Hitachi 3080 G2, 3090 G2 Hardware Reference Manual

Page 1
Hitachi NAS Platform
3080 and 3090 G2 Hardware Reference
Release 12.2
MK-92HNAS017-05
Page 2
© 2011-2015 Hitachi, Ltd. All rights reserved.
No part of this publication may be reproduced or tr
ansmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose without the express written permission of Hitachi, Ltd.
Hitachi, Ltd., reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. This document contains the most current information available at the time of publication. When new or revised information becomes available, this entire document will be updated and distributed to all registered users.
Some of the features described in this document might not be currently available. Refer to the most recent product announcement for information about feature and product availability, or contact Hitachi Data Systems Corporation at
https://portal.hds.com.
Notice: Hitachi, Ltd., products and services can be ordered only under the terms and conditions of the applicable Hitachi Data S
ystems Corporation agreements. The use of Hitachi, Ltd., products is governed by the terms of your agreements with Hitachi Data Systems Corporation.
2
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 3
Hitachi Data Systems products and services can be ordered only under the terms and conditions of Hitachi Data S
ystems’ applicable agreements. The use of Hitachi Data Systems products is governed by the terms of your agreements with Hitachi Data Systems.
Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries. Hitachi Data Systems is a registered trademark and service mark of Hitachi, Ltd., in the United States and other countries.
Archivas, Dynamic Provisioning, Essential NAS Platform, HiCommand, Hi-Track, ShadowImage, Tagmaserve, Tagmasoft, Tagmasolve, Tagmastore, TrueCopy, Universal Star Network, and Universal Storage Platform are registered trademarks of Hitachi Data Systems Corporation.
AIX, AS/400, DB2, Domino, DS8000, Enterprise Storage Server, ESCON, FICON, FlashCopy, IBM, Lotus, OS/390, RS6000, S/390, System z9, System z10, Tivoli, VM/ ESA, z/OS, z9, zSeries, z/VM, z/VSE are registered trademarks and DS6000, MVS, and z10 are trademarks of International Business Machines Corporation.
All other trademarks, service marks, and company names in this document or website are properties of their respective owners.
Microsoft product screen shots are reprinted with permission from Microsoft Corporation.
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/). Some parts of ADC use open source code from Network Appliance, Inc. and Traakan, Inc.
Part of the software embedded in this product is gSOAP software. Portions created by gSOAP are copyright 2001-2009 Robert A. Van Engelen, Genivia Inc. All rights reserved. The software in this product was in part provided by Genivia Inc. and any express or implied warranties, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose are disclaimed. In no event shall the author be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including, but not limited to, procurement of substitute goods or services; loss of use, data, or profits; or business interruption) however caused and on any theory of liability, whether in contract, strict liability, or tort (including negligence or otherwise) arising in any way out of the use of this software, even if advised of the possibility of such damage.
The product described in this guide may be protected by one or more U.S. patents, foreign patents, or pending applications.
Notice of Export Controls
Export of technical data contained in this document may require an export license from the United States government and/or the government of Japan. Contact the Hitachi Data Systems Legal Department for any export compliance questions.
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
3
Page 4

Contents

eface................................................................................................. 8
Pr
Contacting Hitachi Data Systems...............................................................................8
Related Documentation............................................................................................ 8
1 About this manual................................................................................12
Audience............................................................................................................... 13
Conventions...........................................................................................................13
Related documentation...........................................................................................17
2 Safety information............................................................................... 20
Electrostatic discharge precautions.......................................................................... 21
Safety and handling precautions..............................................................................21
Electrical precautions..............................................................................................22
Data protection precautions.................................................................................... 22
3 Mandatory regulations..........................................................................24
International standards...........................................................................................25
Federal Communications Commission (FCC)............................................................. 25
European Union (EU) Statement..............................................................................26
Canadian Department of Communication Compliance Statement............................... 26
Avis de conformité aux normes du ministère des Communications du Canada....... 27
Radio Protection for Germany................................................................................. 27
Food and Drug Administration (FDA)....................................................................... 27
Chinese RoHS Compliance Statement...................................................................... 27
4 System overview..................................................................................30
System components............................................................................................... 31
Server specifications...............................................................................................32
Attaching a rack stabilizer plate...............................................................................34
4
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 5
5 Hitachi NAS Platform server components............................................... 36
V
entilation............................................................................................................. 38
Server front panel.................................................................................................. 38
LED status indicators..............................................................................................39
NVRAM backup battery pack................................................................................... 42
Hard disk drives..................................................................................................... 44
Fans......................................................................................................................45
Server rear panel................................................................................................... 46
Rear panel server LED and button locations............................................................. 48
Rear panel LED state descriptions...................................................................... 48
Power button (PWR)......................................................................................... 49
Reset button (RST)...........................................................................................50
Fibre channel storage ports............................................................................... 50
10/100 private Ethernet ports............................................................................51
GE Ethernet network ports ............................................................................... 52
10 GbE Ports.................................................................................................... 52
10 Gigabit Ethernet cluster interconnect ports............................................... 52
10 Gigabit Ethernet customer data network ports.......................................... 53
Power supply units ...........................................................................................54
Ethernet management ports 0 and 1..................................................................56
Serial port .......................................................................................................56
USB ports.........................................................................................................56
Management interfaces.......................................................................................... 56
RS-232 serial management port ........................................................................57
10/100/1000 Ethernet management ports.......................................................... 58
Ethernet cables .....................................................................................................58
6 Replacing server components............................................................... 60
Field-replaceable units............................................................................................61
Hot-swappable components.................................................................................... 61
Removing and replacing the front bezel................................................................... 62
Bezel removal...................................................................................................62
Bezel replacement............................................................................................ 62
Replacing a fan......................................................................................................62
Replacing the NVRAM backup battery pack.............................................................. 64
Checking battery pack status.............................................................................64
Identifying a cluster node that requires battery replacement ...............................65
Replacing the NVRAM battery module................................................................ 66
Replacing a hard disk............................................................................................. 67
Deciding on hard disk recovery or replacement...................................................67
Replacing a hard disk drive................................................................................68
Synchronizing a new disk.................................................................................. 70
Replacing a power supply unit.................................................................................71
Replacing an FPGA board as a FRU..........................................................................72
Requirements for Replacing FPGA board.............................................................73
Replacing the FPGA board................................................................................. 73
7 Rebooting, shutting down, and powering off..........................................80
Rebooting or shutting down a server....................................................................... 81
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
5
Page 6
Rebooting or shutting down a cluster.......................................................................82
R
estarting an unresponsive server...........................................................................83
Powering down the server for maintenance..............................................................85
Powering down the server for shipment or storage................................................... 85
Powering on the server or cluster............................................................................86
Recovering from power standby..............................................................................87
A Server replacement procedures............................................................88
Replacement procedure overview............................................................................89
Requirements...................................................................................................89
Swapping components...................................................................................... 89
Model selection.................................................................................................90
MAC ID and license keys................................................................................... 90
Previous backups..............................................................................................90
Upgrades......................................................................................................... 91
Replacing a single server with an embedded SMU.....................................................91
Obtaining backups, diagnostics, firmware levels, and license keys........................ 91
Shutting down the server you are replacing........................................................93
Configuring the replacement server....................................................................95
Finalizing and verifying the replacement server configuration...............................97
Replacing a single server with an external SMU........................................................ 99
Obtaining backups, diagnostics, firmware levels, and license keys........................ 99
Shutting down the server you are replacing...................................................... 101
Configuring the replacement server..................................................................103
Finalizing and verifying the replacement server configuration............................. 105
Replacing a node within a cluster.......................................................................... 107
Obtaining backups, diagnostics, firmware levels, and license keys...................... 107
Shutting down the server you are replacing...................................................... 109
Configuring the replacement server..................................................................111
Finalizing and verifying the server configuration................................................ 113
Replacing all servers within a cluster......................................................................116
Obtaining backups, diagnostics, firmware levels, and license keys...................... 116
Shutting down the servers you are replacing.....................................................118
Configuring the replacement servers................................................................ 120
Finalizing and verifying the system configuration...............................................122
B Parts list for 3080/3090 G2 servers......................................................124
6
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 7
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
7
Page 8
This manual provides an overview of the Hitachi NAS Platform and the Hitachi Unified Storage File Module hardware. The manual explains how to install and configure the hardware and software, and how to replace faulty components.
The following server models are covered: 3080 and 3090
For assistance with storage arrays connected to the server, refer to the Storage Subsystem Administration Guide.

Contacting Hitachi Data Systems

2845 Lafayette Street Santa Clara, California 95050-2627 U.S.A.
https://portal.hds.com
North America: 1-800-446-0744

Related Documentation

Preface

Release Notes pro including new feature summaries, upgrade instructions, and fixed and known defects.
Administration Guides
System Access Guide (MK-92HNAS014)—In PDF format, this guide explains how to log in to the system, provides information about accessing the NAS server/cluster CLI and the SMU CLI, and provides information about the documentation, help, and search capabilities available in the system.
Server and Cluster Administration Guide (MK-92HNAS010)—In PDF format, this guide provides information about administering servers, clusters, and server farms. Includes information about licensing, name spaces, upgrading firmware, monitoring servers and clusters, the backing up and restoring configurations.
Storage System User Administration Guide (MK-92HNAS013)—In PDF format, this guide explains user management, including the different types of system administrator, their roles, and how to create and manage these users.
Network Administration Guide (MK-92HNAS008)—In PDF format, this guide provides information about the server's network usage, and explains
vide the most up-to-date information about the system,
8 Preface
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 9
how to configure network interfaces, IP addressing, name and directory services.
File Services Administration Guide (MK
-92HNAS006)—In PDF format, this guide explains about file system formats, and provides information about creating and managing file systems, and enabling and configuring file services (file service protocols).
Data Migrator Administration Guide (MK-92HNAS005) —In PDF format, this guide provides information about the Data Migrator feature, including how to set up migration policies and schedules.
Storage Subsystem Administration Guide (MK-92HNAS012)—In PDF format, this guide provides information about managing the supported storage subsystems (RAID arrays) attached to the server/cluster. Includes information about tiered storage, storage pools, system drives (SDs), SD groups, and other storage device related configuration and management features and functions.
Snapshot Administration Guide (MK-92HNAS011)—In PDF format, this guide provides information about configuring the server to take and manage snapshots.
Replication and Disaster Recovery Administration Guide (MK-92HNAS009) —In PDF format, this guide provides information about replicating data using file-based replication and object-based replication, provides information on setting up replication policies and schedules, and using replication features for disaster recovery purposes.
Antivirus Administration Guide (MK-92HNAS004)—In PDF format, this guide describes the supported antivirus engines, provides information about how to enable them, and how to configure the system to use them.
Backup Administration Guide (MK-92HNAS007)—In PDF format, this guide provides information about configuring the server to work with NDMP, and making and managing NDMP backups. Also includes information about Hitachi NAS Synchronous Image Backup.
Command Line Reference—Opens in a browser, and describes the commands used to administer the system.
Note: F
or a complete list of Hitachi NAS open source software copyrights and
licenses, see the System Access Guide.
Hardware References
Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference (MK
-92HNAS016)—Provides an overview of the second-generation server hardware, describes how to resolve any problems, and replace potentially faulty parts.
Hitachi NAS Platform 3080 and 3090 G2 Hardware Reference (MK-92HNAS017)—Provides an overview of the second-generation server hardware, describes how to resolve any problems, and replace potentially faulty parts.
Preface 9
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 10
Hitachi NAS Platform Series 4000
Hardware Reference (MK-92HNAS030)
(MK-92HNAS030)—Provides an overview of the Hitachi NAS Platform Series 4000 server hardware, describes how to resolve any problems, and how to replace potentially faulty components.
Hitachi High-performance NAS Platform (MK-99BA012-13)—Provides an overview of the NAS Platform 3100/NAS Platform 3200 server hardware, and describes how to resolve any problems, and replace potentially faulty parts.
Best Practices
Hitachi USP-V/VSP Best Practice Guide for HNAS Solutions (MK-92HNAS025)—The HNAS practices outlined in this document describe how to configure the HNAS system to achieve the best results.
Hitachi Unified Storage VM Best Practices Guide for HNAS Solutions (MK-92HNAS026)—The HNAS system is capable of heavily driving a storage array and disks. The HNAS practices outlined in this document describe how to configure the HNAS system to achieve the best results.
Hitachi NAS Platform Best Practices Guide for NFS with VMware vSphere (MK-92HNAS028)—This document covers VMware best practices specific to HDS HNAS storage.
Hitachi NAS Platform Deduplication Best Practice (MK-92HNAS031) —This document provides best practices and guidelines for using HNAS Deduplication.
Hitachi NAS Platform Best Practices for Tiered File Systems (MK-92HNAS038) —This document describes the Hitachi NAS Platform feature that automatically and intelligently separates data and metadata onto different Tiers of storage called Tiered File Systems (TFS).
Hitachi NAS Platform Data Migrator to Cloud Best Practices Guide (MK-92HNAS045)—Data Migrator to Cloud allows files hosted on the HNAS server to be transparently migrated to cloud storage, providing the benefits associated with both local and cloud storage.
Brocade VDX 6730 Switch Configuration for use in an HNAS Cluster Configuration Guide (MK-92HNAS046)—This document describes how to configure a Brocade VDX 6730 switch for use as an ISL (inter-switch link) or an ICC (inter-cluster communication) switch.
Best Practices for Hitachi NAS Universal Migrator (MK-92HNAS047)—The Hitachi NAS Universal Migrator (UM) feature provides customers with a convenient and minimally disruptive method to migrate from their existing NAS system to the Hitachi NAS Platform. The practices and recommendations outlined in this document describe how to best use this feature.
Hitachi NAS Platform Storage Pool and HDP Best Practices (MK-92HNAS048)—This document details the best practices for configuring and using HNAS storage pools, related features, and Hitachi Dynamic Provisioning (HDP).
10 Preface
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 11
Hitachi Data Systems SU 12.x Network File System (NFS) Version 4 Feature Description
(MK-92HNAS056)—This document describes the
features of Network File System (NFS) Version 4.
Preface 11
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 12
1

About this manual

This manual pro Unified Storage File Module hardware. The manual explains how to install and configure the hardware and software, and how to replace faulty components.
The following server models are covered: 3080 and 3090.
For assistance with storage arrays connected to the server, refer to the Storage Subsystem Administration Guide.
Audience
Conventions
Related documentation
vides an overview of the Hitachi NAS Platform and the Hitachi
12 About this manual
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 13

Audience

This guide is written for owners and field service personnel who ma repair the system hardware. It is written with the assumption that the reader has a good working knowledge of computer systems and the replacement of computer parts.

