Installation RSPM
Release 15 04/2018
Technical support
https://hirschmann-support.belden.eu.com
Installation Industrial Ethernet Rail Switch Power Media module
RSPM
Page 2
The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone.
© 2018 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is not permitted, either in whole or in part. An exception is the preparation of a backup copy of the software for your own use.
The performance features described here are binding only if they have been expressly agreed when the contract was made. This document was produced by Hirschmann Automation and Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right to change the contents of this document without prior notice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network components or the associated operating software. In addition, we refer to the conditions of use specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com).
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany
RSPM 26.04.2018
Page 3
Installation RSPM
Release 15 04/2018
3
Contents
Safety instructions 5
About this manual 14
Key 15
1 Description 16
1.1 General description 16
1.2 Device name and product code 17
1.3 Media module variants 19
1.3.1 Port configuration 19
1.3.2 Media module slots on the RSPE device 20
1.4 Ethernet ports 21
1.4.1 100 Mbit/s F/O port 21
1.4.2 10/100 Mbit/s twisted pair port 21
1.4.3 Support of PoE(+) 22
1.5 Display elements 23
1.5.1 Media module status 23
1.5.2 Port status 24
2 Installation 25
2.1 Checking the package contents 25
2.2 Mounting a media module 25
2.3 Installing an SFP transceiver (optional) 26
2.4 Connecting data cables 26
3 Maintenance and service 27
4 Disassembly 28
4.1 Removing an SFP transceiver (optional) 28
4.2 Removing a media module 28
5 Technical data 29
6 Scope of delivery, order numbers and
accessories 35
Page 4
4
Installation RSPM
Release 15 04/2018
6.1 Scope of delivery 35
6.2 Accessories 35
7 Underlying technical standards 37
A Further support 38
Page 5
Installation RSPM
Release 15 04/2018
5
Safety instructions
General safety instructions
You operate this device with electricity. Improper usage of the device entails the risk of physical injury or significant property damage. The proper and safe operation of this device depends on proper handling during transportation, proper storage and installation, and careful operation and maintenance procedures. Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.The device is free of any service components. In case of a damaged
or malfunctioning the device, turn off the supply voltage and return the device to Hirschmann for inspection.
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 29.
Connect to the product only components suitable for the requirements
of the specific application case.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the prerequisite for grounding and labeling circuits, devices, and systems in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable safety regulations.
Page 6
6
Installation RSPM
Release 15 04/2018
Shielding ground
The overall shield of a connected shielded twisted pair cable is connected to the grounding connector on the front panel as a conductor. Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
ESD Guidelines
The modules are equipped with electrostatically sensitive components. These can be destroyed, or their life cycles reduced, by the effects of an electrical field or by a charge equalization if the connections are touched. You will find information about electrostatically endangered assemblies in DIN EN 61340-5-1 (2007-08) and DIN EN 61340-5-2 (2007-08).
Page 7
Installation RSPM
Release 15 04/2018
7
ATEX directive 2014/34/EU – specific regulations for safe
operation
The following applies to RSPM devices if you operate them in areas with explosive gases according to ATEX directive 2014/34/EU:
List of standards:
EN 60079-0:2012, A11:2013 EN 60079-15:2010 Certificate No.: DEKRA 15ATEX0016X
Use only device variants featuring supply voltage with characteristic
value CC.
Make sure that the device has the following label:
II 3G Ex nA IIC T4 Gc DEKRA 15ATEX0016X
for RSPM types
Environmental class and temperature code for RSPM types:
T4: 0 °C Ta +60 °C for “S“ types or T4: 40 °C Ta +70 °C for “T“ or “E“ types
Ambient rating and temperature code for RSPM types:
T4: 0 °C Ta +60 °C for “S” types or T4: 40 °C Ta +70 °C for “T” or “E” types
The modules shall be installed in a suitable enclosure in accordance
with IEC 60079-15 providing a degree of protection of at least IP54 according to IEC 60529, taking into account the environmental conditions under which the equipment will be used.
When the temperature under rated conditions exceeds 158 °F (70 °C)
at the cable or conduit entry point, or 176 °F (80 °C) at the branching point of the conductors, the temperature specification of the selected cable and cable entries shall be in compliance with the actual measured temperature values.
Provisions shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 119 V.
Connectors shall be connected or disconnected exclusively in dead-
voltage state.
The USB port must not be connected.
Page 8
8
Installation RSPM
Release 15 04/2018
Relevant for use in explosion hazard areas (Hazardous
Locations, Class I, Division 2)
The relay connections are to be installed and used within their Entity Parameters as per Control Drawing 000182303DNR.
