Hisense AMS-09UR4SNZA3, AMD-18UX4SJC, AMD-09UX4SJC, AMD-12UX4SJC, AMW2-16U4SGC Service Manual

...
Page 1
MULTI-SPLIT TYPE AIR CONDITONER
SERVICE MANUAL
V: 3.0
INDOOR UNIT:
AMS-07UR4SNZA3 AMS-09UR4SNZA3 AMS-12UR4SNZA3 AMS-18UR4SPZA3 AMD-09UX4SJC AMD-12UX4SJC AMD-18UX4SJC
OUTDOOR UNIT:
AMW2-16U4SGC AMW2-20U4SNC AMW3-24U4SKC AMW4-28U4SKC
Hisense Corporation
Page 2
Table of contents
Page 1OPERATING RANGE 1
2SPECIFICATION 2 2-1 Unit specifications 2 2-2 Major component specifications 5 2-3 Other component specifications 6 3OUTLINES AND DIMENSIONS 8 3-1 INDOOR 8 3-2 OUTDOOR 12 4REFRIGERANT FLOW DIAGRAM 14 4-1 Refrigerant flow diagram 14 4-2 Evacuation procedures 16 4-3 Evacuation direction 17 5ELECTRICAL DATA 18 5-1 Electric wiring diagrams 18 5-2 Electric control 19 5-3 Sensor parameter 30 6CONTROL MODE 31 6-1 Indoor control mode 31 6-2 Outdoor control mode 34 7TROUBLESHOOTING 38 7-1 Error codes 39 8CHECKING COMPONENTS 40 8-1 Check refrigerant system 40 8-2 Check parts unit 42 9PARTS LIST 46 9-1 Indoor 46 9-2 Outdoor 51
Page 3
11.. OOPPEERRAATTIINNGG RRAANNGGE
E
1
T emperature Indoor Air Intake Temp. Outdoor Air Intake Temp
Maximum
32 D.B./23 W.B. 43 D.B./26 W.B.
COOLING
Minimum
21 D.B./15 W.B. 21 D.B./15 W.B.
Maximum
27 D.B./18 W.B. 24 D.B./18 W.B.
HEATING
Minimum
20 D.B/15 W.B -7 D.B./-8 W.B.
Page 4
22.. SSPPEECCIIFFIICCAATTIIOONNSS
2
2-1. Unit specifications
2-1-1.OUTDOOR UNIT
NOTE :Test conditions
Cooling : Indoor: DB27/ WB19 Outdoor: DB35/ WB24 Heating: Indoor: DB20/ WB15 Outdoor: DB7℃/ WB 6
Model AMW4-28U4SKC AMW3-24U4SKC AMW2-20U4SNC AMW2-16U4SGC Function Cooling Heating Cooling Heating Cooling Heating Cooling Heating Power supply a.c 220V~240V/50Hz
Capacity k
W
8.2 9.0 7.0 8.0 5.8 6.4 4.6 5.3
Dehumidification
l /h
---- ---- ---- ---- ---- ---- ---- ----
Capacity
Air flow
m
3
/
h
---- ---- ---- ---- ---- ---- ---- ----
Rated current A 10.7 11.1 9.7 10.1 7.7 8.0 6.1 5.7 Rated input k
W
2.4 2.49 2.18 2.21 1.7 1.75 1.4 1.3 Auxiliary heater A -----­Power factor %
99.9 99.9 99.9 99.9
Electrical data
Max. current A 15.0 15.0 14.5 14.5
SEER/HSPF ----
Model
ATL165SD-C9AU
DA130S1C-20FZ DA130S1C-20FZ
Compressor
Winding resistance
Ω 0.590
(at75℃) 0.95(20℃) 0.95(20℃)
Model YDK70-6H-3 YDK55-6I-8 YDK29-6I-22 Outdoor
fan motor
Winding resistance (at20℃)
Ω
M:78;A:80 M:185;A:200 M:283.5;A:180
Net size
L×W×H
cm
109×41×84 98×35×64
80×26×57
Package size
L×W×H
cm
112×46×98 108×42×72
94×36×64
Net weight kg 67 66 46.2 37.5 Gross weight kg 77 72 52.5 41
Liquid pipe m
m
6.35×4 6.35×3 6.35×2 6.35×2
Gas pipe m
m
9.52×4 9.52×3 9.52×2 9.52×2
Refrigerant piping
Connection method Flare Flare Flare Air direction ---- ---- ---- ----
Sound level (Hi) dB 57 57 56
Fan speed (Hi) rp
m
840 840 900
Fan speed regulator 3 3 3 Refrigerant filling
capacity(R410a)
kg 2.1 2.4 1.4 1.0
Special remarks
Throttle mode
EEV EEV EEV EEV
Page 5
22.. SSPPEECCIIFFIICCAATTIIOONNSS
3
2-1-2.INDOOR UNIT
NOTE :Test conditions
Cooling : Indoor: DB27/ WB19 Outdoor: DB35/ WB24 Heating: Indoor: DB20/ WB15 Outdoor: DB7℃/ WB 6
Model
AMS-07UR4SNZA3 AMS-09UR4SNZA3
AMS-12UR4SNZA3
AMS-18R4SPZA3
Function Cooling Heating Cooling Heating Cooling Heating Power supply a.c 220V~240V/50Hz
Capacity kW 2.6 3.0 3.2 3.8 4.8 5.5 Dehumidification l /h 1.1 ---- 1.4 ---- 1.5 ----
Capacity
Air flow m3/h 420 520 450 560 700 800 Running current A 0.18 0.18 0.18 0.18 0.2 0.18 Rated input kW 40 40 40 40 45 40 Auxiliary heater A ---­Power factor % ----
Electrical data
Starting current A ----
SEER/HSPF ----
Model ----
Compressor
Winding resistance (at25℃)
Ω ----
Model YYW16-4-532 YYW28-4-2085BIndoor
fan motor
Winding resistance (at20℃)
Ω M:364;A:400.5; M:246.2;A:191;
Model ---- Outdoor
fan motor
Winding resistance (at20℃)
Ω ----
Net size L×W×H cm
75×25×19
87×23×31
Package size L×W×H cm
84×31×27
96×40×34
Net weight kg 8.0 12.0 Gross weight kg 9.5 14.0
Liquid pipe mm 6.35 Gas pipe mm 9.52
Refrigerant piping
Connection method ---­Air direction 6 6
Sound level (Hi) dB 37 49 Fan speed (Hi) rpm 1200 1300 Fan speed regulator 3 3
Refrigerant filling capacity(R410a)
kg ----
Special remarks
Throttle mode ----
Page 6
22.. SSPPEECCIIFFIICCAATTIIOONNSS
4
NOTE :Test conditions
Cooling : Indoor: DB27/ WB19 Outdoor: DB35/ WB24 Heating: Indoor: DB20/ WB15 Outdoor: DB7℃/ WB 6
Model AMD-09UX4SJC AMD-12UX4SJC AMD-18UX4SJC Function Cooling Heating Cooling Heating Cooling Heating Power supply a.c 220V~240V/50Hz
Capacity kW 2.6 3.0 3.2 3.7 5.0 5.5 Dehumidification l /h 1.5 ---- 1.5 ---- 1.9 ----
Capacity
Air flow m3/h 440 520 440 520 600 700 Running current A 0.2 0.2 0.2 0.2 0.3 0.3 Rated input kW 44 44 44 44 66 66 Auxiliary heater A ---- Power factor % ----
Electrical data
Starting current A ----
SEER/HSPF ----
Model ----
Compressor
Winding resistance (at25℃)
Ω ----
Model
YSK25-4G
YSK40-4E
Indoor fan motor
Winding resistance (at20℃)
Ω M:247;A:150 M:247;A:150
Model ---- Outdoor
fan motor
Winding resistance (at20℃)
Ω ----
Net size L×W×H mm
770×600×190
770×600×190
Package size L×W×H mm
946×692×236
946×692×236
Net weight kg 20 21 Gross weight kg 24 25
Liquid pipe mm 6.35 Gas pipe mm 9.52
Refrigerant piping
Connection method ---- Air direction ---- ----
Sound level (Hi) dB 35 37
Fan speed rpm
10pa:980/850/700 30pa1150/1070/940
10pa:1290/1150/1010
30pa:1400/1310/1150
Fan speed regulator 6 6 Refrigerant filling
capacity(R410a)
kg ----
Special remarks
Throttle mode ----
Page 7
22.. SSPPEECCIIFFIICCAATTIIOONNSS
5
2-2. Major component specifications
2-2-1.INDOOR FAN MOTOR
PARAMETER
ELECTRIC PERFORMANCE
AMS-07UR4SNZA3 AMS-09UR4SNZA3
AMS-12UR4SNZA3 AMS-18R4SPZA3
Motor model YYW16-4-532
YYW28-4-2085B Rated power source 220V 50Hz 220V 50Hz Phases/Poles 1/4 1/4 Rated load output(W) 16 28 Rated speed(r/min) -- 1250 Ambient temperature()
-5℃~+43. -5℃~+43
PARAMETER
ELECTRIC PERFORMANCE
AMD-09UX4SJC AMD-12UX4SJC AMD-18UX4SJC
Motor model YSK25-4G YSK40-4E Rated power source 220V 50Hz 220V 50Hz Phases/Poles 1/4 1/4 Rated load output(W) 25 44 Rated speed(r/min) 1150/1070/940(Red)
980/850/700(White)
1400/1310/1150(Red)
1290/1150/1010(White) Ambient temperature()
-5℃~+43. -5℃~+43
2-2-2 OUTDOOR FAN MOTOR
PARAMETER ELECTRIC
PERFORMANCE
AMW3-24U4SKC AMW4-28U4SKC
AMW2-20U4SNC AMW2-16U4SGC
Motor model YDK70-6H-3
YDK55-6I-8
YDK29-6I-22 Rated power source 220V 50Hz 220V 50Hz 220V 50Hz Phases /Poles 1/6 1/6 1/6 Rated load output(W) 65 47 28 Ambient temperature()
-5℃~+43 -5℃~+43 -5℃~+43
2-2-3. COMPRESSOR
PARAMETER ELECTRIC
PERFORMANCE
AMW3-24U4SKC AMW4-28U4SKC
AMW2-20U4SNC AMW2-16U4SGC
Compressor model ATL165SD-C9AU DA130S1C-20FZ Compressor type Rotary Rotary Rated power 1550W 990W Current (A) 10.7 4.97
Page 8
22.. SSPPEECCIIFFIICCAATTIIOONNSS
6
Motor type DC brushless motor DC brushless motor Starting type DC Inverter DC Inverter
Motor
Winding resistance
0.59/0.59/0.59
Ω
(at 75℃)
U-V/V-W/W-U
0.95/0.95/0.95Ω(at 20℃) U-V/V-W/W-U
Number of cylinder 2 2 Oil type
α68HES-H or equivalent
ESTER OIL VG74 Oil charge (cc) 880 500 Ambient temperature() -5℃~+43℃. -5℃~+43℃
2-3. Other component specifications
2-3-1. INDUCTANCE
PARAMETER
ELECTRIC PERFORMANCE
AMW3-24U4SKC AMW4-28U4SKC
AMW2-20U4SNC AMW2-16U4SGC
Inductance model R2550HSA R2050HSB Rated power source 220V 50Hz 220V 50Hz Rated current(A) 25 20 Rated inductance
5.0(mH)±10% 5.2(mH)±10% Ambient temperature()
-20℃~+70. -20℃~+70.
