.
Page 15
7
(11) TEST PATTERN : Setting for the test pattern.
OFF (Factory setting) : Test pattern is OFF. H-LAMP : Output the horizontal lamp image. V-LAMP : Output the vertical lamp image. HV-LAMP : Output the horizontal and vertical lamp image.
(12) FACTORY SETTING
-SET- : Return to the factory settings.
Page 16
8
Remote control
1. Comms* specifications
・Control system : Start-stop synchronization system ・Transmission rate : 9600 bps ・Data length : 8 bit ・Star bit : 1 bit ・Stop bit : 1 bit ・Parity : None ・Bit transfer : LSB first *Comms: Communications
2. Comms control
The remote control software controls all communications. Data send/receive (BSC handshake) is by transferring TEXT data to the camera controller chip.
3. Comms procedure
The following pages indicate the camera controller chip and remote control software data protocol. In the description, the
camera is designated as slave and the software as master. ・Receive protect timer (time out error) The receive protect timer for master and slave processes is 1 second. For example, if 1 block of TEXT data is being
received, if the data interval exceeds 1 second, error is produced and the data are lost. An acknowledgment of data receipt is not produced.
Page 17
9
(1) Transmission from master (normal process)
① Session starts when ENQ is sent from master to slave. ② Slave acknowledges by returning ACK to master. ③ Master sends data to slave. ④ Slave acknowledges receipt of data by again returning ACK to master and end the handshake.
(2) Master reads data (normal process)
① Session starts when ENQ is sent from master to slave. ② Slave acknowledges by returning ACK to master. ③ Master sends read command to slave. ④ Slave receives read command, then acknowledges by returning ACK code to master. ⑤ Slave sends read data to master. ⑥ Master receives read data, then acknowledges by returning ACK code to slave.
Slave
(KP-F145WCL)
HITACHI
Master (Machine)
1
3
4
ENQ code (05H)
ACK code (06H)
ACK code (06H)
Transmit data (ASCII code)
HITACHI
Master (Machine)
1
2
3
4
ENQ code (05H)
ACK code (06H)
Read command (ASCII code)
ACK code (06H)
6 5
Read data (ASCII code)
ACK code (06H)
Slave
(KP-F145WCL)
Page 18
10
(3) Data transmitted by master (control abort process)
① Master sends ENQ code to slave. ② Since ACK code cannot be sent, slave sent NACK code to master. ③ Sequence is repeated 3 times in attempts to retransmit.
After receiving the 3rd successive NACK code, communications control is aborted
(4) Data transmitted by master (data error process)
① Session starts when ENQ is sent from master to slave. ② Slave acknowledges by returning ACK to master. ③ Master sends data, but slave detect error (framing, over-run error). ④ Slave detects error and does not accept data. ⑤ Sequence 3 and 4 repeats, then master transfers normal data. ⑥ Slave detects normal data and returns ACK code to master to end the session.
HITACHI
Master (Machine)
1 23
ENQ code (05H)
NACK code (15H)
ENQ code (05H)
NACK code (15H)
ENQ code (05H)
NACK code (15H)
ENQ code (05H)
NACK code (15H)
Slave
(KP-F145WCL)
HITACHI
Master (Machine)
1 2
3
ENQ code (05H)
ACK code (06H)
Send data (error occurs)
Send data (error occurs)
Send data (data normal)
ACK code (06H)
4 5 6
3 second
elapse
3 second
elapse
Slave
(KP-F145WCL)
Page 19
11
(5) Data frame error (Master transmission)
① Session starts when ENQ is sent from master to slave. ② Slave acknowledges by returning ACK to master. ③ Master sends data. ④ For some reason, slave does not receive data. ⑤ Master does not receive acknowledgment to the send code and repeats the sequence every 3
seconds for 3 times.
⑥ If unsuccessful after 3 attempts, master aborts the sequence and ends communication.