Avertissement - Risque d'explosion - Ne pas débrancher tant que le circuit est sous tension à moins que l'emplacement soit connu pour ne contenir aucune concentration de gaz inflammable.
Avertissement - Risque d'explosion - La substitution de tout composant peut rendre ce matériel incompatible pour une utilisation en classe I, division 2.
Page 9
Installation RSPM
Release 15 04/2018
9
Control Drawing for RSPE devices according to Class , Division 2 Hazardous Locations Rev.: 1 Document No.: 000182303DNR Page 1/2
For Use in Hazardous Locations Class I Division 2 Groups A, B, C, D:
Only allowed for RSPE/RSPM model No´s. which are individually labeled “FOR USE IN HAZARDOUS LOCATIONS”.
This equipment is suitable for use in Class I, Division 2,
Groups A, B, C, and D OR non-hazardous locations only.
Nonincendive  eld wiring circuits must be wired in accordance with the National Electrical Code (NEC), NFPA 70, article 501.
WARNING – EXPLOSION HAZARD Substitution of any components may impair suitability for hazardous locations or explosive atmospheres.
WARNING – EXPLOSION HAZARD Do not disconnect equipment unless power has been switched off or the area is known to be known to be non-hazardous.
Page 10
10
Installation RSPM
Release 15 04/2018
Control Drawing for RSPE devices according to Class , Division 2 Hazardous Locations Rev.: 1 Document No.: 000182303DNR Page 2/2
Ordinary Location,
Non-Hazardous Area,
Non-Explosive Atmosphere
Explosive Atmosphere Class , Division 2 Groups A, B, C, D Hazardous Location
RSPE - Industrial Ethernet
Rail Switch Power Enhanced
Relay
USB
P1
P2
The earth conductor must
be at least of the same wire size (mm² or
AWG)
as the supply conductors.
Temperature Code: T4 Ambient Temperature rating: Ta: 0 °C to +60 °C for “S” temperature types Ta: í40 °C to +70 °C for “T” or “E” temperature types
(Refer to the temperature code of the type designation on the device.)
Power Supply connectors
*) Notes:
The nonincendive  eld wiring circuit concept allows interconnection
of nonincendive  eld wiring apparatus and associated nonincendive  eld wiring apparatus using any of the wiring methods permitted for unclassi ed locations when certain parametric conditions are met.
Capacity: Ca Ci + C
Cable
; Inductivity: La Li + L
Cable
WARNING!
The USB is for temporary connection only, for maintenance
use. Do not use, connect or disconnect unless the area is known to be non-hazardous. Connection or disconnection in an explosive atmosphere could result in an explosion.
The maximum cable length has to be determined as follows:
(a) max. Cable Length < (La í Li) / Cable
L
(”CableL” denotes the inductance per unit length of used cable) and
(b) max. Cable Length < (Ca í Ci) / Cable
C
(“CableC” denotes the capacitance per unit length of used cable)
The lower value of (a) and (b) is to apply.
Relay contacts: Equipment with nonincendive  eld wiring parameters. Polarity is not relevant.
The relay terminals are dependent upon the following
Entity parameters:
U
i
I
i
C
i
L
i
30 V 90 mA 2 nF 1 H
Page 11
Installation RSPM
Release 15 04/2018
11
IECEx – Certification Scheme for Explosive Atmospheres
For RSPM devices labeled with an IECEx certificate number, the following applies:
List of standards: IEC 60079-0:2011+Cor.2012+Cor.2013 IEC 60079-15:2010
The device is suitable for use in an area with a degree of soiling of 2
as per IEC 60664-1.
Make sure that the device has the following label:
Ex nA IIC T4 Gc IECEx DEK 15.0013X
for RSPM types
Environmental class and temperature code for RSPM types:
T4: 0 °C Ta +60 °C for “S“ types or T4: 40 °C Ta +70 °C for “T“ or “E“ types
The modules shall be installed in a suitable enclosure in accordance
with IEC 60079-15 providing a degree of protection of at least IP54 according to IEC 60529, taking into account the environmental conditions under which the equipment will be used.
When the temperature under rated conditions exceeds 70 °C at the
cable or conduit entry point, or 80 °C at the branching point of the conductors, the temperature specification of the selected cable and cable entries shall be in compliance with the actual measured temperature values.
Provisions shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 119 V.
Connectors shall be connected or disconnected exclusively in dead-
voltage state.
The USB port shall remain disconnected.