2-3-2. FILTER
ELECTRIC PERFORMANCE
AMW3-24U4SKC AMW4-28U4SKC
AMW2-20U4SNC AMW2-16U4SGC
Filter model
RTNF-250T10X-3LF
RTNF250-25T068X-03LF Rated current(A) 20 20 Rated power source
AC 220V—50Hz AC 220V—50Hz
Filter frequency range
150K—30MHHz 150K—30MHHz
Temperature range()
-25℃~+85. -25℃~+85.
Page 9
22.. SSPPEECCIIFFIICCAATTIIOONNSS
7
2-3-4. STEPPER MOTOR
PARAMETER
ELECTRIC PERFORMANCE
AMS-07UR4SNZA3 AMS-09UR4SNZA3
AMS-12UR4SNZA3 AMS-18UR4SPZA3
Stepper Motor model 24BYJ48-CP 24BYJ48-B1 Voltage(DC) 12V 12V Number of phase 4 4 Drive mode 1-2phase excitation unipolar drive 1-2phase excitation unipolar
drive
Resistance per phase
300Ω±7% 300Ω±7% Temperature range()
-10℃~+40 -10℃~+40
2-3-5. OVERLOAD PROTECTION
NONE.
Page 10
33.. OOUUTTLLIINNEESS AANNDD DDIIMMEENNSSIIOO
8
3-1. INDOOR(MODEL: AMS-07UR4SNZA3、AMS-09UR4SNZA3、AMS-12UR4SNZA3
23mm631mm
94mm
190mm
250mm
750mm
50mm
50mm
50mm
65mm
Page 11
33.. OOUUTTLLIINNEESS AANNDD DDIIMMEENNSSIIOO
9
3-2. INDOORMODEL: AMS-18UR4SPZA3
50mm
50mm
50mm
271
195
779
Page 12
33.. OOUUTTLLIINNEESS AANNDD DDIIMMEENNSSIIOO
10
3-3. INDOORMODEL: AMD-09UX4SJC/AMD-12UX4SJC/AMD-18UX4SJC
47
57
508
740
780
808
595
630.2
740
190
688
676
140
168.4
145.5
122
Page 13
33.. OOUUTTLLIINNEESS AANNDD DDIIMMEENNSSIIOO
11
3-3.OUTDOORMODEL: AMW2-16U4SGC
Page 14
33.. OOUUTTLLIINNEESS AANNDD DDIIMMEENNSSIIOO
12
3-4.OUTDOORMODEL: AMW2-20U4SNC
Page 15
33.. OOUUTTLLIINNEESS AANNDD DDIIMMEENNSSIIOO
13
3-5.OUTDOORMODEL: AMW3-24U4SKCAMW4-28U4SKC
Page 16
44.. RREEFFRRIIGGEERRAANNTT FFLLOOWW DDIIAAGGRRAAM
M
14
4-1. Refrigerant flow diagram
MODELAMW3-24U4SKCAMW4-28U4SKC
Filter
B
A
A
C
B
D
C
D
Remark The part is only for AMW4-28U4SKC COOLING CYCLE HEATING CYCLE
Page 17
44.. RREEFFRRIIGGEERRAANNTT FFLLOOWW DDIIAAGGRRAAM
M
15
MODELAMW2-20U4SNC AMW2-16U4SGC
EEV B
EEV A
4-way valve
Filter
B
A
A
B
Filter
Page 18
44.. RREEFFRRIIGGEERRAANNTT FFLLOOWW DDIIAAGGRRAAM
M
16
4-2. Evacuation procedures
EVACUATION PROCEDURES
Connect the refrigerant pipes (both the liquid an
d
g
as pipes) between the indoor and the outdoor units.
Remove service port cap of the stop valve A and connect gage manifold valve and vacuum
p
ump to it.
Run the vacuum pump for more than 15 minutes and at this time confirm that the pressure gage indicates -0.1Mpa(-76 cmHg).
Stop pump and keep the pressure for one or two minutes. Make sure the pressure is no change(if the pressure is changed to high, there is some leakage for the pipe connection).
Remove gage manifold valve quickly from the service port of the stop valve A. full open the stop valves A on gas and liquid pipe sides.
T ot al pi pe len gth is in the range :
N
o gas charge is needed
T ot al pipe length exceeding the limit: Charge the prescribed amount of gas.
Tighten the cap to the service port to obtain the initial status.
Retighten the cap.
Leak test
Repeat the steps above for other valves(B\C\D), be sure all refrigerant pipes are connected and evacuated, and all valves are full opend.
Page 19
44.. RREEFFRRIIGGEERRAANNTT FFLLOOWW DDIIAAGGRRAAM
M
17
4-3. Evacuation direction
MAX. Refrigerant pipe length and height difference:
Modle
AMW3-24U4SKC AMW4-28U4SKC
AMW2-20U4SNC AMW2-16U4SGC
Pipe length per. Indoor unit(a/b/c/d) 25m 20m Total pipe length for multi-system (a+b+c+d) 60m 40m Height difference (I.D ~ O.D) 15m 15m Height difference (I.D ~ I.D) 7.5m 7.5m
*Do your best to reduce the pipe length. Long pipe may cause capacity of the indoor unit incline.
Total refrigerant pipe length
Outdoor unit precharged
0m~20m 20m~60m AMW3-24U4SKC 2100g 0g AMW4-28U4SKC 2400g 0g
Xg = 15g / m × (Total pipe length(m) - 20)
Total refrigerant pipe length
Outdoor unit precharged
0m~15m 15m~40m AMW2-20U4SNC 1400g AMW2-16U4SGC 1300g
0 Xg = 15g / m × (Total pipe length(m) - 15)
Page 20
55.. EELLEECCTTRRIICCAALL DDAATTAA
18
5-1.Electrical wiring diagrams
INDOOR 1AMS-07UR4SNZA3AMS-09UR4SNZA3AMS-12UR4SNZA3
2AMS-18UR4SPZA3
1338610
Page 21
55.. EELLEECCTTRRIICCAALL DDAATTAA
19
2AMD-09UX4SJCAMD-12UX4SJCAMD-18UX4SJC
30Pa
RED
YLW/GRN
RED
BLU
CN24
STEP
MOTOR
STEP MOTOR
STEP MOTOR
WHT
10Pa
GRAY
(FAN_MOTO)
BLU
CN18(FAN_N)
WHT
CN11(FAN_PRO)
FAN CAP
WATER INSPECT
CN21(LEVER SWITCH)
STEP MOTOR
CN05(HEAT_N)
CONTROL BOARD
ELECTRIC WIRING DIAGRAM
CN10(FAN_MOTO)
CN13(FLAP)
CN14(FLAP)
CN15(FLAP)
CN16(FLAP)
CN12(PUMP)
CN23(DISPLAY)
CN17
CN09(TRANCE)
CN08(TRANCE)
CN01(L_IN)
CN02(N_IN)
CN03(SI)
FAN MOTOR
ACFN
PUMP
DISPLAY PANEL
TEMPERATURE SENSOR
TRANSFORMER
BROWN
TO OUTDOOR UNIT
TERMINAL PANEL
4(SI)
1(L)
2(N)
3
HEAT
CN04(HEAT_L)
YLW/GRN
Page 22
55.. EELLEECCTTRRIICCAALL DDAATTAA
20
OUTDOOR 1AMW4-28U4SKC
3( )
WHTBLK
AUXILIARY HEATER
CN10
CN9
CN201
T-DISS
CN205
T-GasD REDYEL
22211
12 1
EXPANSION VALV E D
ELECTRONIC
5
5
CN401 D-EV BLU
432
2341166
SI-D
WHT
T02
1
1
YLW/GRN
4(SI)
2(N)
TERMINAL
1(L)
PANEL D
BLU
BRN
CONNECTION
CAPACITOR
BLU
RED
RED
4(SI)
2(N)
1(L)
4(SI)
2(N)
1(L)
2(N)
1(L)
FAN MOTOR
4-WAY VALVE
ELECTRIC WIRING DIAGRAM 1354457.A
COMPRESSOR
BLUWHT
CN101
CN102
1
1
2
2
3
3
4
4
5
5
IPM BOARD
ELECTROLYTIC
BLU
BRN
CN4
CN1
PRESSURE
CN8 WHT
321
321
7
7
65
4
564 8
899
10
10
VA
FILTER
CN7 FM WHT
12 21
CN6 VA
21
21
4
3
4
3
CN5
CN3
CN2
POWER FILTER BOARD
CN103 P
+
CN204
CAPACITOR
YLW
1
1
2
12 1
114423
23
8
8
65
5677 9910
10
BLU
2
BRN
2
CN203 L2ORG
113
2
3
2
22334
4
CN801 WHT
553
2
3
2
111
1
6
6
CN301 WHT
CN101
CN804
INDUCTOR
CN202 L1
T1 T2 T3
T1 T2
T3
T2
T3
66123
123
456
4
65
54321
32154
654
56
4
T1
121
11222112233
CN202
YEL
CN203BLU
GRN
6 6
11432
234
12345
4321 5
CN403 B-EV WHT
WHT BLK
T05
BLK RED
1
1
T04
1
1
1
1
SI-A
SI-B
SI-C
2
2
CN404 A-EV RED
11543
345
BLU
T01
1
1
ORG
T03
6 6
CN204
T-DEF CN207
T-LiqD CN206
T-Liq-A -B -C T-COIL T-SUC T-OUTT-Gas-A -B -C
CONTROL BOARD
CN402 C-EV BLK
5 5
YLW/GRN
CN104 N
-
CN100
RED
C
N
3
0
2
W
H
T
EXPANSION VALVE B
EXPANSION VALVE A
ELECTRONIC
ELECTRONIC
ELECTRONIC
EXPANSION VALVE C
CM
FM
POWER PANEL
TERMINAL
BLU
FUSE
BLK
CONNECTION
BRN
BLU
PANEL C
1(L)
TERMINAL
YLW/GRN
2(N)
4(SI)
CONNECTION
YLW/GRN
PANEL B
TERMINAL
BLU
BRN
CONNECTION PANEL A
TERMINAL
YLW/GRN
BLU
BRN
YLW/GRN
BLK
RED
WHT
SI-N
BLK
OVERLOAD PROTECTOR
CN208
CN105 WHT
C
N
3
0
1
W
H
T
CN200 LIN CN201 NIN
U
V
W
RED
WHT
BLU
2AMW3-24U4SKC
3( )
WHT BLK
AUXILIARY HEATER
CN10
CN9
CN201
T-DISS YEL
21
12
YLW/GRN
4(SI)
2(N)
TERMINAL
1(L)
PANEL C
BLU
BRN
CONNECTION
CAPACITOR
BLU
RED
RED
4(SI)
2(N)
1(L)
2(N)
1(L)
FAN MOTOR4-WAY VALVE
ELECTRIC WIRING DIAGRAM 1354463.A
1
1
2
2
3
3
4
4
5
5
ELECTROLYTIC
BLU
BRN
CN4
CN1
PRESSURE
CN8 WHT
321
321
7
7
654
564 8
899
10
10
VA
FILTER
CN7 FM WHT
1221 CN6 VA
212
1
4
3
4
3
CN5
CN3
CN2
POWER FILTER BOARD
+
CAPACITOR
YLW
1
1212
1
114423
23
8
8
65
5677 9910
10
BLU
2
BRN
2
ORG
113
2
3
2
22334
4
CN801 WHT
553
2
3
2
111
1
6
6
CN301 WHT
CN101
CN804
INDUCTOR