Conventions

The following conventions are used throughout this document:
Convention Meaning
Command
variable The italic typeface denotes variable entries and words or concepts being
user input
[ and ] Brackets enclose optional portions of a command or directive line.
Ellipses indicate that a preceding element can be repeated.
GUI element This font denotes the names of graphical user interface (GUI) elements
y have to
This fixed-space font denotes literal items such as commands, files, routines, path names, signals, messages, and progr structures.
defined. Italic typeface is also used for book titles.
This bold fixed-space font denotes literal items that the user enters in interactive sessions. Output is shown in nonbold, fixed-space font.
such as windows, screens, dialog boxes, menus, toolbars, icons, buttons, boxes, fields, and lists.
amming language
The following types of messages are used throughout this manual. It is recommended that these icons and messages are read and clearly understood before proceeding:
A tip contains supplementary information that is useful in completing a task.
A note contains information that helps to install or operate the system effectiv
ely.
About this manual 13
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 14
A caution indicates the possibility of damage to data or equipment. Do not proceed bey
A warning contains instructions that you must follow to avoid personal injury.
ond a caution message until the requirements are fully understood.
Før du starter (DANSK)
ølgende ikoner anvendes i hele guiden til at anføre sikkerhedsrisici. Det
F anbefales, at du læser og sætter dig ind i, og har forstået alle procedurer, der er markeret med disse ikoner, inden du fortsætter.
Bemærk: “Bemærk” indikerer informationer, som skal bemærkes.
FORSIGTIG: “Forsigtig” angiver en mulig risiko for beskadigelse af data eller
udstyr. Det anbefales, at du ikke fortsætter længere end det afsnit, der er mærket med dette ord, før du helt har sat dig ind i og forstået proceduren.
ADVARSEL: “Advarsel” angiver en mulig risiko for den personlige sikkerhed.
Vorbereitung (DEUTSCH)
Die folgenden Symbole werden in diesem Handbuch zur Anzeige von Sicherheitshinweisen verwendet. Lesen Sie die so gekennzeichneten Informationen durch, um die erforderlichen Maßnahmen zu ergreifen.
Anmerkung: Mit einer Anmerkung wird auf Informationen verwiesen, die Sie beachten sollten.
VORSICHT: Das Wort “Vorsicht” weist auf mögliche Schäden für Daten oder Ihre Ausrüstung hin. Sie sollten erst dann fortfahren, wenn Sie die durch dieses Wort gekennzeichneten Informationen gelesen und verstanden haben.
WARNUNG: Mit einer Warnung wird auf mögliche Gefahren für Ihre persönliche Sicherheit verwiesen.
Antes de comenzar (ESPAÑOL)
Los siguientes iconos se utilizan a lo largo de la guía con fines de seguridad. Se le aconseja leer, y entender en su totalidad, cualquier procedimiento marcado con estos iconos antes de proceder.
Sugerencia: Una sugerencia indica información adicional que puede serle de utilidad en la finalización de una tarea.
14 About this manual
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 15
PRECAUCIÓN: Una precaución indica la posibilidad de daños a los datos o equipo
. Se le aconseja no continuar más allá de una sección marcada con
este mensaje, a menos que entienda el procedimiento por completo.
ADVERTENCIA: Una advertencia indica la posibilidad de un riesgo a la seguridad personal.
Avant de commencer (FRANÇAIS)
Les icônes ci-dessous sont utilisées dans le manuel pour mettre en évidence des procédures de sécurité. Nous vous invitons à les lire et à bien comprendre toutes les procédures signalées par ces icônes avant de poursuivre.
Conseil : “Conseil” signale les informations complémentaires que vous pouvez trouver utiles pour mener à bien une tâche.
ATTENTION : “Attention” signale qu’il existe une possibilité d’endommager des données ou de l’équipement. Nous vous recommandons de ne pas poursuivre après une section comportant ce message avant que vous ayez pleinement assimilé la procédure.
AVERTISSEMENT : “Avertissement” signale une menace potentielle pour la sécurité personnelle.
Operazioni preliminari (ITALIANO)
Le seguenti icone vengono utilizzate nella guida a scopo cautelativo. Prima di procedere Vi viene richiesta un’attenta lettura di tutte le procedure, contrassegnate dalle suddette icone, affinché vengano applicate correttamente.
Suggerimento: “Suggerimento” fornisce indicazioni supplementari, comunque utili allo scopo.
ATTENZIONE: “Attenzione” indica il potenziale danneggiamento dei dati o delle attrezzature in dotazione. Vi raccomandiamo di non procedere con le operazioni, prima di aver ben letto e compreso la sezione contrassegnata da questo messaggio, onde evitare di compromettere il corretto svolgimento dell’operazione stessa.
PERICOLO: “Pericolo” indica l'eventuale pericolo di danno provocato alle persone, mettendo a rischio la vostra incolumità personale.
Vóór u aan de slag gaat (NEDERLANDS)
De volgende pictogrammen worden in de hele handleiding gebruikt in het belang van de veiligheid. We raden u aan alle procedure-informatie die door deze pictogrammen wordt gemarkeerd, aandachtig te lezen en ervoor te zorgen dat u de betreffende procedure goed begrijpt vóór u verder gaat.
About this manual 15
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 16
VOORZICHTIG: “V
oorzichtig” geeft aan dat er risico op schade aan data of apparatuur bestaat. We raden u aan even halt te houden bij de sectie die door dit woord wordt gemarkeerd, tot u de procedure volledig begrijpt.
WAARSCHUWING: Een waarschuwing wijst op een mogelijk gevaar voor de persoonlijke veiligheid.
Antes de começar (PORTUGUÊS)
Os ícones mostrados abaixo são utilizados ao longo do manual para assinalar assuntos relacionados como a segurança. Deverá ler e entender claramente todos os procedimentos marcados com estes ícones ande de prosseguir.
Sugestão: Uma sugestão assinala informações adicionais que lhe poderão ser úteis para executar uma tarefa.
CUIDADO: “Cuidado” indica que existe a possibilidade de serem causados danos aos dados ou ao equipamento. Não deverá avançar para lá de uma secção marcada por esta mensagem sem ter primeiro entendido totalmente o procedimento.
AVISO: Um aviso indica que existe um possível risco para a segurança pessoal.
Ennen kuin aloitat (SUOMI)
Seuraavilla kuvakkeilla kiinnitetään tässä oppaassa huomiota turvallisuusseikkoihin. Näillä kuvakkeilla merkityt menettelytavat tulee lukea ja ymmärtää ennen jatkamista.
Huomautus: Huomautus sisältää tietoja, jotka tulee ottaa huomioon.
VAROITUS: Varoitus varoittaa tietojen tai laitteiden vahingoittumisen
mahdollisuudesta. Tällä merkillä merkitystä kohdasta ei tule jatkaa eteenpäin ennen kuin täysin ymmärtää kuvatun menettelyn.
VAARA: Vaara varoittaa henkilövahingon mahdollisuudesta.
Innan du startar (SVENSKA)
Följande ikoner används i hela handboken för att markera säkerhetsaspekter. Läs igenom handboken ordentligt så att du förstår steg som har markerats med dessa ikoner innan du fortsätter.
Obs: “Obs” anger vad du ska observera.
FÖRSIKT: “Försikt” anger vad som kan leda till data eller utrustningsskador.
Fortsätt inte till nästa avsnitt innan du förstår det steg som har markerats med detta meddelande.
VARNING: “Varning” anger vad som kan leda till personskador.
16 About this manual
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 17

Related documentation

System Access Guide (MK
explains how to log in to the system, provides information about accessing the NAS server/cluster CLI and the SMU CLI, and provides information about the documentation, help, and search capabilities available in the system.
Server and Cluster Administration Guide (MK-92HNAS010)—In PDF format,
this guide provides information about administering servers, clusters, and server farms. Includes information about licensing, name spaces, upgrading firmware, monitoring servers and clusters, the backing up and restoring configurations.
Storage System User Administration Guide (MK-92HNAS013)—In PDF
format, this guide explains user management, including the different types of system administrator, their roles, and how to create and manage these users.
Network Administration Guide (MK-92HNAS008)—In PDF format, this
guide provides information about the server's network usage, and explains how to configure network interfaces, IP addressing, name and directory services.
File Services Administration Guide (MK-92HNAS006)—In PDF format, this
guide explains about file system formats, and provides information about creating and managing file systems, and enabling and configuring file services (file service protocols).
Data Migrator Administration Guide (MK-92HNAS005)—In PDF format, this
guide provides information about the Data Migrator feature, including how to set up migration policies and schedules.
Storage Subsystem Administration Guide (MK-92HNAS012)—In PDF
format, this guide provides information about managing the supported storage subsystems (RAID arrays) attached to the server/cluster. Includes information about tiered storage, storage pools, system drives (SDs), SD groups, and other storage device related configuration and management features and functions.
Snapshot Administration Guide (MK-92HNAS011)—In PDF format, this
guide provides information about configuring the server to take and manage snapshots.
Replication and Disaster Recovery Administration Guide (MK-92HNAS009)
—In PDF format, this guide provides information about replicating data using file-based replication and object-based replication, provides information on setting up replication policies and schedules, and using replication features for disaster recovery purposes.
Antivirus Administration Guide (MK-92HNAS004)—In PDF format, this
guide describes the supported antivirus engines, provides information about how to enable them, and how to configure the system to use them.
-92HNAS014)—In PDF format, this guide
About this manual 17
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 18
Backup Administration Guide (MK
-92HNAS007)—In PDF format, this guide provides information about configuring the server to work with NDMP, and making and managing NDMP backups. Also includes information about Hitachi NAS Synchronous Image Backup.
Command Line Reference—Opens in a browser, and describes the commands used to administer the system.
Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference (MK-92HNAS016)—Provides an overview of the second-generation server hardware, describes how to resolve any problems, and replace potentially faulty parts.
Hitachi NAS Platform 3080 and 3090 G2 Hardware Reference (MK-92HNAS017)—Provides an overview of the first-generation server hardware, describes how to resolve any problems, and replace potentially faulty parts.
Hitachi NAS Platform Series 4000 Hardware Reference (MK-92HNAS030)— Provides an overview of the Hitachi NAS Platform Series 4000 server hardware, describes how to resolve any problems, and how to replace potentially faulty components.
Release notes—provide the most up-to-date information about the system, including new feature summaries, upgrade instructions, and fixed and known defects.
Note: F
or a complete list of Hitachi NAS open source software copyrights and
licenses, see the System Access Guide.
18 About this manual
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 19
About this manual 19
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 20
2

Safety information

This section lists important safet equipment.
Electrostatic discharge precautions
Safety and handling precautions
Electrical precautions
Data protection precautions
y guidelines to follow when working with the
20 Safety information
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 21

Electrostatic discharge precautions

T
o ensure proper handling of system components and to prevent hardware
faults caused by electrostatic discharge, follow all safety precautions:
• Wear an anti-static wrist or ankle strap.
• Observe all standard electrostatic discharge precautions when handling plug-in modules or components that have been removed from any anti­static packaging.
Avoid contact with backplane components and module connectors.