Page 12
12
Installation RSPM
Release 15 04/2018
CE marking
The statements in this chapter refer only to media modules which are correctly mounted in a RSPE basic device (see on page 25 “Mounting a
media module”).
The labeled devices comply with the regulations contained in the following European directive(s):
2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
2014/30/EU (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility.
In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address:
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen www.hirschmann.com
The device can be used in the industrial sector.
Interference immunity: EN 61000-6-2Emitted interference: EN 55032Reliability: EN 60950-1
You find more information on technical standards here: “Technical data” on page 29
Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures.
LED or laser components
LED or LASER components according to IEC 60825-1 (2014): CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT
Page 13
Installation RSPM
Release 15 04/2018
13
FCC note:
The statements in this chapter refer only to media modules which are correctly mounted in aRSPE basic device (see on page 25 “Mounting a
media module”).
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation. Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations. These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment. The device creates and uses high frequencies and can also radiate these frequencies. If it is not installed and used in accordance with this operating manual, it can cause radio transmission interference. The use of this device in a residential area can also cause interference, and in this case the user is obliged to cover the costs of removing the interference.
Recycling note
After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country.
Page 14
14
Installation RSPM
Release 15 04/2018
About this manual
The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device.
Documentation mentioned in the "Installation" user manual that is not supplied with your device in print can be found as PDF download on the Internet at the Hirschmann product pages (www.hirschmann.com).
Page 15
Installation RSPM
Release 15 04/2018
15
Key
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
Page 16
16
Installation RSPM
Release 15 04/2018
1 Description
1.1 General description
The RSPM media modules are designed for exclusive use in a RSPE basic device. By using media modules, you obtain up to 16 additional Fast Ethernet ports on a RSPE basic device. You will find more information on the media modules in the “User Manual for Installation of RSPE”. You can choose from between a wide range of variants. You have the option to set up your device individually based on different criteria:
Types of connectorsSupport of PoE(+)Temperature rangeCertifications
The RSPM media modules are designed for the special requirements of industrial automation. They meet the relevant technical standards, provide very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility. You have the option of choosing various media to connect to the end devices and other network components:
Multimode optical fiberSinglemode optical fiberTwisted pair cable
Page 17
Installation RSPM
Release 15 04/2018
17
1.2 Device name and product code
The device name corresponds to the product code. The product code is made up of characteristics with defined positions. The characteristic values stand for specific product properties. You have numerous options of combining the device characteristics. You can determine the possible combinations using the Configurator which is available in the Belden E-Catalog (www.e-catalog.beldensolutions.com) on the web page of the device.
Item Characteristic Character
istic value
Description
1 ... 4 Product RSPM Rail Switch Power Media Module 5 Data rate 2 10/100 Mbit/s 6 Hardware type 0 Standard
2 Standard with PoE(+) 7 (hyphen) – 8 ... 10 Port configuration
Part A
4Z6 4 × SFP slot for 100 Mbit/s F/O connections
4T1 4 × RJ45 socket for 10/100 Mbit/s twisted pair
connections
11 ... 13 Port configuration
Part B
4Z6 4 × SFP slot for 100 Mbit/s F/O connections
4T1 4 × RJ45 socket for 10/100 Mbit/s twisted pair
connections
14 Temperature range S Standard +32 °F ... +140 °F (0 °C ...
+60 °C)
T Extended 40 °F ... +158 °F
(40 °C ... +70 °C)
E Extended with
Conformal Coating
40 °F ... +158 °F (40 °C ... +70 °C)
15 ... 16 Certificates and
declarations
You will find detailed information on the certificates and
declarations applying to your device in a separate overview.
See table 2 on page 18.