T1 T2 T3
T1 T2
T3
T2
T3
66123
123
456
4 65
54321
321 54
654
564
T1
112
2112233
CN202
YEL
CN203
BLU GRN
6 6
11432
234
12345
4321 5
CN403 B-EV WHT
BLK
T05
BLK RED
1
1
T04
1
1
1
1
SI-A
SI-B
SI-C
2
2
CN404 A-EV RED
11543
345
BLU
T01
1
1
ORG
T03
6 6
CN204
T-DEF CN207
T-Liq-A -B -C T-COIL T-SUC T-OUTT-Gas-A -B -C
CONTROL BOARD
CN402 C-EV BLK
5 5
YLW/GRN
-
EXPANSION VALVE B
EXPANSION VALVE A
ELECTRONIC
ELECTRONIC
ELECTRONIC
EXPANSION VALVE C
FM
POWER PANEL
TERMINAL
BLU
FUSE
BLK
CONNECTION
BRN
BLU
PANEL B
1(L)
TERMINAL
YLW/GRN
2(N)
4(SI)
CONNECTION
YLW/GRN
PANEL A
TERMINAL
BLU
BRN
CONNECTION PANEL A
TERMINAL
YLW/GRN
BLK
RED
WHT
SI-N
BLK
OVERLOAD
PROTECTOR
CN208
CN105 WHT
COMPRESSOR
BLUWHT
CN101
CN102
IPM BOARD
CN103 P CN204
CN203 L2
CN202 L1
CN104 N
CN100
RED
C
N
3
0
2
W
H
T
CM
C
N
3
0
1
W
H
T
CN200 LIN
CN201 NIN
U
V
W
RED
WHT
BLU
Page 23
55.. EELLEECCTTRRIICCAALL DDAATTAA
21
3AMW2-20U4SNC
4AMW2-16U4SGC
Page 24
55.. EELLEECCTTRRIICCAALL DDAATTAA
22
5-2. Electric control
1. Control board for indoor unit 1 AMS-07UR4SNZA3AMS-09UR4SNZA3AMS-12UR4SNZA3
Page 25
55.. EELLEECCTTRRIICCAALL DDAATTAA
23
2AMS-18UR4SPZA3
5V
GND
12V
Step Motor
Drving
Communication Signal
ac 220V Lin
ac 220V Nin
FAN MOTOR DRVING
TO DISPLAY BOARD
ON/OFF BUTTON
COIL SENSOR
ROOM SENSOR
FAN SPEED FEEDBACK
Page 26
55.. EELLEECCTTRRIICCAALL DDAATTAA
24
3) AMD-09UX4SJCAMD-12UX4SJCAMD-18UX4SJC
Page 27
55.. EELLEECCTTRRIICCAALL DDAATTAA
25
2. Control board for outdoor unitAMW3-24U4SKCAMW4-28U4SKC
1FILTER BOARD
3.15 /250
2)CONTROL BOARD
D Valve Drving
C Valve Drving
B Valve Drving
A Valve Drving
High Pressure Protection
Compressor Discharge Sensor
Outdoor/
Suction/
Condensor
Sensor
Liquid Pipe A/B/C Sensor
Gas
A/B/C
Sensor
Gas D Sensor
Liquid Pipe D Sensor
Defrose
Sensor
Overload Protection
Communication
Signal A
Communication Signal B
Communication Signal C
Communication Signal N
Communication
Signal D
IPM POWER
To Filter Board
To IPM Board
DC -
DC +
DC in
Page 28
55.. EELLEECCTTRRIICCAALL DDAATTAA
26
3)IPM Board
5V
GND
15V
To Main Control Board
To Compressor U
To Compressor V
To Compressor W
IPM Power
To Electrolytic Capacitor -
To Electrolytic Capacitor +
To Electrolytic
Capacitor +
To PFC Inductor-2
To PFC Inductor-1
ac N in
ac L in
Page 29
55.. EELLEECCTTRRIICCAALL DDAATTAA
27
3. Control board for outdoor unitAMW2-16U4SGC AMW2-20U4SNC
1IPM Board
To Compressor U
To Compressor V
To Compressor W
To Electrolytic Capacitor +
To Electrolytic Capacitor +
To Main Control Board
IPM Power
To Electrolytic Capacitor -
To PFC Inductor-2
To PFC Inductor-1
ac N in
ac L in
2)CONTROL BOARD
Overload Protection
Gas B Sensor
Liquid A/B &
Gas A Sensor
Outdoor/Suction/ Condensor Sensor
Compressor Discharge Sensor
B VALVE DRVING
B VALVE DRVING
DC-
DC+
To IPM Board (Power)
To IPM Board
(Communication)
4-Way Valve Drving
Fan Motor Drving
ac N out
ac L out
Earth Wire
ac N in
ac L in
Page 30
55.. EELLEECCTTRRIICCAALL DDAATTAA
28
5-3. Sensor parameter
1. THE PARAMETER OF OUTDOOR COMPRESSOR TEMPERATURE SENSOR: R
0
=187.25K±6.3%;R
100
=3.77K±2.5KB=3979±1%
T(℃) R(KΩ) V(v) DEC HEX T(℃) R(KΩ) V(v) DEC HEX T(℃) R(KΩ) V(v) DEC HEX
-30 966.1 0.1014 5 5 26 55.46 1.3252 68 44 82 6.662 3.7507 191
BF
-29 910.3 0.1075 5 5 27 53.11 1.3678 70 46 83 6.446 3.7813 193
C1
-28 858 0.1139 6 6 28 50.86 1.4112 72 48 84 6.239 3.8111 194
C2
-27 809 0.1206 6 6 29 48.72 1.4552 74
4A
85 6.039 3.8404 196
C4
-26 763.1 0.1277 7 7 30 46.68 1.4997 76
4C
86 5.846 3.8691 197
C5
-25 720 0.1351 7 7 31 44.74 1.5446 79
4F
87 5.661 3.8970 199
C7
-24 679.6 0.1429 7 7 32 42.89 1.5901 81 51 88 5.482 3.9243 200
C8
-23 641.7 0.1511 8 8 33 41.13 1.6359 83 53 89 5.309 3.9512 202
CA
-22 606.1 0.1597 8 8 34 39.44 1.6824 86 56 90 5.143 3.9773 203
CB
-21 572.7 0.1687 9 9 35 37.84 1.7289 88 58 91 4.982 4.0029 204
CC
-20 541.3 0.1782 9 9 36 36.3 1.7762 91
5B
92 4.827 4.0279 205
CD
-19 511.7 0.1881 10
A
37 34.84 1.8235 93
5E
93 4.678 4.0522 207
CF
-18 484 0.1984 10
A
38 33.44 1.8713 95
5F
94 4.534 4.0760 208
D0
-17 457.9 0.2092 11
B
39 32.11 1.9190 98 62 95 4.395 4.0992 209
D1
-16 433.3 0.2206 11
B
40 30.83 1.9673 100 64 96 4.261 4.1218 210
D2
-15 410.2 0.2325 12
C
41 29.61 2.0157 103 67 97 4.132 4.1439 211
D3
-14 388.5 0.2448 12
C
42 28.45 2.0640 105 69 98 4.007 4.1655 212
D4
-13 368 0.2577 13
D
43 27.34 2.1124 108
6C
99 3.886 4.1866 214
D6
-12 348.7 0.2712 14
E
44 26.27 2.1612 110
6E
100 3.77 4.2070 215
D7
-11 330.5 0.2853 15
F
45 25.25 2.2099 113 71 101 3.658 4.2269 216
D8
-10 313.4 0.2999 15
F
46 24.28 2.2584 115 73 102 3.549 4.2465 217
D9
-9 297.2 0.3153 16 10 47 23.35 2.3068 118 76 103 3.444 4.2655 218
DA
-8 281.9 0.3312 17 11 48 22.46 2.3552 120 78 104 3.343 4.2839 218
DA
-7 267.5 0.3478 18 12 49 21.6 2.4038 123
7B
105 3.15 4.3197 220
DC
-6 253.9 0.3651 19 13 50 20.79 2.4516 125
7D
106 3.059 4.3367 221
DD
-5 241.1 0.3830 20 14 51 20.01 2.4994 127
7F
107 2.97 4.3535 222
DE
-4 229 0.4016 20 14 52 19.26 2.5471 130 82 108 2.884 4.3699 223
DF
-3 217.6 0.4209 21 15 53 18.54 2.5947 132 84 109 2.802 4.3856 224
E0
-2 206.8 0.4409 22 16 54 17.85 2.6420 135 87 110 2.721 4.4012 224
E0
-1 196.6 0.4617 24 17 55 17.19 2.6889 137 89 111 2.721 4.4012 224
E0
0 186.9 0.4833 25 18 56 16.56 2.7352 139
8B
112 2.644 4.4162 225
E1
1 177.8 0.5056 26 19 57 15.96 2.7809 142
8E
113 2.569 4.4309 226
E2
2 169.2 0.5285 27
1A
58 15.38 2.8265 144 90 114 2.496 4.4452 227
E3
3 161 0.5525 28
1B
59 14.82 2.8719 146 92 115 2.426 4.4591 227
E3
4 153.3 0.5770 29
1C
60 14.29 2.9163 149 95 116 2.358 4.4727 228
E4
5 146 0.6024 31
1E
61 13.78 2.9603 151 97 117 2.292 4.4859 229
E5
6 139 0.6289 32
1F
62 13.28 3.0048 153 99 118 2.228 4.4988 229
E5
7 132.5 0.6557 33 21 63 12.81 3.0479 155
9B
119 2.167 4.5112 230
E6
8 126.3 0.6835 35 23 64 12.36 3.0902 158
9E
120 2.107 4.5235 231
E7
9 120.4 0.7123 36 24 65 11.93 3.1319 160
A0
121 2.049 4.5354 231
E7
10 114.8 0.7418 38 26 66 11.51 3.1736 162
A2
122 2.049 4.5354 231
E7
11 109.5 0.7722 39 27 67 11.11 3.2144 164
A4
123 1.994 4.5467 232
E8
12 104.4 0.8039 41 29 68 10.73 3.2541 166
A6
124 1.887 4.5689 233
E9
13 99.66 0.8357 43
2B
69 10.36 3.2938 168
A8
125 1.836 4.5796 234
EA
14 95.13 0.8686 44
2D
70 10 3.3333 170
AA
126 1.787 4.5899 234
EA
15 90.82 0.9024 46
2C
71 9.659 3.3717 172
AC
127 1.739 4.6000 235
EB
16 86.74 0.9369 48
2E
72 9.331 3.4094 174
AE
128 1.693 4.6098 235
EB
17 82.85 0.9723 50 32 73 9.016 3.4464 176
B0
129 1.649 4.6192 236
EC
18 79.16 1.0085 51 33 74 8.712 3.4829 178
B2
130 1.605 4.6286 236
EC
19 75.65 1.0455 53 35 75 8.421 3.5185 179
B3
20 72.32 1.0832 55 37 76 8.14 3.5537 181
B5
21 69.15 1.1217 57 39 77 7.869 3.5882 183
B7
22 66.13 1.1610 59
3B
78 7.609 3.6220 185
B9
23 63.27 1.2009 61
3D
79 7.359 3.6551 186
BA
24 60.54 1.2416 63
3F 80
