This monitor is ENERGY STAR ® compliant when used with a computer equipped with VESA DPMS.

The ENERGY STAR ® emblem does not represent EPA endorsement of any product or service.

As an ENERGY STAR ® Partner, Hitachi,Ltd. has determined that this product meets the ENERGY

STAR ® guidelines for energy efficiency.

ENGLISH

USER'S MANUAL

Thank you very much for purchasing the HITACHI Plasma Display Monitor.

Before using your monitor, please carefully read the "SAFETY GUIDELINES" and this "USER'S MANUAL" so you will know how to operate the monitor properly. Keep this manual in a safe place. You will find it useful in the future.

Notes on lnstallation Work:

This product is marketed assuming that it is installed by qualifed personnel with enough skill and competence. Always have an installation specialist or your dealer install and set up the product. HITACHI cannot assume liabilities for damage caused by mistake in installation or mounting, misuse, modification or a natural disaster.

Note for Dealers:

After installation, be sure to deliver this manual to the customer and explain to the customer how to handle the product.

FEATURES

CONTENTS

 

 

FEATURES ....................................................

2

 

SAFETY GUIDELINES ..................................

3

 

STANDARD ACCESSORIES ..........................

7

 

Component Names ......................................

8

 

Main Unit..............................................................................

8

 

Remote controller ................................................................

9

 

Loading Batteries ................................................................

9

 

Handling the Remote Controller ..........................................

9

 

INSTALLATION INSTRUCTIONS ................

10

 

Installation..........................................................................

10

 

Anti-tumble measures........................................................

10

 

Connecting to a PC ..........................................................

11

 

Connecting to a Video Imaging Device ............................

12

 

Power Cord Connection ....................................................

13

 

Mounting the Video Unit ..................................................

13

 

Mounting the Speaker Unit ..............................................

13

 

OPERATING INSTRUCTIONS ....................

14

 

Turning Power On and Off ................................................

14

 

Input Switching ..................................................................

15

 

Volume Adjustment............................................................

15

 

Audio Mute ........................................................................

15

 

Size Switching ..................................................................

16

 

Displaying Two Screens ....................................................

16

 

Input Signal Screen Display ..............................................

16

 

Automatic Adjustment of Screen Position and the Clock ..

17

 

Independent Operation of Multiple Monitors ....................

17

 

Using the Menu Screen ....................................................

17

 

PICTURE MENU ................................................................

18

 

..................................................................SOUND MENU

19

 

................................................................DISPLAY MENU

20

 

FUNCTION MENU ............................................................

22

 

OTHER MENU ..................................................................

23

 

OTHER FEATURES ....................................

24

 

Automatic Store ................................................................

24

 

Signal Check ....................................................................

24

 

Power Save Mode..............................................................

25

 

TWO SCREEN TABLE..................................

25

 

IMAGE RETENTION OF PLASMA DISPLAY

26

 

 

NOTES

26

 

 

TROUBLESHOOTING..................................

27

 

Symptoms That Seemingly Appear to be Failures ............

27

 

Actions to Correct Abnormal Displays ..............................

29

 

PRODUCT SPECIFICATIONS ......................

30

 

Signal Input........................................................................

31

 

Recommended Signal List ................................................

31

Notes about This Manual

The information in this manual is subject to change without notice.

While meticulous care has been taken in the preparation of this manual, you are requested to notify your dealer or us should you have any comments, views or questions about our product.

Fully understand the prerequisites to using the product, such as hardware and software specifications and constraints, in using the product. We are not held liable for damages caused by improper handling of the product.

Reproduction of this manual in whole or in part without our prior written permission is prohibited.

The product names mentioned in this manual may be trademarks or registered trademarks of their respective owners.

2

SAFETY GUIDELINES

This monitor is designed to be safe to use. However, fire or serious injury may occur unless you use this monitor in the proper way. Please follow the instructions shown below in order to avoid injury.

Keep the safety guideline

Do not use the monitor if it fails

If you find something unusual ,

* If smoke comes out,

* If there is a strange smell,

(1) Turn off the monitor

* If water enters the case,

(2) Disconnect the power plug from the mains

* If you drop the monitor or damage the cabinet,

(3) Request repair

Warning and Caution are indicated in this guide and monitor itself.

