Hirschmann MM2-2FXM3/2TX1 Description And Operating Instructions

Page 1
Description and Operating Instructions Industrial ETHERNET Modular Industrial Communication Equipment
MICE Media modules
The Modular Industrial Communication Equipment, MICE, is a modular network
The media modules described in this instructions are the interface of the device to the LAN and can be plugged onto the fol­lowing basic modules of the MICE switch: – MS2108-2 (MICE 2000) – MS3124-4 (MICE 3000) – MS4128-5 (MICE 4000 / Power MICE) – MS20-… and MS30-…
The MB-2T expansion module allows you to add 2 slots to the MS20-1600, MS30-1602, MS3124-4, MS4128-5 MICE switch basic module for installing media modules.
MICE allows you to construct switched
Industrial ETHERNET networks that con-
form to the IEEE 802. and 802.3u standard using copper wires or optical fibers in a bus or ring topology.
In the – User manual „Installation“ – User manual „Basic configuration“ – User manual „Redundancy configuration“ – Reference manual „Web-based Interface“ – Reference manual „Command Line
Interface“ you will find a detailled description of the MICE and further information.
Hirschmann. Simply a good Connection.
MB-2T expansion module
MM2-2FXM3/2TX1
MM2-4TX1
MM4-4TX/SFP
MM2-2FLM4
MM2-2FXP4
MM3-4TX5
MM2-2FXM2
MM2-2FXS2
MM3-2AUI
MM3-2FXM4/2TX1
MM3-2FXS2/2TX1
MM3-2FXM2/2TX1
MM3-1FXM2/3TX1
MM3-1FXL2/3TX1 MM3-1FXS2/3TX1
MM2-4FXM3
MM3-4FXM2
MM3-4FXS2
MM3-4FXM4
MM3-4FLM4 MM3-4FXP4
Page 2
2
The performance features described here are binding only if they have been expressly guaranteed in the contract. We have checked that the contents of the technical publication agree with the hardware and software described. However, it is not possi­ble to rule out deviations completely, so we are unable to guarantee complete agree­ment. However, the details in the technical publication are checked regularly. Any cor­rections which prove necessary are contai­ned in subsequent editions. We are grateful for suggestions for improvement.
We reserve the right to make technical modifications.
Permission is not given for the circulation or reproduction of this document, its use or the passing on of its contents unless gran­ted expressly. Contravention renders the perpetrator liable for compensation for damages. All rights reserved, in particular in the case of patent grant or registration of a utility or design.
Copyright © Hirschmann Automation and Control GmbH 2007 All Rights Reserved
Safety instructions
Certified usage
Please observe the following:
z
Warning
The device may only be employed for the purposes described in the catalog and technical description, and only in conjunction with external devices and components recommen­ded or approved by Hirschmann. The product can only be operated correctly and safely if it is transpor­ted, stored, installed and assembled properly and correctly. Furthermore, it must be operated and serviced carefully.
Supply voltage
To be supplied by a NEC Class 2 power supply via MICE switch module. For Power over Ethernet modules: Connect a NEC Class 2 power supply only.
Use 60/75°C or 75°C copper (CU) wire only.
Shielding Ground
Note: The shielding ground of the connec-
table twisted pairs lines is connected to the front panel as a conductor.
Beware of possible short circuits when connecting a cable section with conductive shielding braiding.
Housing
z
Warning!
Only technicians authorized by Hirschmann are permitted to open the housing.
Make sure that the electrical installation meets local or nationally applicable safety regulations.
z
Warning!
Never insert pointed objects (thin screwdrivers, wires, etc.) into the inside of the subrack! This especial­ly applies to the area behind the socket connectors. Failure to ob­serve this point may result in inju­ries caused by electric shocks.
General Safety Instructions
Particular attention is to be paid to all warnings and items of information relating to safety.
z
Warning!
Any work that may have to be per­formed on the electrical installation should be performed by fully quali­fied technicians only.
z
Warning!