Safety and handling precautions

To ensure your safety and the safe handling and correct operation of the equipment, follow all of the safety precautions and instructions.
Caution: Observ can weigh 56 lb. (25 kg) or more. At least two people are required to handle and position a server in a rack.
Caution: There is a risk that a cabinet could fall o this from occurring:
• If your system comes with a rack stabilizer plate, install it.
• Fill all expansion cabinets, including all storage enclosures, from the bottom to the top.
• Do not remove more than one unit from the rack at a time.
To help prevent serious injuries, load the components in the storage cabinet in the prescribed order:
1. If present, install the r
cabinet.
2. Load the Fibre Channel (FC) switches in the storage cabinet at the
positions recommended in the System Installation Guide. The positions can be adjusted according to a specific storage cabinet configuration.
3. Load and position the server(s) directly above the FC switches, if used in
your configuration.
4. The System Management Unit (SMU), if used in your configuration,
should be placed directly below the FC switches.
5. The first storage enclosure should be positioned at the bottom of the
storage cabinet. Additional enclosures are then placed above existing enclosures, going towards the top of the system cabinet.
6. Once the bottom half of the storage cabinet has been filled, the top half
of the storage cabinet can be filled. Begin by placing a storage component directly above the server and then fill upwards.
e safe lifting practices. Each server or each storage array
ver suddenly. To prevent
ack stabilizer plate to the front of the system
Safety information 21
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 22

Electrical precautions

T
o help ensure your safety and the safe handling of equipment, follow these
guidelines.
• Provide a suitable power source with electrical overload protection to meet the power requirements of the entire system (the server/cluster, and all storage subsystems and switches). The power requirements per cord are ­North America: 2 phase, 208Vac, 24A max; 1 phase 110Vac, 16A max. Europe: 230Vac, 16A max.
• Provide a power cord that is suitable for the country of installation (if a power cord is not supplied).
• Power cords supplied with this server or system may be less than 1.5m in length. These cords are for use with a power distribution unit (PDU) which is mounted inside the 19 inch rack. If you require longer cables, please contact your local sales representative.
• Provide a safe electrical ground connection to the power cord. Check the grounding of an enclosure before applying power.
• Only operate the equipment from nominal mains input voltages in the range 100 - 240Vac, 6A max, 50/60Hz.
Caution: T undertaking servicing of the system.
• Unplug a system component if it needs to be moved or if it is damaged.
Note: F external UPS to power the server. Also, each of the redundant power supplies in the server and in the storage subsystems should be operated from a different mains power circuit in order to provide a degree of protection from mains power supply failures. In the event that one circuit fails, the other continues to power the server and the storage subsystem.
urn off all power supplies or remove all power cords before
or additional data protection, Hitachi recommends that you use an

Data protection precautions

o help ensure the protection of data and safe handling of equipment, follow
T these guidelines.
• Each storage enclosure contains multiple removable hard disk drive (HDD) modules. These units are fragile. Handle them with care and keep them away from strong magnetic fields.
• All supplied plug-in modules and blanking plates must be in place to complete the internal circuitry and enable air to flow correctly around an enclosure.
22 Safety information
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 23
• Using the system for more than a few minutes with modules or blanking plates missing can cause an enclosure to o
verheat, leading to power
failure and data loss. Such use may invalidate the warranty.
• A loss of data can occur if a hard drive module is removed. Immediately replace any modules that are removed. If a module is faulty, replace it with one of the same type, of at least the same capacity and speed.
• Always shut down the system before it is moved, switched off, or reset.
• All storage enclosures are fitted with optical SFP transceivers. The transceivers that are approved for use with supported storage enclosures vary depending on the unit. The transceivers qualified for older systems might not be approved for use with the most current storage systems. To ensure proper operation of the server and the storage subsystems, use only the approved replacement parts for each system. Contact the Hitachi Data Systems Support Center for technical details about replacement parts.
• Maintain backup routines. Do not abandon backup routines. No system is completely foolproof.
Safety information 23
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 24
3

Mandatory regulations

The sections that follow outline the mandatory regulations go installation and operation of the system. Adhere to these instructions to ensure that regulatory compliance requirements are met.
International standards
Federal Communications Commission (FCC)
European Union (EU) Statement
Canadian Department of Communication Compliance Statement
Radio Protection for Germany
Food and Drug Administration (FDA)
Chinese RoHS Compliance Statement
verning the
24 Mandatory regulations
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 25

International standards

The equipment described in this manual complies with the requirements of the following agencies and standards.
Safet
y
• Worldwide: IEC60950-1: 2nd edition
• EU: EN60950-1: 2nd edition
• North America: UL60950-1: 2nd edition; CAN/CSA-C22.2 No.60950-1-07 2nd edition
EMC
• USA: FCC Part 15 Subpart B class A
• Canada: ICES-003 Issue No 4 class A
• EU: EN55022 class A; EN61000-3-2; EN61000-3-3; EN55024
• Australia & New Zealand: C-Tick – AS/NZS CISPR22 class A
• South Korea: KCC class A
• Japan: VCCI class A
Certification for the following approvals marks have been granted:
• European Union CE mark, including RoHS2
• China: CCC
• Russia: GOST-R
• Taiwan: BSMI
• Argentina: IRAM
• Australia & New Zealand: C-Tick
• Mexico: NOM and CONUEE
• South Africa: SABS (safety) and EMC (self-certification by CoC)

Federal Communications Commission (FCC)

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if it is not installed and used in accordance with the instruction manual, might cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the users will be required to correct the interference at their own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Neither the provider nor the manufacturer is
Mandatory regulations 25
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 26
responsible for any radio or television interference caused by using non­recommended cables and connectors, or b modifications to this equipment.
Unauthorized changes or modifications could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. The device can not cause harmful interference.
2. The device must accept any interference received, including interference
that might cause undesired operation.

European Union (EU) Statement

This product conforms to the protection requirements of the following EU Council Directives:
• 89/336/EEC Electromagnetic Compatibility Directive
• 73/23/EEC Low Voltage Directive
• 93/68/EEC CE Marking Directive
• 2002/95/EC Restriction in the use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) - This product is 6/6 (fully) compliant.
y unauthorized changes or
The manufacturer cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product.
This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to European Standard EN
55022. The limits for Class A equipment were derived for commercial and
industrial environments to provide reasonable protection against interference with licensed communication equipment.
Caution: This is a Class A product and as such, in a domestic en might cause radio interference.
vironment,

Canadian Department of Communication Compliance Statement

This Class A digital appar Interference - Causing Equipment Regulations.
atus meets all the requirements of the Canadian
26 Mandatory regulations
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 27

Avis de conformité aux normes du ministère des Communications du Canada

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Radio Protection for Germany

Dieses Gerät erfüllt die Bedingungen der EN 55022 Klasse A.

Food and Drug Administration (FDA)

The product complies with FDA 21 CFR 1040.10 and 1040.11 regulations, which go
vern the safe use of lasers.

Chinese RoHS Compliance Statement

Mandatory regulations 27
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 28
28 Mandatory regulations
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 29
Mandatory regulations 29
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 30
4

System overview

This chapter describes the components in the system for the following models:
• Hitachi NAS Platform, Model 3080
• Hitachi NAS Platform, Model 3090
System components
Server specifications
Attaching a rack stabilizer plate
Hitachi NAS Platform server
30 System overview
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 31

System components

The system contains man
y components and is housed in a rack or cabinet.
This section describes the main system components.
Component Description
Hitachi NAS Platform Hitachi Unified Storage File Module server
System management unit (SMU)
or
The system can contain a single server or several servers that operate as a cluster. Clusters that use more than two servers include two 10 Gbps Ethernet switches. Hitachi Data Systems supports two switches for redundancy.
For information about the physical configuration of a cluster configuration, see the Hitachi Unified Storage File Module and Hitachi NAS Platform System Installation Guide.
Note: F
external UPS to power the server. Also, each of the redundant power supplies in the server and in the storage subsystems should be operated from a different mains power circuit in order to provide a degree of protection from mains power supply failures. In the event that one circuit fails, the other will continue to power the server and the storage subsystem.
A standalone server can operate without an external SMU, but all of the cluster configur
The SMU is the management component for the other components in a system. An SMU provides administration and monitoring tools. It supports data migration and replication, and acts as a quorum device in a cluster configuration. Although integral to the system, the SMU does not move data between the network client and the servers.
ations require an external SMU.
or additional data protection, it is recommended to use an
Storage subsystems
Fibre Channel (FC) switches
External Fast Ethernet (10/100) or Gigabit Ethernet (GigE) switches
In a single-server configuration, typically an embedded SMU manages the system. In clustered systems and some single-node systems, an external SMU provides the management functionality. In some cases, multiple SMUs are advisable.
A Hitachi NAS Platform or Hitachi Unified Storage File Module system can control several storage enclosures. The maximum number of storage enclosures in a rack depends on the model of storage enclosures being installed. Refer to the Storage Subsystem Administration Guide for more information on supported storage subsystems.
The server supports FC switches that connect multiple servers and storage subsystems.
Contact Hitachi Data Systems Support Center for information about which FC switches are supported.
A standalone server can operate without an external Ethernet switch, provided that it uses an embedded SMU and there are less than three RAID subsystems attached.
A standalone server requires an external Ethernet switch if there are more than two RAID subsystems attached or if there are two RAID subsystems attached and an external SMU is used.
System overview 31
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 32
Component Description
10 Gigabit Ethernet (10 GbE) switches

Server specifications

All cluster configurations require an external Ethernet switch.
Used in cluster configurations only.
er connects to a 10 GbE switch for connection with the public data
A serv network (customer data network).
A 10 GbE switch is required for internal cluster communications for clusters of three or more nodes.
Contact Hitachi Data Systems Support Center for information about the 10 GbE switches that have been qualified for use with the server, and to find out about the availability of those switches.
Hitachi Data Systems requires dual 10 GbE switches for redundancy. In a dual­switch configuration, if one switch fails, the cluster nodes remain connected through the second switch.
The following specifications are for the serv
er. Except for the power and cooling values, these specifications do not reflect differences among models; they are the maximum for all server models. For more detailed specifications of a particular model or configuration, contact your representative.
Physical:
• Weight: 25 kg (55 lb.)
• Height: 132 mm. (5.2 in.)
• Depth (including handles and bezel): 685 mm. (27 in.)
• Width: 440 mm. (17.3 in.)
• Rack space required: 3U (5.25 in.)
Note: A r
ack unit, or U, is a unit of measure that is used to describe the height of equipment intended to be mounted in a rack. One rack unit is equivalent to 1.75 inches or 44.45 millimeters.
Power and cooling:
Note: The power supplies and cooling fans noted in the following table are hot
-swappable.
Item Models 3080 G2 and 3090 G2
Power supplies 2
Cooling fans 2
Voltage range
32 System overview
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
110 VAC: 2.3A to 2.8A
AC: 1.2A to 1.5A
208 V
Page 33
Item Models 3080 G2 and 3090 G2
230 VAC: 1.1A to 1.4A
Power supply rating 450W
Average thermal (BTU per hour) 853
Max thermal (BTU per hour) 1057
Max power usage 310W
Other thermal:
Temperature range (operational): 10° to 35° C (50° to 95° F)
• Maximum rate of temperature change per hour (operational) 10° C (18° F)
• Temperature range (storage): -10° to 45° C (14° to 113° F)
• Maximum rate of temperature change per hour (storage) 15° C (27° F)
• Temperature range (transit): -20° to 60° C (-4° to 140° F)
• Maximum rate of temperature change per hour (transit) 20° C (36° F)
Humidity:
• Operational: 20-80%
• Storage: 10-90%
• Transit: 5-95%
Noise: A-weighted Sound Power Level, Lwa (db re 1pW):
• Typical: 71
• Max: 81
Shock and vibration:
• Optional random vibration: 10 to 350 Hz @ 0.18 Grms
• Non-operational sinusoidal vibration: 60 to 350 Hz: @ 1g
• Non-operational shock: 3g 11ms, half sine
Packaged transport specification:
• Drops from 356mm and 508mm as per ASTM D5276
• Vibration at up to 0.53 Grms as per ASTM D4728
Altitude:
• Maximum of 2000 meters
Approvals:
Europe: CE, RoHS (6) & WEEE compliant
• EMC: EN55022, FCC & VCCI, all class A. EN55024
• Safety: CSA/UL 60950-1, EN60950-1
System overview 33
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 34

Attaching a rack stabilizer plate

A r
ack stabilizer plate and mounting hardware are supplied with some system configurations. Hitachi Data Systems recommends that you always use the stabilizer plate when provided. Use of a stabilizer plate is required for those installations with dense trays.
The stabilizer contains two holes for securing it to the ground. Use suitable screws to secure the stabilizer.
Note: A
Procedure
1. Place the stabiliz
2. Align the holes from the stabilizer plate to the holes on the bottom of the
3. Place the screws in the holes and secure them into the cabinet.
ttach the stabilizer plate to the rack before loading the cabinet.
er plate up against the bottom of the front side of the
cabinet.
cabinet.
34 System overview
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 35
System overview 35
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 36
5
Hitachi NAS Platform server
components
This section describes the components included in the serv
A Hitachi Unified Storage File Module system can contain single Hitachi NAS Platform server or several servers that operate as a cluster. Clusters of more than two servers include two 10 Gbps Ethernet switches. Hitachi Data Systems only requires two switches for redundancy.
For information about the physical configuration of a cluster configuration, see the Hitachi NAS Platform and Hitachi Unified Storage File Module System Installation Guide.
The Hitachi NAS Platform server chassis consists of
• A removable fascia
• MMB (Mercury Motherboard)
• MFB (Mercury FPGA Board)
• Two hot-swappable fan assemblies
• Dual power supplies
• NVRAM backup battery pack
• Dual hot-swappable 2.5 inch disk drives
• Two PCI slots, two PCI-e x16 slots, and two PCI-X slots (not used at this
time)
er chassis.
Ventilation
Server front panel
LED status indicators
NVRAM backup battery pack
Hard disk drives
Fans

36 Hitachi NAS Platform server components

Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 37
Server rear panel
Rear panel server LED and button locations
Management interfaces
Ethernet cables
Hitachi NAS Platform server components 37
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 38

Ventilation

There are v These openings are designed to allow airflow, which prevents the server from overheating.
Note: A server rack so that airflow is unrestricted.
Caution: Do not place the server in a built-in installation unless proper ventilation is provided.
Do not operate the server in a cabinet whose internal ambient temperature exceeds 35º C (95º F).
ents and fan openings on the front and the rear of the server.
t least four inches of clearance must be present at the rear of the

Server front panel

The front of the serv facing server components.
er features a removable bezel that shields the front-
Once the bezel is removed, the front-facing components on the server
chassis are visible.
Figure 5-1 Server front panel bezel
38 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 39
Figure 5-2 Server model 3080 and 3090 front panel components (bezel
removed)
Table 5-1 Server front panel component descriptions
Item Description
1 NVRAM battery backup pack
2 Hard disk drive A (top)
3 Hard disk drive B (bottom)
4 Disk B status LED
5 Disk A status LED
6 Fan 1
7 Fan 2
8 Power status LED
9 Server status LED
10 NVRAM battery backup pack status LED
11 Fan 1 status LED
12 Fan 2 status LED