WARNING

Fire or electric shock may cause death or serious injury unless you follow the instruction.

 

 

 

 

CAUTION

Electric shock or other accidents may cause serious injury or damage of your properties.

 

 

 

 

WARNING

Fire or electric shock may cause death or serious injury unless you follow the instruction below.

 

 

• If something smells strange or smoke comes from the monitor:

Turn off the monitor and disconnect the power plug from the mains immediately. Contact service center after confirming that the smoking has stopped.

If you continue to operate the monitor with such abnormal condition, it may cause fire or you may receive an electric shock.

• Do not drop water or a foreign substance on to the monitor.

If you drop water or a foreign substance on to the monitor, it may cause fire or an electric shock.

If it happens turn off the monitor and disconnect the power plug from the mains and ask service center for instruction.

• Do not put the monitor on an unstable place.

If you put the monitor on an uneven or unstable place, it may fall down and you may be injured. Put the monitor on a flat surface strong enough to take the weight.

Do not apply shock to the monitor.

Do not use monitor if glass is broken or damaged.

If there is no picture appearance, broken glass , smoking or something smells after applying shock to the monitor, turn off the monitor and disconnect the power plug from the mains immediately. Then, call the service center.

If you continue to operate the monitor with such abnormal conditions, it may cause fire or you may receive an electric shock.

• Do not disassemble or modify the monitor.

There is high voltage portion inside of the monitor. Disassembling or modification of the monitor may cause fire or electric shock.

• Do not use the monitor in wet environment.

If you use the monitor in a wet place such as bath or shower room, it may cause fire or electric shock.

• Do not damage or modify the power cord.

If you put something heavy on the power cord or pull, squeeze, heat the cord, it may be damaged and it may cause fire or electric shock. If the power cord is damaged, call service center.

ENGLISH

3

SAFETY GUIDELINES(continued)

WARNING Fire or electric shock may cause death or serious injury unless you follow the instruction.

• The enclosed power cord must be used!

Failure to do so may cause electric shock hazard or fire hazard.

In USA/Canada, use a UL LISTED/CSA LABELLED or CERTIFIED power cord set meeting the following specifications : Rating: min. 125V, 10A , Length: max. 3.0m , Type: SVT or SJT

Plug type: NEMA 5-15P figure, Parallel blade, Grounding type

In Europe or 200V area, a proper European standard approved power cord is to be used with this monitor.

For a rated current up to 6 A, a type not lighter than H05VV-F 3G 0.75 mm2 or H05VVH2-F 3G 0.75 mm2 must be used.

• Use only the correct voltage power outlet with safety ground connection!

100 - 120 V for USA, Canada, etc.

200 - 240 V for Europe, etc.

(This monitor will automatically adjust to the input voltage 100 - 120 / 200 - 240V.)

• Be careful of power cord connection!

Before inserting the plug of the power cord into a socket of the correct voltage, check that the connection portion of the power cord is clean (with no dust). Then, insert the plug of power cord into the socket firmly, otherwise it may cause electric shock or fire hazard.

• Do not touch the power plug when lightning is close to you.

You may receive an electric shock.

• Do not touch the power plug with wet hands.

You may receive an electric shock.

• Do not obstruct a ventilation hole.

If you obstruct a ventilation hole during the operation of the monitor or just after switching off the power, it may cause a fire or electric shock due to heating up the monitor.

Do not put the monitor screen side up.

Do not put the monitor on a shelf or in a cabinet without adequate ventilation of 4 inches top, sides, bottom and rear.

Do not put the monitor on a carpet or mattress.

Do not cover the monitor with a cloth.

FOR THE CUSTOMERS IN THE U.K.

THIS PRODUCT IS SUPPLIED WITH A TWO PIN MAINS PLUG FOR USE IN MAINLAND EUROPE. FOR THE U.K. PLEASE REFER TO THE NOTES ON THIS PAGE.