HITACHI
Master (Machine)
1 23
ENQ code (05H)
ACK code (06H)
Send data (ASCII code)
Send data (ASCII code)
Send data (ASCII code)
4
5
Send data (ASCII code)
6
3 second
elapse
3 second
elapse
3 second
elapse
Slave
(KP-F145WCL)
Page 20
12
(6) Transmission frame error (Master receive)
① Session starts when ENQ is sent from master to slave. ② Slave acknowledges by returning ACK to master. ③ Master sends read command. ④ Slave returns ACK code to acknowledge read command. ⑤ Slave sends read data to master. ⑥ For some reason, master fails to receive read data. ⑦ Slave fails to receive acknowledgment of read data and attempts to resend every 3 seconds for 3
times.
⑧ After the third failure, slave aborts the sequence and ends communication.
HITACHI
Master (Machine)
1 26
ENQ code (05H)
ACK code (06H)
Read data (ASCII code)
Read data (ASCII code)
Read data (ASCII code)
7
Read data (ASCII code)
8 3 4
Read command (ASCII code)
ACK code (06H)
5
3 second
elapse
3 second
elapse
3 second
elapse
Slave
(KP-F145WCL)
Page 21
13
4. Comms command data format
(1) Send data and read command (master to slave) (a) Command data are converted into ASCII code and transmitted. (b) Comms byte quantity is 18. (c) Comms data format (transmission sequence).
・STX (start code) : Code indicating start of text.
1 byte (02H) ・Text data : Transmit / receive data. 14 byte (ASCII code) ・ETX (end code) : Code indicating end of text. 1 byte (03H)
・SUM : XOR result (FFH), of adding STX, Text data, and ETX.
2 byte (ASCII code)
(d) Text data format details (transmission sequence).
・Status : Transmission data status.
2 byte (ASCII code)
Used for EEPROM write (0: write absent, 1: write present). ・ID No. : Camera peculiar ID.
KP-F145WCL have (FFH).
2 byte (ASCII code) ・Area address : Classification of Send data (01H) and Read command (81H).
2 byte (ASCII code) ・Relative No. : Sets number (0 to 255) for each adjustment item.
2 byte (ASCII code)
・Data (note) : Sets data to be transmitted.
2 byte x 3 (ASCII code)
S T X
1 byte
Text data
14 byte
E T X
1 byte
S U M 2 byte
18 byte
Status 2 byte
ID No.
2 byte
Area address
2 byte
Relative No.
2 byte
Data
2 byte x 3
14 byte
Page 22
14
(2) Read (receive) data (slave to master) (a) Command data are converted into ASCII code and transmitted. (b) Comms byte quantity is 10. (c) Comms data format (transmission sequence)
・STX (start code) : Code indicating start of text. 1 byte (02H) ・Text data : Transmit / receive data. 6 byte (ASCII code) ・ETX (end code) : Code indicating end of text. 1 byte (03H) ・SUM : XOR result (FFH), of adding STX, Text data, and ETX.
2 byte (ASCII code)
(d) Text data details (transmission sequence)
・Data (note) : Sets Read data to be transmitted. 2 byte x 3 (ASCII code)
Note: Data transfer sequence
Data bytes 1st byte 2nd byte 3rd byte
1 Data 0x00 0x00 2 Upper Lower 0x00 3 Upper Mid Lower
5. Calculation method of checksum
Example
1 2 3 4 5 6 7
STX
STATUS ID NO AREA ADDRESS RELATIVE NO
DATA
ETX SUM
02 01 FF 01 04 00 00 00 03 28
1. STAUTUS to DATA are transformed into hexadecimal number on the basis of the ASCII code.
'0'→(30)
16
'1'→(31)16 '4'→(34)16 'F'→(46)16 STX: (02)16 ETX: (03)16
2. STX to ETX are added all.
(02)16+(30)16+(31)16+(46)16+(46)16+(30)16+(31)16+(30)16+(34)16+(30)16+(30)16+(30)16+(30)16+(30)16+(30)16+(03)
16
=(2D7)
16
STX STATUS ID AREA RELATIVE DATA ETX
3. The XOR (Exclusive OR) between the value obtained in 2 clause and (FF)16 are taken, then two column under the
answer become SUM
(2D7)16 XOR (FF)16 = (228)16
S T X
1 byte
Text data
6 byte
E T X
1 byte
S U M 2 byte
10 byte
Data
2 byte x 3
6 byte
Page 23
15
1. Send data (Setting command. Note: 1 to 7 and SUM need to be transformed into ASCII code)
1 2 3 4 5 6 7
Item STX
STATUS ID NO.
