Hirschmann SPIDER 3TX-TAP SPIDER 5TX, SPIDER 5TX EEC, SPIDER 8TX, SPIDER 8TX EEC, SPIDER 1TX/1FX User guide

...
Description and operating instructions Industrial ETHERNET Rail Switch
SPIDER xTX(/xFX)
The Rail Switches / media converters
– SPIDER 3TX-TAP – SPIDER 5TX – SPIDER 5TX EEC – SPIDER 8TX – SPIDER 8TX EEC – SPIDER 1TX/1FX (media converter) – SPIDER 1TX/1FX EEC (media converter) – SPIDER 1TX/1FX-SM (media converter) – SPIDER 1TX/1FX-SM EEC (media converter) – SPIDER 4TX/1FX – SPIDER 4TX/1FX EEC – SPIDER 4TX/1FX-ST EEC – SPIDER 4TX/1FX-SM EEC
in short SPIDER, are switches especially designed for use in industrial environments. It supports ETHERNET 10 MBit/s and Fast ETHERNET 100 MBit/s.
The devices support switched ETHERNET networks in accordance with IEEE standard
802.3 or 802.3u using copper and fiber optic technology. The devices are plugged onto the standard bar.
The SPIDER 3TX-TAP (SPIDER 5TX, SPIDER 5TX EEC, SPIDER 8TX, SPIDER 8TX EEC) devices have three (five, eight) 10/100 MBit/s twisted pair ports (RJ45 connectors). It is possible to connect up to three (five, eight) data terminal equipments or other network segments to the TP ports using twi­sted pair cabling.
The SPIDER 1TX/1FX... devices have one 10/100 MBit/s twisted pair port (RJ45 connectors) and one 100 MBit/s fiber optic port (100BASE-FX, Duplex SC connector). It is possible to connect one data terminal equipments or other network segments to the TP ports using twisted pair cabling. One further DTE or optical network component can be connected to the fiber port.
The SPIDER 4TX/1FX... devices have four 10/100 MBit/s twisted pair ports (RJ45 connectors) and one 100 MBit/s fiber optic port (100BASE-FX, Duplex SC connector or ST connector on SPIDER 4TX/1FX-ST EEC). It is possible to connect up to four data terminal equipments or other network segments to the TP ports using twisted pair cabling. One further DTE or optical network component can be connected to the fiber port.
The TP ports support autonegotiation, auto­polarity and autocrossing.
The fiber optic port of the SPIDER 1TX/1FX... and SPIDER 4TX/1FX... supports full duplex (FDX).
Hirschmann. Simply a good Connection.
P
x
SPIDER 3TX-TAP SPIDER 5TX
P
x
DA/STAT
SPIDER 4TX/1FX SPIDER 4TX/1FX EEC SPIDER 4TX/1FX-SM EEC
039669004030706000
SPIDER 5TX EEC
P
x
P
x
DA/STAT
SPIDER 4TX/1FX-ST EEC SPIDER
P
SPIDER 8TX SPIDER 8TX EEC
x
P
x
DA/STAT
SPIDER 1TX/1FX SPIDER 1TX/1FX EEC SPIDER 1TX/1FX-SM SPIDER 1TX/1FX-SM EEC
2
The performance features described here are binding only if they have been expressly guaranteed in the contract. We have checked that the contents of the technical publication agree with the hardware and software described. However, it is not possi­ble to rule out deviations completely, so we are unable to guarantee complete agree­ment. However, the details in the technical publication are checked regularly. Any cor­rections which prove necessary are contai­ned in subsequent editions. We are grateful for suggestions for improvement.
We reserve the right to make technical modifications.
Permission is not given for the circulation or reproduction of this document, its use or the passing on of its contents unless gran­ted expressly. Contravention renders the perpetrator liable for compensation for damages. All rights reserved, in particular in the case of patent grant or registration of a utility or design.
