Hirschmann SPIDER-SL-40-08T1 User Manual

Page 1
User Manual
SPIDER-SL-40-08T1
Installation SPIDER-SL-40-08T1
Release 01 08/2015
https://hirschmann-support.belden.eu.com
Technical support
Page 2
The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone.
© 2015 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is not permitted, either in whole or in part. An exception is the preparation of a backup copy of the software for your own use. For devices with embedded software, the end-user license agreement on the enclosed CD/DVD applies.
The performance features described here are binding only if they have been expressly agreed when the contract was made. This document was produced by Hirschmann Automation and Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right to change the contents of this document without prior notice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network components or the associated operating software. In addition, we refer to the conditions of use specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com).
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 1805 141538
SPIDER-SL-40-08T1 040 101-001-01-0815 - 27.8.15
Page 3
Contents
Safety instructions 4
About this Manual 9
Legend 9
1 Description 10
1.1 General device description 10
1.2 Device name and product code 11
1.3 Device view 12
1.4 Power supply 12
1.5 10/100/1000 Mbit/s twisted pair port 13
1.6 Pin assignments 13
1.7 Display elements 14
1.7.1 Device state 14
1.7.2 Port state 14
2 Installation 15
2.1 Checking the package contents 15
2.2 Mounting the device 16
2.3 Wiring the terminal block for the supply voltage and the grounding 17
2.4 Operating the device 18
2.5 Connecting data cables 18
3 Monitoring the ambient air temperature 19
4 Maintenance and service 20
5 Disassembly 21
6 Technical data 22
A Further Support 27
Installation SPIDER-SL-40-08T1
Release 01 08/2015
3
Page 4
Safety instructions
WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
General safety instructions
You operate this device with electricity. Improper usage of the device entails the risk of physical injury or significant property damage. The proper and safe operation of this device depends on proper handling during transportation, proper storage and installation, and careful operation and maintenance procedures. Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.The device is free of any service components. In case of a damaged
or malfunctioning the device, turn off the supply voltage and return the device to Hirschmann for inspection.
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 22.
Connect to the product only components suitable for the requirements
of the specific application case.
Installation SPIDER-SL-40-08T1
4
Release 01 08/2015
Page 5
Device casing
Only technicians authorized by the manufacturer are permitted to open the casing. Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not touch the connection terminals.
Keep the ventilation slits free to ensure good air circulation.
See “General technical data” on page 22.
Install the device in the vertical position.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the prerequisite for grounding and labeling circuits, devices, and systems in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable safety regulations.
Grounding the device
The device is grounded by means of a 3-pin terminal block. Use a wire diameter for the ground conductor that is no smaller than
the diameter of the supply voltage connection, however of at least
0.5 mm² (AWG20).
Shielding ground
The shielding ground of the connectable twisted pair cables is connected to the ground connection as a conductor. Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
Installation SPIDER-SL-40-08T1
Release 01 08/2015
5
Page 6
Requirements for connecting electrical wires
Before connecting the electrical wires, always verify that the requirements listed are complied with.
General requirements for connecting electrical wires The following requirements apply without restrictions:
The electrical wires are voltage-free.The cables used are permitted for the temperature range of the application case.The voltage connected complies with the requirements for a safety extra-low voltage
(SELV) as per IEC/EN 60950-1.
Relevant for North America:
Use 60/75 or 75 °C copper (Cu) wire only.
Requirements for connecting the supply voltage The following requirements apply without restrictions:
The supply voltage corresponds to the voltage specified on the type plate of the device.The power supply conforms to overvoltage category I or II.The power supply has an easily accessible disconnecting device (e.g., a switch or a plug).
This disconnecting device is clearly identified. So in the case of an emergency, it is clear which disconnecting device belongs to which power supply cable.
The power supply cable is suitable for the voltage, the current and the physical load.
Hirschmann recommends a wire diameter of 0.5 mm² (AWG20).
The cross-section of the ground conductor is the same size as or bigger than the cross-
section of the power supply cables.
The following requirements apply alternatively:
Alternative 1 The power supply complies with the requirements for a limited power source
(LPS) as per EN 60950-1.
Alternative 2 All of the following requirements are complied with:
The powersupply complies with the requirements for a safety extra-low
voltage (SELV) as per IEC/EN 60950-1.
A fuse suitable for DC voltage is located in the plus conductor of the power
supply. The minus conductor is on ground potential. Otherwise, a fuse is also located in the minus conductor. Regarding the properties of this fuse: See “General technical data” on
page 22.
Alternative 3 Relevant for North America:
The power supply complies with the requirements as per NEC Class 2
Supply voltage
The supply voltage is only connected with the ground connection via protective elements.
6
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 7
CE marking
The labeled devices comply with the regulations contained in the following European directive(s):
2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
2004/108/EC (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility.