7.118 3.6876 188
BC
25 57.94 1.2830 65 41 81 6.885 3.7195 190
BE
Page 31
55.. EELLEECCTTRRIICCAALL DDAATTAA
29
2. THE PARAMETER OF THE OTHER SENSOR IN INDOOR AND OUTDOOR UNIT: (R
0
=15K±2%B=3450±2%
T(℃) R(KΩ) V(v) DEC HEX T(℃) R(KΩ) V(v) DEC HEX T(℃) R(KΩ) V(v) DEC HEX
-30 67.94 0.3235 16 10 18 6.962 2.0151 103 67 66 1.297 3.9186 200 C8
-29 64.25 0.3408 17 11 19 6.688 2.0636 105 69 67 1.258 3.9443 201 C9
-28 60.79 0.3588 18 12 20 6.427 2.1120 108 6C 68 1.22 3.9696 202 CA
-27 57.53 0.3776 19 13 21 6.178 2.1603 110 6E 69 1.184 3.9939 204 CC
-26 54.48 0.3971 20 14 22 5.939 2.2089 113 71 70 1.149 4.0178 205 CD
-25 51.6 0.4174 21 15 23 5.712 2.2570 115 73 71 1.116 4.0406 206 CE
-24 48.9 0.4384 22 16 24 5.494 2.3053 118 76 72 1.083 4.0636 207 CF
-23 46.35 0.4603 23 17 25 5.286 2.3533 120 78 73 1.051 4.0862 208 D0
-22 43.96 0.4829 25 19 26 5.086 2.4014 122 7A 74 1.021 4.1077 209 D1
-21 41.7 0.5065 26 1A 27 4.896 2.4489 125 7D 75 0.9914 4.1290 211 D3
-20 39.58 0.5307 27 1B 28 4.714 2.4963 127 7F 76 0.963 4.1497 212 D4
-19 37.58 0.5558 28 1C 29 4.539 2.5436 130 82 77 0.9354 4.1701 213 D5
-18 35.69 0.5818 30 1E 30 4.372 2.5904 132 84 78 0.9088 4.1898 214 D6
-17 33.91 0.6087 31 1F 31 4.212 2.6369 134 86 79 0.8831 4.2091 215 D7
-16 32.23 0.6363 32 20 32 4.059 2.6830 137 89 80 0.8582 4.2280 216 D8
-15 30.65 0.6648 34 22 33 3.912 2.7288 139 8B 81 0.8342 4.2463 217 D9
-14 29.15 0.6942 35 23 34 3.772 2.7738 141 8D 82 0.8109 4.2643 217 D9
-13 27.74 0.7244 37 25 35 3.637 2.8188 144 90 83 0.7884 4.2818 218 DA
-12 26.4 0.7556 39 27 36 3.508 2.8631 146 92 84 0.7666 4.2988 219 DB
-11 25.14 0.7875 40 28 37 3.384 2.9070 148 94 85 0.7455 4.3155 220 DC
-10 23.95 0.8202 42 2A 38 3.265 2.9504 150 96 86 0.725 4.3318 221 DD
-9 22.82 0.8539 44 2C 39 3.151 2.9932 153 99 87 0.7053 4.3476 222 DE
-8 21.75 0.8885 45 2D 40 3.041 3.0358 155 9B 88 0.6861 4.3631 223 DF
-7 20.74 0.9237 47 2F 41 2.936 3.0775 157 9D 89 0.6676 4.3781 223 DF
-6 19.79 0.9596 49 31 42 2.835 3.1188 159 9F 90 0.6496 4.3929 224 E0
-5 18.88 0.9966 51 33 43 2.739 3.1590 161 A1 91 0.6323 4.4071 225 E1
-4 18.02 1.0343 53 35 44 2.646 3.1990 163 A3 92 0.6156 4.4209 225 E1
-3 17.2 1.0731 55 37 45 2.556 3.2387 165 A5 93 0.5993 4.4345 226 E2
-2 16.43 1.1122 57 39 46 2.471 3.2771 167 A7 94 0.5836 4.4477 227 E3
-1 15.7 1.1520 59 3B 47 2.388 3.3155 169 A9 95 0.5683 4.4606 227 E3 0 15 1.1929 61 3D 48 2.309 3.3528 171 AB 96 0.5535 4.4732 228 E4 1 14.34 1.2342 63 3F 49 2.233 3.3896 173 AD 97 0.5391 4.4855 229 E5 2 13.71 1.2765 65 41 50 2.159 3.4262 175 AF 98 0.5251 4.4975 229 E5 3 13.11 1.3195 67 43 51 2.089 3.4615 177 B1 99 0.5115 4.5093 230 E6 4 12.55 1.3623 69 45 52 2.021 3.4965 178 B2 100 0.4983 4.5207 231 E7 5 12.01 1.4063 72 48 53 1.956 3.5306 180 B4 101 0.4855 4.5319 231 E7 6 11.5 1.4506 74 4A 54 1.893 3.5644 182 B6 102 0.4731 4.5427 232 E8 7 11.01 1.4959 76 4C 55 1.832 3.5977 183 B7 103 0.461 4.5534 232 E8 8 10.55 1.5410 79 4F 56 1.774 3.6299 185 B9 104 0.4492 4.5638 233 E9 9 10.1 1.5878 81 51 57 1.718 3.6616 187 BB 105 0.4378 4.5739 233 E9
10 9.684 1.6338 83 53 58 1.664 3.6926 188 BC 106 0.4268 4.5838 234 EA 11 9.284 1.6805 86 56 59 1.612 3.7231 190 BE 107 0.416 4.5934 234 EA 12 8.903 1.7276 88 58 60 1.562 3.7528 191 BF 108 0.4055 4.6029 235 EB 13 8.54 1.7749 91 5B 61 1.513 3.7824 193 C1 109 0.3953 4.6121 235 EB 14 8.194 1.8226 93 5D 62 1.467 3.8106 194 C2 110 0.3854 4.6211 236 EC 15 7.864 1.8704 95 5F 63 1.422 3.8386 196 C4 16 7.549 1.9185 98 62 64 1.379 3.8658 197 C5 17 7.249 1.9667 100 64 65 1.337 3.8927 199 C7
Page 32
55.. EELLEECCTTRRIICCAALL DDAATTAA
30
3. THE PARAMETER OF THE OTHER SENSOR IN INDOOR AND OUTDOOR UNIT: (R
25
=15K±3%;B
25/50
=4100±3%
T(℃) R(KΩ ) V(v ) DE C HEX T(℃)R(KΩ ) V(v) DE C HEX T(℃)R(KΩ) V( v) D EC HEX
-20 154.57 7 0.4 423 23 17 28 12.635 2.7139 138 8A 76 1. 944 4. 4263 226 E 2
-19 145.16 1 0.4 683 24 18 29 12.062 2.7714 141 8D 77 1. 877 4. 4439 227 E 3
-18 136.72 4 0.4 943 25 19 30 11.519 2.8282 144 90 78 1. 814 4. 4606 227 E 3
-17 128.83 5 0.5 214 27 1B 31 11.436 2.8370 145 91 79 1. 753 4. 4768 228 E 4
-16 121.45 5 0.5 496 28 1C 32 10.942 2.8911 147 93 80 1. 694 4. 4926 229 E 5
-15 114.54 8 0.5 789 30 1E 33 10.472 2.9444 150 96
-14 108.08 0 0.6 094 31 1F 34 10.025 2.9970 153 99
-13 102.02 0 0.6 409 33 21 35 9. 6 3.04 88 155 9B
-12 96.34 1 0.6 736 34 22 36 9.196 3.0997 158 9E
-11 91.01 7 0.7 074 36 24 37 8.811 3.1498 161 A1
-10 86.02 2 0.7 424 38 26 38 8.444 3.1991 163 A3
-9 81.334 0.7785 40 28 39 8.095 3.2475 166 A6
-8 76.933 0.8158 42 2A 40 7.763 3.2948 168 A8
-7 72.799 0.8542 44 2C 41 7.446 3.3414 170 AA
-6 68.914 0.8938 46 2E 42 7.144 3.3869 173 AD
-5 65.262 0.9344 48 30 43 6.856 3.4316 175 AF
-4 61.828 0.9762 50 32 44 6.581 3.4753 177 B1
-3 58.597 1.0191 52 34 45 6.319 3.5180 179 B3
-2 55.555 1.0630 54 36 46 6.069 3.5597 182 B6
-1 52.691 1.1080 57 39 47 5.8 3 3.60 06 184 B8 0 49.994 1.1540 59 3B 48 5.602 3.6404 186 BA 1 47.452 1.2009 61 3D 49 5.385 3.6792 188 BC 2 45.055 1.2489 64 40 50 5.177 3.7171 190 BE 3 42.795 1.2977 66 42 51 4.9 7 3.75 56 192 C0 4 40.663 1.3474 69 45 52 4.773 3.7931 193 C1 5 38.650 1.3979 71 47 53 4.585 3.8295 195 C3 6 36.750 1.4493 74 4A 54 4.406 3.8648 197 C5 7 34.956 1.5013 77 4D 55 4.234 3.8993 199 C7 8 33.260 1.5541 79 4F 56 4.071 3.9327 201 C9 9 31.657 1.6075 82 52 57 3.914 3.9653 202 CA
10 30.142 1.6614 85 55 58 3.765 3.9968 204 CC 11 28.709 1.7159 88 58 59 3.622 4.0275 205 CD 12 27.352 1.7709 90 5A 60 3.485 4.0573 207 CF 13 26.069 1.8262 93 5D 61 3.355 4.0861 208 D0 14 24.853 1.8819 96 60 62 3.2 3 4.11 41 210 D2 15 23.702 1.9379 99 63 63 3.1 1 4.14 14 211 D3 16 22.611 1.9941 102 66 64 2.99 6 4.16 76 213 D5 17 21.577 2.0505 105 69 65 2.88 6 4.19 32 214 D6 18 20.597 2.1069 107 6B 66 2.78 1 4.21 80 215 D7 19 19.667 2.1634 110 6E 67 2.68 1 4.24 18 216 D8 20 18.785 2.2199 113 71 68 2.58 4 4.26 52 218 DA 21 17.948 2.2763 116 74 69 2.49 2 4.28 77 219 DB 22 17.153 2.3326 119 77 70 2.40 3 4.30 96 220 DC 23 16.398 2.3887 122 7A 71 2.31 9 4.33 05 221 DD 24 15.681 2.4445 125 7D 72 2.23 7 4.35 11 222 DE 25 15.000 2.5000 128 80 73 2.15 9 4.37 09 223 DF 26 14.326 2.5575 130 82 74 2.08 4 4.39 01 224 E0
27 13.687 2.6144 133 85 75 2.01 3 4.40 84 225 E1
Page 33
66.. CCOONNTTRROOLL MMOODDEEL
L
31
INDOOR CONTROL MODEAMS-07UR4SNZA3AMS-09UR4SNZA3
AMS-12UR4SNZA3AMS-18UR4SPZA3
1.Major general technical parameters
1 Conditionings for operation: Ambient temperatures: (-15 - +45 ), relative humidity (45 - 85%). 2 Remote receiver distance: 8 m. 3 Remote receiver angle: Less than 80 degrees. 4 Temperature control accuracy: ±1. 5 Time error: Less than 1%. 6 The power supply for the air conditioner is a.c 220V240V, 50Hz, with its fluctuation in the range of
(176V – 264 V).
