Hirschmann OCTOPUS OS3 User Manual

Installation OCTOPUS OS3
Release 01 02/2019
Technical support
https://hirschmann-support.belden.com
Installation
Managed Ethernet Switch OCTOPUS OS3
The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone.
© 2019 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is not permitted, either in whole or in part. An exception is the preparation of a backup copy of the software for your own use.
The performance features described here are binding only if they have been expressly agreed when the contract was made. This document was produced by Hirschmann Automation and Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right to change the contents of this document without prior notice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network components or the associated operating software. In addition, we refer to the conditions of use specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com).
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany
8.2.19
Installation OCTOPUS OS3
Release 01 02/2019
3
Contents
Safety instructions 5
About this manual 10
Key 11
1 Description 12
1.1 General device description 12
1.2 Device name and product code 12
1.3 Device views 14
1.3.1 Front view 14
1.4 Power supply 15
1.4.1 Supply voltage with the characteristic value N9 15
1.5 Ethernet ports 15
1.6 Pin assignments 16
1.7 Display elements 17
1.7.1 Device state 17
1.7.2 Port Status 19
1.8 Management interfaces 20
1.8.1 V.24 interface (external management) 20
1.8.2 USB interface 20
1.9 Input/output interfaces 21
1.9.1 Signal contact 21
2 Installation 22
2.1 Checking the package contents 22
2.2 Installing and grounding the device 23
2.2.1 Mounting on a flat surface 23
2.2.2 Grounding the device 24
2.3 Connecting the supply voltage 25
2.4 Connecting data cables 26
3 Basic Settings 27
4 Monitoring the ambient air temperature 28
5 Maintenance and service 29
4
Installation OCTOPUS OS3
Release 01 02/2019
6Disassembly 30
6.1 Removing the device 30
7 Technical data 31
7.1 General data 31
7.2 Supply voltage 31
7.3 Signal contact 32
7.4 Power consumption/power output 32
7.5 Climatic conditions during operation 33
7.6 Climatic conditions during storage 33
7.7 Dimension drawings 34
7.8 EMC and immunity 35
7.9 Network range 38
8 Scope of delivery, order numbers and
accessories 39
8.1 Scope of delivery 39
8.2 Accessories 39
9 Underlying technical standards 40
A Further support 41
Installation OCTOPUS OS3
Release 01 02/2019
5
Safety instructions
General safety instructions
You operate this device with electricity. Improper usage of the device entails the risk of physical injury or significant property damage. The proper and safe operation of this device depends on proper handling during transportation, proper storage and installation, and careful operation and maintenance procedures. Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.The device is free of any service components. In case of a damaged
or malfunctioning device, turn off the supply voltage and return the device to Hirschmann for inspection.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 31.
Connect to the product only components suitable for the requirements
of the specific application case.
WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
6
Installation OCTOPUS OS3
Release 01 02/2019
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the prerequisite for grounding and labeling circuits, devices, and systems in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
Installation site requirements
Verify that there is at least 4 in (10 cm) of space above and below the
device.
Install this device solely in an operating site with restricted access, to
which maintenance staff have exclusive access. Install the device in such a way that it is protected against mechanical forces in the area of the power supply.
Device casing
Only technicians authorized by the manufacturer are permitted to open the casing. Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not touch the connection terminals.
Keep the cooling fins free to ensure good air circulation.The surfaces of the device housing may become hot. Avoid touching
the device while it is operating.
To preserve the suitability of your device for IP54, seal all unused
connections and ports with the provided plastic protection screws. See
“Scope of delivery” on page 39. See “Scope of delivery” on page 39 in
case of an additional demand. To preserve the IP54 suitability for your device, exclusively connect components with degree of protection IP54.
For operation according to EN 45545: Seal all unused connections
and ports exclusively with metal protection screws and metal screw caps. The use of plastic protection screws is prohibited. Protection screws and screw caps made of metal are available as an accessory.
See “Accessories” on page 39.
Installation OCTOPUS OS3
Release 01 02/2019
7
Grounding the device
Grounding the device is by means of a separate ground connection on the device.
Ground the device before connecting any other cables.Disconnect the grounding only after disconnecting all other cables.
The overall shield of a connected shielded twisted pair cable is connected to the grounding connector on the front panel as a conductor.
Requirements for connecting electrical wires
Before connecting the electrical wires, always verify that the requirements listed are complied with.
General requirements for connecting electrical wires The following requirements apply without restrictions:
The electrical wires are voltage-free.The cables used are permitted for the temperature range of the application case.Relevant for North America:
Exclusively use 60/75 °C (140/167 °F) or 75 °C (167 °F) copper (Cu) wire.
Requirements for connecting the signal contact The following requirements apply without restrictions:
The connected voltage complies with the requirements for a safety extra-low voltage
(SELV) or ES1 as per IEC/EN 62368-1.
The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
See “General data” on page 31.
Requirements for connecting the supply voltage The following requirements apply without restrictions: All of the following requirements are complied with:
The supply voltage corresponds to the voltage specified on the type plate of the device.The power supply conforms to overvoltage category I or II.The power supply has an easily accessible disconnecting device (for example a switch or
a plug). This disconnecting device is clearly identified. So in the case of an emergency, it is clear which disconnecting device belongs to which power supply cable.