In accordance with the above-named EU directive(s), the EU conformity declaration will be available to the relevant authorities at the following address:
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 1805 141538
The device can be used in the industrial sector.
Interference immunity: EN 61000-6-2Emitted interference: EN 55022
You find more information on technical standards here:
“Technical data” on page 22
The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values.
Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures.
Installation SPIDER-SL-40-08T1
Release 01 08/2015
7
Page 8
FCC note:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation. Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations. These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment. The device creates and uses high frequencies and can also radiate these frequencies. If it is not installed and used in accordance with this operating manual, it can cause radio transmission interference. The use of this device in a residential area can also cause interference, and in this case the user is obliged to cover the costs of removing the interference.
Recycling note
After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country.
8
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 9
About this Manual
The “Installation User Manual” document contains a device description, safety instructions, a display description and further information that you require to install the device.
Legend
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
Installation SPIDER-SL-40-08T1
Release 01 08/2015
9
Page 10
1 Description
1.1 General device description
The SPIDER-SL-40-08T1 devices are designed for the special requirements of industrial automation. They meet the relevant industry standards, provide very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility.
You have the ability to connect end devices or other segments to the ports of the device via twisted-pair cables.
The devices work without a fan.
The device is mounted by latching in place on a DIN rail.
10
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 11
1.2 Device name and product code
The device name corresponds to the product code. The product code is made up of characteristics with defined positions. The characteristic values stand for specific product properties.
Item Characteristic Character
istic value
1 ... 9 Product Spider SL Spider Standard Line
10 (hyphen) – 11 Data rate 4 10/100/1000 Mbit/s 12 Power over Ethernet (PoE) 0 without 13 (hyphen) – 14 ... 17 Twisted pair ports 08 8 × RJ45 socket
T1 Twisted pair 18 ... 19 Optical fiber port 1 99 without 20 ... 21 Optical fiber port 2 99 without 22 ... 23 Optical fiber port 3 99 without 24 Temperature range S Standard 0 °C ... +60 °C
25 ... 26 Certificates and declarations Z9 CE, FCC, EN 61131-2, EN 60950-1 27 ... 28 Customer-specific version HH Hirschmann Standard 29 ... 30 Configuration HH Hirschmann Standard
Description
Gigabit Ethernet switch
(+32 °F ... +140 °F)
Table 1: Device name and product code
Installation SPIDER-SL-40-08T1
Release 01 08/2015
11
Page 12
1.3 Device view
1
2
12
4
3
3
56
78
4
Overview of the device elements 1 3-pin, pluggable terminal block for power supply 2 LED display element for device status 3 8 × RJ45 socket for 10/100/1000 Mbit/s Twisted Pair connections 4 Rail lock gate for DIN rail mounting
1.4 Power supply
For the power supply of the device, a 3-pin terminal block is available.
For further information see “Wiring the terminal block for the supply voltage
and the grounding” on page 17.
12
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 13
1.5 10/100/1000 Mbit/s twisted pair port
This port is an RJ45 socket. The 10/100/1000 Mbit/s twisted pair port offers you the ability to connect network components according to the IEEE 802.3 10BASE-T/100BASE­TX/1000BASE-T standard. This port supports:
Autonegotiation Autopolarity Autocrossing1000 Mbit/s full duplex100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
1.6 Pin assignments
RJ45 Pin 10/100 Mbit/s 1000 Mbit/s
1 TX+ BI_DA+
1
2TX BI_DA−
2
3 RX+ BI_DB+
3 4
4— BI_DC+
5
5— BI_DC
6
6RX BI_DB−
7
7— BI_DD+
8
8— BI_DD
Installation SPIDER-SL-40-08T1
Release 01 08/2015
13
Page 14
1.7 Display elements
After the working voltage is set up, the software starts and initializes itself. Afterwards, the device performs a self-test. During this process, various LEDs light up.
1.7.1 Device state
This LED provides information on the status of the power supply.
Color Activity Meaning
Green Lights up Supply voltage is on
Device is ready for operation
None Supply voltage is too low
Device is not ready for operation
1.7.2 Port state
1
12
2 3
3
56
7
4
4 5
6 7
8
8
This LED shows port-related information.
Color Activity Meaning
Green Lights up Device detects a valid link
Flashing Device is transmitting and/or receiving data None Device detects an invalid or missing link
14
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 15
2Installation
The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation.
To configure a subdomain, follow these steps:
Checking the package contentsMounting the deviceWiring the terminal block for the supply voltage and the groundingOperating the deviceConnecting data cables
2.1 Checking the package contents
Check whether the package includes all items named in the section
“Scope of delivery” on page 25.
Check the individual parts for transport damage.