LED- or LASER components accor­ding to IEC 60825-1 (2003): CLASS 1 LASER PRODUCT. LIGHT EMITTING DIODE - CLASS 1 LED PRODUCT.
s
Warning! (POF media modules ...-P4-...) LED light
DO NOT STARE INTO THE BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS (e.g. lens, microsco­pe). Failure to observe this warning within a distance of 100 mm can endanger your eyes. Light is emitted from the optical connectors or from the ends of the optical fibers that are connected to them. Light Emitting Diode CLASS 2M Wave length 650 nm Power <2 mW According to IEC/CEI 60825-1:2003.
ESD guidelines
The media modules contain components highly sensitive to electrostatic fields.These components can be easily destroyed or have their lives shortened by an electrical field or by a discharge caused by touching the contacts. You can find more informationen about devices vulnerable to electrostatic fields in DIN EN 61340-5-1 (2001-08) and DIN EN 61340-5-2 (2002-01)
,
Recycling Note:
After its use, this product has to be processed as electronic scrap and disposed of according to the prevai­ling waste disposal regulations of your community / district / country / state.
1. MICE Hardware
1.1 SWITCH BASIC MODULES
The documentation enclosed to the switch basic module gives you a detailed descripti­on of the switch basic modules: – „User Manual Installation
Industrial ETHERNET Switch MICE MS20/MS30” for MS20-… and MS30-…
– „User Manual Installation
Industrial ETHERNET Switch Power MICE”
– “Description and Operating Instructions
Industrial ETHERNET Modular Industrial Communication Equipment MICE/Power MICE” for
– MS2108-2 (MICE 2000) – MS3124-4 (MICE 3000)
1.2 MEDIA MODULES
– MICE 2000: See Table 1. – MICE 3000: See Table 2. – MICE 4000: See Table 3. – MICE media modules open variant:
See Table 4.
1.3 MB-2T EXPANSION MODULE
The MB-2T expansion module allows you to add 2 slots to the MS20-1600, MS30-1602, MS3124-4, MS4128-5 MICE switch basic module for installing media modules.
1.4 SFP MODULES
SFP modules are optical transceivers (Fast ETHERNET and Gigabit ETHERNET SFP modules see chapter 7 Technical Data). The SFP modules are plugged into the SFP slots of the Fast ETHERNET media module MM3-4SFP (MM20-Z6Z6Z6Z6) or of the Gigabit ETHERNET media modules MM4-4TX/SFP / MM4-2TX/SFP to provide a F/O port.
The MM3-4SFP (MM20-Z6Z6Z6Z6) has four slots for SFP modules (100 Mbit/s).
The MM4-4TX/SFP / MM4-2TX/SFP has four/two TP interfaces and four/two slots for SFP modules (100/1000 Mbit/s). Inserting the SFP module deactivates the correspon­ding TP interface.
1.5 MM22-T1T1T1T1 POE MEDIA MODULE
The MM22-T1T1T1T1 PoE media module (deeper module style) supports Power over ETHERNET (PoE) in compliance with IEEE
802.3af. It enables the connection and the remote supply of e.g. IP telephones (voice over IP), webcams, sensors, print servers and WLAN access points via 10BASE­T/100BASE-TX. With PoE, the power supply of these data terminal equipments is served via the twisted pair cable.
The MM22-T1T1T1T1 media module offers four 10BASE-T/100BASE-TX ports (RJ45 connectors) for connecting network seg­ments or PoE data terminal equipments (PD, Powered Device) up to class 0 (respec­tively class 3) maximum.
The current is supplied on the idle wire pairs (spare pairs); the ports are not electri­cally isolated against each other. In compliance with IEEE 802.3af, each port has the attributes: – Endpoint PSE – Alternative B.
2. Functional description
The ports of a MICE represent a terminal connection for the connected LAN segment. You can connect single devices or complete network segments.
2.1 INTERFACES
TP/TX/FL/FX terminal devices or other TP/TX/FL/FX segments can be connected to the 10/100/1000 Mbit/s ports of the media modules.
The MICE and MS20 supports both ETHER­NET 10 Mbit/s and Fast ETHERNET 100 Mbit/s, the Power MICE and MS30 supports additionally Gigabit ETHERNET 1000 Mbit/s.
The TP/TX ports support autocrossing, autonegotiation and autopolarity.