AREA
ADDRESS
RELATIVE
NO.
DATA
ETX SUM
OFF 02
01 FF 01 04 00 00 00 03 28
FIXED 02
01 FF 01 04 01 00 00 03 27
1TRIG 02
01 FF 01 04 02 00 00 03 26
MODE
VD CONT 02
01 FF 01 04 04 00 00 03 24
POSITIVE 02
01 FF 01 0F 00 00 00 03 16
POLARITY
NEGATIVE 02
01 FF 01 0F 01 00 00 03 15
CL-CC1 02
01 FF 01 05 00 00 00 03 26
TRIGGER
SOURCE
12pin 02
01 FF 01 05 01 00 00 03 25
OFF 02
01 FF 01 06 00 00 00 03 26
FLASH OUT 02
01 FF 01 06 01 00 00 03 25
OUTPUT SIGNAL
VD 02
01 FF 01 06 02 00 00 03 24
OFF 02
01 FF 01 08 00 00 00 03 24
1/30 02
01 FF 01 08 01 00 00 03 23
1/60 02
01 FF 01 08 02 00 00 03 22
1/100 02
01 FF 01 08 03 00 00 03 21
1/250 02
01 FF 01 08 04 00 00 03 20
1/1000 02
01 FF 01 08 05 00 00 03 1F
1/2000 02
01 FF 01 08 06 00 00 03 1E
1/10000 02
01 FF 01 08 07 00 00 03 1D
1/50000 02
01 FF 01 08 08 00 00 03 1C
PRESET
VARIABLE (*2) 02
01 FF 01 08 FF 00 00 03 F8
MIN (1/100000(s)) 02
01 FF 01 11 00 (*3) 00 (*3) 00 03 2A
SHUTTER
SPEED
(*1)
VARIABLE VALUE
(2Byte) (*2)
MAX (10(s)) 02
01 FF 01 11 06 (*3) 00 (*3) 00 03 1E
8bit 02
01 FF 01 14 00 00 00 03 27
10bit 02
01 FF 01 14 01 00 00 03 26
DATA BIT
12bit 02
01 FF 01 14 02 00 00 03 25
VD 02
01 FF 01 15 00 00 00 03 26
VD/FVAL
FVAL 02
01 FF 01 15 01 00 00 03 25
HD 02
01 FF 01 16 00 00 00 03 25
HD/LVAL
LVAL 02
01 FF 01 16 01 00 00 03 24
MIN (-6dB:0) 02
01 FF 01 0C 00 00 00 03 19
(0dB:168) 02
01 FF 01 0C 00 A8 00 03 00
GAIN (2Byte)(*4)
MAX(18dB:671) 02
01 FF 01 0C 02 9F 00 03 F8
MIN (0) 02
01 FF 01 17 00 (*5) 00 00 03 24
BLACK LEVEL
MAX (63) 02
01 FF 01 17 3F (*5) 00 00 03 0B
OFF 02
01 FF 01 13 00 00 00 03 28 VERTICAL 2 PIXEL
ADDITION
ON 02
01 FF 01 13 01 00 00 03 27
OFF 02
01 FF 01 1E 00 00 00 03 16
MODE
ON (*6) 02
01 FF 01 1E 01 00 00 03 15
MIN (1) 02
01 FF 01 1F 00 01 00 03 14 START
(2BYTE) (*6)
MAX (1040) 02
01 FF 01 1F 04 (*7) 10 (*7) 00 03 10
MIN (1) 02
01 FF 01 20 00 01 00 03 29
PARTIAL
SCAN
WIDTH
(2BYTE) (*6)
MAX (1040) 02
01 FF 01 20 04 (*7) 10 (*7) 00 03 25
OFF 02
01 FF 01 50 00 00 00 03 27
H-LAMP 02
01 FF 01 50 01 00 00 03 26
V-LAMP 02
01 FF 01 50 02 00 00 03 25
TEST PATTERN
HV-LAMP 02
01 FF 01 50 03 00 00 03 24
FACTORY SETTING SET 02
01 FF 01 45 01 00 00 03 22
(*1) SHUTTER SPEED settings are effective only in the condition TRIGGER MODE is OFF or FIXED SHUTTER. (*2) VARIABLE VALUE can be set only when VARIABLE is selected. (*3) VARIABLE VALUE: selectable in the range from 0000 to 060016 (See page 5 to 6 about setting shutter speed). (*4) GAIN: selectable in the range from 000016 to 029F16. Factory setting is 00A816.