LED status indicators

The LEDs (light emitting diodes) on the front of the chassis indicate the o
verall status of the server, as well as the status of some of the individual components. The NVRAM backup battery pack, each of the hard disk drives, and each of the fan assemblies has a status LED.
Hitachi NAS Platform server components 39
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 40
Figure 5-3 Model 3080 and 3090 status LEDs
Table 5-2 LED descriptions
LEDs Meaning
1 Hard disk drive A status LED
2 Hard disk drive B status LED
3 NVRAM battery backup pack status LED
4 Fan 1 status LED
5 Fan 2 status LED
6 Power status LED
7 Server status LED
Table 5-3 Power status LED (green)
LEDs Meaning
Green Normal operation with a single server or an active cluster node in operation.
Slow flash (once
ery three
ev
seconds)
Medium flash
(once every .8
seconds)
Fast flash (five
flashes per
second)
Off The server is not powered up.
The system has been shut down.
The server is available to host file services but is not currently doing so. Also if no EVS is configured or all EVSs are running on the other node in a cluster.
The server is rebooting.
40 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 41
Table 5-4 Server status LED (amber)
LEDs Meaning
Amber Critical failure and the server is not operational.
Slow flash (once
ery three
ev
seconds)
Medium flash
(once every .8
seconds)
Off Normal operation.
System shutdown has failed. Flashes once every three seconds.
The server needs attention, and a non-critical failure has been detected, for example, a fan or power supply has failed.
Table 5-5 Battery pack status LED
LEDs Meaning
Red
Off
LEDs Meaning
Red
Off
If this LED is on immediately after installing a new battery pack, it indicates that an initial battery charging and conditioning cy battery conditioning takes approximately 24 hours, and the LED will turn off after the cycle is complete.
If this LED is on during normal operation (not after installing a new battery pack), either the battery has exceeded its two year life or a problem has been detected. Check the battery status before determining any service operation.
Normal operation.
Fan has failed, fan speed is out of acceptable range, or fan speed is not being reported. (This LED will be on if the corresponding fan has been remo
When on, this LED indicates a failure and that the fan is not operating correctly. Replace the fan as soon as possible.
Normal operation.
Table 5-7 Hard disk activity and status LEDs
LEDs Meaning
cle is in progress. The initial
Table 5-6 Fan status LEDs
ved.)
Blue
Red
If this LED is on and blue, the disk is operating normally and no problems have been detected. If the LED is flashing blue, it indicates disk activit on, but not flashing, there is currently no disk activity.
If this LED is on immediately after installing a new hard disk, it indicates that the RAID configuration for the server is being rebuilt. The LED will turn off after the RAID configuration is restored. The amount of time it takes for the RAID configuration to be rebuilt after a new disk drive is installed depends on the amount of user and system configuration data stored.
Hitachi NAS Platform server components 41
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
y. If the LED is
Page 42
LEDs Meaning
If this LED is on during the course of normal operation (not after installing a new hard disk), either the disk has failed or the serv been degraded.

NVRAM backup battery pack

er’s RAID configuration has
Each serv
er contains a battery pack. The battery pack maintains the NVRAM contents when the server is not receiving power (due to a power failure or a short-term shut down). The battery pack is located behind the front bezel cover of the server, on the left-hand side. The battery pack is hot-swappable and can only be accessed after the front bezel has been removed.
Figure 5-4 Model 3080 and 3090 NVRAM backup battery pack (front view)
Figure 5-5 NVRAM battery backup pack location behind bezel
Battery pack char
acteristics:
• Each server contains a single battery module. The module contains dual
redundancy inside.
• The battery pack uses NiMH technology.
• A battery pack has a two year operational life. A timer starts when a
server is booted for the first time, and the timer is manually restarted when a replacement batter pack is installed. After two years of operation, a log warning event is issued to warn the user that the battery pack should be replaced.
• The battery pack is periodically tested to ensure it is operational.
• A fully charged battery pack maintains the NVRAM contents for
approximately 72 hours.
42 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 43
• When a new server is installed and powered on, the battery pack is not
fully charged (it will not be at 100% capacit
y). After being powered on, the server performs tests and starts a conditioning cycle, which may take up to 24 hours to complete. During the conditioning cycle, the full NVRAM content backup protection time of 72 hours cannot be guaranteed.
• A replacement battery pack may not be fully charged (it may not be at 100% capacity) when it is installed. After a new battery pack is installed, the server performs tests and starts a conditioning cycle, which may take up to 24 hours. During the conditioning cycle, the full NVRAM content backup protection time of 72 hours cannot be guaranteed.
• If a server is left powered off, the battery will discharge slowly. This means that, when the server is powered up, the battery will take up to a certain number of hours to reach full capacity and the time depends upon whether a conditioning cycle is started. The scenarios are:
24 hours if a conditioning cycle is started3 hours if a conditioning cycle is not started
During the time it takes for the battery pack to become fully charged, the full 72 hours of NVRAM content protection cannot be guaranteed. The actual amount of time that the NVRAM content is protected depends on the charge level of the battery pack.
• A battery pack may become fully discharged because of improper shutdown, a power outage that lasts longer than 72 hours, or if a server is left unpowered for a long period of time.
If the battery pack is fully discharged:
The battery pack may permanently lose some long term capacity.Assuming a battery conditioning cycle is not started, a fully discharged
battery pack takes up to 3 hours before it is fully charged. If a battery conditioning cycle is started, a fully discharged battery pack takes up to 24 hours before it is fully charged.
A battery conditioning cycle is started if the server is powered down for
longer than three months.
• A battery pack may be stored outside of the server for up to one year before it must be charged and/or conditioned. After one year without being charged and possibly conditioned, the battery capacity may be permanently reduced.
If you store battery packs for more than one year, contact your representative to find out about conditioning your battery packs.
• When preparing a server for shipment, if the NVRAM is still being backed up by battery (indicated by the flashing NVRAM LED), the battery can be manually isolated using the reset button. See
Reset button (RST) on page
50 for the location of the reset button.
When preparing a serv
er for shipment or if it will be powered down for any length of time, it is important that the server has been shut down correctly before powering-off. Otherwise, if the server is improperly shut down, the batteries supplying the NVRAM will become fully discharged. This also
Hitachi NAS Platform server components 43
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 44
occurs if the system is powered down for too long without following the proper shutdown procedure.
Note: If the batteries become fully discharged, or the system is to be powered down for an extended period, see Powering down the server for
shipment or storage on page 85. Contact
Center for information about recharging batteries.
To replace the NVRAM battery backup pack, see Replacing the NVRAM
backup battery pack on page 64.

Hard disk drives

Hitachi Data Systems Support
The serv
er contains two hard disks, which are configured as a Linux SW RAID 1 pair, and they store server or cluster-related data. These hard disks are not part of the customer-usable data storage that is available to the server.
Hard disks are located behind the bezel on the left side of the chassis.
Note: F
ailed hard disks are hot-swappable, so a failed hard disk can be replaced without shutting down the server. However, there are serious risks in trying to swap a drive that is not failed.
Figure 5-6 Hard disk drives status and activity status LEDs - models 3080
and 3090
Item Description
1 Disk A status and activity LEDs
2 Disk B status and activity LEDs
Table 5-8 Hard disk activity and status LEDs
LEDs Meaning
Blue
44 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
If this LED is on and blue, the disk is operating normally and no problems have been detected. If the LED is flashing blue, it indicates disk activit on, but not flashing, there is currently no disk activity.
y. If the LED is
Page 45
LEDs Meaning

Fans

Red
The serv
er features dual hot-swappable fan assemblies. The fans provide for
If this LED is on immediately after installing a new hard disk, it indicates that the RAID configur the RAID configuration is restored. The amount of time it takes for the RAID configuration to be rebuilt after a new disk drive is installed depends on the amount of user and system configuration data stored.
If this LED is on during the course of normal operation (not after installing a new hard disk), either the disk has failed or the server’s RAID configuration has been degraded.
ation for the server is being rebuilt. The LED will turn off after
front-to-back airflow to be consistent with other storage system components.
The server’s cooling airflow enables the system to operate in an ambient temperature range of 10°C to 35°C when mounted in a rack or cabinet with associated components required to make up a storage system. The storage system administrator is responsible for ensuring that the ambient temperature within the rack does not exceed the 35°C operating limit.
The server continues to operate following the failure of a single fan and during the temporary removal of a fan for replacement. Replace a failed fan as soon as possible.
Caution: If a fan has failed, replace the fan as soon as possible to reduce the amount of time the serv
er is operating with reduced airflow.
The fans are contained within two assemblies, each containing a single v
ariable-speed fan. Fan assemblies are located behind the front bezel. Each fan assembly is secured to the chassis with two thumbscrews and a blind­mate electrical connector; no tools are required to remove or install a fan assembly.
Two fan status LEDs provide fan status information. These LEDs are located behind the bezel on the right side of the chassis.
Hitachi NAS Platform server components 45
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 46
Figure 5-7 Fan and fan status LED locations - models 3080 and 3090
Item Description
1 Fan 1 (left)
2 Fan 2 (right)
3 Fan 1 status LED
4 Fan 2 status LED
Table 5-9 Fan status LEDs
LEDs Meaning
Red
Off

Server rear panel

The rear panel of the serv and LEDs.
Fan has failed, fan speed is out of acceptable range, or fan speed is not being reported. (This LED will be on if the corresponding fan has been remo
When on, this LED indicates a failure and that the fan is not operating correctly. Replace the fan as soon as possible.
Normal operation.
ved.)
er features numerous ports, connectors, switches,
46 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 47
Figure 5-8 Server rear panel components - models HNAS 3080 and HNAS
3090
Note: Ex
cept for the ports and connectors described in the following, none of the other ports or connectors should be used without guidance from technical support.
Table 5-10 Server rear panel components descriptions
Item Connectivity Quantity Description
1 Clustering ports 10 GbE 2
2 10 GbE network ports 2 Connection to external 10 Gbps Ethernet
3 Gigabit Ethernet network ports 6 Connection to external Ethernet data
4 10/100 Ethernet port 5 Connection to private management network.
5 Storage or FC switch 4 Connection to disk arrays or (where present)
6 n/a 3 Status LEDs (NVRAM, power, and server),
7 Power supply units:
PSU 1
PSU 2
8 I/O ports 2 Keyboard (purple) and mouse (green) ports.
2 Connect to the rack's Fault group:
For cluster management and heartbeat, connect to:
Two way configuration: Connect to
• corresponding cluster server ports (left port to left port and right port to right port).
• N-way configuration: Connect to 10 GbE switch.
data network.
network.
to the FC switches.
and Power and Reset buttons.
• PSU 1 to Fault group A
• PSU 2 to Fault group B
(Reserved for Customer Service Engineer access only.)
Hitachi NAS Platform server components 47
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 48
Item Connectivity Quantity Description
9 I/O ports 2 USB port. (Reserved for Customer Service
Engineer access only.)
10 RS-232 1 Management interface. (Reserved for
Customer Service Engineer access only.)
11 Video port 1 Video management interface port. (Reserved
for Customer Service Engineer access only.)
12 ETH0 1000baseT Ethernet
ay logo)
(gr
13 ETH1 1000baseT Ethernet
(yellow logo)
1 External system management. Connect to
the customer's management switch.
1 Management port. Connect to the rack's
internal Ethernet switch.

Rear panel server LED and button locations

The rear panel of the serv
er contains three (3) status LEDs that indicate server status and two (2) buttons that are used to power up and reset the server.
Figure 5-9 Rear panel server LEDs and buttons
Item Meaning
1 NVRAM battery backup status LED
2 Power status symbol and LED
3 Server status LED
4 Reset button
5 Power button

Rear panel LED state descriptions

The NVRAM, power powered, its operational state, and whether the NVRAM is currently being protected by battery backup power. The way an LED flashes provides further information about what is currently occurring.
48 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
, and server status LEDs indicate whether the server is
Page 49
Table 5-11 NVRAM status LED (green/amber)
State Meaning
Green (solid)
Green (flashing)
Amber (solid)
Off Disabled or NVRAM battery power exhausted
Normal operation
NVRAM contents are protected by battery power
Battery pack is faulty or not fitted
Table 5-12 Power status LED (green)
LEDs Meaning
Green Normal operation with a single server or an active cluster node in operation.
Slow flash (once
ery three
ev seconds)
Medium flash (once every .8 seconds)
Fast flash (five flashes per second)
The system has been shut down.
The server is available to host file services but is not currently doing so. Also if no EVS is configured or all EVSs are running on the other node in a cluster.
The server is rebooting.
Off The server is not powered up.
LEDs Meaning
Amber Critical failure and the server is not operational.
Slow flash (once
ery three
ev seconds)
Medium flash (once every .8 seconds)
Off Normal operation.

Power button (PWR)

Under normal circumstances, the power button is r power button can be used to restore power to the system when the server is in a standby power state.
Table 5-13 Server status LED (amber)
System shutdown has failed. Flashes once every three seconds.
The server needs attention, and a non-critical failure has been detected, for example, a fan or power supply has failed. Flashes once every .8 seconds.
arely used. However, the
Hitachi NAS Platform server components 49
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 50
When power cables are connected to the PSUs, the server normally powers up immediately but the Power Status LED is not lit, press the PWR button to restore power to the system. Open a case with the Hitachi Data Systems Support Center to get the problem resolved.
. If, after 10 seconds, the LEDs on the power supplies are lit,
Note: Do not use the power button during normal oper Pressing the power button immediately causes an improper shutdown of the system. The PSUs will continue to run.

Reset button (RST)

The reset button has sev
• Pressing the reset button when the server is powered on causes a hard
reset of the server. This reset occurs after a 30-second delay, during which the server status
LED flashes rapidly and the server attempts to shut down properly. Even with the delay, pressing the reset button does not guarantee a complete shutdown before rebooting. Only press the reset button when the server is powered on to recover a server which has become unresponsive. Pressing the reset button at this time may produce a dump automatically.
• Pressing the reset button for more than five seconds when the server is
not powered up disables the NVRAM battery pack (which may be necessary prior to shipping if an incomplete shutdown occurred.) See
Powering down the server for shipment or storage on page 85
information.
ation of the server.
eral functions.
for more
Caution: If the serv
server on page 83. Do not pull the power cord. Pulling the power cord does
not produce a dump
er is non-responsive, see
.