17 ... 18 Customer-specific
version
HH Hirschmann Standard
19 Hardware
configuration
S Standard
20 Software configuration 9 without configuration 21 ... 25 Software version 99.9. without software 26 ... 27 Maintenance 99 without software
Table 1: Device name and product code
Page 18
18
Installation RSPM
Release
15
04/2018
Application case Certificates and
declarations
Characteristic value
a
a. X = Approval or self-declaration present
Z9 X9 W9 WX WU WD WC WB WA U9 UY UX UW T9 TY V9 VP VU P9
Standard applications ATEX Zone 2 XXXXXXX X
IECEx XXXX CE XXXXXXXXXXXXXXXXXXX EN 60950-1 X X XXXXXXXXXXXXXXXX X EN 61131-2 X X XXXXXXXXXXXXXXXXX FCC XXXXXXXXXXXXXXXXXXX ISA-12.12.01 ClassI, Div.2 X XXXX X UL 61010-1, UL 61010-2-210 X XXXX XXX X XXX UL 60950-1
Substation applications IEC 61850-3 XXX
IEEE 1613 XXX Navy applications GL XX X XXXX X Railway applications
(trackside)
EN 50121-4 XX
Table 2: Assignment: application cases, certificates and declarations, characteristic values
Page 19
Installation RSPM
Release 15 04/2018
19
1.3 Media module variants
The media modules have different interface types. The different interfaces of the media modules provide you with the following functions:
Specific functions of the TP/TX interface
Auto Polarity ExchangeAutocrossing (device may be connected with a crossed-over or an un-
crossed cable)
Autonegotiation (selecting the operating mode: speed/duplex)Link Control
Specific functions of the F/O interface
Link Down monitoring
1.3.1 Port configuration
The 8 ports of the media modules are arranged in the port configuration parts A and B, each part comprising 4 ports. The media module variants provide one of the following interface types for each port configuration part:
SFP slot for 100 Mbit/s F/O connectionsRJ45 socket for 10/100 Mbit/s twisted pair connections
See “Device name and product code” on page 17.
A Port configuration Part A B Port configuration Part B
A
B
RSPM20-4Z64Z6...
RSPM20-4T14Z6...
RSPM20-4T14T1... RSPM22-4T14Z6... RSPM22-4T14T1...
Page 20
20
Installation RSPM
Release 15 04/2018
1.3.2 Media module slots on the RSPE device
1 Slot 1 for media module RSPM
All media modules are pluggable except RSPM20-4Z64Z6... (8 F/O ports)
2 Slot 2 for media module RSPM
All media modules are pluggable.
12
Page 21
Installation RSPM
Release 15 04/2018
21
1.4 Ethernet ports
You have the option to connect terminal devices or other segments to the ports of the media modules via twisted-pair cables or F/O cables. Connect the ports of the media modules plugged into the basic device as required in order to set up your industrial Ethernet or expand your existing network.
1.4.1 100 Mbit/s F/O port
This port is an SFP slot.
See “Accessories” on page 35.
The 100 Mbit/s F/O port allows you to connect network components according to the IEEE 802.3 100BASE-FX standard. This port supports:
100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode
Default setting: Full duplex
Note: Insert the RSPM20-4Z64Z6... media module in the media module slot 2 only.
See “Media module slots on the RSPE device” on page 20.
1.4.2 10/100 Mbit/s twisted pair port
This port is an RJ45 socket. The 10/100 Mbit/s twisted pair port allows you to connect network components according to the IEEE 802.3 10BASE-T/100BASE-TX standard. This port supports:
Autonegotiation Autopolarity Autocrossing (if autonegotiation is activated)100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
Delivery state: Autonegotiation activated The port casing is electrically connected to the front panel.
Pin Function
1 RD+ Receive path 2RD Receive path 3 TD+ Transmission path 6TD Transmission path 4,5,7,8
Table 3: Pin assignment 10/100 Mbit/s twisted pair port, RJ45 socket, MDI-X mode
1 2 3 4 5 6 7 8
Page 22
22
Installation RSPM
Release 15 04/2018
1.4.3 Support of PoE(+)
See “Device name and product code” on page 17.
The 10/100 Mbit/s twisted pair port allows you to connect network components as a PoE voltage sink according to the standard IEEE 802.3 10BASE-T/100BASE-TX and IEEE 802.3af/at. With the presence of the PoE power supply, a separate power supply for the connected device is unnecessary. The PoE power is supplied via the wire pairs transmitting the signal (phantom voltage). The individual ports (joint PoE voltage) are not electrically insulated from each other.
Maximum power available to PoE end devices in total: 124 W Maximum power available to a media module: 62 W
Note: Connect only PoE-supplier devices whose data connections are located in the interior of the building and are specified as SELV circuits.
The PoE support complies with the following technical standards:
In accordance with IEEE 802.3af and IEEE 802.3at:
Endpoint PSEAlternative A.
Technical standard
Description
IEEE 802.3af Brief description PoE
Classes max. Powered Device (PD) class 0 (15,4 W)
IEEE 802.3at Brief description PoE+
Classes max. Powered Device (PD) class 4 (30 W)
Table 4: PoE support: technical standards
Page 23
Installation RSPM
Release 15 04/2018
23
1.5 Display elements
1.5.1 Media module status
Device variant RSPM20
1 LED is located on the upper part of the media module. This LED provides information on the supply voltage status of the media module.