2. Functions of the controller
2.1 Display panel
I. Control functions of the remote controller (See operating and installation manual) II. Display of the indoor unit
The picture of the display is as follows:
Frequency Indoor Tmp. Outdoor Tmp. Timer
III. Displaying Scheme:
1. Timer: Enabled (the “Clock” sign appears), Cancel (the “Clock” sign disappears)
2. Indoor temperature: the “House” sign goes on. and the value is current temperature of indoor. The
range of the value is from “-9” to “35”. Outdoor temperature: the “House” sign goes on. and the value is current temperature of outdoor. The range of the value is from “-19” to “45”. “ ” will displayed when communication of indoor unit and outdoor unit abnormal.
3. Frequency: stand for the speed of compressor.
4. Display of error codes:
An error code will displayed when error occurred. You can show the code by push “H.P.” button on remote controller 5 times. The error code will flash for 5 seconds while displayed. The “House” sign goes on and all other signs go off.
3. Control function
3.1 Emergency switch
1. When the machine is turned OFF, by press and hold the emergency switch for 5 seconds, with 3 beeps ,
the indoor unit would turn to emergency run. In such station, machine would be forced to turn to cooling operation with the indoor fan speed being set at high speed, the flaps sweeping and the air conditioner’s operation is irrelevant with room temperatures.
2. If a remote signal has been received during the emergency run, the machine will operate upon the
command of such a remote signal.
Page 34
66.. CCOONNTTRROOLL MMOODDEEL
L
32
3.2 Operator-machine communication
The air conditioner has a thermal sensor to detect room temperatures. Some remote controller is equipped with a thermal sensor (Such remote controller has the function of man-machine communication. For details, refer to the section for the remote controller). In addition, there is a thermal sensor at the indoor air inlet. In the case where the remote controller is equipped with a thermal sensor, the default setting for room temperatures is subject to the detection by the remote controller. The remote controller detects the room temperature once every 20 seconds, and automatically transmits a signal at an interval of 3 minutes or when a change in the room temperature is detected. If the indoor control unit has not received a remote signal for more than 10 minutes, the control function will be automatically switched over to the thermal sensor on the indoor unit.
3.3 Timer function
1. Timer on: When set to start in a time by the remote controller, the air conditioner starts in the timer on
condition. When the set time is up, the air conditioner will turn on and operates in the preset conditions after receiving a signal from the remote controller. If the air conditioner has not received a signal from the remote controller when the set time is up, it will automatically start and operate in the preset conditions.
2. Timer off: When set to stop in a set time by the remote controller, the air conditioner will start in the timer
off condition. When the set time is up, the air conditioner will turn off after receiving a signal from the remote controller. If the air conditioner has not received a signal from the remote controller when the set time is up, it will turn off automatically.
3. Neither the turning on nor turning off operation will cancel the timer function (Some remote controller has
a simple one-hour timer off function and excludes this operation).
3.4 Sleep
1. In the heating, cooling or dehumidifying mode, press the “Sleep” button on the remote controller to start
or cancel the sleep function in turn, and at the same time the sleep icon on the display screen will be on or off accordingly.
2. In the heating mode, the set temperature will decrease automatically after the sleep function is started.
3. In the cooling mode, the set temperature will rise aotomatically after the sleep function is started.
4. In default, the setting is to cancel the sleep function. Turning off the unit will also cancel the sleep
function.
3.5 High efficient run function
In the heating (except for the cooling-only unit), cooling or dehumidifying mode, it may be set for high efficient run with the indoor fan speed changed to the high efficient fan speed and the compressor operating at the highest frequency as available. If the display screen can display the frequency, the frequency displayed on the screen is up to the maximum. It will restore to the previous run state after 15 minutes operation automatically.
Page 35
66.. CCOONNTTRROOLL MMOODDEEL
L
33
3.9 Cold air prevention
In the heating-run, to prevent the indoor fan from blowing cold air, the indoor fan will stop or run slowly until the coil is warmth.
3.10 Mode interfere
For the reason that all indoor units use one outdoor unit, outdoor unit can only run with same mode(cooling or heating), so, when the mode you set is different from the mode that outdoor is running with, mode interfere occurs. Following shows the mode interfere scene.
cooling dry heating fan cooling √ √ × √ √ --- normal dry × × --- mode interfere heating × × √ × fan × Outdoor unit always run with the mode of first indoor unit that turned on. when the setting mode of
following indoor unit is interfered with it, 3 beeps would be heard, and the indoor unit interfered with the normal running units would turn off automatically.
Page 36
66.. CCOONNTTRROOLL MMOODDEEL
L
34
Outdoor mode control AMW3-24U4SKCAMW4-28U4SKCAMW2-20U4SNC AMW2-16U4SGC
1. Summarization
This direction applies to multi-type and DC variable frequency air conditioner
2. Performance index
1. Voltage scale: 176V~264V,50Hz
2. Storage temperature scale: -40~85
3. Storage humidity scale: PH30%~PH95%
4. Working temperature:-20~85
5. accuracy for temperature control ±0.5
3Control function
Cooling Anti-freeze Protection
To prevent freezing caused by too low temperature of indoor evaporator, the air conditioner will
implement real-time detection over the indoor coil temperature. If the indoor coil temperature is too low, the
compressor will be prohibited from increasing the frequency or decrease the frequency even shut down
automatically
Heating Overload Protection
To prevent system overload caused by excessive pressure in heating operation, the machine will
implement real-time detection over the indoor fan-coil temperature:
If the indoor coil temperature grows higher, the compressor will be prohibited from increasing the
frequency; If the temperature continues to rise, the compressor will decrease the frequency; If the indoor
coil temperature is too high, the compressor will stop working immediately. The compressor then will
reboot after the indoor coil temperature reduces.
Cooling Overload Protection
To prevent system overload due to excessive pressure during cooling operation, the machine will
implement real-time detection over the outdoor condenser coil temperature:
If the outdoor coil temperature grows higher, the compressor will be prohibited from increasing the
frequency; If the temperature continues to rise, the compressor will decrease the frequency; If the outdoor
fan-coil temperature is too high, then the compressor will stop working immediately. The compressor will
reboot after the outdoor coil temperature reduces.
Discharge Temperature Protection
To prevent working conditions of compressor from deteriorating due to high discharge temperature,
the machine will implement real-time detection over the discharge temperature.
If the discharge temperature grows higher, the compressor will be prohibited from increasing the
frequency; if the temperature continues to rise, the compressor will decrease the frequency automatically;
if the discharge temperature is too high, the compressor will stop working immediately. The compressor
will then reboot when the discharge temperature returns to normal condition.
Page 37
66.. CCOONNTTRROOLL MMOODDEEL
L
35
Oil-return Control
When the compressor continues to operate at low frequency, there will be an oil return. The
compressor increases the frequency, and thus to return the oil in refrigerate system to the
compressor.
Operation Mode
1 Mode Categories
Air conditioning mode is the operation mode set by users through remote controller, four modes are
available: cooling, heating, dehumidification, as well as fan mode.
2 Mode conflict
The operating mode of outdoor unit is decided by the operating mode of the indoor unit firstly booted.
Indoor unit subsequently booted will firstly determine whether it’s own mode is conflict with the outdoor
mode. If so, the indoor unit will automatically shut down after three beeps; If there is no conflict, the indoor
unit will boot normally. The relationship of mode conflict is as follows:
Driven choice
Active mode
Cooling Dehumidification Heating fan
Cooling ×
Dehumidification ×
Heating × × ×
fan ×
√―――Mode conflict will not happen ×―――
Mode conflict will happen
Outdoor four-way Valve Control
Four-way valve of the outdoor machine shuts down when cooling but starts when heating. The
operation of heating defrosting refers to defrosting operation and, when the heating remote shutdown, the
four-way valve disconnects in 50s when the compressor stops working.
Start-up Protection:
To prevent compressor from restart frequently in the condition that system pressure has not been
completely balanced, it can’t be restarted within 3 minutes.
Pressure Protection:
Pressure switch is normally kept open. When the pressure grows too high, the pressure switch will
close and soft will enter pressure protection control. soft will automatically decrease the frequency. If the
pressure is still unable to return to normal condition after decreasing frequency, compressor will stop and
report the fault code of pressure protection.
Page 38
66.. CCOONNTTRROOLL MMOODDEEL
L
36
Fault code 1:
If the unit reports the following fault code, compressor will stops, and the unit can’t be
operated until the failure is eliminated:
5 Communication fault with IPM
6 Suction sensor fault
7 Discharge sensor fault
8 Top of the compressor sensor fault
9 Outdoor coil temperature sensor fault
10 Defrosting sensor fault
11 Outdoor temperature sensor fault
12 Liquid pipe sensor on valve A fault
13 Liquid pipe sensor on valve B fault
14 Liquid pipe sensor on valve C fault
15 Liquid pipe sensor on valve D fault
16 Gas pipe sensor on valve A fault
17 Gas pipe sensor on valve B fault
18 Gas pipe sensor on valve C fault
19 Gas pipe sensor on valve D fault
20 Current sensor fault
21 Voltage sensor fault
23 Emergency shutdown for discharge temperature abnormal
24 Emergency shutdown for current abnormal
25 Indoor unit A boot fault for freeze protection
26 Indoor unit B boot fault for freeze protection
27 Indoor unit C boot fault for freeze protection
28 Indoor unit D boot fault for freeze protection
29 Shut down for mode conflict
30 Emergency shutdown for IPM failure
31 Emergency shutdown for cooling overload
32 Emergency shutdown for discharge pressure is too high
33 Indoor ambient temperature sensor fault
34 Indoor coil temperature sensor fault
36 Communication fault with indoor unit 37 Condensate in indoor unit is overflow
38 EEPROM of indoor unit error
39 Indoor fan motor fault
41 Indoor AC zero-crossing detection fault
Page 39
66.. CCOONNTTRROOLL MMOODDEEL
L
37
Fault code 2:
if the unit reports the following fault code, the indoor unit which fault will be seen as
shutdown, while other indoor units can operate normally.
