Hirschmann OZDV 2471 P, OZDV 2471 G Technical Description And Operating Instructions

Beschreibung und Betriebsanleitung Optischer Schnittstellenwandler
Description and Operating Instructions Optical interface converter
Description et manuel d’utilisation Convertisseur interface optique
OZDV 2471 P
Spannungsversorgung wahlweise durch das angeschlossene Endgerät oder über Steckernetzteil möglich
Überbrückbare Entfernungen
100 m mit Kunststoff-LWL6700 m mit Quarzglas-LWL
Bitrate: DC bis 20 kbit/s Kompakte Aufsteckmodule in stabilem
Metallgehäuse
V.24/Fibre optic interface converter; asynchronous, full duplex
Power supply either via the connected terminal device or via plug-in power supply
Maximum transmission distance
100 m using plastic fibre6700 m using quartz glass fibre
Bit rate: DC - 20 kbit/s Compact plug-in modules housed in stable
metal cases
Convertisseur interface V.24/guide d’ondes lumineuses; asynchrone, duplex intégral
Tension d’alimentation possible au choix par l’appareil terminal connecté ou par le bloc d’alimentation à connecteur
Distances de transmission: 100 m avec guide d’ondes lumineuses en
plastique
6700 m avec guide d’ondes lumineuses en
verre quartzeux Taux de bit: DC jusqu’à 20 kbits/s Modules enfichables compacts dans un boî-
tier en métal solide
Bestell-Nr. / Ord. code / N° de cde.
943 340-021 OZDV 2471 G
Bestell-Nr. / Ord. code / N° de cde.
943 341-021
,
2
Inbetriebnahme
Betriebsarteneinstellungen
Überprüfen und korrigieren Sie bei Bedarf folgende Einstellungen:
– Umschaltung „für DTE/für DCE”-Betrieb – Verbindung Schirmmasse mit Signalmasse – Wahl der Spannungsversorgung.
Umschaltung „für DTE/für DCE”-Betrieb
Je nach Erfordernis des angeschlossenen Endgerätes können Sie mit den Schiebe­schaltern S
1
(braun) und S2(rot) zwischen „für DTE”- und „für DCE”-Betrieb umschalten. (Informationen hierzu finden Sie im Handbuch des anzuschließenden Endgerätes.)
Schieben Sie zum Umschalten die Schiebeschalter mit einem spitzen Gegenstand in die entsprechende Stellung.
„für DTE”-Betrieb (werkseitig eingestellt)
„für DCE”-Betrieb
Verbindung Schirmmasse mit Signal­masse
Bei Bedarf können Sie die Schirmmasse (Pin 1 des 25poligen Sub-D Steckverbinders) mit der Signalmasse/Spannungsversorgungsmasse (Pin 7) mit dem Schiebeschalter S
3
(orange)
galvanisch verbinden.
Schieben Sie zum Umschalten den Schiebeschalter mit einem spitzen Gegenstand in die entsprechende Stellung.
Pin 1 und Pin 7 getrennt (werkseitig eingestellt)
Pin 1 und Pin 7 verbunden
Wahl der Spannungsversorgung
Wünschen Sie statt der Spannungsversorgung über ein Steckernetzteil eine Spannungsversorgung vom angeschlossenen Endgerät über den 25poligen Sub-D-Steckverbinder (Pin 11), so ist dies durch Umschalten von Schiebeschalter S
4
(gelb) möglich.
Schieben Sie zum Umschalten den Schiebeschalter mit einem spitzen Gegenstand in die entsprechende Stellung.
Spannungsversorgung über Steckernetzteil (werkseitig eingestellt)
Spannungsversorgung über Pin 11
LWL-Kabelverbindung
Verbinden Sie die beiden Schnittstellen­wandler durch ein Duplex-LWL Kabel mit BFOC (ST®) Steckverbindern. Achten Sie bitte darauf, daß jeweils ein Eingang (IN) und ein Ausgang (OUT) miteinan­der verbunden sind („Überkreuzverbindung“).
Aufstecken
Stecken Sie den 25 poligen Sub-D Steckverbinder (male) des Schnittstellenwandlers auf den entsprechen­den Anschluß am Endgerät und arretieren Sie ihn mit den beiden Rändelschrauben.
