Hirschmann RS2-FX-LH/FX-LH, RS2-FX-SM/FX-SM, RS2-FX-SM/FX-LH, RS2-FX/FX ST, RS2-FX/FX Description And Operating Instructions

...
Description and operating instructions Industrial ETHERNET Rail Switch 2 Family
RS2-…/…
Order No.
943 …-50.
The Rail Switch RS2 has been especially designed for use in industrial environments. It supports ETHERNET 10 MBit/s and Fast ETHERNET 100 MBit/s.
The RS2…/… modules – RS2-TX/TX – RS2-FX/FX – RS2-FX/FX ST – RS2-FX/FX NAVY – RS2-FX-SM/FX-SM) – RS2-FX-SM/FX-LH – RS2-FX-LH/FX-LH are manageable. They support SNMP and Web based management.
The Rail Switch modules support switched ETHERNET networks in accordance with IEEE standard 802.3 using copper technology, and backbones in accordance with IEEE standard 802.3u using copper technology or optical waveguide (F/O), in both line and ring structures. The switch modules are plugged onto the standard bar.
The RS2…/… modules have five 10/100 Mbit/s twisted pair (TP/TX) ports (RJ45 connectors) and two backbone ports (100 Mbit/s Ports). Depending on the model, the backbone ports to connect further more RS2-…/… are available with FX or TX inter­faces (SC or RJ45 connectors).
It is possible to connect data terminal equipments or other network segments to the 10/100 Mbit/s ports using twisted pair cabling TP/TX. The ports support auto negotiation and autopolarity.
The RS2…/… modules in addition have one V.24 interface for external management and one „Stand by“ port (RJ45 connector).
The built-in control intelligence supports redundant links between networks.
In the„RS2-…/… Management Manual – Industrial ETHERNET Rail Switch 2“ you find a detailled description on the RS2 Rail Switch.
F, the Hirschmann network manage­ment system, is the optimum management solution for this product. Your sales partner keeps information ready.
RS2-TX/TX RS2-FX/FX
RS2-FX/FX ST RS2-FX-SM/FX-SM
RS2-FX-SM/FX-LH RS2-FX-LH/FX-LH
Hirschmann. Simply a good Connection.
RS2-TX/TX
i
+24V
Fault
+24V*
Stand byP1RM
FAULT
P2
76
54
32
0
1
2
RM Stand by
V.24
7
6
54
32
1
Stand by
RS2-FX/FX
i
+24V
Fault
+24V*
Stand byP1RM
FAULT
P2
76
54
32
0
1
2
RM Stand by
V.24
RS2-FX/FX ST
i
+24V
Fault
+24V*
Stand byP1RM
FAULT
P2
76
54
32
0
1
1
RM Stand by
V.24
7
6
54
32
1
Stand by
RS2-FX-SM/FX-SM
i
+24V
Fault
+24V*
FAULT
P2
Stand byP1RM
76
54
32
2
0
1
RM Stand by
V.24
RS2-FX-SM/FX-LH
i
+24V
Fault
+24V*
FAULT
P2
Stand byP1RM
76
54
32
7 LH
6 SM
54
2
0
1
RM Stand by
V.24
32
1
Stand by
RS2-FX-LH/FX-LH
i
+24V
Fault
+24V*
P2
Stand byP1RM
FAULT
76
54
32
2
0
1
RM Stand by
V.24
7
6
54
32
1
Stand by
7
6
54
32
1
Stand by
7
6
54
32
1
Stand by
2
The performance features described here are binding only if they have been expressly guaranteed in the contract. We have checked that the contents of the technical publication agree with the hardware and software described. However, it is not possi­ble to rule out deviations completely, so we are unable to guarantee complete agree­ment. However, the details in the technical publication are checked regularly. Any cor­rections which prove necessary are contai­ned in subsequent editions. We are grateful for suggestions for improvement.
We reserve the right to make technical modifications.
Permission is not given for the circulation or reproduction of this document, its use or the passing on of its contents unless gran­ted expressly. Contravention renders the perpetrator liable for compensation for damages. All rights reserved, in particular in the case of patent grant or registration of a utility or design.