(*5) BLACK LEVEL: selectable in the range from 0016 to 3F16. (*6) PARTIAL SCAN START/WIDTH can be set only when PARTIAL SCAN MODE is ON.
(*7) PARTIAL SCAN START/WIDTH: selectable in the range from 000116 to 041016 and the sum total of START and WIDTH is 041116 or less.
Command list
Page 24
16
2. Read command (Note: 1 to 7 and SUM need to be transformed into ASCII code)
1 2 3 4 5 6 7
Item STX
STATUS ID NO.
AREA
ADDRESS
RELATIVE
NO.
DATA
ETX SUM
MODE 02
00 FF 81 04 00 00 00 03 21
POLARITY 02
00 FF 81 0F 00 00 00 03 10
TRIGGER
SOURCE 02
00 FF 81 05 00 00 00 03 20
OUTPUT SIGNAL 02
00 FF 81 06 00 00 00 03 1F
PRESET 02
00 FF 81 08 00 00 00 03 1D
SHUTTER SPEED
VARIABLE VALUE 02
00 FF 81 11 00 00 00 03 23
DATA BIT 02
00 FF 81 14 00 00 00 03 20
VD / FVAL 02
00 FF 81 15 00 00 00 03 1F
HD / LVAL 02
00 FF 81 16 00 00 00 03 1E
GAIN 02
00 FF 81 0C 00 00 00 03 12
BLACK LEVEL 02
00 FF 81 17 00 00 00 03 1D
VERTICAL 2 PIXEL ADDITION 02
00 FF 81 13 00 00 00 03 21
MODE 02
00 FF 81 1E 00 00 00 03 0F
START 02
00 FF 81 1F 00 00 00 03 0E
PARTIAL SCAN
WIDTH 02
00 FF 81 20 00 00 00 03 23
TEST PATTERN 02
00 FF 81 50 00 00 00 03 20
The reading data from the Slave is based on "4. Comms command data format(2)" of "Remote control" (page 14).
Page 25
17
1. Horizontal timing
2. Vertical timing
*Vertical timing for vertical 2 pixel addition mode
*Refer to "Trigger operation and timing chart" for vertical timing when a partial scanning is used.
CameraLink output timing chart
1clk = 34.722ns (28.8000MHz)
HD
VIDEO
50 clk
Active Picture
129 clk 23 clk
LVAL
696 clk
898 clk
2
・・・・
・・・・
・・・・
1
4 3
6 5
8 7
1386
1385
1388
1387
1390
1389
1392
1391
DA DB
VIDEO
VD
1H = 898clk = 31.1806μs
3 H
9 H
1040
1068
16
Active
FVAL
VIDEO
VD
1H = 898clk = 31.1806μs
3 H
3 H
520 H
535 H
9 H
Active
FVAL
Page 26
18
3. Transmitter LVDS output pulse position measurement
(a) 8bit
D.OUT1
N.U.: Not used
(b) 10bit
D.OUT1
N.U.: Not used
Previous Cycle
T
CLK
34.722ns (28.8000MHz)
DA7-1 DA6-1 N.U. DB7 DB6 N.U. N.U. DA7 DA6 DB3-1 DB2-1 N.U. FVAL
LVAL DB5 DB4 DB3 DB2 N.U. DA9-1 DB1 DB0 DB9 DB8 N.U. N.U. DA9 DA1-1 DA0-1 DA8 DA5 DA4 DA3 DA2 DA1 DA0
Next Cycle
(VD) (HD)
TXOUT
0
TXCLKOUT
TXOUT 1
TX
OUT 2
TX
OUT 3
Previous Cycle
T
CLK
34.722ns (28.8000MHz)
DA7-1 DA6-1 N.U. N.U. N.U. DB7 DB6 DA7 DA6 N.U. N.U. N.U. FVAL
LVAL N.U. N.U. N.U. N.U. DB2-1 DB1-1 N.U. N.U. DB5 DB4 DB3 DB2 DB1 DA1-1
DA0-1 DB0 DA5 DA4 DA3 DA2 DA1 DA0
TXOUT 0
TXCLKOUT
Next Cycle
(VD) (HD)
TXOUT 1
TXOUT 2
TXOUT 3
Page 27
19
(c) 12bit
D.OUT1
N.U.: Not used
Please be sure to connect CameraLink cable to D.OUT1.
