Hirschmann OS20–001000T5T5TAFUHB, OS24–081000T5T5TFFUHB, OS20–001000T5T5TNEUHB, OS24–081000T5T5TNEUHB User Manual

User Manual
OS20–001000T5T5TAFUHB OS20–001000T5T5TNEUHB
OS24–081000T5T5TNEUHBOS24–081000T5T5TFFUHB
Power
N.C.
N.C.
P-
1 2 3 4 5
P2+
Pin
Function P1+
1
2
3
4
5
Power
49
5
10
1
3
287
6
P1
P2
x y
OCTOPUS
OS20
Unmanaged
ETHERNET Switch
Power
N.C. P-
1 2 3 4
N.C.
Pin
Function P+
Power
1
2
4
3
P
4
5
1
3
2
9
10
8
7
6
x y
OCTOPUS
OS20
Unmanaged
ETHERNET Switch
OS20-001000T5T5TNEUHB
Power
N.C.
1 2 3 4 5
P2+
Pin Function
P1+
Power
4
5
1
2
3
P-
P1
4
5
1
3
2
9
10
8
7
6
PoE
PoE
P2
FAULT
x y
OCTOPUS
OS24
Unmanaged
ETHERNET Switch
OS24-081000T5T5TFFUHB
P
Port 2-5, 7-10
Power
N.C. P-
1 2 3 4
N.C.
Pin Function
P+
Power
1
2
4
3
4
5
1
3
2
9
10
8
7
6
PoE
PoE
FAULT
P
x y
OCTOPUS
OS24
Unmanaged
ETHERNET Switch
P
Port 2-5, 7-10
OS20-001000T5T5TAFUHB
OS24-081000T5T5TNEUHB
OCTOPUS OS20/OS24 Unmanaged
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
Technical support
https://hirschmann-support.belden.eu.com
The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone.
© 2015 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is not permitted, either in whole or in part. An exception is the preparation of a backup copy of the software for your own use. For devices with embedded software, the end-user license agreement on the enclosed CD/DVD applies.
The performance features described here are binding only if they have been expressly agreed when the contract was made. This document was produced by Hirschmann Automation and Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right to change the contents of this document without prior notice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network components or the associated operating software. In addition, we refer to the conditions of use specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com).
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 1805 141538
OCTOPUS OS20/OS24 Unmanaged 039 771 001-08-0715 07.07.2015

Contents

Safety instructions 5
About this Manual 10
Legend 10
1 Description 11
1.1 General device description 11
1.2 Device name and product code 12
1.3 Device view 14
1.4 Power supply 18
1.4.1 Supply voltage with the characteristic value A 18
1.4.2 Supply voltage with the characteristic value F 18
1.4.3 Supply voltage with the characteristic value N 18
1.5 Ethernet ports 18
1.5.1 10/100 Mbit/s twisted pair port 18
1.5.2 10/100 Mbit/s PoE port 19
1.5.3 Pin assignments 20
1.6 Display elements 20
2 Installation 22
2.1 Checking the package contents 22
2.2 Connecting the connector for the supply voltage 22
2.2.1 Devices featuring supply voltage with the
characteristic value A 22
2.2.2 Devices featuring supply voltage with the
characteristic value F 23
2.2.3 Devices featuring supply voltage with the
characteristic value N 24
2.3 Installing and grounding the device 25
2.3.1 Grounding the device 26
2.4 Connecting the ferrite 26
2.5 Connecting the supply voltage 27
2.6 Operating the device 27
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
3
2.7 Connecting data cables 28
3 Monitoring the ambient air temperature 29
4 Maintenance and service 30
5 Technical data 31
A Further Support 38
Installation OCTOPUS OS20/OS24 Unmanaged
4
Release 08 07/2015

Safety instructions

WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

General safety instructions

You operate this device with electricity. Improper usage of the device entails the risk of physical injury or significant property damage. The proper and safe operation of this device depends on proper handling during transportation, proper storage and installation, and careful operation and maintenance procedures. Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.The device is free of any service components. In case of a damaged
or malfunctioning the device, turn off the supply voltage and return the device to Hirschmann for inspection.

Certified usage

Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 31.
Connect to the product only components suitable for the requirements
of the specific application case.
Certification type
See “Device name and product code” on page 12.
E In the inside of buildings
F In the inside of buildings
Table 1: Operational environment
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
Operational environment
In the inside of trains
In the inside of trains In the inside of ships In the inside of vehicles
5

Device casing

Only technicians authorized by the manufacturer are permitted to open the casing. Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not touch the connection terminals.
At ambient temperatures > 140 °F (60 °C):
The surfaces of the device housing may become hot. Avoid touching the device while it is operating.

Qualification requirements for personnel

Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the prerequisite for grounding and labeling circuits, devices, and systems in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.

National and international safety regulations

Verify that the electrical installation meets local or nationally applicable
safety regulations.