Device variant RSPM22
2 LEDs are located on the upper part of the media module. These LEDs combined provide information on the supply voltage status and the PoE status of the media module.
LED Display Color Activity Meaning
Power Supply voltage none Media module is inoperative
green lights up Supply voltage is on
LED Display Color Activity Meaning
Power Supply voltage none Media module is inoperative
green lights up Voltage supply to the media module is on
Voltage supply to the PoE port is on
yellow lights up PoE voltage is missing or is too low
Power
Power
P
Page 24
24
Installation RSPM
Release 15 04/2018
1.5.2 Port status
These LEDs provide port-related information. The LEDs are directly located on the ports.
LED Display Color Activity Meaning
L/D Link status none Device detects an invalid or missing
link
green lights up Device detects a valid link
flashes 1 time a period Port is switched to stand-by flashes 3 times a period Port is switched off
yellow lights up Device detects a non-supported SFP
transceiver or a non-supported data rate
flashing Device is transmitting and/or receiving
data
flashes 1 time a period Device detects at least one
unauthorized MAC address (Port Security Violation)
PoE PoE status none RSPM 20:
LED is without any function RSPM 22:
No powered device connected
green lights up Power device is supplied with PoE
voltage
yellow flashes 1 time a period Output budget has been exceeded
Device has detected a connected powered device
flashes 3 times a period PoE administrator status deactivated
FX
TX
PoE
L/D
L/D
Page 25
Installation RSPM
Release 15 04/2018
25
2Installation
The devices have been developed for practical application in a harsh industrial environment. Hirschmann supplies the media modules ready for operation.
To configure a subdomain, follow these steps:
Checking the package contentsMounting a media moduleInstalling an SFP transceiver (optional)Connecting data cables
2.1 Checking the package contents
Proceed as follows: Check whether the package includes all items named in the section
“Scope of delivery” on page 35.
Check the individual parts for transport damage.
2.2 Mounting a media module
The media modules provide restricted hot-swap-capability. You have the option of mounting the media modules while the device is operating. To start the operation, it is necessary to restart the device.
Proceed as follows: Remove the cover panel (if mounted) from the media module slot on the
device.
Insert the media module into the slot on the device.Fasten the media module to the device by tightening the 2 screws.Restart the device.
Page 26
26
Installation RSPM
Release 15 04/2018
2.3 Installing an SFP transceiver (optional)
Prerequisites: Exclusively use Hirschmann SFP transceivers.
See “Accessories” on page 35.
Figure 1: Installing SFP transceivers: Installation sequence
Proceed as follows:
Take the SFP transceiver out of the transport packaging (1).Remove the protection cap from the SFP transceiver (2).Push the SFP transceiver with the lock closed into the slot until it latches
in (3).
2.4 Connecting data cables
Note the following general recommendations for data cable connections in environments with high electrical interference levels:
Keep the length of the data cables as short as possible. Use optical data cables for the data transmission between the buildings.When using copper cables, provide a sufficient separation between the
power supply cables and the data cables. Ideally, install the cables in separate cable channels.
Verify that power supply cables and data cables do not run parallel over
longer distances. If reducing the inductive coupling is necessary, verify that the power supply cables and data cables cross at a 90° angle.
Use SF/UTP cables as per ISO/IEC 11801:2002.
Connect the data cables according to your requirements. Further information:
See “Device name and product code” on page 17.
123
Page 27
Installation RSPM
Release 15 04/2018
27
3 Maintenance and service
When designing this device, Hirschmann largely avoided using high-wear
parts. The parts subject to wear and tear are dimensioned to last longer than the lifetime of the product when it is operated normally. Operate this device according to the specifications.
Hirschmann is continually working on improving and developing their
software. Check regularly whether there is an updated version of the software that provides you with additional benefits. You find information and software downloads on the Hirschmann product pages on the Internet (http://www.hirschmann.com).
Note: You find information on settling complaints on the Internet at http://
www.beldensolutions.com/en/Service/Repairs/index.phtml.
Page 28
28
Installation RSPM
Release 15 04/2018
4 Disassembly
4.1 Removing an SFP transceiver (optional)
Figure 2: Removing an SFP transceiver: Removal sequence
Proceed as follows:
Open the locking mechanism of the SFP transceiver (1).Pull the SFP transceiver out of the slot via the open locking
mechanism (2).
Close the SFP transceiver with the protection cap (3).
4.2 Removing a media module
You have the option to remove the media modules while the device is operating. Proceed as follows:
Loosen the 2 screws on the media module.Pull the media module out of the slot.Seal the media module slot on the device with a cover panel.
