HIT HD74LV4053A Datasheet

HD74LV4053A
Triple 2-channel Analog Multiplexer / Demultiplexer
ADE-205-284 (Z)
1st Edition April 1999
Description
The HD74LV4053A handles both analog and digital signals, and enables signals of either type with amplitudes of up to 5.5 V (peak) to be transmitted in either direction (at VCC = 0 V to 5.5 V). Applications include signal gating, chopping, modulation or demodulation (modem), and signal multiplexing for analog-to-digital and digital-to-analog conversion systems.
Features
VCC = 2.0 V to 5.5 V operation
All inputs VIH (Max.) = 5.5 V (@VCC = 0 V to 5.5 V)
Function Table
Inputs INH C B A On Channel
L L L L 1Y0, 2Y0, 3Y0 L L L H 1Y1, 2Y0, 3Y0 L L H L 1Y0, 2Y1, 3Y0 L L H H 1Y1, 2Y1, 3Y0 L H L L 1Y0, 2Y0, 3Y1 L H L H 1Y1, 2Y0, 3Y1 L H H L 1Y0, 2Y1, 3Y1 L H H H 1Y1, 2Y1, 3Y1 H X X X NONE
Note: H: High level
L: Low level X: Immaterial
HD74LV4053A
Pin Arrangement
2Y1 2Y0 3Y1
3–COM
3Y0 INH
GND GND
1 2 3 4 5
6 7 8 9
(Top view)
16 15 14 13 12 11
10
V
CC
2–COM 1–COM
1Y1 1Y0 A
B
C
2
HD74LV4053A
Absolute Maximum Ratings
Item Symbol Ratings Unit Conditions
Supply voltage range V Input voltage range* Output voltage range*
1
1, 2
Input clamp current I Output clamp current I Continuous output current I Continuous current through
V
or GND
CC
Maximum power dissipation at Ta = 25°C (in still air)*
3
CC
V
I
V
O
IK
OK
O
or I
I
CC
GND
P
T
Storage temperature Tstg –65 to 150 °C Notes: The absolute maximum ratings are values which must not individually be exceeded, and furthermore,
no two of which may be realized at the same time.
1. The input and output voltage ratings may be exceeded even if the input and output clamp-current ratings are observed.
2. This value is limited to 5.5 V maximum.
3. The maximum package power dissipation was calculated using a junction temperature of 150°C.
–0.5 to 7.0 V –0.5 to 7.0 V –0.5 to VCC + 0.5 V Output: H or L –20 mA VI < 0
±50 mA VO < 0 or VO > V ±25 mA VO = 0 to V
CC
±50 mA
785 mW SOP
500 TSSOP
CC
Recommended Operating Conditions
Item Symbol Min Max Unit Conditions
1
Supply voltage range V Input voltage range V Output voltage range V
CC
I
I/O
2.0* 0 5.5 V 0VCCV
Input transition rise or fall rate t /v 0 200 ns/V VCC = 2.3 to 2.7 V
0 100 VCC = 3.0 to 3.6 V 020 V
Operating free-air temperature Ta –40 85 °C Notes: Unused or floating inputs must be held high or low.
1. With the supply voltage at or around 2 V, the analog switch on-state resistance loses linearity significantly. It is recommended that only digital signals be transmitted at these low supply voltages.
5.5 V
= 4.5 to 5.5 V
CC
3
HD74LV4053A
Logic Diagram
A
B
C
2–COM 1–COM
1Y0
1Y1
2Y0
2Y1
3Y0
3Y1
INH
3–COM
4
HD74LV4053A
OU
DC Electrical Characteristics
Ta = 25°C Ta = –40 to 85°C
Item Symbol VCC (V) Min Typ Max Min Max Unit Test Conditions
Input voltage V
On-state
IH
V
IL
R
ON
switch resistance
Peak on
R
ON (P)
resistance
Difference of
R
ON
on-state resistance between switches
Off-state
Is (OFF) 5.5 ±0.1 ±1.0 µAVIN = VCC, V switch leakage current
On-state
Is (ON) 5.5 ±0.1 ±1.0 µAVIN = VCC or GND switch leakage current
Input current I Quiescent
IN
I
CC
supply current
Note: For conditions shown as Min or Max use the appropriate values under recommended operating
conditions.
2.0 1.5 V
2.3 to 2.7 V
3.0 to 3.6 V
4.5 to 5.5 V
× 0.7
CC
× 0.7
CC
× 0.7
CC
2.0 0.5
2.3 to 2.7 V
3.0 to 3.6 V
4.5 to 5.5 V
CC
CC
CC
× 0.3 × 0.3 × 0.3
2.3 60 180 225 VIN = VCC or GND V
= V
INH
IL
IT = 2 mA
3.0 50 150 190
4.5 40 75 100
2.3 200 500 600 VIN = VCC to GND V
= V
INH
IL
IT = 2 mA
3.0 90 180 225
4.5 50 100 125
2.3 20 30 40 VIN = VCC to GND V
= V
INH
IL
IT = 2 mA
3.0 10 20 30
4.5 7 15 20
=
T
GND or VIN = GND, VO = VCC, V
V
= V
INH
= V
INH
IL
0 to 5.5 ±0.1 ±1.0 µAVIN = 5.5 V or GND
5.5 20 µAVIN = VCC or GND
IH
5
HD74LV4053A
Switching Characteristics
VCC = 2.5 ± 0.2 V
Ta = 25°C Ta = –40 to 85°C
Item Symbol Min Typ Max Min Max Unit Test Conditions
Propagation delay time
Enable time t
Disable time
VCC = 3.3 ± 0.3 V
Item Symbol Min Typ Max Min Max Unit Test Conditions
Propagation delay time
Enable time t
Disable time
t
PLH
t
PHL
2.5 10.0 16.0 ns CL = 15 pF COM
5.0 12.0 18.0 CL = 50 pF
ZH
t
ZL
7.0 18.0 23.0 ns RL = 1 k CL = 15 pF INH COM
9.0 28.0 35.0 CL = 50 pF
t
HZ
t
LZ
9.0 18.0 23.0 ns RL = 1 k CL = 15 pF INH COM
13.0 28.0 35.0 CL = 50 pF
Ta = 25°C Ta = –40 to 85°C
t
PLH
t
PHL
2.0 6.0 10.0 ns CL = 15 pF COM
4.0 9.0 12.0 CL = 50 pF
ZH
t
ZL
5.0 12.0 15.0 ns RL = 1 k CL = 15 pF INH COM
7.0 20.0 25.0 CL = 50 pF
t
HZ
t
LZ
7.0 12.0 15.0 ns RL = 1 k CL = 15 pF INH COM
10.0 20.0 25.0 CL = 50 pF
FROM (Input)TO(Output)
Yn or
or Yn
COM
or Yn
or Yn
FROM (Input)TO(Output)
Yn or
or Yn
COM
or Yn
or Yn
6
Loading...