Fibre channel storage ports

The Fibre Channel (FC) stor other FC devices, such as storage subsystems.
FC ports operate at speeds of two to eight (8) gigabits per second. FC ports use an enhanced small form factor pluggable (SFP+) optical connector.
The SFP+ ports can be removed from the chassis.
Note: When remo ports are indistinguishable from one another except for their part numbers. The part number is located on the side of the port housing and is only visible when the port is removed. Part number prefixes are different as follows:
• 10 GbE: FTLX<number>
• FC: FTLF<number>
ved, the 10 GbE and 8 GB Fibre Channel (FC) SFP+ storage
Restarting an unresponsive
age ports allow you to connect the server with
50 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 51
Figure 5-10 Fibre Channel storage ports label
Status/Activity (per port) Meaning
Status Green
(on, not flashing)
Green off No link
Activity Amber flashing Data activity
Amber off No data activity

10/100 private Ethernet ports

The 10/100 Priv for the private management network (refer to the Network Administration Guide for more information on the private management network). These ports are used by the server and other devices (such as an external SMU and other cluster nodes) to form the private management network. There are no internal connections to the server from these ports; instead, when joining a server to the private management network, you must connect from one of these ports to the management interface port on the server.
The 10/100 ports operate at speeds of up to 100 megabits per second, and require the use of a standard RJ45 cable connector.
The 10/100 Private Management Ethernet Network ports are labeled as shown next:
ate Ethernet Network ports function as an unmanaged switch
FC link present
Figure 5-11 10/100 Private Management Network Ethernet Ports Label
Once connected, each 10/100 port has two indicator LEDs; one green and one amber
. These LEDs provide link status and network activity status
information as follows:
Status/Activity (Per Port) Meaning
Status Green
(On, not flashing)
Green Off No link
Activity Amber Flashing Network activity
Amber Off No network activity
10 or 100 Mbps link present
Hitachi NAS Platform server components 51
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 52

GE Ethernet network ports

The GE Ethernet Network ports are used to connect the serv
er or cluster node to the customer’s data network (also called the public network), and these ports may be aggregated into a single logical port (refer to the Network Administration Guide for more information on creating aggregations). GE ports operate at speeds of up to one (1) gigabit per second, and require the use of a standard RJ45 cable connector.
The GE Customer Ethernet Network ports are labeled as shown next:
Figure 5-12 GE Customer Ethernet Network Ports Label
Once connected, each GE port has two indicator LEDs; one green and one amber
. These LEDs provide link status and network activity status
information as follows:
Status/Activity (Per Port) Meaning
Status Green
(On, not flashing)
Green Flashing 1 Gbps link standby in a redundant configuration
1 Gbps link present
Green Off No link
Activity Amber Flashing Network activity
Amber Off No network activity

10 GbE Ports

Figure 5-13 NAS Platform 10 GbE Ports
10 Gigabit Ethernet cluster interconnect ports
The 10 gigabit per second Ethernet (10 GbE) cluster ports allow y connect cluster nodes together. The cluster ports are used only in a cluster configuration. The 10 GbE ports operate at speeds of ten (10) gigabits per second.
ou to
52 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 53
Do
not use the 10 GbE cluster interconnect ports to connect to the customer
data network (also known as the public data network).
Figure 5-14 10 GbE cluster interconnect ports label
Once connected, each 10 GbE port has two indicator LEDs; one green and one amber
. These LEDs provide link status and network activity status
information as follows:
Status/Activity (per port) Meaning
Status Green
(on, not flashing)
Green flashing 10 Gbps link standby in a redundant configuration
Green off No link
Activity Amber flashing Network activity
Amber off No network activity
10 Gbps link present
10 Gigabit Ethernet customer data network ports
The 10 Gigabit Ethernet (GbE) customer data network ports are used to connect the server or cluster node to the customer’s data network (also called the public data network). These ports may be aggregated into a 1, 2, 3, or 4 aggregated port.
See the Network Administration Guide for more information on creating aggregations.
The 10 GbE ports operate at speeds of ten (10) gigabits per second. The 10 GbE ports use enhanced small form factor pluggable (SFP+) optical connectors.
Note: The 10 GbE customer data network ports cannot be used to interconnect cluster nodes.
Figure 5-15 10 GbE customer data network ports label
Once connected, each 10 GbE port has two indicator LEDs; one green and one amber
. These LEDs provide link status and network activity status
information as follows:
Hitachi NAS Platform server components 53
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 54
Status/Activity (per port) Meaning
Status Green
Activity Amber flashing Network activity

Power supply units

The serv (PSUs). The PSUs are accessible from the rear of the server.
The server monitors the operational status of the power supply modules so that the management interfaces can indicate the physical location of the failed PSU. LED indicators provide PSU status information for the state of the PSU.
er has dual, hot-swappable, load sharing, AC power supply units
10 GbE network link present
(on, not flashing)
Green off No link
Amber off No network activity
Figure 5-16 Power supply unit details
Item Description
1 PSU fan exhaust
2 Power cord connector
3 PSU retention latch
4 PSU handle
5 DC power status LED
6 PSU status LED
7 AC power status LED
54 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 55
Note: There are no field-serviceable parts in the PSU any reason, replace it. See information about replacing a power supply
Replacing a power supply unit on page 71 for
.
. If a PSU unit fails for
Table 5-14 DC power status LED (green)
Status Meaning
Green DC output operating normally
Off DC output not operating
If the DC Power status LED is off, unplug the power cable, wait 10 seconds, then reconnect the cable. If the DC P
ower Status LED remains off, the PSU
has failed and must be replaced.
Table 5-15 PSU status LED (amber)
Status Meaning
Off PSU operating normally
Amber PSU internal failure (over temperature, fan, or internal component)
If the PSU status LED is on, unplug the power cable, wait 10 minutes, then reconnect the cable. If the PSU Status LED remains off and must be replaced. See
Replacing a power supply unit on page 71
, the PSU has failed
for
more information on replacing a PSU.
Table 5-16 AC power status LED (green/amber)
Status Meaning
Green Receiving AC power and operating normally
Off Not receiving AC power (check mains and power cable connections)
Mains power connections are an IEC inlet in each power supply. Each PSU is only powered from its mains inlet. T
wo power feeds are required for the system. PSU units do not have an on/off switch. To turn on power, simply connect the power cable. To turn off the unit, remove the power cable.
When both PSUs are installed, if only one PSU is connected and receiving adequate power, the fans on both PSUs will operate, but only the PSU receiving power will provide power to the server.
Each power supply auto-ranges over an input range of 100V to 240V AC, 50 Hz to 60 Hz.
Caution: If the serv
er is non-responsive, see
Restarting an unresponsive
server on page 83. Do not pull the power cord.
Hitachi NAS Platform server components 55
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 56

Ethernet management ports 0 and 1

Serial port

USB ports

Standard 10/100/1000 Ethernet ports, used to connect to the serv management purposes.
A standard serial (RS-232) port, used to connect to the server for management purposes. See for more information.
Standard USB 2.0 (Univ used to connect USB devices to the server during some operations.
Valid USB devices include:
• Flash drives
• External hard drives
• USB keyboards
Valid operations include:
• Management
• Install
• Upgrade
• Update
• Repair
RS-232 serial management port on page 57
ersal Serial Bus 2.0) connectors. These ports are
er for
Note: The USB ports should not be used without guidance from Systems Support Center.

Management interfaces

The serv Serial (DB-9) and 10/100/1000 Ethernet (RJ45).
er panel features two types of physical management ports: RS-232
Hitachi Data
56 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 57
Figure 5-17 Management interface ports on rear panel - models 3080 and
Item Description
1 Serial management port (RS-232 DB-9 connector)
2 Ethernet management port 0 for customer facing management (RJ45 connector)
3 Ethernet management port 1 for private management (RJ45 connector)

RS-232 serial management port

The serv server. This serial port is intended to be used during system setup. The serial port is not intended as a permanent management connection. This port should not be used as the primary management interface for the server. The primary management interface to the server is through the Web Manager GUI or through server's command line interface (CLI), which can be accessed through the network.
Any VT100 terminal emulation interface can be used to access to the CLI so that you can perform management or configuration functions. Connect the terminal to the serial port on the rear panel of the server, then set the host settings to the values shown in the following table to ensure proper communication between the terminal and the server.
er has one RS-232 connection port, located on the rear panel of the
3090
Table 5-17 Host setting values
Terminal Requirement
Connection Crossover (null modem) cable
Emulation VT100
Baud rate 115,200 Bps
Data bits 8
Stop bits 1
Hitachi NAS Platform server components 57
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 58
Terminal Requirement
Parity None
Flow control None
Note: Once the initial setup has been completed, disconnect the serial cable. If y
ou need to manage the server through a serial connection, connect to the serial port on the external SMU and use SSH to access the server's CLI. If your system does not include an external SMU, connect to the server’s internal SMU and use SSH to access the server's CLI.

10/100/1000 Ethernet management ports

The 10/100/1000 Ethernet management ports are used to connect the serv or node to the customer facing management network and the private management network, or to connect directly to another device for management purposes.
The 10/100/1000 Ethernet ports operate at speeds of up to one (1) gigabit per second, and require the use of a standard RJ45 cable connector. Once connected, each GE port has two indicator LEDs; one on the top left and the second on the top right of the port. These LEDs provide link status and network activity status information as described in the next table:
er

Ethernet cables

The HNAS 3080 and 3090 models require CAT6 cables that fully comply with the CAT6 SF/UTP standard for the 1000Base-T GE Ethernet network ports. Always use CAT6 cables that fully comply, such as those supplied by Harting.
See the following examples of Harting cables that comply with the standard:
Cable Part number
CABLE ETHERNET PATCH LEAD CAT6 SF/UTP 1 Meter HARTING 09474747109
CABLE ETHERNET PATCH LEAD CAT6 SF/UTP 2 Meter HARTING 09474747111
CABLE ETHERNET PATCH LEAD CAT6 SF/UTP 3 Meter HARTING 09474747113
CABLE ETHERNET PATCH LEAD CAT6 SF/UTP 5 Meter HARTING 09474747115
CABLE ETHERNET PATCH LEAD CAT6 SF/UTP 10 Meter HARTING 09474747121
58 Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 59
Hitachi NAS Platform server components 59
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 60
6

Replacing server components

This section describes which components are field replaceable units (FRUs) and how to replace those components. The section also describes which components are hot
Field-replaceable units
Hot-swappable components
Removing and replacing the front bezel
Replacing a fan
Replacing the NVRAM backup battery pack
-swappable.
Replacing a hard disk
Replacing a power supply unit
Replacing an FPGA board as a FRU
60 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 61

Field-replaceable units

Some components are field-replaceable units (FRUs).
Important: The FRUs can only be replaced b components are not customer replaceable units (CRUs).
FRUs include the following components:
• Hitachi NAS Platform or Hitachi Unified Storage File Module servers
• Bezels
• Hard disk drives (HDDs)
• Power supply unit (PSUs)
• NVRAM battery backup packs
• Fan assemblies
Note: Main Motherboards (MMBs) and Main FPGA Boards (MFBs) are pre­installed boards that perform functions essential to the integrit If there is an issue with the MMB, or the MFB (typically), you must return the server for repair. MMBs are not FRUs, and, typically, MFBs are also not FRUs. However, an MFB may be replaced under certain specific circumstances. Contact Hitachi Data Systems Support Center to determine whether your MFB can be replaced as a FRU.
Some components are also hot-swappable. See Hot-swappable components
on page 61
for details.
y certified engineers. These
y of the server.

Hot-swappable components

Some components are hot-swappable. Such components can be changed without shutting down the server.
Before replacing a component that is not hot-swappable, you must shut down and power off the server. See
for details.
81
The HNAS 3080 and 3090 models includes the following hot-swappable components:
• HDDs
• PSUs
• NVRAM battery backup packs
• Fan assemblies
Rebooting or shutting down a server on page
Replacing server components 61
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 62

Removing and replacing the front bezel

T
o access some server components, or field replaceable units (FRUs), you must first remove the front bezel. Replace the bezel after the part replacement is complete.

Bezel removal

The server bezel is held onto the server chassis through a friction fit onto four retention posts, which are mounted to the chassis along the left and right edges of the chassis. There are no screws or other fasteners.
There are four (4) retention screws that hold the bezel retention posts onto the chassis.
Procedure
1. To remove the bezel, grasp the front of the bezel by the grasping areas.
2. Gently pull the bezel straight out away from the server.

Bezel replacement

Procedure
1. Place the bezel on the server, making sure that the bezel fits inside the
outer edges of the chassis and that the retention posts and status LEDs are aligned.
2. Using the solid portions of bezel (near the edges), press the bezel
straight into the server until it is firmly in place against the server chassis.