Betriebsstörungen
In folgenden Störungsfällen gehen die elektri­schen Ausgänge der Schnittstellenwandler in den High Pegel:
– Zweiter Schnittstellenwandler nicht auf
Endgerät gesteckt;
– Zweites Endgerät ausgeschaltet. Sind die optischen Steckverbinder am
Schnittstellenwandler OZDV 2471 P/G nicht gesteckt, so kann – insbesondere bei hoher Umgebungshelligkeit – ein rein zufälliges Signal an den elektrischen Ausgängen anlie­gen.
Zubehör
Steckernetzteil SNT 510 Bestell-Nr. 268 109-001
Beschreibung
Eine Übertragungsstrecke, bestehend aus zwei Schnittstellenwandlern OZDV 2471 P oder OZDV 2471 G und einem Duplex-Licht­wellenleiter, ermöglicht eine störsichere, op­tische Datenübertragung von V.24 (RS-232 D) Signalen über eine Entfernung von bis zu 6700 m.
Die Übertragungsstrecke arbeitet im asyn­chronen Vollduplex-Betrieb. Sie ersetzt alle
konventionellen Vierdraht-Verbindungslei­tungen. Die Datenübertragung erfolgt über zwei optische Fasern, somit müssen die ange­schlossenen Endgeräte für Software-Hand­shake (X on/X off-Übertragung) geeignet sein. Dies ist in den jeweiligen Handbüchern der anzuschließenden Endgeräte angegeben.
Der mechanische Aufbau der Schnittstellen­wandler erfolgt als kompakte 25polige Sub-D Steckverbinder, die die gesamte Elektronik enthalten.
Die Spannungsversorgung der Schnittstellen­wandler erfolgt wahlweise durch das ange­schlossene Endgerät über den Sub-D­Steckverbinder oder über ein Steckernetzteil.
Die Schnittstellenwandler sind sowohl „für DTE“- (Data Terminal Equipment) als auch „für DCE“- (Data Communication Equipment) Betrieb geeignet. Durch einen Schiebeschalter sind sie auf den jeweiligen Betriebszustand des anzuschließenden Endgerätes (siehe Handbuch) einstellbar.
Durch eine vollständige DC-Kopplung der Schnittstellenwandler ist gewährleistet, daß sofort beim Einschalten der Endgeräte der richtige Zustand übertragen wird und beliebig lange Übertragungspausen problemlos mög­lich sind.
Durch einen Schiebeschalter kann die Schirm­masse mit der Signalmasse verbunden werden.
,,
,,,,
,,
,,
,,
,,,,
,,
,,
,,
,
,
Anwendungsbeispiel
D
OZDV 2471P/G
ABCD
ABCD
1234
1234
ABC D
123 4
ABC D
123 4
ABCD
1234
ABCD
1234
OZDV 2471P/G
3
Technische Daten
1)
Typ OZDV 2471 P OZDV 2471 G
Betriebsspannung 5 V ±5% Stromaufnahme (typ./max.) 90 mA/120 mA
V.24-Schnittstelle
Eingangsignal
– HIGH (min./max.) –30 V/–3 V – LOW (min./max.) +3 V/+30 V
Eingangsimpedanz > 3 k Ausgangssignal (V.24 (RS-232 D)-Pegel)
– HIGH (min./max.) –15 V/–5 V bei 3-7 kΩ Lastwiderstand – LOW (min./max.) +5 V/+15 V bei 3-7 kΩ Lastwiderstand
Flankensteilheit (max.) 30 V/µs Bitrate DC bis 20 kbit/s (DC-Kopplung) Bitfehlerhäufigkeit < 10
-9
Optische Schnittstelle
Wellenlänge 665 nm 860 nm Einkoppelbare optische Leistung
– in 50/125 µm Faser 30 µW
ss
, –15 dBm
– in 62,5/125 µm Faser 60 µW
ss
, –12 dBm
– in 980/1000 µm Faser 250 µW
ss
, –6 dBm
Empfindlichkeit Empfänger –38 dBm –40 dBm Überbrückbare Entfernung mit 2*)bzw. 3**)dB
Systemreserve/Streckendämpfung
– mit 50/125 µm Faser (3,0 dB/km) 0 bis 6700 m**
)
/23 dB
– mit 62,5/125 µm Faser (3,5 dB/km) 0 bis 6600 m**
)
/26 dB
– mit 980/1000 µm Faser (0,24 dB/m) 0 bis 100 m*
)
/29 dB
Schiebeschalter S11: „für DCE“-Betrieb A: „für DTE“-Betrieb
S
2
2: „für DCE“-Betrieb B: „für DTE“-Betrieb