1 A Communication Fault
2 B Communication Fault
3 C Communication Fault
4 D Communication Fault
22 EEPROM of outdoor unit fault (the unit will operate in accordance with the
default value)
40 Freeze protection or high-temperature protection of indoor unit A.
41 Freeze protection or high-temperature protection of indoor unit B.
42 Freeze protection or high-temperature protection of indoor unit C.
43 Freeze protection or high-temperature protection of indoor unit D.
Limit code: When compressor run, limited frequency or decreasing frequency code is as follows:
1 Frequency forbid by discharge temperature control
2 Frequency forbid by current control
3 Frequency forbid for coil temperature control of indoor unit A
4 Frequency forbid by coil temperature control of indoor unit B
5 Frequency forbid by coil temperature control of indoor unit C
6 Frequency forbid by coil temperature control of indoor unit D
7 TBD
8 Frequency decrease by discharge temperature control
9 Frequency decrease by current control
10 TBD
11 Frequency decrease by coil temperature control of indoor unit A
12 Frequency decrease by coil temperature control of indoor unit B
13 Frequency decrease by coil temperature control of indoor unit C
14 Frequency decrease by coil temperature control of indoor unit D
15 Frequency decrease by IPM
16 Frequency decrease for outdoor overload in cooling mode.
17 Valve opening-control by DSH(or SSH) control
18 Valve closing-control by DSH(or SSH) control
19 Forbid close valve by DSH(or SSH) control
20 Forbid open valve by DSH(or SSH) control
21 Frequency forbid for cooling overload
22 Frequency forbid by IPM
23 Frequency decrease for discharge pressure is too high.
Page 40
77.. TTRROOUUBBLLEE SSHHOOOOTTIINNGG
38
7-1. Trouble alarm
7-1-1.To display error code(AMS-07UR4SNZA3、AMS-09UR4SNZA3、AMS-12UR4SNZA3
AMS-18UR4SPZA3):
When error occurred, error code can be displayed on the screen of indoor unit through remoter or emergency switch. To display the error code, refer to the following:
Usage1press “high power” button(or “H.P” button) on remote controller for 5 times. Usage2press the emergency switch for over 5 seconds
Indoor or outdoor error codes will be displayed at the displaying area for indoor temperature(“house” area).
7-1-2 When compressor is stop for some trouble, the trouble code will display on LED screen in outdoor unit. To resolve the trouble, please refer to the following:
Error code troubles Possible cause
5 Communication fault with IPM a) to check the cable between control board
and IPM
b) IPM fault
6 Suction sensor fault suction sensor may be short-circuited or
disconnected.
7 Discharge sensor fault discharge sensor may be short-circuited or
disconnected.
8 Top of the compressor sensor fault Top of the compressor sensor may be
short-circuited or disconnected.
9 Outdoor coil temperature sensor
fault
Coil temperature sensor may be short-circuited or disconnected.
10 Defrosting sensor fault Defrosting sensor may be short-circuited or
disconnected.
11 Outdoor temperature sensor fault Outdoor temperature sensor may be
short-circuited or disconnected. 12 Liquid pipe sensor on valve A fault 13 Liquid pipe sensor on valve B fault 14 Liquid pipe sensor on valve C fault 15 Liquid pipe sensor on valve D fault
a) Liquid pipe sensor may be short-circuited
or open-circuited or disconnected.
b) The control board in outdoor unit is in
trouble
16 Gas pipe sensor on valve A fault 17 Gas pipe sensor on valve A fault 18 Gas pipe sensor on valve A fault 19 Gas pipe sensor on valve A fault
a) Gas pipe sensor may be short-circuited or
open-circuited or disconnected.
b) The control board in outdoor unit is in
trouble
20 Current sensor fault The outdoor PCB board in trouble. 21 Voltage sensor fault The outdoor PCB board in trouble. 23 Emergency shutdown for discharge c) check discharge sensor
Display indoor and outdoor error
Page 41
77.. TTRROOUUBBLLEE SSHHOOOOTTIINNGG
39
temperature overheat. d) check whether the strainer before expand
valve is blocked.
e) Freon is leaking. 24 Emergency shutdown for current
overload.
a) Normal protection
b) The outdoor board in trouble. 25 Indoor unit A boot fault for freeze
protection
a) Expand valve A is damaged (leaking).
b) The coil temperature sensor in indoor unit
A is fault.
26 Indoor unit B boot fault for freeze
protection
a) Expand valve B is damaged (leaking).
b) The coil temperature sensor in indoor unit
B is fault.
27 Indoor unit C boot fault for freeze
protection
a) Expand valve C is damaged (leaking).
b) The coil temperature sensor in indoor unit
C is fault.
28 Indoor unit D boot fault for freeze
protection
a) Expand valve D is damaged (leaking).
b) The coil temperature sensor in indoor unit
D is fault.
30 Emergency shutdown for IPM failure a) Normal protec tion for compressor’s
overload.
b) IPM board is fault. 31 Emergency shutdown for cooling
overload.
a) Normal protection for coil temperature
sensor in outdoor is too high. b) Coil temperature sensor in outdoor is fault. c) Freon system may be abnormal if this fault
is occur frequently
32 Emergency shutdown for discharge
pressure is too high
a) The fan inlet of outdoor is blocked in
cooling mode. b) The fan inlet of indoor unit is blocked in
heating mode. c) Freon system may be blocked d) The surroundings temperature of indoor or
outdoor unit is too high.
Page 42
88.. CCHHEECCKKIINNGG CCOOMMPPOONNEENNTTSS
40
8-1. Check refrigerant system
TEST SYSTEM FLOW
Conditions: Compressor is running.
The air condition should be installed in good ventilation. Tool: Pressure Gauge Technique: see feel test
SEE ----- Tube defrost. FEEL ----- The difference between tube’s temperature. TEST ----- Test pressure.
cooling run heating run
Lo Hi
Pressure gauge
Lo Hi
Pressure gauge
Lo Hi
Pressure gauge
Lo Hi
Pressure gauge
Lo Hi
Pressure gauge
Lo Hi
Pressure gauge
Page 43
88.. CCHHEECCKKIINNGG CCOOMMPPOONNEENNTTSS
41
Test system flow
Cooling mode
Test system
pressure.Does the low
pressure normal at
service part ?
The pressure on the high side.
The pressure on the low side.
Recharge refrigerant
after air purging with
the vacuum
pump.Does the low
pressure nomal over
again?
Air remaining at the refrigerant system.
yes
The system wants
refrigerant.The service
people must be ration
refrigerant(about 100g/
per)in the cooling
mode fixed
frequency.Is the low
pressure rise ?
NO
Recharge refrigerant .
yes
The refrigerant system
blocked.Please check the Capillary Tube( or
electronic expansion
valve)Is it blocked?
Unsolder the capillary tube ASS'Y(or electronic expansion valve).The capillary tube1 is blown by N
2
.
Check check valve and 4­way valve.
If the pressure is
close to static
pressure?
NO
NO
4-way valve collude or compressor exhaust very ebb.
yes
NO
yes
Heating mode
Test system pressure.Does the high pressure normal at service part ?
The pressure on the high side.
The pressure on the low side.
Recharge refrigerant after air purging with the vacuum pump.Does the high pressure normal over again?
Air remaining at the refrigerant system.
yes
The system wants refrigerant.The service people must be ration refrigerant(about 100g/
per)in cooling mode fixed frequency state .Is the
high pressure rise in heating mode?
NO
Recharge refrigerant
yes
If the pressure is close to static pressure?
4-way valve collude or compressor exhaust every ebb.
yes
Check heat exchanger and 4-way valve.
NO
The capillary tube blocked.Unsolder the capillary tube ASS'Y.The capillary tube1 and capillary tube2 is blown by N
2
.
NO
Remove the back panel."see"the capillary tube1 and capillary tube2.Is it defrosting?
yes
NO
Page 44
88.. CCHHEECCKKIINNGG CCOOMMPPOONNEENNTTSS
42
8-2.Check parts unit
1. INDOOR FAN MOTOR
.MOTOR EXAMINE AND REPAIR
Circuit diagram 1YYW16-4-532
BLACK
WHITE
M
A
Vcc
GND Vout
BROWN
BLACK
YELLOW
WINDIN G
"" ""
M The main wind in g A The auxiliary winding
Capaci t or
Hot protector 100
2YYW28-4-2085
Test in resistance.
TOOL: Multimeter. Test the resistance of the main winding. The indoor fan motor is fault if the resistance of main winding 0(short circuit)or∞(open circuit).
Test in voltage
TOOL: Multimeter.
Insert screwdriver into to rotate indoor fan motor slowly for 1 revolution or over, and measure
voltage “YELLOW” and “GND” on motor. The voltage repeat 0V DC and 5V DC.
Notes:
1) Please don’t hold motor by lead wires.
2) Please don’t plug IN/OUT the motor connecter while power ON.
3) Please don’t drop hurl or dump motor against hard material. Malfunction may not be observed at
early stage after such shock. But it may be found later, this type of mishandling void our warranty.
2. OUTDOOR FAN MOTOR
MOTOR EXAMINE AND REPAIR Circuit diagram
1) YDK70-6H-3:
BROWN
WHITE
BLACK
RED
BLACK
WHITE
Page 45
88.. CCHHEECCKKIINNGG CCOOMMPPOONNEENNTTSS
43
BROWN
WHITE
A
M
WINDIN G
"" ""
MThemainwinding A The a uxiliary wi n di n g
Capacitor
Hot pr otecto r 130
YELLOW
RED
BLACK
BLUE
Winding resistance ( at 20℃) M: 78Ω A: 80Ω
2) YDK55-6I-8:
Hot Protector 130℃
Capacitor
"A"-The Auxiliary Winding
"M"-The Main Winding
TP
Winding
C
PINK
YELLOW
PURPLE
WHITE
BROWN
A3A2A1
M
Winding resistance ( at 20℃) M: 185Ω A: 200Ω
3) YDK29-6I-22:
Hot Protector 130℃
Capacitor
"A"-The Auxiliary Winding
"M"-The Main Winding
TP
Winding
C
PINK
YELLOW
PURPLE
WHITE
BROWN
A3A2A1
M
Winding resistance ( at 20℃) M: 283.5Ω A: 180Ω
Test in resistance.
TOOL: Multimeter. Test the resistance of the main winding. The outdoor fan motor is fault if the resistance of main winding 0(short circuit)or∞(open circuit).
Notes:
1) Please don’t hold motor by lead wires. 2 Please don’t plug IN/OUT the motor connecter while power ON. 3 Please don’t drop hurl or dump motor against hard material. Malfunction may not be observed at
early stage after such shock. But it may be found later, this type of mishandling void our warranty.
Page 46
88.. CCHHEECCKKIINNGG CCOOMMPPOONNEENNTTSS
44
3. COMPRESSOR
Coil Resistance(JUS1015D5at 25): 0.66Ω(U-V), 0.66Ω(V-W), 0.64Ω(W-U) Coil Resistance(SNB130FGYMat 20): 0.58Ω(U-V), 0.58Ω(V-W), 0.58Ω(W-U) COMPRESSOR EXAMINE AND REPAIR
DC INVERTER
CONTROLLER
&
RU
()
SV
()
TW
()
POWER
Test in resistance.
TOOL: Multimeter. Test the resistance of the winding. The compressor is fault if the resistance of winding 0(short circuit)or∞(open circuit)
Familiar error:
1Compressor motor lock. 2Discharge pressure value approaches static pressure value . 3Compressor motor winding abnormality.
Notes
1Don’t put a compressor on its side or turn over.
2) Please assembly the compressor in your air conditioner rapidly after removing the plugs. Don’t place the comp. In air for along time.
3Avoiding compressor running in reverse caused by connecting electrical wire incorrectly. 4Warning! In case AC voltage is impressed to compressor, the compressor performance will
below because of its rotor magnetic force decreasing.