Previous Cycle
T
CLK
34.722ns (28.8000MHz)
DA7-1 DA6-1 N.U. DB7 DB6 DB11 DB10 DA7 DA6 DB3-1 DB2-1 N.U. FVAL
LVAL DB5 DB4 DB3 DB2 DA10-1 DA9-1 DB1 DB0 DB9 DB8 DA11 DA10 DA9 DA1-1 DA0-1 DA8 DA5 DA4 DA3 DA2 DA1 DA0
Next Cycle
(VD) (HD)
TXOUT 0
TXCLKOUT
TXOUT 1
TXOUT 2
TXOUT 3
Page 28
20
1. Normal mode
(a) Partial scan OFF
1 H = 31.1806 μs
(b) Partial scan ON
1 H = 31.1806 μs
① to ④ are variable by start position of picture grabbing and width of picture grabbing
(omit the figures after the decimal fractions).
① (6+(1055-Width)/10-Start/10)H ② (9+ Start/10)H ③ (Width)H ④ (15+ Width +(1055- Width)/10)H
Trigger operation and timing chart
Shutter time
Shutter time (Camera setting value)
Data output
VD
FVAL
16H
9H
3H
1040H
1068H
Shutter time
Shutter time
(
Camera setting value
)
Data output
VD
FVAL
3H
Page 29
21
Graph following shows frame rate in each of picture grabbing in the partial scan mode.
Note: Frame rate can be calculated from following equations using width of picture grabbing. Lines = 15 + Width + (1055 - Width) / 10 Frame rate = (28800000 / 868) / Lines
*Notes when partial scanning is used
Note1: Please use the partial scan in following condition.
Start + Width ≦ 1041
Note2: Please use FVAL in the partial scan.
KP-F145WCL Partial scan
0
50
100
150
200
250
300
0 200 400 600 800 1000
Width of picture grabbing [H]
Frame rate [fps]
Page 30
22
2. Fixed shutter mode
When external trigger signal is POSITIVE, after the trigger signal rise, exposure is start. The exposure time is set by the camera electronic shutter speed. The video output is obtained immediately after the end of fixed exposure. The strobe signal start/end can be set to shutter time.
(a) Partial scan OFF
1 H =
31.1806 μs
(b) Partial scan ON
1 H =
31.1806 μs
① to ③ are variable by start position of picture grabbing and width of picture grabbing (omit the figures after the decimal fractions).
① (15+Width+(1055- Width)/10)H or more ② (9+Start/10)H ③ (Width)H
Trigger input
(POS)
High Low
Shutter
Shutter time (Camera setting value)
Data
More than 10μs
More than 1068H
FLASH OUT
0.28μs
VD
3H
FVAL
9H
1040H
Trigger input
(POS)
High Low
Shutter time
Shutter time (Camera setting value)
Data output
More than 10μs
FLASH OUT
0.28μs
VD
3H
FVAL
Page 31
23
3. ONE trigger mode
When external trigger signal is POSITIVE, after the trigger signal rise, exposure is start. At the trigger signal falling edge, the internal VD signal is reset and the video data are transmitted. The trigger signal width equals the exposure time.