The wire diameter of the power supply cable is at least 1 mm² (North America: AWG16) on
the supply voltage input.
The following requirements apply alternatively:
Relevant when the device is supplied via 1 voltage input: Relevant for North America:
The power supply complies with the requirements according to NEC Class 2.
8
Installation OCTOPUS OS3
Release 01 02/2019
CE marking
The labeled devices comply with the regulations contained in the following European directive(s):
2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
2014/30/EU (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility.
In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address:
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany www.hirschmann.com
The device can be used in the industrial sector.
Interference immunity: EN 61000-6-2Emitted interference: EN 55032Safety: EN 62368-1
You find more information on technical standards here:
See “Technical data” on page 31.
Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures.
Note: The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values.
Installation OCTOPUS OS3
Release 01 02/2019
9
FCC note:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation. Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations. These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment. The device creates and uses high frequencies and can also radiate these frequencies. If it is not installed and used in accordance with this operating manual, it can cause radio transmission interference. The use of this device in a residential area can also cause interference, and in this case the user is obliged to cover the costs of removing the interference.
Recycling note
After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country.
10
Installation OCTOPUS OS3
Release 01 02/2019
About this manual
The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device. The following manuals are available on the Internet at https://
www.doc.hirschmann.com/ as downloads:
User Manual InstallationUser Manual Basic ConfigurationUser Manual Redundancy ConfigurationReference Manual Graphical User InterfaceReference Manual Command Line Interface
Installation OCTOPUS OS3
Release 01 02/2019
11
Key
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
12
Installation OCTOPUS OS3
Release 01 02/2019
1 Description
1.1 General device description
The device is designed for the special requirements of industrial automation. The device meets the relevant industry standards, provides very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility.
The devices allow you to set up switched industrial Ethernet networks that conform to the IEEE 802.3 standard. The devices work without a fan.
The devices provide you with a large range of functions, which the manuals for the operating software inform you about. You find these manuals as PDF files on the Internet at: https://www.doc.hirschmann.com The Hirschmann network components help you ensure continuous communication across all levels of the company. The Network Management Software Industrial HiVision provides you with options for smooth configuration and monitoring. You find further information on the Internet at the Hirschmann product pages: http://
www.hirschmann.com/en/QR/INET-Industrial-HiVision
There are convenient options for managing the device. Manage your devices via:
Network management software (for example Industrial HiVision)Web browserV.24 interface (locally on the device)SSHTelnet
1.2 Device name and product code
The product code is made up of characteristics with defined positions. The characteristic values stand for specific product properties.
Item Characteristic Characteri
stic value
Description
1 ... 3 Product OCTOPUS
OS3
OCTOPUS 24GE-HV-Trainrouter
4 (hyphen) -
Table 1: Device name and product code
Installation OCTOPUS OS3
Release 01 02/2019
13
5 Data rate 4 10a/100/1000 Mbit/s 6 Hardware type 0 Standard 7 (hyphen) ­8 ... 9 Number:
PoE ports PoE(+) ports
00 0 ×
10 ... 11 Number:
10
a
/100 Mbit/s PoE/
PoE+ ports
00 0 × 10
a
/100 Mbit/s PoE/PoE+ ports
12 ... 13 Number:
10
a
/100/1000 Mbit/s
PoE/PoE+ ports
00 0 × 10
a
/100/1000 Mbit/s PoE/PoE+ ports
14 ... 15 Number:
10
a
/100 Mbit/s ports
00 0 × 10
a
/100 Mbit/s ports
16 ... 17 Number:
10
a
/100/1000 Mbit/s
ports
24 24 × 10
a
/100/1000 Mbit/s ports
18 ... 19 Number:
Ports >1000 Mbit/s
00 0 × 10000 Mbit/s ports
20 ... 21 First uplink port pair T6 Standard 22 ... 23 Second uplink port
pair
T6 Standard
24 (hyphen) ­25 Temperature range T Extended -40 °F ... +158 °F (-
40 °C ... +70 °C)
26 ... 27 Supply voltage N9 Rated voltage 72 V DC ... 110 V DC
Rated voltage range 50.4 V DC ... 138 V DC Connection type 5-pin M12 connector
28 ... 29 Certificates and
declarations
S9 Z9 + EN 50121-4 + EN 50155
30 ... 31 Software packages MR Unicast + Multicast Routing 32 ... 33 Customer-specific
version
HH Hirschmann standard
34 Hardware
configuration
S Standard
35 Software configuration E Entry (Hirschmann Standard) 36 ... 37 Software level 3A HiOS Layer 3 Advanced 38 ... 42 Software version 07.5. Software version 07.5.
XX.X Current software version 43 ... 44 Maintenance version XX Current maintenance version 45 ... 47 Place of manufacture -NT Manufactured in Germany
a. Exclusively for twisted pair connections.
Item Characteristic Characteri
stic value
Description
Table 1: Device name and product code