IMPORTANT FOR UNITED KINGDOM

WORDING FOR CLASS I EQUIPMENT INSTRUCTION BOOKS AND LABELS

The mains lead on this equipment is supplied with a molded plug incorporating a fuse, the value of which is indicated on the pin face of the plug. Should the fuse need to be replaced, an ASTA or BSI approved BS 1362 fuse must be used of the same rating. If the fuse cover is detachable never use the plug with the cover omitted. If a replacement fuse cover is required, ensure it is of the same colour as that visible on the pin face of the plug. Fuse covers are available from your dealer.

DO NOT cut off the mains plug from this equipment. If the plug fitted is not suitable for the power points in your home or the cable is too short to reach a power point, then obtain an appropriate safety approved extension lead or consult your dealer.

Should it be necessary to change the mains plugs, this must be carried out by a competent person, preferably a qualified electrician.

If there is no alternative to cutting off the mains plug, ensure that you dispose of it immediately, having first removed the fuse, to avoid a possible shock hazard by inadvertent connection to the mains supply.

WARNING: THIS EQUIPMENT MUST BE EARTHED IMPORTANT

The wires in the mains lead are coloured in accordance with the following code : Green and Yellow = Earth, Blue = Neutral, Brown = Live.

As these colours may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

The wire which is coloured GREEN and YELLOW must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured GREEN or GREEN and

Green & Yellow

 

Brown to Live

 

to Earth

 

Fuse

 

 

Blue to Neutral

 

Cord Clamp

 

 

YELLOW.

The wire coloured BLUE must be connected to the terminal marked with the letter N or coloured BLUE or BLACK. The wire coloured BROWN must be connected to the terminal marked with the letter L or coloured BROWN or RED.

4

SAFETY GUIDELINES(continued)

or damage to your property.

the monitor.

the cord and cause a fire or electric shock. You are

shock.

electric shock.

use the monitor for a long time.

high humidity, and dust.

of time. Heat may cause a fire, transformation, or

CAUTION

You may have serious injury or your property may be damaged unless you follow the instruction below.

 

 

• Do not coil or wind the power cord.

This may cause excessive heat resulting in a fire.

• Caution for 200 - 240V operation only

This equipment relies on the protective devices in the building installation for short - circuit and over - current protection. Refer to the following table for the suitable number and location of the protective devices which should be provided in the building installation.

INFORMATIVE EXAMPLES OF PROTECTIVE DEVICES IN SINGLE - PHASE

EQUIPMENT OR SUB - ASSEMBLIES

 

Protection

Minimum number

 

 

of fuses or circuit -

Location

 

against

 

breaker poles

 

 

 

 

 

 

 

 

Case A: Equipment to be connected to

Earth faults

1

Phase conductor

POWER SYSTEMS with earthed neutral

 

 

 

 

 

 

reliably identified, except for Case C below.

Overcurrent

1

Either of the two conductors

 

 

 

 

Case B: Equipment to be connected to any

Earth faults

2

Both conductors

supply, including IT POWER SYSTEMS and

 

 

 

supplies with reversible plugs, except for

 

 

 

Overcurrent

1

Either of the twoconductors

Case C below.

 

 

 

 

 

 

 

Case C: Equipment to be connected to 3 -

Earth faults

2

Each phase conductor

wire power systems with earthed neutral

 

 

 

 

 

 

reliably identified.

Overcurrent

2

Each phase conductor

 

 

 

 

Verify that the protective devices in the building installation meets the conditions in the table prior to installing the equipment.

• Remove the power cord for complete isolation!

For complete isolation from the mains, remove the power cord from the monitor or from the wall socket.

ENGLISH

5

SAFETY GUIDELINES(continued)

PRECAUTIONS

• Installation environment

Do not obstruct a ventilation hole.

Do not put the monitor on carpet or blanket, or near a curtain which has a possibility of obstructing a ventilation hole of the monitor.

Do not put the monitor in the following places.

Hot places such as near heater, place exposed to the direct rays of the sun.

A place where the temperature is widely changing.

Places with soot, dust or high humidity.

Poor air ventilation place.

Place near fire.

A wet place such as bathroom, or shower room.

Place where you can trip over it.

Always vibrating or strongly vibrating places.

Distorted or unstable places.

How to view the monitor.

If you use the monitor in too dark a room, your eyes may become tired.

Please use it in a reasonably bright room.

Avoid direct rays of the sun to the screen in order to prevent eye fatigue.