S
3
3: Pin 1 und Pin 7 verbunden C: Pin 1 und Pin 7 getrennt
S
4
4: Spannungsversorgung über Pin 11 D: Spannungsversorgung über Steckernetzteil
Anschlüsse
Data 25poliger Sub-D-Steckverbinder, male
Beschaltung „für DTE“-Betrieb Eingang: Pin 2 (TxD), Ausgang: Pin 3 (RxD) Beschaltung „für DCE“-Betrieb Eingang: Pin 3 (RxD), Ausgang: Pin 2 (TxD)
Betriebsspannung
intern über 25poligen Sub-D-Steckverbinder (Pin 11) extern über 4polige Kleinspannungsbuchse; Bauform: M8 nach IEC 947-5-2
Opto BFOC (ST®) 2,5
EMV-Schutz
Störaussendung Erfüllt EN 55011, Grenzwertklasse B Störfestigkeit Erfüllt IEC 801-2, -3, -4
Allgemeine Daten
Umgebungstemperatur 0 °C bis +50 °C Lagerungstemperatur –20 °C bis +70 °C Relative Luftfeuchtigkeit 10% bis 90% (nicht kondensierend) Masse 110 g Gehäusewerkstoff Zink-Druckguß Abmessungen B x H x T 56 x 17 x 80 mm
1) Technische Daten die nur beim Typ OZDV 2471 P aufgeführt sind gelten auch für den Typ OZDV 2471 G
1
13
14
20
25
PGND 2 TxD/RxD 3 4 5 6
8
RxD/TxD
7 GND
11 Externe Versorgung
PGND Protective Ground TxD Transmit Data RxD Receive Data GND Ground (Data)
4
3
2
1
1NC 2 +5 V 3NC 4 Masse
GB
4
Setting up
Operational settings
Check and, if necessary, adjust the following settings:
– DTE/DCE selection – Protective ground/signal ground connec­tion – Power supply selection
DTE/DCE selection
According to the specific requirements of the connected equipment the module may be switched to either DTE (Data Terminal Equipment) or DCE (Data Communications Equipment) operation using the slide switches S
1
(brown) and S2(red) (information is con­tained in the documentation of the terminal equipment used).
Use a pointed object to push the switches to the desired position.
“for DTE” operation (factory setting)
“for DCE” operation
Protective ground/signal ground connection
If required, the protective ground (pin 1 of the
25-pin Sub-D connector) can be electrically
connected to the signal/power supply ground (pin 7) by switch S
3
(orange). Use a pointed object to push the slide switch to the desired position.
Pin 1 not connected to pin 7 (factory setting)
Pin 1 connected to pin 7
Power supply selection
If you wish power to be supplied via the 25-pin Sub-D connector (pin 11) instead of by a plug-in power supply, you can change the setting with slide switch S
4
(yellow).
Use a pointed object to push the slide switch to the desired position.
Power supply via
plug-in power supply
(factory setting)
Power supplied via pin 11
Description
A transmission link consisting of two OZDV 2471 P or OZDV 2471 G interface converters and a duplex optical fibre can provide interference-free optical data trans­mission of V.24 (RS-232 D) signals over dis­tances of up to 6700 m.
The transmission link operates in asynchro­nous full duplex mode and can replace all conventional 4-wire connections.
Data transfer takes place through two optical fibers. For that reason, the terminal equipment must be able to handle software handshaking (X on/X off transmission). The information as to whether a terminal device supports software handshaking can be found in the appropriate manuals for the device in question.
Mechanically, the interface converters are built into compact 25-pin Sub-D connectors which house all electronic components.
