HIT HD74HC162, HD74HC161 Datasheet

HD74HC160/HD74HC161/
HD74HC162/HD74HC163
Synchronous Decade Counter (Direct Clear)
Synchronous 4-bit Binary Counter (Direct Clear)
Synchronous Decade Counter (Synchronous Clear)
Synchronous 4-bit Binary Counter (Synchronous Clear)
Description
The HD74HC160 and the HD74HC162 are 4 bit decade counters, and the HD74HC161 and the HD74HC163 are 4 bit binary counters All flip-flops are clocked simultaneously on the low to high to transition (positive edge) of the clock input waveform.
These counters may be preset using the load input. Presetting of all four flip-flops is synchronous to thte rising edge of clock. When load is held low counting is disabled and the data on the A, B, C, and D inputs is loaded into the counter on the rising edge of clock. If the load input is taken high before the positive edge of clock the count operation will be unaffected.
All of these counters may be cleared by utilizing the clear input. The clear function on the HD74HC162 and HD74HC163 counters are synchronous to the clock. That is, the counters are cleared on the positive edge of clock while the clear input is held low.
The HD74HC160 and HD74HC161 counters are cleared asynchronously. When the clear is taken low the counter is cleared immediately regardless of the clock.
Two active high enable inputs Enable P and Enable T and a ripple carry output are provided to enable easy cascading of counters. Both enable inputs must be high to count. The Enable T input also enables the Ripple Carry output. When enabled, the Ripple Carry outputs a positive pulse when the counter overflows. This pulse is approximately equal in duration to the high level portion of the QA outputs. The Ripple Carry output is fed to successive cascaded stages to facilitate easy implementation of N-bit counters.
Features
High Speed Operation: tpd (Clock to Q) = 18 ns typ (CL = 50 pF)
High Output Current: Fanout of 10 LSTTL Loads
Wide Operating Voltage: VCC = 2 to 6 V
Low Input Current: 1 µA max
HD74HC160/HD74HC161/HD74HC162/HD74HC163
Low Quiescent Supply Current: ICC (static) = 4 µA max (Ta = 25°C)
Function Table
Inputs Outputs Clock Clear*
Note: 1. 162 and 163 Only-160 and 161 are Asynchronous Clear Devices
Asynchronous clear HD74HC160P HD74HC161P Synchronous clear HD74HC162P HD74HC163P
1
L X X X Reset-clear H L X X Load input data H H H H Count H H L X No count H H X L No count
Pin Arrangement
Load Enable P Enable T Q
Decade Counter Binary Counter
n
Clear
Clock
Data Inputs
Enable P
GND
V
1
2
3
A
4
B
5
C
6
D
7
8
CLR
CK
A
B
C
D
P
Load
(Top view)
Ripple Carry
Q
QB
QC
QD
T
A
16
CC
Ripple
15
Carry Output
14
QA
13
QB
12
QC
11
QD
10
Enable T
9
Load
Outputs
2
HD74HC160/HD74HC161/HD74HC162/HD74HC163
DC Characteristics
Ta = –40 to
Ta = 25°C
Item Symbol V
Input voltage V
IH
(V) Min Typ Max Min Max Unit Test Conditions
CC
2.0 1.5 — 1.5 V
4.5 3.15 — 3.15
6.0 4.2 — 4.2
V
IL
2.0 0.5 — 0.5 V
4.5 1.35 — 1.35
6.0 1.8 — 1.8
Output voltage V
OH
2.0 1.9 2.0 — 1.9 V Vin = VIH or VILIOH = –20 µA
4.5 4.4 4.5 — 4.4
6.0 5.9 6.0 — 5.9
4.5 4.18 — 4.13 IOH = –4 mA
6.0 5.68 — 5.63 IOH = –5.2 mA
V
OL
2.0 0.0 0.1 0.1 V Vin = VIH or VILIOL = 20 µA
4.5 0.0 0.1 0.1
6.0 0.0 0.1 0.1
4.5 0.26 — 0.33 IOL = 4 mA
6.0 0.26 — 0.33 IOL = 5.2 mA Input current Iin 6.0 ±0.1 — ±1.0 µA Vin = VCC or GND Quiescent supply
I
CC
6.0 4.0 — 40 µA Vin = VCC or GND, Iout = 0 µA current
+85°C
3
HD74HC160/HD74HC161/HD74HC162/HD74HC163
AC Characteristics (CL = 50 pF, Input tr = tf = 6 ns)
Ta = –40 to
Ta = 25°C
Item Symbol V
Maximum clock f
max
(V) Min Typ Max Min Max Unit Test Conditions
CC
2.0 5 4 MHz frequency 4.5 25 20
6.0 29 23 Propagation delay t time t
PLH
PHL
2.0 160 — 200 ns Clock to Q
4.5 18 32 40
6.0 27 34
2.0 225 — 280 ns Clear to Q
4.5 23 45 56 (HC160, HC161 only)
6.0 38 48
2.0 150 — 190 ns Enable T to Ripple Carry output
4.5 15 30 38
6.0 26 33
2.0 200 — 250 ns Clock to Ripple carry output
4.5 16 40 50
6.0 34 43 Setup time t
su
2.0 125 — 156 ns Data to Clock
4.5 25 9 31
6.0 21 26
2.0 125 — 156 Load to Clock
4.5 25 15 31
6.0 21 26
2.0 125 — 156 Clear to Clock
4.5 25 31 (HC162, HC163 only)
6.0 21 26 — Hold time t
h
2.0 0 0 ns
4.5 0 –7 0
6.0 0 0 — Removal time t
rem
2.0 100 — 125 ns
4.5 20 7 25
6.0 17 21
+85°C
4
HD74HC160/HD74HC161/HD74HC162/HD74HC163
AC Characteristics (CL = 50 pF, Input tr = tf = 6 ns) (cont)
Ta = –40 to
Ta = 25°C
Item Symbol V
Pulse width t
w
(V) Min Typ Max Min Max Unit Test Conditions
CC
2.0 80 100 ns
4.5 16 6 20
6.0 14 17 — Output rise/fall t time t
TLH
THL
2.0 75 95 ns
4.5 5 15 19
6.0 13 16 Input capacitance Cin 5 10 10 pF
Function Table
Count Enable/Disable
+85°C
Control Inputs Result at Outputs Load Enable P Enable T Q
to Q
A
D
Ripple Carry Output
H H H Count High when QA to QD are maximum L H H No count X L H No count High when QA to QD are maximum X H L No count L X L L No count L