Your eyes will get fatigued after viewing the monitor for long period of time.

Relax your eyes by viewing away from the monitor from time to time.

Please watch the monitor in downward direction.

• Note on image retention

The plasma monitor illuminates phosphor to display images. The phosphor has a finite illumination life. After extended periods of illumination, the brightness of the phosphor would be degraded to such extent that still images would image retention that part of the screen as grayed-out images.

Tips to prevent such image retention are:

-Do not display images having sharp brightness differences or high-contrast images, such as monochrome characters and graphic patterns, for long.

-Do not leave stationary images appearing for long, but try to refresh them at appropriate intervals of time, or try to move them using screen saver function.

-Turn down the contrast and brightness controls.

How to clean the monitor.

Before cleaning the monitor, turn off the monitor and disconnect the power plug from the mains. When cleaning the monitor, do not spray directly the screen or cabinet with cleaner.

Use a clean, dust free, dry and soft cloth. If it is not enough, then use a cloth with non-alcoholic or non-ammonia detergent. Do not rub the surface of the screen with ball-point-pen or screw-driver etc.

• Prevention of an obstacle to Radio receivers

This monitor has been designed pursuant to the EN55022 class B Rules. This is to prevent a problem to Radio receivers.

-Keep the monitor away from Radio.

-Adjust Radio antennas in order for the monitor not to receive interference.

-The antenna cable of Radio should be kept away from the monitor.

-Use a coaxial cable for antenna.

You can check if this monitor influences Radio receivers by turning off all other equipment other than the monitor. If you find a problem receiving Radio when using the monitor, check the instructions mentioned above.

Precautions for the monitor

-Use the attached signal-cable when you connect the monitor with PC equipment. Do not use other signal-cables.

-Confirm the connector is fixed tightly when the signal cable is connected. Also confirm the screws on the connector are tightened.

-Plug the power cord of the monitor into a different socket from that for other equipment, such as Radio etc..

-Use a plug with ground terminal and make sure that it connects to the ground.

Precaution during transportation

Please pay attention when you transport this monitor because it is heavy.

Furthermore, use the original carton box and its packaging materials when the monitor is transported.

Failure to transport the monitor in any carton except the original carton may result in damage to the monitor.

Save the original carton box and all packing material.

6

STANDARD ACCESSORIES

ENGLISH

Power cable

Read the user manual (this book) and keep them in a safe place for handy reference.

•Retain the packing materials for use in future shipping or relocation.

7

Hitachi CMP4121HDE, CMP4202E, 42PMA400E User Manual

Component Names

Main Unit

Front

Panel

Cabinet

 

(front frame)

Control panel

Adjustment buttons are located on the bottom.

• The back cover is provided with indications to distinguish the adjustment buttons.

SUB-POWER button 14

VOLUME button 15

RECALL button 16

SIZE button 16

INPUT SELECT button 15

Remote-control receiver 9

Indicator lamp 14

The main power switch is located at the back, on the lower surface.

Main power switch 14

Rear

Caution when moving the main unit

 

• As this product is heavy, whenever it is moved, two

Handgrips

people are required to transport it safely.

Whenever the unit is moved it should be lifted forwards using the two handgrips at the back, and the unit should

then be held at the base on both sides for stability.

External

speaker

 

Handgrips

terminals

 

 

12

Handgrips

External speaker terminals

12

External device connection terminals

RS232C

RGB 2

RGB 1

AUDIO IN

 

 

 

D-SUB IN

D-SUB IN

RGB input terminals 11

8

Component Names (continued)

Remote controller

POWER OFF button 14

POWER ON button 14

 

 

 

 

14 POWER ON/OFF button

 

 

 

 

 

 

MUTE button 15

 

 

 

 

15

VOLUME UP/DOWN button

SIZE button 16

 

 

 

 

 

 

 

VOL

 

 

PinP button

 

 

 

MUTE

VOL

 

 

16

 

 

 

 

16

RECALL button

 

 

AUTO

PinP

SIZE

RECALL

AUTO button 17

 

 

 

 

 

 

 

 

 

 

RGB 1

RGB 2

VIDEO 1

VIDEO 2

15

RGB/VIDEO buttons

 

 

 

 

 

 

MENU button

17

MENU

 

 

RETURN

 

 

 

 

 

 

17

RETURN button

 

 

 

 

 

 

 

 

 

ENTER

 

 

 

ENTER button 17

ID

 

 

ID SET

17 SELECT/ADJUST buttons

ID button

17

 

 

 

 

17

ID SET button

Loading Batteries

1. Open the battery cover.

• Slide back and remove the battery cover in the direction of the arrow.