4. INDUCTANCE
Familiar error:
1Sound abnormality 2Insulation resistance disqualification.
5. STEP MOTOR
5
4
2
1
Test in resistance.
TOOL: Multimeter. Test the resistance of winding. The stepper motor is fault if the resistance of winding 0(short
Page 47
88.. CCHHEECCKKIINNGG CCOOMMPPOONNEENNTTSS
45
circuit)or∞(open circuit.
6. FUSE
Checking continuity of fuse on PCB ASS’Y.
1) Remove the PCB ASS’Y from the electrical component box. Then pull out the fuse from the
PCB ASS’Y (Fig.1)
Fuse
PCB Ass'Y
Fig.1
2) Check for continuity by a multimeter as shown in Fig.2.
Fuse
Fig.2
7.CAPACITOR
1) Remove the lead wires from the capacitor terminals, and then place a probe on the
capacitor terminals as shown in Fig.3.
2) Observe the deflection of the pointer, setting the resistance measuring range of the
multimeter to the maximum value.
* The capacitor is “good” if the pointer bounces to a great extent and then gradually returns to
its original position.
* The range of deflection and deflection time differ according to the capacity of the capacitor.
Compressor motor capacitor
Fan motor capacitor
Multimeter
Fig.3
Page 48
99.. PPAARRTTSS LLIISSTT
46
9-1. IndoorAMS-07UR4SNZA3AMS-09UR4SNZA3AMS-12UR4SNZA3
2
1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17 1-
17 2-
17 3
-
17 4
-
17
18
19
20
21
23
22
25
26
27
28
29
30
24
Page 49
99.. PPAARRTTSS LLIISSTT
47
KEY NO. PART CODE PART NO. DESCRIPTION Q'TY NOTE
1
1302820
RZA-2-1503-031-02-0
ORNAMENT
1
2
1203298
RZA-2-1601-086-XX-0
FRONT PANEL
1
3
1203547
RZA-0-2307-006-XX-0
AIR FILTER ASS'Y
2
4
1203444
RZA-2-2258-062-XX-1
DISPLAY PANEL
1
5
1203267
RZA-2-1501-053-XX-0
GRILL
1
6
1203645
RZA-2-2369-067-XX-0
LEFT DOWN COVER
1
7
1203646
RZA-2-2369-068-XX-0
RIGHT DOWN COVER
1
8
1301490
RZA-0-0051-011-XX-0
EV APORA TOR ASS'Y
1
9
1203331
RZA-2-2219-043-XX-0
EVAPORATOR BRACKET
1
10
1203664
RZA-2-2514-113-XX-0
MOTOR COVER
1
11
1201217
RZA-0-5259-093-XX-0
INDOOR SENSOR ASS'Y
1
12
1205017
4-5259-332-03-0
COIL SENSOR ASS'Y
1
13
1203072
RZA-0-2510-106-XX-1
BEARING ASS'Y
1
14
1203663
RZA-2-2509-123-XX-0
CROSS-FLOW FAN ASS'Y
1
15
1200849
RZA-0-0000-116-XX-0
FAN MOTOR ASS'Y
1
16
1203287
RZA-2-1523-056-XX-0
FLAP
1
17
1203747
RZA-0-2201-129-01-0
BASE ASS'Y
1
17-1
1203271
RZA-2-2231-012-01-0
BASE
1
17-2
1203609
RZA-2-1519-037-01-0
BLADE
2
17-3
1203661
RZA-2-2478-112-XX-0
FLAP FIXED PLATE
2
17-4
1203627
RZA-2-2360-004-XX-0
INNER FLAP
1
18
1202992
RZA-0-1303-102-XX-0
DRAINAGE HOSE ASS'Y
1
19
1200855
RZA-0-0000-144-XX-0
STEPPER MOTOR
1
20
1200177
RZA-0-5152-062-XX-0
DISPLAY BOARD ASS'Y
1
21
1203590
RZA-2-2348-005-XX-0
DRAINAGE PLUG
1
22
1204031
RZA-2-2514-112-XX-0
BEARING COVER
1
23
1203639
RZA-2-2362-032-XX-0
FIXED BOARD
1
24
1203356
RZA-2-2230-114-XX-0
INSTALLATION PLATE
1
25
1380530
K36210260
REMOTE CONTROLLER
1
26
1203207
RZA-0-5315-023-XX-0
ELECTRICAL CONTROL BOX COVER
1
1380560
K36412212
AMS-07UR4SNZA3 AMS-09UR4SNZA3
27
1380576
K36412213
PCB BOARD ASS'Y 1
AMS-12UR4SNZA3
28
1203964
RZA-2-5307-051-01-1
ELECTRICAL CONTROL BOX
1
29
1203961
RZA-2-5304-016-01-2
CLIP
1
30
1304376
4-2379-123-02-0
TERMINAL BOARD ASS'Y
1
Page 50
99.. PPAARRTTSS LLIISST
T
48
9-4. Indoor AMD-09UX4SJC/AMD-12UX4SJC/AMD-18UX4SJC
1
2
3
6
7
10
12
14
13
16
15
17
18
23
25
24
22
21
26
27
28
29
35
4
5
9
8
11
19
20
32
30
31
33
34
36
37
Page 51
99.. PPAARRTTSS LLIISST
T
49
KEY NO.
PART CODE PART NO. DESCRIPTION Q'TY NOTE
1 1360499 K33AD0058 OUTLET FOAM 1 2 1360552 K33130037 STRENGTHEN PLATE 1
1360605 K37320195 1
A
MD-09UX4SJC
A
MD-12UX4SJC
3
1379028 K37320219
EVAPORATOR
1
A
MD-18UX4SJC
4 1360786 K31710020 UPPER BOARD 1 5 1360942 K33450017 SPACER 1 6 1360670 K33AD0060 FOAM 1 7 1360677 K31220094 SIDE PANEL 1 8 1360763 K33170068 CONNECTING PLATE 1
9 1360484 K31120120 BASE PARTS 1 10 1360719 K33160040 MOUNTING PLATE ASSY 1 11 1360729 K331F0046 MOTOR BRACKET 1
1362138 K1B310196 1
A
MD-09UX4SJC
A
MD-12UX4SJC
12
1380538 K1B310248
MOTOR
1
A
MD-18UX4SJC
13 1360737 K34340017 CARD HOOK 2 14 1360739 K38210035 CENTRIFUGAL FAN 2 15 1360830 K31640038 AIR INLET PARTS 1 16 1354576 K31710019 UPPER BOARD 1 17 1360744 K38530022 FAN SNAIL SHELL 2 18 1360745 K38530023 FAN SNAIL SHELL 2 19 1360629 K31210037 SIDE PANEL PARTS 1 20 1360760 K33170067 CONNECTING PLATE 1 21 1360831 K338A0216 COVER 1 22 1361036 K31220095 SIDE PANEL 1 23 1360633 K33A40513 SPONGE 1 24 1202700 RZA-2-2295-001-01-0 CLAMP 1 25 1360771 K33540055 ELECTRICAL BOX 1 26 1361768 K33650021 SEPTA 1
1378275 K36412188 1
A
MD-09UX4SJC
1362146 K36412043 1
A
MD-12UX4SJC
27
1380540 K36412211
PCB BOARD
1
A
MD-18UX4SJC
28 1225513 141111 FAN MOTOR CAPACITOR 1 29 1360766 K33840029 ELEC JOINT BOX COVER 1 30 1313577 K13530006 TRANSFORMER 1 31 1359593 K36E10045 TERMINAL BOARD ASS'Y 1 32 1302207 RZA-2-2397-009-XX-0 RUBBER LID 2
Page 52
99.. PPAARRTTSS LLIISST
T
50
33 1363753 DG19R1-21
TEMPERATURE SENSOR
1
1262330 KT21J6-30(D) 1
A
MD-09UX4SJC
1262396 KT21P5-20 1
A
MD-12UX4SJC
34
1262444 KT21P6-54
CONNECTING WIRE
1
A
MD-18UX4SJC
35 1360539 K33130036 STRENGTHEN PLATE 1 36 1381967 K33160044 MOUNTING BRACKET FOR PUMP 1
Selection
p
art
37 1382293 K1B410005 CONDENSATE PUMP 1
Selection
p
art
Page 53
99.. PPAARRTTSS LLIISST
T
51
19
76
29
27
28
30
25
26
23
22
21
20
18
17
16
15
14
13
10
6
5
1
2
3
11
8
7
9
12
4
35
32
34
33
36
37
39
40
T-dis
38
Green
Blue
Black
Yellow
Yellow
73
74
Red
75
White
31
9-2. Outdoor AMW3-24U4SKCAMW4-28U4SKC 9-2-1. Parts
1. Configuration parts
Page 54
99.. PPAARRTTSS LLIISST
T
52
2. System parts
49
50
48
51
52
53
54
55
57
60
65
59
72
41
45
42
43
46
47
61
44
68
70
58
71
Page 55
99.. PPAARRTTSS LLIISST
T
53
9-2-2. List
KEY NO. PART CODE PART NO. DESCRIPTION Q'TY NOTE
1 1202500 RZA-0-1321-003-XX-0 FAN GUARD ASSY 1
1202383 RZA-2-1112-004-XX-0 AMW3-24U4SKB
2
1312026 K31470022
FRONT PANEL 1
AMW4-28U4SKB 3 1202381 RZA-0-1112-005-XX-0 RIGHT PANEL ASSY 1 4 1202703 RZA-2-2303-001-XX-0 HANDLE 2 5 1202610 RZA-2-2228-002-XX-0 DRAINAGE HOSE 1
1353088 K31120103 1 AMW3-24U4SKB
6
1353043 K31120099
BASE ASSY
1 AMW4-28U4SKB 7 1328932 T-2-2502-033-XX-0 PROPELLER FAN 1 8 1301883 RZA-0-0000-057-XX-1 FAN MOTOR ASSY 1 9 1202442 RZA-0-2506-003-XX-1 FAN SUPPORTER ASSY 1
10 1202474 RZA-0-2309-012-XX-0 TOP COVER ASSY 1 11 1302261 RZA-4-2649-069-XX-0 REACTOR 1 12 1335623 K33660021 PARTITION SUPPORT PLA TE 1 13 1202234 RZA-2-2431-005-XX-0 RUBBER BLOCK 1 14 1204976 RZA-0-1111-001-XX-2 BACK GUARD ASSY 1 15 1301634 RZA-0-1115-001-XX-0 SIDE PANEL ASSY 1 16 8001840 RZA-2-2369-137-XX-0 VALVE COVER 1 17 8001549 RZA-2-5307-148-XX-0 ELECTRICAL BOX 1 18 1377855
K364A0012
FIL TER BOARD 1 19 1317464 K13410005 FILTER 1 20 1202889 RZA-0-2239-023-XX-0 FAN MOTOR CAPACITOR 1 21 1304655 RZA-4-2239-090-XX-0 AL ELECTROANALYSIS CAPACITOR 1 22 1202283 RZA-2-5301-002-XX-0 CAPACITORY CLIP 1 23 1354460 K36470112 DUMMY 1 25 1356881 K33AE0021 RADIATOR 1 26 8006825 K33530023 ELECTRICAL BOX 1