(a) Partial scan OFF
1 H =
31.1806 μs
(b) Partial scan ON
1 H =
31.1806 μs
① to ③ are variable by start position of picture grabbing and width of picture grabbing (omit the figures after the decimal fractions).
① (15+Width+(1055- Width)/10)H or more ② (9+Start/10)H ③ (Width)H
Trigger input
(POS)
High Low
Shutter time
Shutter time (Integration time)
Data output
More than 1068H
FLASH OUT
0.28μs
VD
3H
FVAL
9H
15.6μs More than
10μs
1040H
Trigger input
(POS)
High Low
Shutter time
Shutter time
(Integration time)
Data output
FLASH OUT
0.28μs
VD
3H
FVAL
15.6μs More
than
Page 32
24
4. VD reset
When external VD pulse is inputted, internal HD/VD is reset.
*Note: When external VD of 30.03 Hz or more is input, electronic shutter has an equation between external VD and 30.03 Hz.
(a) Partial scan OFF
External VD specification: 30.03 Hz or less
1 H =
31.1806 μs
(b) Partial scan ON
1 H =
31.1806 μs
① to ③ are variable by start position of picture grabbing and width of picture grabbing (omit the figures after the decimal fractions).
① (15+Width+(1055- Width)/10)H or more ② (9+Start/10)H ③ (Width)H
Data output
Camera VD
FVAL
VD (Trigger)
input (NEG)
VD output
High Low
3H
3H 0.28μs
More than 10μs
Data output
Camera VD
FVAL
VD (Trigger)
input (NEG)
VD output
High Low
3H
9H
3H 0.28μs
More than 10μs
More than
1068
H
1040H
Page 33
25
1. Input signal The level of the trigger signal input to KP-F145WCL is as follows.
(1) Input from CameraLink cable LVDS level. (2) Input from DCIN/SYNC connector High level : +2.5 to +5.0 V Low level : 0 to +0.3 V
2. Output signal The level of the VD and FLASH output from KP-F145WCL is as follows. High level : +5.0V Low level : 0V
Input / Output signal
Page 34
26
Spectral response of KP-F145WCL is showing.
Spectral response
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
400 500 600 700 800 900 1000
Wave Length (nm)
Relative Response
IR cut filter
Page 35
27
Specifications of KP-F145WCL is showing.
Specifications
KP-F145WCL
1) Imaging device 2/3-inch interline CCD Total pixels 1432 (H) x 1050 (V) Effective pixels 1392 (H) x 1040 (V) Pixel size 6.45μm (H) x 6.45μm (V)
2) Image area 8.98mm (H) x 6.71mm (V)
3) Scanning system Progressive scan
4) Aspect 4:3
5) Frame rate 30rame per second (full pixel readout)
6) Horizontal drive frequency 57.600 MHz
7) Horizontal scanning frequency
32.07 kHz
8) Vertical scanning frequency 30.03 Hz
9) Synchronization Internal
10) Lens mount C mount
11) Frange back 17.526mm (no adjustment)
12) Optical filter
Dummy glass (AR coated)
13) Video output Digital output (CameraLink) Base configuration: 28.8000MHz 2TAP (Note: Maximum digital out cable length is 10 meters.) Output image size 1392 (H) x 1040 (V) (full pixel readout)
14) VD reset input 30.03 Hz or less
15) Resolution
Horizontal / Vertical: 1000 TV lines
16) Sensitivity
400lx, F8, 3200K
17) Minimum illumination
2.0lx, F1.4, Gain MAX
18) S/N
48dB