2.Load batteries.

Load two Size AA batteries included observing polarities.

3) Close the battery cover.

Replace the battery cover in the direction of the arrow and snap it back into place.

CAUTIONS

Do not use new and old batteries together. The batteries could explode or leak, resulting in fires, physical injury, or stains.

When loading batteries, observe their correct polarities as marked on the product. If loaded in the wrong direction, the batteries could explode or leak, resulting in fires, physical injury, or stains.

Handling the Remote Controller

Use the remote controller within about 5 m from front of the unit’s remote-control sensor and within 30 degrees on both sides.

With in 30 With in 30 degrees degrees

About 3m

About 3m

About 5m

TIPS

Do not drop or impact the remote controller.

Do not splash the remote controller with water or put it on a wet object to avoid possible failures.

Before leaving the remote controller out of use for an extended period of time, remove the batteries from it.

If the remote controller begins to lack responsiveness, replace the batteries.

Strong light such as direct sunlight impinging on the photoreceptor of the remote control can cause operational failure. Position this unit to avoid direct contact with such light.

ENGLISH

9

INSTALLATION INSTRUCTIONS

Installation

WARNING

Use one of the special mount units to install this product. A mount of insufficient strength or inadequate design can cause overturning or dropping and result in fire, electrical shock or injury. Please note that our company assumes absolutely no responsibility for personal injuries or property damage caused by use of other mount units or improper installation.

CAUTIONS

• Installation of the wall mount unit and

 

 

 

 

 

more*

ceiling mount unit can be dangerous, so

10cm (4 inches)

or

 

 

 

 

 

 

 

 

do not attempt this work yourself. Ask your

 

 

 

 

 

 

 

 

dealer to provide the name of a qualified

 

 

 

 

 

 

 

 

installer.

 

Clamp

 

 

 

 

 

 

 

 

 

 

 

 

 

• In order to prevent an internal temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

increase, maintain a space of 10cm (4

 

 

 

 

 

 

 

 

 

Cord

 

 

 

 

 

inches : For a desktop set-up) or more

 

or

 

 

 

 

 

 

chain

 

 

 

 

 

 

 

 

 

between the sides and other objects such as walls, etc., so that the ventilation holes are not blocked.*

Using the optional vertical-mount unit (CMPAK15)

Using the optional wall-mount unit (CMPAK15) allows set to mount on wall surfaces as shown at below.

1)Make at least four sets of commercial anchor bolts and screws available to meet various kinds of walls to mount on.

2)Read the instructions supplied with the wall-mount unit carefully to optimally locate the plasma display on a wall surface.

3)Prepare the wall surface for anchoring and drilling as needed, as shown in the sketches.

Make sure that an adequate wall surface strength and a screw holding strength are available.

Indicating lamp

Horizontal mounting

Upper left vertical

 

mounting

Horizontal mounting

SPEAKER

SPEAKER

TERMINAL

TERMINAL

8

8W

8

8W

Plasma display outline

Anti-tumble measures

CAUTIONS

Have this unit mounted in a stable place. Take measures to prevent it from tumbling down to avoid possible physical injury.

Securing to a wall or pillar 10cm (4 inches) or more*

Using a commercially available cord, chain and clamp, secure the set to a firm

wall or pillar.

Clamp

Cord or chain

Securing desktop

1)Using wood screws (two), fasten the set to the clamping screw holes on the rear of the stand as shown.

2)Using commercially available wood screws, secure the set firmly in position.

Vis bois Deux endroits

Upper left vertical mounting

Side view

SPEAKER TERMINAL 8 8W

SPEAKER TERMINAL 8 8W

Plasma display outline

Driving anchor bolts into a wall surface

Wall surface

Anchor bolt

Hold to 25 mm (1 inch) or below.