1354436 K36411951 1 AMW3-24U4SKC
27
1354439 K36411952
CONTROL BOARD
1 AMW4-28U4SKC 28 8001822 RZA-2-5307-147-XX-0 ELECTRICAL BOX 1 29 1356966 K33120022 MOUNT PLATE ASSY 1 30 1206639 RZA-2-9030-012-XX-0 CLIP 5** 31 1301881 4-2379-123-03-0 TERMINAL PANEL 4* 32 1200212 RZA-0-2216-002-XX-0 FUSE BRACKET 1 33 1200211 RZA-0-2349-007-XX-0 FUSE 1 34 1311469 K33AB0005 NOISE DEFENING COVER 1 35 1204958 RZA-2-5303-054-XX-0 SENSOR MOUNT 1
Page 56
99.. PPAARRTTSS LLIISST
T
54
36 1301839 4-5259-390-04-0 TEMPERATYRE SENSOR 1 37 1301832 4-5259-390-02-0 TEMPERATYRE SENSOR 1 38 1301833 4-5259-390-03-0 TEMPERATYRE SENSOR 1 39 1301841 4-5259-390-05-0 TEMPERATYRE SENSOR 1 40 1301842 4-5259-290-01-0 TEMPERATYRE SENSOR 1 41 1300307 RZA-0-4519-021-XX-0 ELECTRONIC EXPANSION VALVE 4* 42 1300208 RZA-2-4221-623-XX-0 1/4 TUBE 4* 43 1302908 RZA-0-4515-00B-42-0 1/4' SERVICE VALVE 4* 44 1203230 RZA-2-2475-017-XX-0 INSULATION CUSHION 4* 45 1300204 RZA-0-4206-982-XX-0 STAINER ASS’Y 4* 46 1302912 RZA-0-4518-00B-42-0 3/8 SERVICE VALVE 4* 47 1301297 RZA-2-4223-067-XX-0 3/8 TUBE 4*
1357788 K37410398 1 AMW3-24U4SKC
48
1357737 K37410397
5/8" TUBE ASS'Y
1 AMW4-28U4SKC 49 1203402 RZA-0-4505-008-XX-0 STRAINER 1
1300205 RZA-0-4114-001-XX-0 1 AMW3-24U4SKC
50
1307360 RZA-0-4207-075-XX-0
DISTUIBUTOR ASS'Y
AMW4-28U4SKC 51 1300179 RZA-0-4206-985-XX-0 DISTUIBUTOR ASS'Y 1 52 1300178 RZA-0-4206-977-XX-0 DISTUIBUTOR ASS'Y 1 53 1357728 K37460146 CONDENSER INLET ASS"Y 1 54 1300184 RZA-2-4118-001-XX-0 CONDENSER OUTLET TUBE 1 55 1258657 DG26D2-01(A) 4-WAY VA LVE 1 57 1357312 K37450053 SUCTION PIPE 1 58 1206624 RZA-0-9507-013-XX-0 PRESSURE SWITCH 1 59 1357614 K37440100 DISCHARGE PIPE 1 60 1205562 RZA-2-2475-001-XX-0 CUSHION RUBBER 1
1357284 K37330218 1 AMW3-24U4SKC
61
1357849 K37330219
CONDENSER ASS'Y
1 AMW4-28U4SKC 65 1358918 K37210164 COMPRESSOR ASS'Y 1 68 1300250 RZA-2-2476-176-XX-0 SOUND INSULATION PAD 1 70 1205547 RZA-2-2476-135-XX-0 SOUND INSULA TION PA D 1 71 1324503 K33AB0034 SOUND INSULATION PAD 1 72 1301887 RZA-4-2649-081-XX-0 EEV COIL 4* 73 8006239 K1C070004 INSULATION PAD 2
74*** 1312582 K1C510001 TEMPERATYRE SENSOR 1 75*** 1312591 K1C510002 TEMPERATYRE SENSOR 1
76 1304193 RZA-0-5306-027-XX-1 TERMINAL PANEL 1
Note:
Page 57
99.. PPAARRTTSS LLIISST
T
55
* For AMW3-24U4SKC, the quantity is 3 instead of 4 ** For AMW3-24U4SKC, the quantity is 4 instead of 5 *** The item is only for AMW4-28U4SKC.
Page 58
99.. PPAARRTTSS LLIISST
T
56
9-3. Outdoor AMW2-20U4SNC
2
3
4
5
6
7
26
27
21
20
8
13
15
37
24
1
19
35
34
32
31
30
29
28
9
14
17
10
11
12
16
22
23
33
25
18
39
41
40
Page 59
99.. PPAARRTTSS LLIISST
T
57
KEY NO.
PART CODE PART NO. DESCRIPTION Q'TY NOTE
1 1202499 RZA-2-1321-002-XX-0 FAN GUARD 1 2 8004546
K31470066
FRONT PANEL 1
3 1324263
K38310006
PROPELLER FAN 1
4 1323471
K1B310044
FAN MOTOR ASSY 1
5 1333872
K331F0030
FAN MOTOR SUPPORTER 1 6 1327595 K37340102 CONDENSER ASSY 1 7 8004547
K31220010
BACK PANEL 1 8 1202470 RZA-0-5302-003-XX-0 SIDE COVER ASSY 1 9 1206659 RZA-2-2369-001-XX-1 VALVE COVER 1
10 1300307 RZA-0-4519-021-XX-0 ELECTRICAL EXPANSION VALVE 2
11
1349489 K37410374
4-WAY VALVE 1 12 1204863 RZA-0-4515-01B-41-0 1/4 VALVE ASSY 2 13 1204849 RZA-0-4518-02B-41-0 3/8 VALVE ASSY 2 14
1301842 4-5259-290-01-0
TEMPERATURE SENSOR 1
15
1341332 K37210142
COMPRESSOR ASSY 1 16 1301839 4-5259-390-04-0 TEMPERATURE SENSOR 1 17 1301842 4-5259-290-01-0 TEMPERATURE SENSOR 1 18
1312582 K1C510001
TEMPERATURE SENSOR 1 19 1204958 RZA-2-5303-054-XX-0 SENSOR MOUNT ASSY 1 20
1303873 RZA-2-2476-196-XX-0
NOISE DEFENING COVER(1) 1
21
1312877 K33AB0008
NOISE DEFENING COVER(2) 1
22
1334747 K33AB0045
NOISE DEFENING COVER(3) 1
23
1349535 K31120094
BASE ASSY 1 24 1204014 852-2-2228-132-02-0 DRAINAGE HOSE 1 25 1324726
K31720005
COVER 1
26 1205797
RZA-4-2649-066-XX-0
INDUCT ANCE ASSY 1
27 1324836
K33670006
PARTITION SUPPORT PLATE ASSY 1 28 1205734 RZA-0-2239-010-XX-0 Al ELECTROANALYSIS CAPACITOR 1 29 1304089 RZA-2-5304-092-XX-0 CLIP 3 30 1301881
4-2379-123-03-0
TERMINAL PANEL ASSY 2 31 1304193 RZA-0-5306-027-XX-1 TERMINAL PANEL ASSY 1 32
1340852 K33540024
ELECTRICAL BOX 1 33 1305257 RZA-0-5220-024-XX-0 FILTER 1 34 1327865 K36410802 CONTROL BOARD ASSY 1 35 1334466 K33AE0009 RADIATOR 1 37 1332616 K36470072 IPM ASSY 1 39
1202283 RZA-2-5301-002-XX-0
fixing clip 1
40
1324503 K33AB0034
NOISE DEFENING COVER(3) 1
41
1311770 K33AB0007
NOISE DEFENING COVER(3) 1
Page 60
99.. PPAARRTTSS LLIISST
T
58
9-3. Outdoor AMW2-16U4SNC
Page 61
99.. PPAARRTTSS LLIISST
T
59
KEY NO.
PART CODE PART NO. DESCRIPTION Q'TY NOTE
1 1203960
852-2-1321-156-01-0 FAN GUARD 1
2 1203959
RZA-2-1112-024-XX-0 FRONT PANEL 1
3 1317536
K38310004
PROPELLOR FAN 1
4 1354934
K1B310187 FAN MOTOR ASSY 1
5 1204938
RZA-2-2354-023-XX-0 FAN SUPPORTER 1
6 1203635
RZA-2-2208-025-XX-0
STRENGTHEN PANEL 1
7 1353542
K37340257 CONDENSER ASSY 1
8 1203956
RZA-0-2309-040-XX-0 TOP COVER ASSY 1
9
1353370 K31220091 SIDE PANEL 1
10
1353367 K33810034 WIRING DISTRIBUTION COVER ASSY 1
11
1354044 K33880006 VALVE COVER 1
12 1301088
RZA-0-4509-015-XX-0 4-WAY VALVE 1
13 1332693
RZA-0-4515-00B-41-0 1/4 VALVE ASSY 1
14 1335015
RZA-0-4518-00B-41-0 3/8 VALVE ASSY 1
15 1315560
RZA-0-5303-052-XX-0 SENSOR BRACKET 1
16
1300307 RZA-0-4519-021-JT -0 ELECTRIC EXPANSION VALVE 2
17 1206640
RZA-4-2649-074-XX-0 ELECTROMAGNETIC COIL 1
18 1204048
RZA-0-5302-011-XX-1 ELECTRICAL BOX ASSY 1
19 1354179
K36411936 CONTROL BOARD 1
20 1301881
4-2379-123-03-0 TERMINAL PANEL 2
21
1206639 RZA-2-9030-012-XX-0 CLIP ASSY 3
22
1353381 K33170065 TERMINAL BOARD ASSY 1
23 1305257
RZA-0-5220-024-XX-0
EMI FILTER
1
24 1315782
K33530007 ELECTRICAL BOX 1
25 1335693
K36470069 DRIVER BOARD 1
26 1347749
K33AE0016 RADIATOR 1
27
1341476 K33670019
SEPERA TOR SUPPORT PLATE 1
28 1204046
RZA-0-5315-016-XX-0 COVER ASSY 1
29 1352970
K36E10043 TERMINAL PANEL 1
30 1205797
RZA-4-2649-066-XX-0 PFC REACTOR 1
31
1336461 K33AB0050 NOISE DEFENING COVER(1) 1
32
1369591 K33AB0069 NOISE DEFENING COVER(2) 1
33
1303873 RZA-2-2476-196-XX-0 NOISE DEFENING COVER(3) 1
34 1341332
K37210142 COMPRESSOR ASSY 1
35
1353326 K31120104 BASE ASSY 1
36 1204014
852-2-2228-132-02-0 DRAINAGE HOSE 1
37 1304655
RZA-4-2239-090-XX-0
CAPACITOR
1
38 1203577
RZA-2-1111-014-XX-0
BACK GUARD
1
Page 62
99.. PPAARRTTSS LLIISST
T
60
39
1205548 RZA-2-2476-137-XX-0 NOISE DEFENING COVER(4)
1
40
1336465 K33AB0052 NOISE DEFENING COVER(5)
1
41
1301839 4-5259-390-04-0 TEMP SENSOR ASSY
1
42
1312582 K1C510001 TEMP SENSOR ASSY
1
43
1301842 4-5259-290-01-0 TEMP SENSOR ASSY
1
44
1301832 4-5259-390-02-0
TEMP SENSOR ASSY
1
45
1206641 RZA-4-2649-075-XX-0 ELECTROMAGNETIC COIL
1