Copyright © Hirschmann Automation and Control GmbH 2005 All Rights Reserved
Note
We would point out that the content of these operating instructions is not part of, nor is it intended to amend an earlier or exi­sting agreement, permit or legal relation­ship. All obligations on Hirschmann arise from the respective purchasing agreement which also contains the full warranty condi­tions which have sole applicability. These contractual warranty conditions are neither extended nor restricted by comments in these operating instructions.
We would furthermore point out that for reasons of simplicity, these operating instructions cannot describe every conceivable problem associated with the use of this equipment. Should you require further information or should particular problems occur which are not treated in sufficient detail in the operating instruc­tions, you can request the necessary infor­mation from your local Hirschmann sales partner or directly from the Hirschmann office (address: refer to chapter entitled „Notes on CE identification“).
Safety Instructions
This manual contains instructions which must be observed to ensure your own per­sonal safety and to avoid damage to devices and machinery. The instructions are highlighted with a warning triangle and are shown as follows according to the degree of endan­germent:
z
Danger!
means that death, serious injury or considerable damage to property will result if the appropriate safety measures are not taken.
z
Warning!
means that death, serious injury or considerable damage to property can result if the appropriate safety measures are not taken.
z
Caution!
means that light injury or damage to property can result if the appropria­te safety measures are not taken.
Note: is an important piece of information about the product, how to use the product, or the relevant section of the documentati­on to which particular attention is to be drawn.
Certified usage
Please observe the following:
z
Warning
The device may only be employed for the purposes described in the catalog and technical description, and only in conjunction with external devices and components recommen­ded or approved by Hirschmann. The product can only be operated correctly and safely if it is transpor­ted, stored, installed and assembled properly and correctly. Furthermore, it must be operated and serviced carefully.
Safety Guidelines Power Supply
Switch the basic devices on only when the case is closed.
z
Warning!
The devices may only be connected to the supply voltage shown on the type plate.
The devices are designed for operation with a safety extra-low voltage.Thus, they may only be connected to the supply voltage connections and to the signal contact with PELV circuits or alternatively SELV circuits with the voltage restrictions in accordance with IEC/EN 60950.
For the case where the module is opera­ted with external power supply: Use only a safety extra-low voltage in accordance with IEC 950/EN 60 950/VDE 0805 to power the system.
First of all you connect the protecting line, before you establish the further connections. When you remove connec­tions, you disconnect the protecting line last.
Relevant for North America: The subject unit is to be suppplied by a Class 2 power source complying with the requirements of the National Electrical Code, table 11(b). If power is redundant supplied (two individual power sources) the power sources together should comply with the requirements of the Na-tional Electrical Code, table 11 (b).
Power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods [Article 501-4(b) of the National Electrical Code, NFPA 70] and in accordance with the authority having juris­diction.
Peripheral equipment must be suitable for the location it is used in.
For use in Class 2 circuits. Use 60/75°C or 75°C copper(CU)wire only.
Safety Guidelines Shielding Ground
Note: The shielding ground of the connec-
table twisted pairs lines is connected to the front panel as a conductor.
Beware of possible short circuits when connecting a cable section with conductive shielding braiding.
Safety Guidelines Housing
z
Warning!
Only technicians authorized by Hir­schmann are permitted to open the housing.
Note: The device is grounded via the sepa­rated ground screw. It is located on the left under the front panel.
Make sure that the electrical installation meets local or nationally applicable safety regulations.
z
Warning!
The ventilation slits must not be covered so as to ensure free air cir­culation.
The distance to the ventilation slots of the housing has to be a minimum of 10 cm.
Never insert pointed objects (thin screwdrivers, wires, etc.) into the inside of the subrack! Failure to observe this point may result in inju­ries caused by electric shocks.
Note: If installed in a living area or office environment, the device must be operated exclusively in switchgear cabinets with fire protection characteristics according to EN
60950. Note: The housing has to be mounted in
upright position.
Safety Guidelines Environment
z
Warning!
The device may only be operated in the listed ambient temperature range at the listed relative air humi­dity (non-condensing).
The installation location is to be selec­ted so as to ensure compliance with the cli­matic limits listed in the Technical Data.
To be used in an up to Pollution Degree 2 environment only (IEC 60664-1).
Staff qualification requirements
Note: Qualified personnel, as understood
in this manual and in the warning signs, are persons who are familiar with the setup, assembly, startup, and operation of this product and are appropriately qualified for
3
Fig. 1: Overview interfaces, display elements and controls of the RS2-/
UL 508:1998 Underwriters Labratories
Inc. Safety for Industrial Control Equip­ment.