Replacing a fan

Replace a fan assembly, which is one of the server's hot-swappable components.
Figure 6-1 Server front bezel with grasping areas
62 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 63
Procedure
1. R
emove the front bezel. The fan assemblies will then be visible.
2. Identify the fan to be replaced.
Fans are labeled on the chassis, and are numbered 1 and 2, with fan 1 on the left and fan 2 on the right. Refer to the fan status LEDs on front panel of the server (behind the bezel) to see which fan has failed. In the following figure, number 1 indicates the status LED for fan 1 (the left­side fan), and number 2 indicates the status LED for fan 2 (the right-side fan).
Figure 6-2 Fan status LEDs
Item Description
1 Fan 1 status LED
2 Fan 2 status LED
emove the faulty fan by loosening the thumbscrews (turning them
3. R
counter-clockwise) until they are loose, then pulling the fan unit straight out of the chassis. (The fan lead connector disengages automatically as you remove the fan assembly.)
Figure 6-3 Fan assembly - G2 models 3080 and 3090
Replacing server components 63
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 64
4. Put the new fan assembly into place.
5. Gently press the fan assembly back into the chassis. The fan electrical
connector will be aligned automatically when the fan is fully inserted into the chassis.
6. Secure the fan assembly in position b
y tightening the thumbscrews
(turning them clockwise).
7. Replace the front bezel.

Replacing the NVRAM backup battery pack

To replace the NVRAM backup battery pack in a server, you remove the old battery and install the new replacement. Perform the battery pack replacement as quickly as possible, and only when the new pack is present.
To install a new NVRAM backup battery pack in a server, you must remove the battery caddy. If you have a replacement battery without a caddy, you can replace the battery inside the caddy, then reinstall the caddy.
Note: If possible, shut down the serv pack. Shutting down the server or migrating all of the EVSs to the other node is not required. However, during the replacement procedure, there will be a period of time when the NVRAM contents are not backed up by the battery pack. If a power failure occurs during this period, the NVRAM contents may be lost.

Checking battery pack status

The battery pack status LED indicates the status of the serv battery pack.
Table 6-1 Battery pack status LED
LEDs Meaning
Red
Off
If this LED is on immediately after installing a new battery pack, it indicates that an initial battery charging and conditioning cy battery conditioning takes approximately 24 hours, and the LED will turn off after the cycle is complete.
If this LED is on during normal operation (not after installing a new battery pack), either the battery has exceeded its two year life or a problem has been detected. Check the battery status before determining any service operation.
Normal operation.
er before replacing the battery backup
er's NVRAM
cle is in progress. The initial
64 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 65
Figure 6-4 Battery pack status LED location
Battery related information is also saved in a battery status log. These logs, along with the server’s event log, are useful in monitoring the state of the battery.
Turning the battery status LED off can require one or more of the following steps. Try the steps in the following order:
Procedure
1. Perform a battery pack test cycle. To begin the test cycle, do the
2. Remove and reinstall the battery pack.
3. If the battery is still having problems, replace the battery pack. (A new
-related events are recorded in the server’s event log. Other battery-
following:
1. Access the server CLI. .
2. Issue the following Linux command: touch /var/opt/chassis-
monitor/.testbatterynow
battery pack is required.)

Identifying a cluster node that requires battery replacement

If you have warnings or battery-related events in the Event Log of a cluster, you can identify the cluster node requiring battery replacement using the following procedure:
Procedure
1. Access the server command line interface.
For information about how to access the server command line interface, refer to the Hitachi NAS Platform System Access Guide.
2. Log in to the server as manager with the default password of nasadmin.
These credentials provide access to the Bali console.
3. Enter the command led-identify-node x, where x is the node
mentioned in the Event Log message. Both the server status and fault LEDs on the node will flash, allowing you
to identify the node. Refer to the Hitachi NAS Platform Command Line Reference for more information on the led-identify-node command.
Replacing server components 65
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 66

Replacing the NVRAM battery module

Y
ou can easily replace the NVRAM battery pack in a server. The battery module is hot-swappable; however, if possible, shutdown the server before replacing the module.
Prerequisites
Identify the server model before installing the battery.
Important: During the replacement procedure, the NVRAM contents are not back
ed up by the battery pack. If a power failure occurs during this period, NVRAM contents may be lost. See the appropriate hardware reference or maintenance documentation for procedures to power down a server.
Figure 6-5 NVRAM battery module removal components - models 3080
and 3090
Item Description
1 Thumbscrew that holds the battery pack in place
2 Handle for moving the battery pack forward and backward in the chassis
Procedure
emove the bezel cover from the front of the server for access to the
1. R
batteries.
2. Loosen the thumbscrew to the right of the battery pack module cover by
turning it counter-clockwise.
3. Using the handle, pull the battery pack module straight out of the
chassis. The battery pack is automatically disconnected.
4. Insert the replacement module straight into the chassis, and gently but
firmly push the pack into position. The battery pack is automatically connected.
66 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 67
5. Tighten the thumbscrew b
6. Replace the server bezel.
7. Dispose of the old battery pack in accordance with environmental
regulations or return to the supplier.
8. Log into the server using SSH from the system management unit (SMU)
Linux command line.
9. Issue the command: new-battery-fitted --field --confirm
10. Restart the chassis monitor:
1. Exit BALI by entering the exit command or press the CTRL+D keys.
2. Log into Linux as root by issuing the command: su-; [password]
Where [password] is the password for the root user account.
3. Issue the command: /etc/init.d/chassis-monitor restart

Replacing a hard disk

Before you replace a hard disk, determine whether the disk is truly bad.
y turning it clockwise.
Deciding on hard disk recovery or replacement on page 67 to mak
See that determination.
After you replace a hard disk, synchronize the new disk with the older disks in the system.

Deciding on hard disk recovery or replacement

A number of hard disk drive failures can occur. Some failures require disk replacement, others only require performing a recovery process. Use the process described in this section to help ensure that all partitions are recovered before proceeding with any further disk recovery or replacement procedures.
Before you consider replacing a hard disk drive, be sure you understand the following points:
• Do not attempt to replace an HDD unless you are instructed to do so by
Hitachi Data Systems Support Center.
• Failed hard disks are hot-swappable, so a failed hard disk can be replaced
without shutting down the server. However, there are serious risks in trying to swap a drive that is not failed.
• Do not assume that because the red LED is illuminated that a drive is
faulty. Under a RAID rebuild/recovery, the red LED would be illuminated. If the drive is failed and needs replacing, you can remove it from the server.
• Do not replace a drive that has not actually failed. If the disk shows signs
of failure, shut down the server before replacing the drive and restarting the server.
• There should be no reason to pull out a hard drive while it is in a known
good configuration, and doing so can potentially lead to data corruption.
• Unless you are certain the hard disk has failed, perform a disk recovery.
e
Replacing server components 67
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 68
• Disk redundancy is unsupported while the disk is removed from the server.
Hard disks can fail for a number of reasons, including corrupt sectors or erroneous blocks of data. T of errors and they do not cause the server to fail.
More serious errors may cause a disk failure, causing one or both hard disks to fall out of the RAID. Should one partition of a disk fail, attempt a disk recovery. If a partition fails repeatedly, replace the hard disk. If all the partitions fall out of RAID, replace the failed drive.

Replacing a hard disk drive

The server contains two hard disk drives (HDDs). The HDDs are field replaceable when directed by Hitachi Data Systems Support Center.
Prerequisites
Obtain the new HDD or HDDs.
Before you replace a hard disk drive, be sure you understand the following points:
• Do not attempt to replace an HDD unless you are instructed to do so by
Hitachi Data Systems Support Center.
• Failed hard disks are hot-swappable, so a failed hard disk can be replaced
without shutting down the server. However, there are serious risks in trying to swap a drive that is not failed.
• Disk redundancy is unsupported while the disk is removed from the server.
ypically, the RAID controller handles these types
Caution:
Do not remove or replace a non-failed (operational) HDD that is in a
working configuration; that means that the HDD is in use. Replacing a disk while the disk is in use can cause data corruption or disk damage.
• When ejecting an HDD, be certain that you only press the release button
for the one drive. If you press the wrong release button or both release buttons, the server will malfunction.
• If, by chance, you eject both of the HDDs, it is highly likely that the
system is corrupted. The best chance for data recovery is to do the following. Do not re-insert the drives. First, hard power down the server, and then re-insert the drives and reboot. When the system comes back online, confirm whether the NVRAM is recovered.
Both HDDs are located at the front of the chassis behind the bezel. The HDDs are mounted in driv with their drive numbers, A and B. No tools are required for drive replacement.
e trays for ease of replacement. The trays are marked
68 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 69
Procedure
1. Mak
e sure you have the new hard disk(s) present.
2. Identify the HDD to be replaced. Using Web Manager GUI, confirm which
HDD is to be replaced. The LED of the drive that requires replacement is red. If both drive LEDs
are red, see the SMU messages for guidance.
3. From the node's CLI, issue the command chassis-drive-clean-
configuration --disable --drive drive_letter
Where drive_letter is A or B, the letter of the drive you are replacing. For example, chassis-drive-clean-configuration --disable --
drive A
This command removes the drive from the RAID group, so you can continue with the rest of the steps
4. Remove the HDD:
a. Double-check that you are looking at the intended drive to be
removed.
b. Carefully press the button on the right side of the front of the disk tray
to release the retention latch handle.
Caution: Mak
e sure that you only press the release button for that
one drive.
c. Pull the retention latch handle outw
ard to disengage the disk from the
server.
d. Slide the disk tray out of the chassis.
5. Insert the replacement HDD:
a. Slide the replacement disk into the chassis until the retention latch
handle starts to close.
b. Press the retention latch handle towards the chassis to secure the disk
in the server. When the disk tray is fully seated, the retention latch handle will click into the closed position.
Caution: R
eplace only one HDD at a time. If both HDDs require
replacement, perform this procedure for each HDD.
6. Replace the bezel .
7. Log in to the server as the root user.
a. Use SSH to connect to the server using the manager account. By
default, the password for the manager account is nasadmin, but this password may have been changed.
b. To gain access as root, press Ctrl-D to exit the console, then enter su
. When you are prompted for the root password, enter it for the root
user account. By default, the password for the root account is nasadmin, but this password may have been changed.
Replacing server components 69
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 70
8. R
un the script /opt/raid-monitor/bin/recover-replaced-drive.sh, which will partition the disk appropriately, update the server’s internal RAID configuration, and initiate the rebuilding of the RAID pair.
Rebuilding the RAID pair ensures all data is accurate across both hard disks.
9. After the script has finished, follow these steps: a. Check the status logging into the NAS OS console (Bali).
b. Issue the command: chassis-drive-status
c. Repeat until all partitions are synchronized.
The RAID system rebuilds the disk as a background operation. The events are logged as the RAID partitions rebuild and become fully fault tolerant. The rebuild process can take up to an hour. The status indicator indicates normal operation (solid or flashing blue) once the RAID configuration has been repaired.
10. Log out.
11. Properly dispose of the used HDD. Do not attempt to re-install or re-use
the used HDD.

Synchronizing a new disk

After replacing a hard disk, the new disk in the server’s internal RAID subsystem must be synchronized with the older disk.
Procedure
1. Wait until the LEDs on the front of the server slow to indicate normal activity.
2. Use a serial cable connected to the serial (console) port of the server to access the Bali console.
3. Once you have successfully logged in, select the server or node that has the disks you want to synchronize.
4. Run the chassis-drive-status command, and look at the values in the Status and % Rebuild columns for each device.
• The values in the Status column should be “Invalid.”
• The% Rebuild column should not display any values.
5. Run the script /opt/raid-monitor/bin/recover-replaced-disk.sh. This script partitions the replacement disk appropriately, updates the server’s internal RAID configuration, and initiates rebuilding the replaced disk. The RAID system rebuilds the disk as a background operation, which takes approximately 50 minutes to complete. Events are logged as the RAID partitions rebuild and become fully fault tolerant.
6. Monitor the rebuilding process by running the chassis-drive-status command, and check the values in the Status column for each device. The values in the Status column should be:
70 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 71
• “Good” for synchronized volumes.
“Rebuilding” for the volume currently being synchronized.
• “Degraded” for any volume(s) that have not yet started the
synchronization process.
7. Once the rebuild process has successfully completed, run the trouble chassis-drive command.
If the command response displays issues, resolve them if possible, or contact technical support for assistance.
If the command response displays “No faults found,” continue the disk replacement process by replacing the second hard disk.
8. Shut down the server.

Replacing a power supply unit

You can replace a power supply unit (PSU) as a hot-swappable server component. The server can operate on a single PSU if necessary, making it possible to replace a failed PSU without shutting down the server. If a PSU fails, it should be replaced as quickly as possible, because operating on a single PSU means that there is no redundancy in that area, increasing the risk of an interruption in service to clients.
LED indicators on each PSU indicate the PSU status.
Figure 6-6 PSU locations on HNAS 3080 and 3090 rear panel
Item Description
1 PSU 1
2 PSU 2
Replacing server components 71
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 72
Figure 6-7 PSU components
Item Description
1 PSU fan
2 Power plug
3 Retaining latch
4 Handle
5 DC power LED
6 Malfunction or failure LED
7 AC power LED
Procedure
1. R
emove the power cord from the PSU.
2. Move the retaining latch to the right (you may hear a slight click if the PSU moves when the latch disengages).
3. Using the handle on the PSU, pull the PSU out from the back of the server until you can completely remove the PSU from the chassis.
4. Insert the replacement PSU. The retention latch should click into position all the way to the left when the PSU is fully inserted. If the PSU that is not being replaced is receiving mains power when the replacement PSU is fitted, the fan on the replacement PSU becomes active.
5. Connect the power cord to the back of the PSU. The PSU should start as soon as the power connection is made. If the PSU does not start immediately, make sure the mains power circuit is live and that the other end of the power cable is connected to a live outlet.

Replacing an FPGA board as a FRU

Typically, when an FPGA board fails, the whole Hitachi NAS Platform server is replaced. However, in some cases with the HNAS 3080 and 3090 platform models, an FPGA board may be replaced as a field replaceable unit (FRU).
72 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 73
An FPGA board is also known as the main FPGA board (MFB).
Contact FPGA can be replaced as a FRU.
Note: If y server FRU may be received, instead of just the FPGA FRU.
Hitachi Data Systems Support Center to determine whether your
ou receive a replacement FRU, in some instances, a complete

Requirements for Replacing FPGA board

MFB replacement may not be performed while the server is operation; the server must be shut down and removed from the rack before the replacement procedure can be started. After the MFB has been replaced, the server can be put back into the rack, reattached, and restarted.
Tools and Requirements
• #1 Phillips screwdriver.
• Replacement MFB.
• ESD wrist strap.