Copyright © Hirschmann Automation and Control GmbH 2006 All Rights Reserved
Note
We would point out that the content of these operating instructions is not part of, nor is it intended to amend an earlier or exi­sting agreement, permit or legal relation­ship. All obligations on Hirschmann arise from the respective purchasing agreement which also contains the full warranty condi­tions which have sole applicability. These contractual warranty conditions are neither extended nor restricted by comments in these operating instructions.
We would furthermore point out that for reasons of simplicity, these operating instructions cannot describe every conceivable problem associated with the use of this equipment. Should you require further information or should particular problems occur which are not treated in sufficient detail in the operating instruc­tions, you can request the necessary infor­mation from your local Hirschmann sales partner or directly from the Hirschmann office (address: refer to chapter entitled „Notes on CE identification“).
Safety Instructions
This manual contains instructions which must be observed to ensure your own per­sonal safety and to avoid damage to devices and machinery. The instructions are highlighted with a warning triangle and are shown as follows according to the degree of endan­germent:
z
Danger!
means that death, serious injury or considerable damage to property will result if the appropriate safety measures are not taken.
z
Warning!
means that death, serious injury or considerable damage to property can result if the appropriate safety measures are not taken.
z
Caution!
means that light injury or damage to property can result if the appropria­te safety measures are not taken.
Note: is an important piece of information about the product, how to use the product, or the relevant section of the documentati­on to which particular attention is to be drawn.
Certified usage
Please observe the following:
z
Warning
The device may only be employed for the purposes described in the catalog and technical description, and only in conjunction with external devices and components recommen­ded or approved by Hirschmann. The product can only be operated correctly and safely if it is transpor­ted, stored, installed and assembled properly and correctly. Furthermore, it must be operated and serviced carefully.
Safety Guidelines Power Supply
Switch the basic devices on only when the case is closed.
z
Warning!
The devices may only be connected to the supply voltage shown on the type plate.
The devices are designed for opera­tion with a safety extra-low voltage. Thus, they may only be connected to the supply voltage connections with PELV circuits or alternatively SELV circuits with the voltage restrictions in accordance with IEC/EN 60950-1.
For the case where the module is opera­ted with external power supply: Use only a safety extra-low voltage in accordance with IEC/EN 60950-1 to power the system.
First of all you connect the ground connection, before you establish the further connections. When you remove connec­tions, you disconnect the ground connec­tion last.
Relevant for North America: The subject unit is to be suppplied by a Class 2 power source complying with the requirements of the National Electrical Code, table 11(b).
Relevant for North America: Power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods [Article 501-4(b) of the National Electrical Code, NFPA 70] and in accordance with the authority having juris­diction.
Peripheral equipment must be suitable for the location it is used in.
Use 60/75°C or 75°C copper(CU)wire only.
Safety Guidelines Shielding Ground
Beware of possible short circuits when connecting a cable section with conductive shielding braiding.
Safety Guidelines Housing
z
Warning!
Only technicians authorized by Hirschmann are permitted to open the housing.
Note: The SPIDER is grounded via a pin of the 3pin terminal block.
Make sure that the electrical installation meets local or nationally applicable safety regulations.
z
Warning!
The ventilation slits must not be covered so as to ensure free air cir­culation.
The distance to the ventilation slots on the top and the bottom of the housing has to be a minimum of 10 cm. The side distance of the SPIDER 4TX/1FX... and SPIDER 8TX... devi­ces to neighbour devices has to be a minimum of 2 cm if the ambient temperature is higher than 50°C.
Never insert pointed objects (thin screwdrivers, wires, etc.) into the inside of the subrack! Failure to observe this point may result in inju­ries caused by electric shocks.
Note: If installed in a living area or office environment, the device must be operated exclusively in switch cabinets with fire pro­tection characteristics according to EN 60950-1.
Note: The housing has to be mounted in upright position.
Safety Guidelines Environment
z
Warning!
The device may only be operated in the listed ambient temperature range at the listed relative air humi­dity (non-condensing).