2.2 DIP SWITCH (MM3-AUI)
With the 3-pin DIP switch on the MM3-2AUI module – you can switch on or off the SQE test fun-
ction at port 1 with the SQE-Test Port 1 switch.
Page 3
3
State of delivery: switch in position 0 (Off), i.e. SQE test function not active. – you can switch on or off the SQE test fun-
ction at port 2 with the SQE-Test Port 2 switch. State of delivery: switch in position 0 (Off), i.e. SQE test function not active.
– you can switch on or off the monitoring
of the DTE voltage, for both ports together, with the DTEPower-Monitor switch.
– ON: monitoring of the DTE voltage
active, data transmission only possible if DTE voltage available.
– OFF: no monitoring of the DTE voltage,
data transmission always possible.
– State of delivery: switch in position 0
(OFF), i.e. no monitoring of DTE voltage.
3. Assembly, startup procedure and dismantling
3.1 UNPACKING, CHECKING
Check whether the package was deliver-
ed completely (see scope of delivery).
Check the individual parts for transport
damage.
z
Warning!
Use only undamaged parts!
3.2 ASSEMBLING MEDIA MODULES
Media modules can be assembled and disassembled during running operation.
To fasten a media module, first remove
the protective cap over the plug of the MICE.
Plug the media module onto the plug. Tighten the 4 screws on the corners of
the media module.
Check whether the switch pre-setting
suits your requirements.
Fit the signal lines.
3.3 ASSEMBLING SFP MODULES
To fasten a SFP module, first remove
the protective cap over the socket.
Insert the SFP module with the closed
lock into the socket until you hear it snap in.
Note: Use only Hirschmann SFP modules.
3.4 ASSEMBLING THE MB-2T EXPANSION MODULE
The MB-2T expansion module can be installed while in running operation. On the right side of the switch basic
module, loosen the screw at the top and at the bottom (1-3 revolutions).
Remove the side cover.If you have not yet done so, mount the
switch basic module onto the top-hat rail.
Slide the MB-2T expansion module on
the top-hat rail toward the switch basic module until the modules plug into each other.
On the switch basic module, tighten the
screws at the top and at the bottom.
3.5 STARTUP PROCEDURE
You start up the MICE by connecting the supply voltage via the terminal block(s) on the MICE basic module. Lock the terminal block(s).
3.6 CONNECTING THE MM22-T1T1T1T1 POE MEDIA MODULE
The MM22-T1T1T1T1 PoE media module is supplied with the PoE voltage (48 V DC safety extra-low voltage) via an external power supply unit. The PoE voltage is fed into the 3-pin terminal block of the PoE media module. The twisted pair cables are supplied with the PoE voltage on port 1 to 4 via the spare pairs (pins 4&5 and 7&8 of the RJ45 sockets).
Note: Only use the Hirschmann RPS60/48V EEC power supply unit for provi­ding the PoE voltage.
Make sure that the external power
supply unit being used for providing the PoE voltage meets, among other things, the following requirements: – Isolation requirements in compliance
with IEEE 802.3af (electrical strength of the 48V output to “rest of the
world" 2250 V DC for 1 min.) – Output power < 100 W. – Current limiting < 2 A. – Power supply unit and PoE media
module form a "Limited Power Sour-
ce" in compliance with IEC60950-1. – The external PoE power supply unit
has to be able to provide the power
for the PDs being connected.
All these conditions are met by the RPS60/48V EEC power supply unit.
Connect the PoE voltage to the 3-pin
terminal block (included in the scope of delivery), as shown in the following figure. Make sure that your installation com­plies with the following conditions: – Length of the supply line < 3 m. – Cross-section of the supply lines is
dimensioned for 1.5 A
Fig. 1: 3-pin terminal block of the PoE media module
Mount the terminal block for the PoE
supply voltage on the bottom side of the PoE module via snap lock. Push it until it locks into position.
Note: Use 4-pair twisted pair cables for connecting the data terminal equipments. Only connect data terminal equipments which are conform to IEEE 802.3af.