Replacing the FPGA board

MFB replacement ma server must be shut down and removed from the rack before the replacement procedure can be started. After the MFB has been replaced, the server can be put back into the rack, reattached, and restarted.
Procedure
1. Using Web Manager, log in and select Reboot/Shutdown from the Server Settings page to display the Restart, Reboot and Shutdown
page. Note that the page has different options depending on the configuration of your system.
2. Click Shutdown to stop file serving EVSs on the server, and then shut down and power off the server.
3. Remove the fascia. See
4. Disconnect all power and networking cables from the serv
5. Completely remove the server from the rack.
Use caution when removing the server as the current rails do not have "stops." Two people should be available to unmount and move the unit.
6. Place the server on a level work surface such as a table or cart.
y not be performed while the server is operation; the
Bezel removal on page 62.
er.
Replacing server components 73
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 74
7. Using the #1 Phillips screwdriv retaining screws.
er, remove and set aside the two (2) MFB
74 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 75
8. Without lifting the MFB
, slide the MFB towards the rear of the server, as
shown in the next illustration.
The MFB should slide approximately 2 to 2.5 inches (5 to 7 centimeters), creating a gap between the MFB and the top front of the chassis.
Looking into the gap
, you will see six (6) cables connecting the MFB to
the rest of the server. A cable tie is used to secure each cable.
Replacing server components 75
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 76
9. Disengage the cable ties from the shell of the MFB b
y squeezing the tabs
at the base of the cable ties.
10. Once all cable ties ha
ve been disconnected, disconnect the cable connectors from the mating MFB connectors by pressing the connector retainer tabs.
11. Once all internal cables have been disconnected, remove the MFB. Turn it
upside down and place it on a flat work surface.
12. Open the box that contains the replacement MFB module. Remove the
module and orient it so that the module cover labels face down. This will protect the sheet metal tabs on the bottom side of the module (see next illustration).
76 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 77
13. Place the labeled co
ver down on a flat work surface and remove the
module from the ESD shielding bag.
14. MFBs ma
y be shipped with a metal shim under the retaining clip. Remove
the metal shim before proceeding to the next step.
15. Replacement modules may ship with a metal shim under the sheet metal
retainer tabs. If so, remove the tape and slide the shim out from under the tabs.
16. Lift the module from the work surface, turn it over so the labels face up,
and place it into the server chassis. Slide it fully to the rear to expose mating cables.
17. Connect the cables, ensuring that each is securely fastened.
18. Engage the cable ties.
19. Push the MFB module forward until the front lip slides under the front
half of the server cover. Apply adequate pressure to force the woven EMI gasket under the front cover and to align the MFB front retainer holes with the mating threads on the base server sheet metal
20. Secure the MFB to the chassis base using the screws that were
previously removed. Carefully secure the screws using the #1 Phillips driver. Avoid over-tightening the fasteners.
21. Replace the server in the rack, and reconnect the network and power
cables. Refer to the System Installation Guide for more information about racking and cabling the server.
22. Transfer the SFPs and XFPs from the old MFB to the replacement MFB.
23. After the replacement, you can power up the server and check the dblog
for the message:
MMB1 Warning: Hardware MFB1 has been replaced (B1004002 -> B0916023)
Replacing server components 77
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 78
24. Place the replaced module in the shielding bag and insert it in the
original packaging for return to the supplier
.
78 Replacing server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 79
Replacing server components 79
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 80
7
Rebooting, shutting down, and
powering off
This section pro a server or cluster.
See the System Installation Guide for details about server software licenses.
Rebooting or shutting down a server
Rebooting or shutting down a cluster
Restarting an unresponsive server
Powering down the server for maintenance
Powering down the server for shipment or storage
Powering on the server or cluster
Recovering from power standby
vides instructions on how to reboot, shut down, and power off

80 Rebooting, shutting down, and powering off

Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 81

Rebooting or shutting down a server

The serv
Procedure
1. Using Web Manager, log in and select Reboot/Shutdown from the
er can be shutdown or reset if a manual reboot is necessary.
Server Settings page to display the Restart, Reboot and Shutdown page. Note that the page has different options depending on the configuration of your system.
2. Click the button for the action y
Configuring cipher suites
Configuring the SSL/TLS versionObtaining and importing a CA-signed certificate
Click restart to restart all file serving EVSs on the server.
• Click stop to stop file all serving EVSs on the server.
• Click Reboot to stop file serving EVSs on the server, and then reboot
the entire server. Note that rebooting may take up to five minutes.
• Click Shutdown to stop file serving EVSs on the server, and then shut
down and power off the server.
ou want to perform as described next:
Rebooting, shutting down, and powering off 81
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 82

Rebooting or shutting down a cluster

Procedure
1. Using W
eb Manager, log in and select Reboot/Shutdown from the
Server Settings page to display the Restart, Reboot and Shutdown page. Note that the page has different options depending on the configuration of your system.
2. Click the button for the action y
Option Action
Restarting File Serving
Stop File Serving
Reboot
• To restart all file serving EVSs on a single node, select the Restart on node option, use the drop-down list to select a node, and then click restart.
To restart all file serving EVSs on all cluster nodes, select the Restart on all nodes option and then click restart.
• To stop all file serving EVSs on a single node, select the Stop file serving on node option, use the drop-down list to select a node and then click stop.
• To stop all file serving EVSs on all cluster nodes, select the Stop file serving on all nodes option and then click stop.
• To reboot a single node, select the Reboot node option, use the drop-down list to select a node, and then click reboot
• To reboot all cluster nodes, select the Reboot all nodes option and then click reboot.
ou want to perform as described next:
82 Rebooting, shutting down, and powering off
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 83
Option Action
Note: Clicking R
node or all cluster nodes, then reboots the node/nodes. Rebooting may take up to five minutes.
Shutdown
• To shut down a single node, select the Shutdown node drop-down list to select a node. and then click shutdown
• To shut down all cluster nodes, select the Shutdown all nodes option. and then click shutdown.
Note: Clicking Shutdown stops all file serving EVSs on the
selected node or the cluster selected node or all nodes in the cluster. The PSU is still powered on and the node is not ready for shipment.

Restarting an unresponsive server

Perform this process to restart an unresponsive server from the server operating system (OS) console. You generate a diagnostic log that can help you better understand the problems. You can gain access either by using SSH software to connect to the server's CLI or connecting to the server serial port.
eboot stops all file serving EVSs on the selected
option, use the
, then shuts down and powers off the
Procedure
1. Connect to the SMU using the ssh software.
2. From the siconsole, select the server.
• If the system fails to respond, go to step 3.
• If the system takes you to the server OS console, issue the command: bt active, so you can view the display.
• If you are still at the siconsole, select q, press Return, and then perform the following steps:
1. Connect directly to the MMB as manager using ssh.
2. If the connection succeeds, you are taken to the server OS
console, where you issue the command: bt active
3. If the connection fails, continue to step 4.
3. Connect to the system with a serial null modem cable, and perform the
following steps: See Serial port on page 56 if y
ou need details.
1. Login as manager or you will get the Linux prompt, not the server
OS. If you use root, use ssc localhost.
2. Issue the command: bt active
Rebooting, shutting down, and powering off 83
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 84
4. If y
ou are still unable to get to the server OS, perform the following
steps:
1. Check to make sure that the Bali CLI is booting successfully.
2. Log in through the serial cable connection.
3. Tail /var/opt/mercury-main/logs/dblog
4. Search the log for the entry MFB.ini not found run nas-
preconfig.
• If the entry is present, the system has been unconfigured by either running the unconfig script or removing the node from a cluster.
• If the entry is not present, monitor the dblog during the boot cycle to see where it fails.
Warning: If the serv
er is still unresponsive, do not pull the plug. Instead, see the next step. The reboot time varies from system to system. The reboot can take up to 20 minutes, because a dump is compiled during the reset process.
5. Check the green LED on the front panel of the serv
er for the server
status.
Table 7-1 Server status - model HNAS 3080 and 3090
Server status LED Meaning
Amber Critical failure and server is not operational.
Slow green flash (every three seconds) System has been shut down and you can remove
the power.
Medium green flash (every .8 seconds) Server needs attention, and a non-critical failure
has been detected. For example, a fan or power supply has failed.
Off Normal operation.
6. If the green LED is flashing 5 times per second, plug in the serial cable.
If the terminal screen is generating output, let the process complete.
• If the terminal screen is blank, press the Reset button.
Note: Pulling the power cord from the serv not pull the power cord unless it is absolutely necessary. First, complete the steps above.
84 Rebooting, shutting down, and powering off
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
er is not recommended. Do
Page 85

Powering down the server for maintenance

This procedure should be followed whenev and will be left off for less than a day. If, however, the system is being rebooted, this procedure is not necessary.
Procedure
1. Shut down the server(s) as described in
server on page 81.
2. If y
3. Power off the storage subsystems, beginning with the enclosures that
4. Power off the expansion enclosures for the storage subsystems.
our system is configured with an external System Management Unit (SMU), depress the red button located on the right of the unit to turn it off (an internal SMU is turned off when the server shuts down).
house the RAID controllers.
er a server is to be powered down
Rebooting or shutting down a

Powering down the server for shipment or storage

Follow this procedure whenever a server is to be powered down and will be left off for more than a day. If the system is being restarted or power-cycled, this procedure is not required.
When the system is properly shut down, depending on the battery charge level, the battery may last up to one year without being charged or conditioned . See
NVRAM backup battery pack on page 42
for details.
Contact your representative for special instructions if servers or NVRAM battery backup packs will be in storage for more than one year. Special provisions are required for field or factory recharging and retesting of NVRAM battery backup packs.
Procedure
1. From the NAS operating system (Bali) console, issue the command:
shutdown –-ship --powerdown
2. Wait until the console displays the message Information: Server has
shut down and the rear panel LEDs turn off.
Note: The PSUs continue to run, and the PSU LEDs sta
ower down the server by removing the power cables from the PSU
3. P
modules.
4. Wait 10-15 seconds, then check that the NVRAM Status LED on the rear
panel of the server is off.
y on.
Rebooting, shutting down, and powering off 85
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 86
• If the NVRAM status LED is off, the battery backup pack no longer
powers the NVRAM, so that the battery does not dr
ain.
Note: Use this state for serv
• If the NVRAM status LED is on (either on steady or flashing), press
and hold the reset button for five seconds until the NVRAM Status LED begins to flash rapidly. Release the reset button to disable the battery. The NVRAM Status LED goes out.
Note: The NVRAM contents are lost. The battery is re-enabled when power is restored to the serv

Powering on the server or cluster

T
o start/power on a server or cluster:
Procedure
1. Verify that all servers are switched off.
2. Start all storage subsystems, beginning with the expansion enclosures.
Wait until the disk LEDs on all of the expansion enclosures have stopped blinking (which indicates that they are spinning up) or two minutes, whichever comes first, then start the storage subsystem RAID controller enclosures. Note that the disk drives in some storage enclosures will not spin up until commanded to do so by the RAID controller, so the LEDs may continue to blink until after the RAID controller enclosure has sent those commands and the drives have spun up.
3. For a cluster configuration, or when using an external System
Management Unit (SMU), start the SMU by depressing the red button located on the right of the unit. Wait one minute to allow the external SMU to start.
4. Power up the server or the first node in the cluster: a. If the power cables are not connected to the PSU, plug in the power
cables.
b. If, after 10 seconds, the PSU LEDs are lit but the Power Status LED on
the rear panel is not lit, press the PWR button on the MFB to restore the power to the system boards. Report this as a problem to the Hitachi Data Systems Support Center.
c. If the power cables are connected to the PSU, press the PWR (power)
button on the rear of the server.
5. If you are starting a cluster, wait 5-10 seconds before powering on the next node in the cluster.
er storage or shipment.
er.
86 Rebooting, shutting down, and powering off
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 87

Recovering from power standby

When the serv and the PSU LEDs are lit, but the Power Status LED on the rear panel is not lit.
The server will enter a standby power state due to any the following:
• The shutdown --ship --powerdown command has been issued.
• The PWR button was pressed when the server is running.
• The server has shut down automatically due to an over temperature
condition. You can restore the server to its normal power state by either of the
following methods:
• Pressing the PWR button.
• Remove the power cables from both PSUs, wait for 10 seconds, then
reconnect the cables to the PSUs.
er is in a power standby state, the power supplies are powered
Rebooting, shutting down, and powering off 87
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 88
A

Server replacement procedures

The replacement of the serv several forms depending on how the system was originally deployed. The typical field deployment scenarios documented for service replacement include:
• Single stand-alone server using an embedded SMU for management
• Single stand-alone server using an external SMU for management
• Two-node cluster using an external SMU for management-replacing only
one node
• Two-node cluster using an external SMU for management-replacing both
nodes
Important: This document does not treat migr different configurations at the time of replacement.
Replacement procedure overview
Replacing a single server with an embedded SMU
Replacing a single server with an external SMU
er as part of a field service process can take
ation scenarios between
Replacing a node within a cluster
Replacing all servers within a cluster
88 Server replacement procedures
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 89

Replacement procedure overview

This section highlights the requirements and consider nodes.