Power supply of the interface converters occurs either via the connected terminal devi­ce and the Sub-D connector or via a plug-in power supply.
The interface converters are suited for both DTE (Data Terminal Equipment) and DCE (Data Communication Equipment) use. A slide switch is provided for setting the converters to the individual terminal device's operational mode (refer to the appropriate manual).
Complete DC coupling of the modules gua­rantees that the correct status is immediately transmitted after switching on the equipment. This also allows the equipment to handle arbi­trarily long transmission interruptions without problem.
A slide switch is provided for connecting the protective ground to the signal ground.
,,
,,,,
,,
,,
,,
,,,,
,,
,,
,,
,
,
Sample Application
OZDV 2471P/G
ABCD
ABCD
1234
1234
OZDV 2471P/G
ABC D
123 4
ABC D
123 4
ABCD
1234
ABCD
1234
5
Technical Data
1)
Type OZDV 2471 P OZDV 2471 G
Operating voltage 5 V ±5% Current consumption (typical/max.) 90 mA/120 mA
V.24 interface
Input signal
– HIGH (min./max.) –30 V/–3 V – LOW (min./max.) +3 V/+30 V
Input impedance > 3 k Output signal (V.24 (RS-232 D) level)
– HIGH (min./max.) –15 V/–5 V at 3- 7 kload resistance – LOW (min./max.) +5 V/+15 V at 3-7 kload resistance
Slope rate (max.) 30 V/µs Bit rate DC to 20 kbit/s (DC coupling) Bit error rate < 10
-9
Optical interface
Wavelength 665 nm 860 nm Launchable optical power
– in fibre 50/125 µm 30 µW
pp
, –15 dBm
– in fibre 62,5/125 µm 60 µW
pp
, –12 dBm
– in fibre 980/1000 µm 250 µW
pp
, –6 dBm
Receiver sensitivity –38 dBm –40 dBm Maximum transmission distance with
2*
)
/3**)dB system reserve/line attenuation
– with fibre 50/125 µm (3.0 dB / km) 0 to 6700 m**
)
/23 dB
– with fibre 62.5/125 µm (3.5 dB / km) 0 to 6600 m**
)
/26 dB
– with fibre 980/1000 µm (0.24 dB/m) 0 to 100 m*
)
/29 dB
Slide switches S11: "for DCE" operation A: "for DTE" operation
S
2
2: "for DCE" operation B: "for DTE" operation
S
3
3: pins 1 and 7 connected C: pins 1 and 7 not connected
S
4
4: power supply via pin 11 D: power supply via plug-in power supply
Connections
Data 25-pin Sub-D connector, male
Connection for DTE operation input: pin 2 (TxD), output: pin 3 (RxD) Connection for DCE operation input: pin 3 (RxD), output: pin 2 (TxD)
Operating voltage
internal via 25-pin Sub-D connector (pin 11) external via 4-pole low-power socket; form of construction: M8 according to IEC 947-5-2
Optical BFOC (ST®) 2.5
EMC protection
Interference emissions meets EN 55011, class B Interference immunity meets IEC 801-2, -3, -4
General data
Ambient temperature 0 °C to +50 °C Storage temperature –20 °C to +70 °C Relative humidity 10% to 90% (non condensing) Mass 110 g Housing material die cast zinc Dimensions W x H x D 56 x 17 x 80 mm
1) Technical data given only for the OZDV 2471 P is also valid for the OZDV 2471 G
1
13
14
20
25
PGND 2 TxD/RxD 3 4 5 6
8
RxD/TxD
7 GND
11 external
power supply
PGND Protective Ground TxD Transmit Data RxD Receive Data GND Ground (Data)
4
3
2
1
1NC 2 +5 V 3NC 4 Ground
F
6
Mise en service
Réglages des modes de service
Vérifier et corriger au besoin les réglages suivants:
– Commutation en mode DTE/DCE – Liaison de la protection par mise à la terre
à la masse du signal
– Choix de la tension d’alimentation
Commutation en mode DTE/DCE
Les interrupteurs à coulisse S
1
(marron) et S
2
(rouge) permettent de commuter entre les modes DTE et DCE selon les conditions de l’appareil terminal connecté. (Les informations à ce sujet figurent dans le manuel de l’appar­eil terminal à connecter.)