4. Further support
In the event of technical queries, please talk to the Hirschmann contract partner respon­sible for looking after your account or directly to the Hirschmann office. You can find the addresses of our contract partners – on the Internet
(http://www.hirschmann-ac.de)
Our support line is also at your disposal: Tel. +49(1805) 14-1538 Fax +49(7127) 14-1551
Answers to Frequently Asked Questions can be found on the Hirschmann product inter­net sites on www.hirschmann-ac.de The FAQs are located under „Service“ in the Automation and Control section. www.hicomcenter.com gives you an up-to-date overview of training courses about technology and products.
5. Technical data
Dimensions W x H x D 38 mm x 110 mm x 79 mm (MM2-...)
38 mm x 110 mm x 119 mm (MM3-..., MM4-...) 38 mm x 110 mm x 79 or 119 mm (MM20-..., MM21-..., MM22-..., MM30-...)
Humidity 10% to 95% (non condensing) Atmospheric pressure up to 2000 m (795 hPa, higher altitudes on demand) Pollution degree 2 Laser protection Class 1 conforming to EN 60825
Class 2M conforming to EN 60825-1:2003-10 (POF media modules ...-P4-...)
Protection type IP 20 EMV interference proof A
1)
B
1)
H
1)
EN 61000-4-2, Discharge of static electricity Contact discharge: test level 3 4 kV 8 kV 8 KV
Air discharge: test level 3 8 kV 15 kV 15 kV EN 61000-4-3, Electromagnetic fields Test level 3 (80 - 2000 MHz) 10 V/m 20 V/m 20 V/m EN 61000-4-4, Fast transients (burst), - Power line 2 kV 4 kV 4 kV
Test level 3, x - Data line 1 kV 4 kV 4 kV
EN 61000-4-5 Surge voltage - Power line, line/line: test level 2 0,5 kV 1 kV 1 kV
- Power line, line/earth: test level 3 1 kV 2 kV 2 kV
- Data line: test level 3 1 kV 4 kV 4 kV
48 V
+-
Page 4
4
EN 61000-4-6 Cable-based RF faults, 10 kHz - 150 kHz 3 V 3 V 3 V
Test level 3 150 kHz - 80 MHz 10 V 10 V 10 V
EN 61000-4-9
Impulse shaped magnetic fields
Test level 4 - 300 A/m 300 A/m
EMV emitted immunity A
1)
B
1)
H
1)
EN 55022 Class A Yes Yes Yes FCC 47 CFR Part 15 Class A Yes Yes Yes German Lloyd Rules for Classifikation and Construction VI-7-3 - Yes Yes
Part 1 Ed. 2001
Stability Vibration IEC 60068-2-6 Test FC, test level in line with IEC 61131-2V Yes Yes Yes
German Lloyd Guidelines for the Performance - Yes Yes
of Type Tests Part 1
IEC 870-2-2 Table 3 Normal Installation in line with EN 61850-3 - Yes Yes
Shock IEC 60068-2-27 Test Ea, test level in line with IEC 61131-2 Yes Yes Yes
IEC 870-2-2 Table 3 Normal Installation in line with EN 61850-3 - Yes Yes
1)
Product code A: Certification = CE, UL Product code B: Certification = CE, UL, GL, Railway (along track), Substation, ATEX Product code H: Certification = CE, UL, GL, Railway (along track), Substation The media modules in Table 1 to 3 (see page 5) have the certification “A”.
Network size
AUI port
Length of a AUI cable 50 m max.