Grounding the device

The housing is grounded via the separate ground screw on the bottom left of the front panel. Use a wire diameter for the ground conductor that is no smaller than
the diameter of the supply voltage connection, however of at least
0.75 mm² (AWG18).
Ground the device before connecting any other cables.Disconnect the grounding only after disconnecting all other cables.

Shielding ground

The overall shield of a connected shielded twisted-pair cable is connected to the metal housing as a conductor. Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
Installation OCTOPUS OS20/OS24 Unmanaged
6
Release 08 07/2015

Supply voltage

The supply voltage is electrically isolated from the housing.
Use undamaged parts.Relevant for North America:
Only use copper wire/conductors of class 1, 75 °C.
Applies to devices featuring supply voltage with the characteristic
value F: Exclusively connect SELV circuits with the voltage restrictions in accordance with IEC/EN 60950-1 to the supply voltage connections.
Applies to devices featuring supply voltage with the characteristic
value A: Ensure that the externally power unit connected upstream fulfills one of following conditions:
NEC Class 2Limited Power Source based on EN 60950-1

Operating conditions

Operate the device at the specified ambient temperature (temperature of the ambient air at a distance of 2 inches (5 cm) from the device) and at the specified relative humidity exclusively. Install the device in a location where the climatic threshold values
specified in the technical data are adhered to. Make sure the environment does not heat the device.
Use the device in an environment with a maximum pollution degree
that complies with the specifications in the technical data.

Relevant for use in North America

Use this device solely in Class 2 Circuits.
Relevant for usage under conditions that comply with the
the technical standard UL 60950-1:
Note: The following information applies only to device variants with UL 60950-1 approval and protective conductor connection.
Protective conductor connection for the crimp connection: Use a wire diameter for the ground conductor that is no smaller than the diameter of the supply voltage connection, however of at least 0.75 mm² (AWG18). Use a professional crimping tool specified for the wire size. Follow the instruction of the crimping tool. The pull out force the crimped connection is at least 135 N according to the technical standard IEC 60352-2.
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
7

E marking

The labeled devices comply with the regulations contained in the following European directive(s):
Rule No. 10 of the Economic Commission for Europe (ECE): Devices with an approval are labeled with the E type-approval mark. (Relevant for devices with certification type F)

CE marking

The labeled devices comply with the regulations contained in the following European directive(s):
2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
2006/95/EC Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electrical equipment to be used within specific voltage ranges.
2004/108/EC (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility.
In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address:
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 1805 141538
The device can be used in the industrial sector.
Interference immunity: EN 61000-6-2Emitted interference: EN 55022
Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures.
Note: The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values.
Installation OCTOPUS OS20/OS24 Unmanaged
8
Release 08 07/2015

FCC note:

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation. Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations. These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment. The device creates and uses high frequencies and can also radiate these frequencies. If it is not installed and used in accordance with this operating manual, it can cause radio transmission interference. The use of this device in a residential area can also cause interference, and in this case the user is obliged to cover the costs of removing the interference.

Recycling note

After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country.
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
9

About this Manual

The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device.

Legend

The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
10
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015

1 Description

1.1 General device description

The OCTOPUS OS20/OS24 Unmanaged devices are designed for the special requirements of industrial automation. They meet the relevant industry standards, provide very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility.
The devices allow you to set up switched industrial Ethernet networks that conform to the IEEE 802.3 standard in the line structure.
The devices work without a fan.
The 10 twisted pair ports are M12 sockets.
The twisted pair ports support:
AutocrossingAutonegotiation Autopolarity
Mount the device on a level surface with four M5 screws. The Hirschmann network components help you ensure continuous communication across all levels of the company.
Connect your devices to:
devices of the OCTOPUS familydevices of the Open Rail familydevices of the MICE familybackbone devices of the MACH familythe BAT wireless transmission systemthe EAGLE security systemproducts for the LION control room / MACH 100 family
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
11

1.2 Device name and product code

The device name corresponds to the product code. The product code is made up of characteristics with defined positions. The characteristic values stand for specific product properties. You have numerous options of combining the device characteristics. You can determine the possible combinations using the configurator which is available in the Belden E-Catalog (www.e-catalog.beldensolutions.com) on the web page of the device.
Item Product
characteristic
1 ... 4 Product OS20 Octopus device with Fast Ethernet ports
5 (hyphen) — 6 ... 7 Number:
Special ports
8 ... 9 Number:
100 Mbit/s ports
10 ... 11 Number:
1000 Mbit/s ports
12 ... 13 uplink port T5 1 × 100 Mbit/s ports
14 ... 15 uplink port T5 1 × 100 Mbit/s ports
16 Temperature range T Extended 40 °F ... +158 °F (40 °C ...
Product code
OS24 Octopus device
00 0 × PoE(+) ports 08 8 × PoE(+) ports 10 10 × 100 Mbit/s ports
00 0 × 1000 Mbit/s ports
Value for the characteristic
without PoE ports with Fast Ethernet ports
with PoE+ ports
Twisted pair M12
Twisted pair M12
+70 °C)
Table 2: Device name and product code
12
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015