Poussez pour commuter l’interrupteur à coulisse avec un objet pointu sur la position correspondante.
Mode DTE (réglage en usine)
Mode DCE
Liaison de la protection par mise à la terre à la masse du signal
Au besoin, la protection par mise à la terre (broche 1 du connecteur enfichable sub-D à 25 pôles) peut recevoir une liaison galvanique à la masse du signal/masse de la tension d’alimentation (broche 7) à l’aide de l’inter­rupteur à coulisse S
3
(orange).
Poussez pour commuter l’interrupteur à coulisse avec un objet pointu sur la position correspondante.
Broches 1 et 7 séparées (réglage en usine)
Broches 1 et 7 reliées
Choix de la tension d’alimentation
Si une alimentation en tension, depuis l’appa­reil terminal connecté par l’intermédiaire du connecteur enfichable sub-D à 25 pôles (broche 11), est désirée à la place de la tension d’alimentation par le bloc d’alimentation à connecteur, cela est possible en commutant l’interrupteur à coulisse S
4
(jaune).
Poussez pour commuter l’interrupteur à coulisse avec un objet pointu sur la position correspondante.
Alimentation en tension par le bloc d’alimentation
à connecteur
(réglage en usine)
Alimentation en tension par la broche 11
Liaison par câble du guide d’ondes lumineuses
Relier les deux convertisseurs interfaces par un câble pour guide d’ondes lumineuses duplex avec des connecteurs enfichables BFOC (ST®). Veiller à chaque fois à ce qu’une entrée (IN) et une sortie (OUT) soient reliées entre elles (“liaison entrecroisée”).
Connexion
Brancher le connecteur enfichable sub-D à 25 pôles (mâle) du convertisseur interface au connecteur correspondant de l’appareil terminal et le bloquer avec les deux vis moletées
Anomalies de service
Lors des anomalies suivantes, les sorties électriques des convertisseurs interfaces passent en niveau fort:
– le second convertisseur interface n’est pas
branché à l’appareil terminal
– le second appareil terminal est débranché. Si les connecteurs enfichables optiques ne
sont pas en place sur le convertisseur inter­face OZDV 2471 P/G, un signal purement stochastique peut surgir aux sorties électri­ques – en particulier lors d’une luminosité ambiante élevée.
Accessoires
Bloc d’alimentation à connecteur SNT 510 N° de cde. 268 109-001
Description
Un lien de transmission, se composant de deux convertisseurs interfaces OZDV 2471 P ou OZDV 2471 G et d’un guide d’ondes lumineuses duplex, permet une transmission optique sans interférence des données de signaux V.24 (RS-232 D) sur une distance comportant jusqu’à 6700 m.
Le lien de transmission fonctionne en mode duplex intégral asynchrone. Il remplace tous
les câbles conventionnels de liaison à quatre âmes. La transmission des données s’effectue par deux fibres optiques: les appareils termi­naux connectés doivent ainsi être appropriés à l’établissement de liaison (handshake) du logiciel (transmission X on/X off). Cela est indiqué dans les manuels respectifs des appareils terminaux à connecter.
Les convertisseurs interfaces sont conçus mécaniquement comme connecteurs enfich­ables sub-D à 25 pôles renfermant l’électro­nique au complet.
L’alimentation en tension des convertisseurs interfaces est réalisée au choix par l’appareil terminal connecté, au moyen des connecteurs enfichables sub-D, ou par un bloc d’alimenta­tion à connecteur.
Les convertisseurs interfaces sont appropriés aussi bien au mode DTE (Data Terminal Equipment) qu’au mode DCE (Data Communication Equipment). Ils peuvent être ajustés sur le mode de service correspondant de l’appareil terminal connecté grâce à un interrupteur à coulisse (consulter le manuel).
Le couplage intégral DC des convertisseurs interfaces garantit que l’état correct est trans­mis dès l’enclenchement des appareils termi­naux et que des interruptions de transmission d’une durée quelconque sont possibles sans problème.
L’interrupteur à coulisse permet de relier la protection par mise à la terre à la masse du signal.