Requirements

Any personnel attempting the following procedures must have completed the necessary training before proceeding. Much of the process required for a server replacement is the same process covered in installation and configuration training. No personnel should attempt to replace a unit without adequate training and authorization.
Determine which replacement scenario is being encountered in advance. The replacement process is different for each scenario.
Acquire the temporary license keys before arriving onsite to expedite the server replacement. The license keys are necessary because they are based on the unique MAC ID for the server or cluster. New license keys are not required when replacing one server in a cluster.
Note: R management unit (SMU), so you must have a SMU installed before you can connect to a standalone server.
ations when replacing
eplacement servers are shipped without an embedded system
You can use a KVM (keyboard, video, and mouse) device or a serial cable to connect to the serial port. Bring both devices with y needed when the unit arrives. If you connect to the serial port, use the following SSH client settings:
• 115,200 b/s
• 8 data bits
• 1 stop bit
• No parity
• No flow control
• VT100 emulation

Swapping components

The server can be replaced onsite. However, some components are not included in the replacement server that you receive. You must remove those components from the original server and use them in the replacement server. There are a minimum of four parts to be reused in the replacement server.
The components that can be swapped include:
• Battery
• Bezel
• Rack mounting guides
ou just in case both are
Server replacement procedures 89
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 90
Note:
New power supplies are shipped installed in the server, and do not need to be swapped.

Model selection

The softw before it is shipped from either the factory or depot location.
If for any reason the model selection does not match that which is required for replacement, then an upgrade process may be required in the field.
The upgrade process is outside the scope of this document and documented separately. Contact Hitachi Data Systems Support Center for upgrade information.
are for all server models is pre-loaded on the replacement server

MAC ID and license keys

The replacement server will have a new MAC ID. The new ID forces the need for new license keys regardless whether it is a single node or complete cluster replacement.
As part of a field replacement process, Hitachi Data Systems recommends that temporary keys be obtained to enable quick delivery and implementation. However, any temporary keys used must eventually be replaced with a permanent key. This is required for all field scenarios, except when replacing a single node in a cluster.
Note: If the scenario is a single node or all cluster node replacement, use the span-allow-access changes.
command to attach the storage when the MAC ID

Previous backups

A system backup preserv
• SMU configuration
• Server configuration
The backup form for an embedded SMU is different than one from an external SMU. Depending on the replacement scenario severity, different limitations might exist for the system recovery.
Important: It is assumed that customers are frequently establishing backups somewhere safely off the platform for reco no backup, and the system to be replaced is nonfunctional, then a manual recovery process is required to reestablish a functional system. The duration of this manual recovery is directly related to the complexity of the original configuration. All data and file systems are preserved independent of a backup.
90 Server replacement procedures
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
es two critical components of information:
very purposes. If there is
Page 91

Upgrades

R
eplacement servers can be down or above a revision, and not at the expected level of firmware required at the customer site. An upgrade is typically required during the replacement process, which is not covered in this document. It is assumed that all services personnel performing a replacement have already been trained, and know where to get this information within their respective organization.

Replacing a single server with an embedded SMU

If a single server with an embedded SMU is non-functioning, and does not have a recent backup saved off platform, then a challenging and manual recovery process is necessary. If this circumstance is encountered, call the support organization for a copy of the system's latest diagnostics files. If available, these files can be used as a guide in reestablishing the system manually. The data and file systems will remain intact independent of the replacement and without a backup.
Note: R management unit (SMU), so you must have a SMU installed before you can connect to a standalone server.
Important: Set expectations up front with the customer that this will dela time to recovery, and that some aspects of the systems configuration might never be recovered.
eplacement servers are shipped without an embedded system

Obtaining backups, diagnostics, firmware levels, and license keys

On the old serv
er:
y
Server replacement procedures 91
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 92
Procedure
1. If the serv
er is online, using Web Manager (SMU GUI), navigate to Home
> Server Settings > Configuration Backup & Restore, click backup, and then select a location to save the backup file.
Ensure you save the backup file to a safe location off platform so that y
ou can access it after the storage system is offline.
The backup process performed by the embedded SMU will automatically capture both the SMU and server configuration files in one complete set.
2. Navigate to Home > Status & Monitoring > Diagnostics download
to download the diagnostic test results.
3. Navigate to Home > SMU Administration > Upgrade SMU to verify
SMU type and firmware release level. Both the server and SMU firmware versions must match those on the failed server; otherwise, the server cannot properly restore from the backup file. See the release notes and the System Installation Guide for release-specific requirements.
92 Server replacement procedures
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 93
4. Na
vigate to Home > Server Settings > Firmware Package
Management to verify the existing server (SU) firmware release level.
5. Na
vigate to Home > Server Settings > License Keys to check the
license keys to ensure you have the correct set of new license keys.

Shutting down the server you are replacing

On the server that you are replacing:
Procedure
1. From the server console, issue the command: shutdown --ship --
powerdown
Wait until the console displays Information: Server has shut down, and the rear panel LEDs turn off. The PSU and server fans continue to run until you remove the power cables from the PSU module. See the appropriate system component section for more information.
Note: This specific powerdown shipping, and potential long-term, post-replacement storage.
2. Unplug the power cords from the power supplies.
3. W
ait approximately 15 seconds, and then confirm the NVRAM status LED
is off. If the LED is flashing or fixed, press and hold the reset button for five seconds until the LED starts flashing. The battery disables when you release the reset button.
command prepares the system for both
Server replacement procedures 93
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 94
4. Use the following rear panel figure and table to identif
cabling placement on the existing server.
Figure A-1 Rear view of server - models 3080 and 3090
Ite
Labels Ports Connections
m
y and label the
1
2
3
1 Customer data network
2 Customer data network
1 Gigabit Ethernet network port
2 Gigabit Ethernet network port
3 Gigabit Ethernet network port
4 Gigabit Ethernet network port
5 Gigabit Ethernet network port
6 Gigabit Ethernet network port
1 10/100 Private management network Ethernet
port
2 10/100 Private management network Ethernet
port
3 10/100 Private management network Ethernet
port
4 10/100 Private management network Ethernet
port
5 10/100 Private management network Ethernet
port
4 1 Storage or FC switch
94 Server replacement procedures
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 95
Ite
Labels Ports Connections
m
2 Storage or FC switch
3 Storage or FC switch
4 Storage or FC switch
5
6
5. If cables are not labeled, label them before remo
0 Customer facing management network
1 Private management network
ving them from the
server.
6. Remove all cables from the server, and remove the server from the rack.
7. Remove the rail mounts from the old server, and install them on the new
server.
8. Remove the battery from the old server, and install it in the new server.
9. Remove the bezel from the old server, and install it on the new server.
10. Insert the new server into the rack, and connect the power cords to the
power supplies.
Note: Do not mak
e any other cable connections at this time.

Configuring the replacement server

Prerequisites
Obtain the necessary IP addresses to be used for the replacement serv Servers shipped from the factory have not yet had the nas-preconfig script run on them, so a replacement server will not have any IP addresses pre­configured for your use. You need IP addresses for the following:
• 192.0.2.200/24 eth1 (cluster IP)
• 192.0.2.2/24 eth1 (testhost private IP)
• 192.168.4.120/24 eth0 (testhost external IP, which might vary)
Server replacement procedures 95
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
er.
Page 96
When you run the nas-preconfig script, it reconfigures the server to the previous settings. This step allows the SMU to recogniz
e the server as the
same and allows it to be managed. Reconfigured settings:
• IP addresses for Ethernet ports 0 and 1
• Gateway
• Domain name
• Host name
On the replacement server:
Procedure
1. Log in to the server.
2. Run the nas-preconfig script.
3. Reboot if you are instructed to by the script.
4. Log in to the SMU using one of the IP addresses you obtained.
5. Use a KVM (keyboard, video, and mouse) or a serial cable to connect to
the serial port on the server. Alternatively, you can connect by way of SSH using the following
settings:
• 115,200 b/s
• 8 data bits
• 1 stop bit
• No parity
• No flow control
• VT100 emulation
6. Log in as root (default password: nasadmin), and enter ssc localhost
to access the BALI level command prompt.
7. Enter evs list to obtain the IP configuration for the server.
8. Using a supported browser, launch the Web Manager (SMU GUI) using
either of the IP addresses acquired from the EVS list output.
9. Click Yes, and log in as admin (default password: nasadmin).
10. Verify and, if necessary, convert the new server to the model profile
required. This step requires a separate process, training, and license keys. Contact
Hitachi Data Systems Support Center if the incorrect model arrives for replacement.
11. Navigate to Home > SMU Administration > Upgrade SMU to verify
and, if necessary, upgrade the embedded SMU to the latest SMU release.
12. Navigate to Home > Server Settings > Firmware Package Management to verify and, if necessary, upgrade the new server to the
latest SU release.
96 Server replacement procedures
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 97
13. Na Restore, select the desired backup file, and click restore to restore the
system from that backup file.
vigate to Home > Server Settings > Configuration Backup &
14. Reboot the server.
15. Reconnect the data cables to the server.

Finalizing and verifying the replacement server configuration

The Fibre Channel (FC) link speed varies according to the server model. Use the appropriate speed for your model.
Model Fibre Channel link speed
HNAS 3080 and 3090 4 Gbps
On the replacement server:
Note: The following steps show the FC link speed as 8 Gbps as an example.
Procedure
1. Na
2. Remove the previous license keys in the backup file, and add the new
vigate to Home > Server Settings > License Keys to load the
license keys.
keys.
Server replacement procedures 97
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 98
3. Use fc-link-speed to v
erify and, if necessary, configure the FC port
speed as required.; for example: a. Enter fc-link-speed to display the current settings.
host:$ fc-link-speed FC 1: 4 Gbps FC 2: 4 Gbps FC 3: 4 Gbps FC 4: 4 Gbps
b. Enter fc-link-speed -i port_number -s speed for each port.
host:$ fc-link-speed -i 1 -s 4 Set interface 1 link speed OK FC 1: 4 Gbps host:$ fc-link-speed -i 2 -s 4 Set interface 2 link speed OK FC 2: 4 Gbps host:$ fc-link-speed -i 3 -s 4 Set interface 3 link speed OK FC 3: 4 Gbps host:$ fc-link-speed -i 4 -s 4 Set interface 4 link speed OK FC 4: 4 Gbps
c. Enter fc-link-speed to v
erify the settings.
host:$ fc-link-speed FC 1: 4 Gbps FC 2: 4 Gbps FC 3: 4 Gbps FC 4: 4 Gbps
4. Use the fc-link-type command to configure the serv
er in fabric (N) or
loop (NL) mode.
5. Modify zoning and switches with the new WWPN, if you are using WWN-
based zoning. If you are using port-based zoning, the no modifications are necessary for the switches configurations.
6. Open Storage Navigator and reconfigure LUN mapping and host group on
the storage system that is dedicated to the server with the new WWPNs. Perform this step for every affected server port.
7. If the server does not recognize the system drives, enter fc-link-reset
to reset the fiber paths.
8. Enter sdpath to display the path to the devices (system drives) and
which hport and storage port are used.
9. Enter sd-list to verify the system drives statuses as OK and access is
allowed.
10. Enter span-list to verify the storage pools (spans) are accessible.
Note: In this instance, cluster is synon
11. Enter span-list-cluster-uuids span_label to displa
serial number (UUID) to which the storage pool belongs.
98 Server replacement procedures
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
ymous with the standalone server.
y the cluster
Page 99
The UUID is written into the storage pool’s configuration on disk (COD). The COD is a data structure stored in ev information how the different SDs are combined into different stripesets and storage pools.
12. Enter span-assign-to-cluster span_label to assign all the spans to the new server.
13. Verify the IP routes, and enable all the EVSs for file services in case they are disabled.
14. Reconfigure any required tape backup application security.
15. Navigate to Home > Status & Monitoring > Event Logs, and click Clear Event Logs.
16. Navigate to Home > Status & Monitoring > System Monitor and
verify the server status:
• If the server is operating normally, and is not displaying any alarm
conditions, run a backup to capture the revised configuration, and then download another diagnostic to support. Permanent license keys for the replacement server are normally provided within 7 days.
• If the server is not operating normally for any reason, contact support
for assistance.
17. Confirm all final settings, IP addresses, customer contact information, service restarts, client access, and that customer expectations are all in place. Features such as replication and data migration should all be confirmed as working, and all file systems and storage pools should be online.
ery SD, which provides

Replacing a single server with an external SMU

Note that if it is a single server with an external SMU that is nonfunctioning, and does not have a recent backup saved off platform, then a challenging and manual recovery process is necessary. If this circumstance is encountered, call the support organization for a copy of the system's latest diagnostics files, if available, to be used as a guide in reestablishing the system manually. The data and file systems will remain intact independent of the replacement and without a backup.
Note: R management unit (SMU), so you must have a SMU installed before you can connect to a standalone server.
Important: Set expectations up front with the customer that this will dela time to recovery, and that some aspects of the systems configuration might never be recovered.

Obtaining backups, diagnostics, firmware levels, and license keys

On the old serv
eplacement servers are shipped without an embedded system
er:
y
Server replacement procedures 99
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Page 100
Procedure
1. If the serv
er is online, using Web Manager (SMU GUI), navigate to Home
> Server Settings > Configuration Backup & Restore, click backup, and then select a location to save the backup file.
Ensure you save the backup file to a safe location off platform so that y
ou can access it after the storage system is offline.
The backup process performed by the embedded SMU will automatically capture both the SMU and server configuration files in one complete set.
2. Navigate to Home > Status & Monitoring > Diagnostics download
to download the diagnostic test results.
3. Navigate to Home > Server Settings > Firmware Package Management to verify the existing server (SU) firmware release level.
The server firmware version must match the failed server; otherwise, the serv
er cannot properly restore from the backup file. See the release
notes and system installation guide for release-specific requirements.
4. Navigate to Home > Server Settings > License Keys to check the license keys to ensure you have the correct set of new license keys.
100 Server replacement procedures
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Loading...