19) Electronic shutter Preset 1/30, 1/60, 1/100, 1/250, 1/1000, 1/2000, 1/10000, 1/50000 second Variable 10 to 1/100000 second
20) Gamma γ=1
21) Frame on demand Mode OFF (Normal mode), Fixed shutter mode, ONE trigger, VD reset Trigger input
From CameraLink (CC1) or DCIN/SYNC connector
22) Partial scan Selectable start position and width of picture grabbing in 1H step
23) Remote control Control system Start-stop synchronization system Control items TRIGGER、OUTPUT SIGNAL、SHUTTER SPEED、DATA BIT、 VD/FVAL、HD/LVAL、GAIN、BLACK LEVEL、PARTIAL SCAN VERTICAL 2 PIXEL ADDITION 、FACTORY SETTING、TEST PATTERN
24) Power supply DC12V±1V
25) Power consumption Normal mode Approx. 230mA (Approx. 2.76W) Partial scan MAX Approx. 310mA (Approx. 4.0W) when WIDTH: 1H
26) Ambient temperature Performance 0℃ to +40℃ (+32 to +104F) / less than RH 90% Operating -10℃ to +50℃ (+14 to +122F) / less than RH 70% Storage -20℃ to +60℃ (-4 to +140F) / less than RH 70% (without dew condensation)
27) Vibration endurance
10 to 55Hz (2.37 to 71.7 m/s
2
), sweep: 1 minutes, XYZ, 30minutes
28) Shock endurance 490.3m/ s2 (vertical, horizontal, once each faze)
29) Dimensions 44(W) x 44(H) x 41(D) mm
30) Mass Approx. 110g
31) Standard compositions Camera, Composition table
Page 36
28
Dimensions
PLATE,RATED
COLOR:BLACK    
34
±1
10.5
22
±0.5
22
±0.5
10.5
±0.5
0.5
40.5
SEE MANUAL
APERCEVOIR
MANUEL
D.OUT 2
D.OUT 1
2-M2(DEPTH:3)
2-M3(DEPTH:3) 2-M2(DEPTH:3)
21
±1
COLOR:BLACK
47
±1.5
34
±1
28
±0.5
44±0.5
25
±0.5
44
±0.5
28
±0.5
26
±1
U1
25
3×2-M3(DEPTH:3)
4-M3(DEPTH:6)
RoHS
SER.NO.
10
±1
2.5
±0.5
DC IN/SYNC
     
・MAS S: A PPROX 11 0g
・UNI T: m m
・SCA LE: NTS
Page 37
29
Hitachi Kokusai Electric Inc.
UDX Akihabara Bldg. 14-1 Sotokanda 4-choume, Chiyoda-ku, Tokyo 101-8980, Japan Phone: +81(0) 3-6734-9432, Fax: +81(0) 3-5209-5942 URL: http://www.hitachi-kokusai.co.jp
Hitachi Kokusai Electric (Shanghai) Co., Ltd.
Beijing Branch : Room 1413, Beijing Fortune Building, 5 Dong San Huan Bei-Lu, Chao Yang District, Beijing, 100004 China Phone: +86(0) 10-6590-8755/8756, Fax: +86(0) 10-6590-8757
Hitachi Kokusai Electric America, Ltd.
Headquarters and : 150 Crossways Park Drive, Woodbury, New York 11797, U.S.A. Northeast Office Phone: (+1) 516-921-7200, Fax: (+1) 516-496-3718 West Office : 371 Van Ness Way, Suite 120 Torrance, CA, 90501, U.S.A. Phone: (+1) 310-328-6166, Fax: (+1) 310-328-6252 Midwest Sales : Phone: (+1) 330-334-4115, Fax: (+1) 516-496-3718 Service (+1) 989-345-5379 South Sales : Service (+1) 256-774-3777 Parts Center : phone (+1) 516-682-4435, Fax: (+1) 516-921-0993 Latin Sales : phone (+1) 519-682-4420, Fax: (+1) 516-496-3718 URL: http://www.hitachikokusai.us
Hitachi Kokusai Electric Canada, Ltd.
Head Office : 1 Select Avenue Unit#12 Scarborough, Ontario M1V 5J3, Canada Phone: (+1) 416-299-5900, Fax: (+1) 416-299-0450 Eastern Office : 5795 Chemin St. Francois St. Laurent, Quebec H4S 1B6, Canada Phone: (+1) 514-332-6687, Fax: (+1) 514-335-1664 URL: http://www.hitachikokusai.ca