The naming of copyrighted trademarks in this manual, even when not specially indicated, should
not be taken to mean that these names may be considered as free in the sense of the trademark
and tradename protection law and hence that they may be freely used by anyone.
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction,
translation, conversion into any electronic medium or machine scannable form is not permitted,
either in whole or in part. An exception is the preparation of a backup copy of the software for
your own use. For devices with embedded software, the end-user license agreement on the
enclosed CD/DVD applies.
The performance features described here are binding only if they have been expressly agreed
when the contract was made. This document was produced by Hirschmann Automation and
Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right
to change the contents of this document without prior notice. Hirschmann can give no guarantee
in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network
components or the associated operating software. In addition, we refer to the conditions of use
specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site
(www.hirschmann.com).
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Tel.: +49 1805 141538
SPIDER-SL-40-08T1 040 101-001-01-0815- 27.8.15
Contents
Safety instructions4
About this Manual9
Legend9
1Description10
1.1General device description10
1.2Device name and product code11
1.3Device view12
1.4Power supply12
1.510/100/1000 Mbit/s twisted pair port13
1.6Pin assignments13
1.7Display elements14
1.7.1Device state14
1.7.2Port state14
2Installation15
2.1Checking the package contents15
2.2Mounting the device16
2.3Wiring the terminal block for the supply voltage and the
grounding17
2.4Operating the device18
2.5Connecting data cables18
3Monitoring the ambient air temperature19
4Maintenance and service20
5Disassembly21
6Technical data22
AFurther Support27
Installation SPIDER-SL-40-08T1
Release 01 08/2015
3
Safety instructions
WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all
the data transmission devices individually.
Before you start any machine which is controlled via data transmission, be
sure to complete the configuration of all data transmission devices.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.
General safety instructions
You operate this device with electricity. Improper usage of the device
entails the risk of physical injury or significant property damage. The
proper and safe operation of this device depends on proper handling
during transportation, proper storage and installation, and careful
operation and maintenance procedures.
Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.
The device is free of any service components. In case of a damaged
or malfunctioning the device, turn off the supply voltage and return the
device to Hirschmann for inspection.
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 22.
Connect to the product only components suitable for the requirements
of the specific application case.
Installation SPIDER-SL-40-08T1
4
Release 01 08/2015
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not
touch the connection terminals.
Keep the ventilation slits free to ensure good air circulation.
See “General technical data” on page 22.
Install the device in the vertical position.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the
prerequisite for grounding and labeling circuits, devices, and systems
in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
Grounding the device
The device is grounded by means of a 3-pin terminal block.
Use a wire diameter for the ground conductor that is no smaller than
the diameter of the supply voltage connection, however of at least
0.5 mm² (AWG20).
Shielding ground
The shielding ground of the connectable twisted pair cables is connected
to the ground connection as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
Installation SPIDER-SL-40-08T1
Release 01 08/2015
5
Requirements for connecting electrical wires
Before connecting the electrical wires, always verify that the
requirements listed are complied with.
General requirements for connecting electrical wires
The following requirements apply without restrictions:
The electrical wires are voltage-free.
The cables used are permitted for the temperature range of the application case.
The voltage connected complies with the requirements for a safety extra-low voltage
(SELV) as per IEC/EN 60950-1.
Relevant for North America:
Use 60/75 or 75 °C copper (Cu) wire only.
Requirements for connecting the supply voltage
The following requirements apply without restrictions:
The supply voltage corresponds to the voltage specified on the type plate of the device.
The power supply conforms to overvoltage category I or II.
The power supply has an easily accessible disconnecting device (e.g., a switch or a plug).
This disconnecting device is clearly identified. So in the case of an emergency, it is clear
which disconnecting device belongs to which power supply cable.
The power supply cable is suitable for the voltage, the current and the physical load.
Hirschmann recommends a wire diameter of 0.5 mm² (AWG20).
The cross-section of the ground conductor is the same size as or bigger than the cross-
section of the power supply cables.
The following requirements apply alternatively:
Alternative 1The power supply complies with the requirements for a limited power source
(LPS) as per EN 60950-1.
Alternative 2All of the following requirements are complied with:
The powersupply complies with the requirements for a safety extra-low
voltage (SELV) as per IEC/EN 60950-1.
A fuse suitable for DC voltage is located in the plus conductor of the power
supply.
The minus conductor is on ground potential. Otherwise, a fuse is also
located in the minus conductor.
Regarding the properties of this fuse: See “General technical data” on
page 22.
Alternative 3Relevant for North America:
The power supply complies with the requirements as per NEC Class 2
Supply voltage
The supply voltage is only connected with the ground connection via
protective elements.
6
Installation SPIDER-SL-40-08T1
Release 01 08/2015
CE marking
The labeled devices comply with the regulations contained in the following
European directive(s):
2011/65/EU (RoHS)
Directive of the European Parliament and of the Council on the restriction
of the use of certain hazardous substances in electrical and electronic
equipment.
2004/108/EC (EMC)
Directive of the European Parliament and the council for standardizing the
regulations of member states with regard to electromagnetic
compatibility.
In accordance with the above-named EU directive(s), the EU conformity
declaration will be available to the relevant authorities at the following
address:
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Tel.: +49 1805 141538
The device can be used in the industrial sector.
Interference immunity: EN 61000-6-2
Emitted interference: EN 55022
You find more information on technical standards here:
“Technical data” on page 22
The assembly guidelines provided in these instructions must be strictly
adhered to in order to observe the EMC threshold values.
Warning! This is a class A device. This device can cause interference in
living areas, and in this case the operator may be required to take
appropriate measures.
Installation SPIDER-SL-40-08T1
Release 01 08/2015
7
FCC note:
This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference; (2) this device must accept any interference received,
including interference that may cause undesired operation.
Appropriate testing has established that this device fulfills the
requirements of a class A digital device in line with part 15 of the FCC
regulations.
These requirements are designed to provide sufficient protection against
interference when the device is being used in a business environment.
The device creates and uses high frequencies and can also radiate these
frequencies. If it is not installed and used in accordance with this
operating manual, it can cause radio transmission interference. The use
of this device in a residential area can also cause interference, and in this
case the user is obliged to cover the costs of removing the interference.
Recycling note
After usage, this device must be disposed of properly as electronic waste,
in accordance with the current disposal regulations of your county, state,
and country.
8
Installation SPIDER-SL-40-08T1
Release 01 08/2015
About this Manual
The “Installation User Manual” document contains a device description,
safety instructions, a display description and further information that you
require to install the device.
Legend
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
Installation SPIDER-SL-40-08T1
Release 01 08/2015
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.