,,
,,,,
,,
,,
,,
,,,,
,,
,,
,,
,
,
Exemple d’application
OZDV 2471P/G
ABCD
ABCD
1234
1234
ABC D
ABC D
ABCD
ABCD
OZDV 2471P/G
123 4
123 4
1234
1234
7
Données techniques
1)
Type OZDV 2471 P OZDV 2471 G
Tension de service 5 V ± 5% Consommation de courant (typique/maximale) 90 mA/120 mA
Interface V.24
Signal d’entrée
– élevé (HIGH) (min./max.) –30 V/–3 V – bas (LOW) (min./max.) +3 V/+30 V
Impédance d’entrée > 3 k Niveau du signal de sortie (V.24 / RS-232 D)
– élevé (HIGH) (min./max.) –15 V/–5 V pour une résistance de charge de 3-7 k – bas (LOW) (min./max.) +5 V/+15 V pour une résistance de charge de 3-7 k
Pente du signal (max.) 30 V/µs Taux de bits DC jusqu’à 20 kbits/s (couplage DC) Fréquence d’erreur sur les bits < 10
-9
Interface optique
Longueur d’ondes 665 nm 860 nm Puissance optique modulable
– dans fibre de 50/125 µm 30 µW
ss
, –15 dBm
– dans fibre de 62,5/125 µm 60 µW
ss
, –12 dBm
– dans fibre de 980/1000 µm 250 µW
ss
, –6 dBm
Sensibilité récepteur –38 dBm –40 dBm Distance de transmission avec 2*)ou 3**)dB
réserve du système /affaiblissement de propagation
– avec fibre de 50/125 µm (3,0 dB/km) 0 à 6700 m**
)
/23 dB
– avec fibre de 62,5/125 µm (3,5 dB/km) 0 à 6600 m**
)
/26 dB
– avec fibre de 980/1000 µm (0,24 dB/m) 0 à 100 m*
)
/29 dB
Interrupteurs à coulisse S11: mode DCE A: mode DTE
S
2
2: mode DCE B: mode DTE
S
3
3: broches 1 et 7 reliées C: broches 1 et 7 séparées
S
4
4: alimentation en tension par D: alimentation en tension par
broche 11 le bloc d’alimentation à connecteur
Connexions
Données connecteur enfichable sub-D à 25 pôles (mâle)
Circuit d’enclenchement pour mode DTE entrée: broche 2 (TxD), sortie: broche 3 (RxD) Circuit d’enclenchement pour mode DCE entrée: broche 3 (RxD), sortie: broche 2 (TxD)
Tension de service
Interne par connecteur enfichable sub-D à 25 pôles (broche 11) Externe par douille pour faibles tensions à quatre pôles; construction M8 selon IEC 947-5-2
Optique BFOC (ST®) 2,5
Protection CEM
Emission de parasites conforme à EN 55011, classe de valeur limite B Résistance aux parasites conforme à IEC 801-2, -3, -4
Caractéristiques générales
Température ambiante 0 °C à +50 °C Température d’entreposage –20 °C à +70 °C Humidité relative 10% à 90% (non condensable) Masse 110 g Matériau du boîtier zinc moulé sous pression Dimensions L x H x P 56 x 17 x 80 mm
1) Les données techniques qui ne sont listées que pour le type OZDV 2471 P sont également valables pour le type OZDV 2471 G
1
13
14
20
25
PGND 2 TxD/RxD 3 4 5 6
8
RxD/TxD
7 GND
11 Alimentation externe
PGND protection par mise à la terre / Protective Ground TxD transmission des données / Transmit Data RxD réception des données / Receive Data GND mise à la terre (données) / Ground (Data)
4
3
2
1
1NC 2 +5 V 3NC 4 Masse
943 341-901-03-798 Printed in Federal Republic of Germany
Richard Hirschmann GmbH & Co Steckverbindungstechnik Industrie Industrial Interconnection Technology Service connectique Stuttgarter Strasse 45 - 51 D-72654 Neckartenzlingen Tel.: ++49 / 7127/ 14-1850 Fax: ++49 / 7127/ 14-1495
Technische Änderungen vorbehalten Technical changes reserved
Loading...