The installation location is to be selec­ted so as to ensure compliance with the cli­matic limits listed in the Technical Data.
To be used in an up to Pollution Degree 2 environment only (IEC 60664-1).
3
Based specifications and standards:
The devices fulfil the following specifications and standards: – EN 61000-6-2:2001 Generic standards –
Immunity for industrial environments
– EN 55022:1998 + A1:2000 + A2:2003 –
Information technology equipment – Radio disturbance characteristics
– EN 60950-1:2001 – Safety of Information
Technology Equipment (ITE)
– EN 61131-2:2003 – Programmable Control-
lers
– FCC 47 CFR Part 15:2004–
Code of Federal Regulations
– cUL 508:1998 – Underwriters Labratories
Inc. Safety for Industrial Control
Equipment. Certified devices are marked with a certification identifier.
7
Notes on CE identification
The devices comply with the regula­tions of the following European directive:
89/336/EEC Council Directive on the harmoniza­tion of the legal regulations of mem­ber states on electromagnetic com­patibility (amended by Directives 91/263/EEC, 92/31/EEC and 93/68/EEC).
SPIDER 5TX EEC: 72/245/EEC, 2005/83/EG Radio interference (electromagnetic compatibility) in vehicles Certified devices are marked with a e1 certification identifier.
The EU declaration of conformity is kept available for the responsible authorities in accordance with the above-mentioned EU directives at:
Hirschmann Automation and Control GmbH Stuttgarter Straße 45-51 D-72654 Neckartenzlingen Telefon ++49-(0)1805-14-1538
The product can be used in the resi­dential sphere (residential sphere, business and trade sphere and small companies) and in the industrial sphere. – Interference immunity:
EN 61000-6-2:2001
– Radio interference level:
EN 55022:1998 + A1:2000 + A2:2003, Class A
z
Warning!
This is a Class A device. This equip­ment may cause radio interference if
Staff qualification requirements
Note: Qualified personnel, as understood
in this manual and in the warning signs, are persons who are familiar with the setup, assembly, startup, and operation of this product and are appropriately qualified for their job. This includes, for example, those persons who have been:
– trained or directed or authorized to
switch on and off, to ground and to label power circuits and devices or systems in accordance with current safety enginee­ring standards
– trained or directed in the care and use of
appropriate safety equipment in accor­dance with the current standards of safety engineering
– trained in providing first aid.
General Safety Instructions
This device is electrically operated. Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions!
z
Warning!
Failure to observe the information given in the warnings could result in serious injury and/or major damage.
Only personnel that have received appropriate training should operate this device or work in its immediate vicinity. The personnel must be fully familiar with all of the warnings and maintenance measures in these operating instructions.
Correct transport, storage, and assembly as well as careful operati­on and maintenance are essential in ensuring safe and reliable operation of this device.
Use only undamaged parts!
These products are only to be used in the manner indicated in this version of the ”Description and Operating Instructions”.
Particular attention is to be paid to all warnings and items of information relating to safety.
z
Warning!
Any work that may have to be per­formed on the electrical installation should be performed by fully quali­fied technicians only.
z
Warning!
(SPIDER 1TX/1FX... SPIDER 4TX/1FX...) LED- or LASER components accor­ding to IEC 60825-1 (2001): CLASS 1 LASER PRODUCT. LIGHT EMITTING DIODE - CLASS 1 LED PRODUCT.
used in a residential area; in this case it is the operator´s responsibili­ty to take appropriate measures.
The precondition for compliance with EMC limit values is strict adhe­rence to the construction guidelines specified in this description and operating instructions.
FCC Note:
This equipment has been tested and found to comply with the limits for a Class A digi­tal device, persuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inter­ference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre­quency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inter­ference at his own expense.
,
Recycling Note:
After its use, this product has to be processed as electronic scrap and disposed of according to the prevai­ling waste disposal regulations of your community / district / country / state.