Installation SPIDER-SL-40-08T1
Release 01 08/2015
15
Page 16
2.2 Mounting the device
The device is for mounting on a 35 mm DIN rail in accordance with DIN EN
60715.
1
2
To mount the device onto a horizontally mounted 35 mm DIN rail according to DIN EN 60715, proceed as follows:
Slide the upper snap-in guide of the device into the DIN rail.Press the media module downwards onto the clip-in bar.Snap in the device.
16
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 17
2.3 Wiring the terminal block for the supply
voltage and the grounding
WARNING
ELECTRIC SHOCK
Connect only a supply voltage that corresponds to the type plate of your device. Never insert sharp objects (small screwdrivers, wires, etc.) into the connection terminals for the supply voltage, and do not touch the terminals.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
A 3-pin terminal block is used for the grounding and for connecting the supply voltage. The supply voltage is only connected with the ground connection via protective elements. The shielding ground of the connectable twisted pair cables is connected to the ground connection as a conductor.
0 V
24 V
Figure 1: 3-pin, pluggable terminal block for power supply and grounding
Type of the voltages that can be connected
DC voltage Rated voltage range DC
Table 2: Type and specification of the supply voltage and pin assignment on the
device
Specification of the supply voltage
12 V ... 24 V Voltage range DC incl. maximum tolerances
9.6 V ... 32 V
Connections
24 V Plus terminal of the supply
voltage
0 V Minus terminal of the supply
voltage Functional ground connection
Installation SPIDER-SL-40-08T1
Release 01 08/2015
17
Page 18
Proceed as follows: Ensure the required conditions for connecting the supply voltage.
See “Requirements for connecting electrical wires” on page 6.
Pull the terminal block off the device.Connect the ground connection.Connect the power supply cables.Plug the terminal block into the connection on the housing.
2.4 Operating the device
By connecting the supply voltage via the terminal block, you start the operation of the device.
2.5 Connecting data cables
Note the following general recommendations for data cable connections in environments with high electrical interference levels:
Keep the length of the data cables as short as possible. Use optical data cables for the data transmission between the buildings.When using copper cables, provide a sufficient separation between the
power supply cables and the data cables. Ideally, install the cables in separate cable channels.
Verify that power supply cables and data cables do not run parallel over
longer distances, and that ideally they are installed in separate cable channels. If reducing the inductive coupling is necessary, verify that the power supply cables and data cables cross at a 90° angle.
Use shielded cables (SF/UTP cables as per ISO/IEC 11801:2002).Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
Connect the data cables according to your requirements.
18
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 19
3 Monitoring the ambient air temperature
Operate the device below the specified maximum ambient air temperature exclusively.
See “General technical data” on page 22.
The ambient air temperature is the temperature of the air at a distance of 2 in (5 cm) from the device. It depends on the installation conditions of the device, e.g. the distance from other devices or other objects, and the output of neighboring devices.
Installation SPIDER-SL-40-08T1
Release 01 08/2015
19
Page 20
4 Maintenance and service
When designing this device, Hirschmann largely avoided using high-wear parts. The parts subject to wear and tear are dimensioned to last longer than the lifetime of the product when it is operated normally. Operate this device according to the specifications. Depending on the degree of pollution in the operating environment, check at regular intervals that the ventilation slots in the device are not obstructed.
CAUTION
RISK OF TRANSIENTS OR ELECTROSTATIC DISCHARGES
Do not open the housing.
Failure to follow these instructions can result in injury or equipment damage.
Note: You will find information about the complaints and returns procedures
on the Internet under
http://www.beldensolutions.com/en/Service/Repairs/index.phtml .
20
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 21
5Disassembly
1
2
Proceed as follows:
Disconnect the data cables.Disable the supply voltage.Remove the power connector from the device.Use a screwdriver to pull the rail lock gate downwards.Pull the device downwards from the DIN rail module.
Installation SPIDER-SL-40-08T1
Release 01 08/2015
21
Page 22
6 Technical data
General technical data
Dimensions W × H × D
Weight SPIDER-SL-40-08T1 170 g Power supply
Potential difference between incoming voltage and housing
Climatic conditions during operation
Climatic conditions during storage
Pollution degree 2 Protection classes Degree of protection IP 30
SPIDER-SL-40-08T1 See “Dimension drawings” on page 23.