– UL 1604 Electrical Equipment for Use in
Class I and Class II, Div. 2 and Class III Hazardous (Classified).
– UL 60950 Safety for Information
Technology Equipment. Certified devices are marked with a certification identifier.
7
Notes on CE identification
The devices comply with the regula­tions of the following European directive:
89/336/EEC Council Directive on the harmoniza­tion of the legal regulations of mem­ber states on electromagnetic com­patibility (amended by Directives 91/263/EEC, 92/31/EEC and 93/68/EEC).
The EU declaration of conformity is kept available for the responsible authorities in accordance with the above-mentioned EU directives at:
Hirschmann Automation and Control GmbH Stuttgarter Straße 45-51 D-72654 Neckartenzlingen Telephone ++49-1805-14-1538
The product can be used in the resi­dential sphere (residential sphere, business and trade sphere and small companies) and in the industrial sphere. – Interference immunity:
EN 61000-6-2:2001
– Radio interference level:
EN 55022:1998 + A1 2000 + A2 2003, Class A
their job. This includes, for example, those persons who have been:
– trained or directed or authorized to
switch on and off, to ground and to label power circuits and devices or systems in accordance with current safety enginee­ring standards
– trained or directed in the care and use of
appropriate safety equipment in accor­dance with the current standards of safety engineering
– trained in providing first aid.
General Safety Instructions
This device is electrically operated. Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions!
z
Warning!
Failure to observe the information given in the warnings could result in serious injury and/or major damage.
Only personnel that have received appropriate training should operate this device or work in its immediate vicinity. The personnel must be fully familiar with all of the warnings and maintenance measures in these operating instructions.
Correct transport, storage, and assembly as well as careful operati­on and maintenance are essential in ensuring safe and reliable operation of this device.
Use only undamaged parts!
These products are only to be used in the manner indicated in this version of the Description and Operating Instructions.
Particular attention is to be paid to all warnings and items of information relating to safety.
z
Warning!
Any work that may have to be per­formed on the electrical installation should be performed by fully qualified technicians only.
z
Warning!
LED- oder LASER-Komponenten gemäß IEC 60825-1 (2001): LASER KLASSE 1 - CLASS 1 LASER PRODUCT. LICHT EMITTIERENDE DIODE KLAS­SE 1 - CLASS 1 LED PRODUCT.
Based specifications and standards:
The devices fulfil the following specifications and standards: – EN 61000-6-2:1999 Generic standards –
Immunity for industrial environments
– EN 55022:1998 – Information technology
equipment – Radio disturbance characteristics
– EN 60950:1997 – Safety of Information
Technology Equipment (ITE)
– EN 61131-2:1994 – Programmable
Controllers
– CFR-47 Part 15:1997 – Code of Federal
Regulations
– Germanischer Lloyd Guidelines for the
Performance of Type Tests Part 1
z
Warning!
This is a Class A device. This equip­ment may cause radio interference if used in a residential area; in this case it is the operator´s responsibili­ty to take appropriate measures.
The precondition for compliance with EMC limit values is strict adhe­rence to the construction guidelines specified in this description and operating instructions.
FCC Note:
This equipment has been tested and found to comply with the limits for a Class A digi­tal device, persuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inter­ference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre­quency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inter­ference at his own expense.
,
Recycling Note:
After its use, this product has to be processed as electronic scrap and disposed of according to the prevai­ling waste disposal regulations of your community / district / country / state.
RS2-…
i
5pin
terminal
block
LED
display
elements
2pole
DIP switch
V.24 interface
for external
management
Fault
+24V*
+24V
FAULT
P2
Stand byP1RM
76
54
32
54
2
0
1
RM Stand by
V.24
32
Stand by
7
6
2 backbone ports (ports 6 and 7) – RS2-FX/FX: 100BASE-FX
multimode (SC connectors)
RS2-FX/FX ST: 100BASE-FX
multimode (ST connectors)
RS2-FX-SM/FX-LH RS2-FX-LH/FX-LH RS2-FX-SM/FX-SM: 100BASE-FX
singlemode (SC connectors)
RS2-TX/TX: 100BASE-TX
(RJ45 connectors)
5 ports complying with 10/100BASE-T(X) (ports 1 to 5) autonegotiaton + autopolarity