See “Accessories” on page 35.
312
Page 29
Installation RSPM
Release 15 04/2018
29
5 Technical data
General technical data
Dimensions RSPM See “Dimension drawings” on page 30. Weight RSPM20-4Z64Z6... 10.23 oz (290 g)
RSPM20-4T14T1... RSPM22-4T14T1...
4.59 oz (130 g)
RSPM20-4T14Z6... RSPM22-4T14Z6...
7.76 oz (220 g)
Climatic conditions during operation
Ambient air temperature
a
.
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
Devices with operating temperature characteristic value S (standard): +32 °F ... +140 °F (0 °C ... +60 °C)
b
b. Hirschmann recommends to use SFP transceivers with “EEC” extension.
Devices with the operating temperature characteristic value E and T (Extended)
c
:
40 °F ... +158 °F (40 °C ... +70 °C)
d
40 °F ... +185 °F (40 °C ... +85 °C) for 16 hours (tested in accordance with IEC 60068­2-2)
d
c. Note the specifications for the basic device in the “User Manual Installation RSPE”. d. Use SFP transceivers with the “EEC” extension only, otherwise the standard temperature
range applies.
Maximum inner temperature of device (guideline)
Devices with operating temperature characteristic value S (standard): 190 °F (88 °C)
Devices with operating temperature characteristic value E and T (extended): 208 °F (98 °C)
Humidity 5 % ... 95 %
(non-condensing)
Air pressure min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (−1312 ft; −400 m)
Climatic conditions during storage
Ambient air temperature
a
40 °F ... +185 °F (40 °C ... +85 °C)
Humidity 5 % ... 95 %
(non-condensing)
Air pressure min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (−1312 ft; −400 m) Pollution degree 2 Protection
classes
Laser protection Class 1 in compliance with IEC 60825-1 Degree of protection of the
RSPE device
IP20
Page 30
30
Installation RSPM
Release 15 04/2018
Dimension drawings
Figure 3: Dimensions of a media module
mm inch
6,64
0.26
101,05
3.98
35
1.38
144,56
5.69 128,56
5.06
Page 31
Installation RSPM
Release
15
04/2018
31
EMC and immunity
You will find detailed information on the certificates and declarations applying to your device in a separate overview.
See table 2 on page 18.
EMC interference emission
Standard applications
Navy applications Railway
applications (trackside)
Substation applications
Radiated emission
EN 55032 Class A Class A Class A Class A GL Guidelines EMC 1 — FCC 47 CFR Part 15 Class A Class A Class A Class A EN 61000-6-4 Fulfilled Fulfilled Fulfilled Fulfilled
Conducted emission
EN 55032 DC supply connection Class A Class A Class A Class A GL Guidelines DC supply connection EMC 1 — FCC 47 CFR Part 15 DC supply connection Class A Class A Class A Class A EN 61000-6-4 DC supply connection Fulfilled Fulfilled Fulfilled Fulfilled EN 55032 Telecommunication connections Class A Class A Class A Class A EN 61000-6-4 Telecommunication connections Fulfilled Fulfilled Fulfilled Fulfilled
EMC interference immunity
Standard applications
Navy applications Railway
applications (trackside)
Substation applications
Electrostatic discharge
EN 61000-4-2 IEEE C37.90.3
Contact discharge ±4kV ±6kV ±6kV ±8kV
EN 61000-4-2 IEEE C37.90.3
Air discharge ±8kV ±8kV ±8kV ±15kV
Electromagnetic field
EN 61000-4-3 80 MHz ... 3000 MHz 10 V/m 10 V/m 20 V/m 10 V/m
Page 32
32
Installation RSPM
Release
15
04/2018
IEEE 1613 80 MHz ... 1000 MHz 35 V/m
Fast transients (burst)
EN 61000-4-4 IEEE C37.90.1
DC supply connection ±2 kV ±2 kV ±2 kV ±4 kV
EN 61000-4-4 IEEE C37.90.1
Data line ±4 kV ±4 kV ±2 kV ±4 kV
Voltage surges - DC supply connection