1 voltage input3-pin terminal blockSafety extra-low voltage (SELV)
Rated voltage range DC 12 V ... 24 V
Class 2
Voltage range DC incl. maximum tolerances
Current consumption at 24 V DC 0.2 A Power loss buffer 10 ms at 20.4 V DC Back-up fuse 4 A, slow blow Peak inrush current 4 A Potential difference from
incoming voltage +24 V DC Potential difference from
incoming voltage, ground Ambient air temperature
Humidity 10 % ... 95 %
Air pressure minimum 795 hPa (+9842 ft; +2000 m) Ambient air temperature
Humidity 10 % ... 95 %
Air pressure minimum 700 hPa (+9842 ft; +3000 m)
a
a
9.6 V ... 32 V
+32 V DC
32 V DC
+32 °F ... +140 °F (0 °C ... +60 °C)
(non-condensing)
40 °F ... +158 °F (40 °C ... +70 °C)
(non-condensing)
a. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
22
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 23
Dimension drawings
14
102
38
736
Installation SPIDER-SL-40-08T1
Release 01 08/2015
23
Page 24
EMC and immunity
EMC interference emission
Radiated emission
FCC 47 CFR Part 15 Class A EN 55022 Class A
Conducted emission
FCC 47 CFR Part 15 Class A EN 55022 Class A
EMC interference immunity
Electrostatic discharge
EN 61000-4-2 IEEE C37.90.3
EN 61000-4-2 IEEE C37.90.3
Electromagnetic field
EN 61000-4-3 80 MHz ... 1000 MHz 10 V/m
Fast transients (burst)
EN 61000-4-4 IEEE C37.90.1
EN 61000-4-4 IEEE C37.90.1
Voltage surges - DC supply connection
EN 61000-4-5 line/ground 2 kV EN 61000-4-5 line/line 1 kV
Voltage surges - data line
EN 61000-4-5 line/ground 1 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V
Contact discharge ± 4 kV
Air discharge ± 8 kV
DC supply connection 2 kV
Data line 4 kV
Stability
IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with
IEC 60068-2-27, test Ea Shock 15 g at 11 ms
Network range
10/100/1000 Mbit/s twisted pair port
Length of a twisted pair segment max. 100 m (for cat5e cable)
24
3.5 mm amplitude
8.4 Hz ... 150 Hz with 1 g
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 25
Power consumption/power output at 24 V DC
Device name Max. power consumption Power output
SPIDER-SL-40-08T1 4.8 W 16.4 Btu (IT)/h
Scope of delivery
Number Article
1 × Device 1 × 3-pin, pluggable terminal block for power supply 1 × Safety Information
Order number
Device Order number
SPIDER-SL-40-08T1 942 132-004
Accessories
Note that products recommended as accessories may have different characteristics to those of the device, which may limit the application range of the overall system. For example, if you add an accessory with IP 20 to a device with IP 65, the IP of the overall system is reduced to 20.
Other accessories Order number
3-pin Low Voltage Interlock terminal block (50 pcs.) 943 845-005 Rail Power Supply RPS 30 943 662-003 Rail Power Supply RPS 80 EEC 943 662-080 Rail Power Supply RPS 120 EEC (CC) 943 662-121
Installation SPIDER-SL-40-08T1
Release 01 08/2015
25
Page 26
Underlying technical standards
Name
CSA C22.2 No. 142 Canadian National Standard(s) – Process Control Equipment –
Industrial Products
EN 55022 Information technology equipment – Radio disturbance
characteristics – Limits and methods of measurement
EN 60950-1 Information technology equipment – Safety – Part 1: General
requirements
EN 61000-6-2 Electromagnetic compatibility (EMC) – Part 6-2: Generic
standards – Immunity for industrial environments
EN 61131-2 Programmable controllers – Part 2: Equipment requirements and
tests FCC 47 CFR Part 15 Code of Federal Regulations UL/IEC 61010-1,
UL/IEC 61010-2-201
Safety for Control Equipment
Table 3: List of the technical standards
The device has an approval based on a specific standard only if the approval indicator appears on the device casing. The device generally fulfills the technical standards named in their current versions.
26
Installation SPIDER-SL-40-08T1
Release 01 08/2015
Page 27
A Further Support
Technical Questions
For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly.
You will find the addresses of our partners on the Internet at
http://www.hirschmann.com
Contact our support at
https://hirschmann-support.belden.eu.com
You can contact us
in the EMEA region at
Tel.: +49 (0)1805 14-1538E-mail: hac.support@belden.com
in the America region at
Tel.: +1 (717) 217-2270E-mail: inet-support.us@belden.com
in the Asia-Pacific region at
Tel.: +65 6854 9860E-mail: inet-ap@belden.com
Hirschmann Competence Center
The Hirschmann Competence Center is ahead of its competitors:
Consulting incorporates comprehensive technical advice, from system
evaluation through network planning to project planning.
Training offers you an introduction to the basics, product briefing and
user training with certification. The current technology and product training courses can be found at
http://www.hicomcenter.com
Support ranges from the first installation through the standby service
to maintenance concepts.
With the Hirschmann Competence Center, you have decided against making any compromises. Our client-customized package leaves you free to choose the service components you want to use. Internet:
http://www.hicomcenter.com
Installation SPIDER-SL-40-08T1
Release 01 08/2015
27
Page 28