EN 61000-4-5 line/ground ±2 kV ±2 kV ±2 kV ±2 kV IEEE 1613 line/ground ±5 kV EN 61000-4-5 line/line ±1 kV ±1 kV ±1 kV ±1 kV
Voltage surges - data line
EN 61000-4-5 line/ground ±1 kV ±1 kV ±2 kV ±2 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V 10 V 10 V 10 V
EMC interference immunity
Standard applications
Navy applications Railway
applications (trackside)
Substation applications
Page 33
Installation RSPM
Release
15
04/2018
33
Damped vibration – DC supply connection
EN 61000-4-12 IEEE C37.90.1
line/ground 2.5 kV
EN 61000-4-12 IEEE C37.90.1
line/line 1 kV
Damped oscillation - data line
EN 61000-4-12 IEEE C37.90.1
line/ground 2.5 kV
EN 61000-4-12 line/line ±1 kV
Pulse magnetic field
EN 61000-4-9 300 A/m
Stability Standard applications Navy applications Railway applications
(trackside)
Substation applications
IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with
0.14 in. (3.5 mm) amplitude
2 Hz ... 13.2 Hz with
0.04 in (1 mm) amplitude
2 Hz ... 9 Hz with 0.11 in
(3 mm) amplitude
8.4 Hz ... 150 Hz with 1g —
13.2 Hz ... 200 Hz with 0.7 g —
9 Hz ... 200 Hz with 1 g
200 Hz ... 500 Hz with
1.5 g
IEC 60068-2-27, test Ea Shock 15 g at 11 ms 10 g at 11 ms
EMC interference immunity
Standard applications
Navy applications Railway
applications (trackside)
Substation applications
Page 34
34
Installation RSPM
Release 15 04/2018
Network range
Note: The line lengths specified for the transceivers apply for the respective fiber data (fiber attenuation and BLP/dispersion).
Product code M-FAST­SFP-...
Mo de
a
a. MM = Multimode, SM = Singlemode, LH = Singlemode Longhaul
Wave length
Fiber System
attenuatio n
Example for F/O cable length
b
b. Including 3 dB system reserve when compliance with the fiber data is observed.
Fiber attenuation
BLP/ Dispersion
-MM/LC... MM 1310 nm 50/125 µm 0 dB ... 8dB
0 mi ...
3.11 mi (0 km ... 5km)
1.0 dB/km 800 MHz×km
-MM/LC... MM 1310 nm 62.5/125 µm 0 dB ... 11 dB
0 mi ...
2.49 mi (0 km ... 4km)
1.0dB/km 500MHz×km
-SM/LC... SM 1310 nm 9/125 µm 0 dB ... 13 dB
0 mi ...
15.53 mi (0 km ... 25 km)
0.4dB/km 3.5ps/ (nm×km)
-SM+/LC... SM 1310 nm 9/125 µm 10 dB ... 29 dB
15.53 mi ...
40.39 mi (25 km ... 65 km)
0.4dB/km 3.5ps/ (nm×km)
-LH/LC... SM 1550 nm 9/125 µm 10 dB ... 29 dB
29.20 mi ...
64.62 mi (47 km ... 104 km)
0.25 dB/km 19 ps/(nm×km)
-LH/LC... SM 1550 nm 9/125 µm 10 dB ... 29 dB
14.29 mi ...
86.99 mi (55 km ... 140 km)
0.18 dB/km
c
c. With ultra-low-loss optical fiber.
18 ps/(nm×km)
Table 5: Fiber port 100BASE-FX (SFP fiber optic Fast Ethernet Transceiver)
10/100/1000 Mbit/s twisted pair port
Length of a twisted pair segment max. 328 ft (100 m) (for Cat5e cable)
Table 6: Network range: 10/100/1000 Mbit/s twisted pair port
Page 35
Installation RSPM
Release 15 04/2018
35
Power consumption/power output
The order numbers correspond to the product codes of the devices.
See “Device name and product code” on page 17.
6 Scope of delivery, order numbers and
accessories
6.1 Scope of delivery
6.2 Accessories
Note that products recommended as accessories may have different characteristics to those of the device, which may limit the application range of the overall system. For example, if you add an accessory with IP20 to a device with IP65, the degree of protection of the overall system is reduced to IP20.
Device name Maximum
power consumption
a
a. You can find the total power consumption specifications for basic modules that are to be
installed in the “User Manual Installation RSPE”.
Power output
RSPM20-4Z64Z6... 9 W 31 Btu (IT)/h RSPM20-4T14T1... 2 W 7 Btu (IT)/h RSPM20-4T14Z6... 5 W 17 Btu (IT)/h RSPM22-4T14T1... including PoE output power 2 W 7 Btu (IT)/h RSPM22-4T14Z6... including PoE output power 5 W 17 Btu (IT)/h
Number Article
1 × General safety instructions 1× Device
Name Order number
Protection cap for RJ45 socket (50 pieces) 943 936-001 Protection cap for SFP slot (25 pieces) 943 942-001 Cover panel for unused module slot 942-131-001
Page 36
36
Installation RSPM
Release 15 04/2018
Fast Ethernet SFP transceiver Order number
M-FAST SFP-TX/RJ45 942 098-001 M-FAST SFP-TX/RJ45 EEC 942 098-002 The following operating conditions apply to twisted pair transceivers:
Usable with:
- HiOS as of software version 03.0.00
- for PRP ports on RSP devices, as of software version 02.0.01
- for PRP ports on EES devices, as of software version 02.0.02
- Classic switch software as of software version 08.0.00
- HiSecOS as of software version 01.2.00
Longer RSTP switching times and link loss detection times compared to twisted pair ports
provided by the device directly.
Not applicable for combo ports.Not applicable for ports which support only Gigabit Ethernet.To set autocrossing manually is currently not possible.
M-FAST SFP-MM/LC 943 865-001 M-FAST SFP-MM/LC EEC 943 945-001 M-FAST SFP-SM/LC 943 866-001 M-FAST SFP-SM/LC EEC 943 946-001 M-FAST SFP-SM+/LC 943 867-001 M-FAST SFP-SM+/LC EEC 943 947-001 M-FAST SFP-LH/LC 943 868-001 M-FAST SFP-LH/LC EEC 943 948-001 SFP-FAST-MM/LC
a
a. You find further information on certifications on the Internet at the Hirschmann product
pages (www.hirschmann.com).
942 194-001
SFP-FAST-MM/LC EEC
a
942 194-002
SFP-FAST-SM/LC
a
942 195-001
SFP-FAST-SM/LC EEC
a
942 195-002
Page 37
Installation RSPM
Release 15 04/2018
37
7 Underlying technical standards
The device has an approval based on a specific standard only if the approval indicator appears on the device casing. If your device has a shipping approval according to Germanischer Lloyd, you find the approval mark printed on the device label. You will find out whether your device has other shipping approvals on the Hirschmann website under www.hirschmann.com in the product information. The device generally fulfills the technical standards named in their current versions.
Name
CSA C22.2 No. 142 Canadian National Standard(s) – Process Control Equipment –
Industrial Products
ANSI/ISA-12.12.01 Nonincendive Electrical Equipment for Use in Class I and II,
Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
EN 50121-4 Railway applications – EMC – Emission and immunity of the
signaling and telecommunications apparatus (Rail Trackside)
EN 55032 Electromagnetic compatibility of multimedia equipment –
Emission Requirements
EN 60950-1 Information technology equipment – Safety – Part 1: General
requirements
EN 61000-6-2 Electromagnetic compatibility (EMC) – Part 6-2: Generic
standards – Immunity for industrial environments
EN 61131-2 Programmable controllers – Part 2: Equipment requirements and
tests FCC 47 CFR Part 15 Code of Federal Regulations German Lloyd Classification and Construction Guidelines VI-7-3 Part 1 Ed.2003 IEC/EN 61850-3 Communication networks and systems for power utility
automation - Part 3: General requirements. IEEE 1613 IEEE Standard Environmental and Testing Requirements for
Communication Networking Devices in Electric Power
Substations IEEE 802.1AB Station and Media Access Control Connectivity Discovery IEEE 802.1D MAC Bridges (switching function) IEEE 802.1Q Virtual LANs (VLANs, MRP, Spanning Tree) IEEE 802.3 Ethernet UL/IEC 61010-1, UL/
IEC 61010-2-201
Safety for Control Equipment
UL 60950-1 Information technology equipment – Safety – Part 1: General
requirements
Table 7: List of the technical standards
Page 38
38
Installation RSPM
Release 15 04/2018
A Further support
Technical questions
For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly.
You find the addresses of our partners on the Internet at http://
www.hirschmann.com.
A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at https://
hirschmann-support.belden.eu.com.
This site also includes a free of charge knowledge base and a software download section.
Hirschmann Competence Center
The Hirschmann Competence Center is ahead of its competitors on three counts with its complete range of innovative services:
Consulting incorporates comprehensive technical advice, from system
evaluation through network planning to project planning.
Training offers you an introduction to the basics, product briefing and user
training with certification. You find the training courses on technology and products currently available at http://www.hicomcenter.com.
Support ranges from the first installation through the standby service to
maintenance concepts.
With the Hirschmann Competence Center, you decided against making any compromises. Our client-customized package leaves you free to choose the service components you want to use.
Internet:
http://www.hicomcenter.com
Page 39
Installation RSPM
Release 15 04/2018