TP/TX port 10/100/1000BASE-T/TX
Length of a twisted pair segment 100 m (328 ft) max. (cat5e cable with 1000BASE-T)
F/O port 10BASE-FL
Product code Wave length Fiber System attenuation Expansion Fiber data
-M4 MM 850 nm 50/125 µm 0-9.5 dB 0-2,000 m 3.0 dB/km; 400 MHz*km
-M4 MM 850 nm 62.5/125 µm 0-12.5 dB 0-3,000 m 3.2 dB/km; 200 MHz*km
F/O port 100BASE-FX
Product code Wave length Fiber System attenuation Expansion Fiber data
-M2, -M4 MM 1300 nm 50/125 µm 0-8 dB 0-5 km 1.0 dB/km; 800 MHz*km
-M2, -M4 MM 1300 nm 62.5/125 µm 0-11 dB 0-4 km 1.0 dB/km; 500 MHz*km
-S2 SM 1300 nm 9/125 µm 0-16 dB 0-30 km 0.4 dB/km; 3.5 ps/(nm*km)
-L2 LH 1550 nm 9/125 µm 7-29 dB 24-86 km 0.3 dB/km; 19 ps/(nm*km)
-P4 MM POF 650 nm 980/1000 µm 0-15.5 dB 0-65 m 200 dB/km; 10 MHz*km
-P4 MM HCS 650 nm 200/230 µm 0-7.0 dB 0-140 m 10 dB/km; 17 MHz*km
-G2 LH+ 1550 nm 9/125 µm 14-47 dB 67-176 km 0.25 dB/km; 19 ps/(nm*km)
F/O port 100BASE-FX (SFP Fiberoptic Fast ETHERNET Transceiver)
Product code Wave length Fiber System attenuation Expansion Fiber data M-FAST-SFP-...
-MM/LC (EEC) MM 1310 nm 50/125 µm 0-11 dB 0-5 km 1.0 dB/km; 800 MHz*km
-MM/LC (EEC) MM 1310 nm 62.5/125 µm 0-8 dB 0-4 km 1.0 dB/km; 500 MHz*km
-SM/LC (EEC) SM 1310 nm 9/125 µm 0-13 dB 0-25 km 0.4 dB/km; 3.5 ps/(nm*km)
-SM+/LC (EEC) SM 1310 nm 9/125 µm 10-29 dB 25-65 km 0.4 dB/km; 3.5 ps/(nm*km)
-LH/LC SM 1550 nm 9/125 µm 10-29 dB 40-104 km 0.25 dB/km; 19 ps/(nm*km)
F/O port 1000BASE-FX (SFP Fiberoptic Gigabit ETHERNET Transceiver)
Product code Wave length Fiber System attenuation Expansion Fiber data M-SFP-...
-SX/LC (EEC) MM 850 nm 50/125 µm 0-7.5 dB 0-550 m 3.0 dB/km; 400 MHz*km
-LX/LC (EEC) SM 1310 nm
1)
50/125 µm 0-11 dB 0-550 m 1.0 dB/km; 800 MHz*km
-SX/LC (EEC) MM 850 nm 62.5/125 µm 0-7.5 dB 0-275 m 3.2 dB/km; 200 MHz*km
-LX/LC (EEC) SM 1310 nm
1)
62.5/125 µm 0-11 dB 0-550 m 1.0 dB/km; 500 MHz*km
-LX/LC (EEC) SM 1310 nm 9/125 µm 0-11 dB 0-20 km 0.4 dB/km; 3.5 ps/(nm*km)
-LH/LC (EEC) LH 1550 nm 9/125 µm 6-22 dB 24-72 km 0.25 dB/km; 19 ps/(nm*km)
-LH+/LC LH 1550 nm 9/125 µm 15-32 dB 60-120 km 0.25 dB/km; 19 ps/(nm*km)
MM = multimode, SM = singlemode, LH = singlemode longhaul
1)
with F/O adapter in line with IEEE802.3-2002 clause 38 (single-mode fiber offset-launch mode conditioning patch cord)
Displays
Device status 1 x green LED P – Power, internal supply voltage present Port status 4 x green/yellow LED 1 to 4 – The meaning depends on the setting of the display status.
Controls (MM3-2AUI)
3-pole DIP switch 1
SSQQEE--TTeesstt PPoorrtt 11
– ON = SQE test function on port 1 enabled
2
SSQQEE--TTeesstt PPoorrtt 22
– ON = SQE test function on port 2 enabled
3
DDTTEEPPoowweerr--MMoonniittoorr
– ON = Monitoring of the DTE voltage active
Scope of delivery
MICE media module incl. Labels, description and operating instructions
Page 5
5
MICE 3000 media modules
Module type AUI port TP ports F/O port F/O port F/O port F/O port F/O port Supported since
10/100 multimode multimode multimode singlemode singlemode MICE SW release
10 Mbit/s POF 100 Mbit/s 1300 nm, 1550 nm,
PowerMS20
100 Mbit/s 100 Mbit/s 100 Mbit/s MICE
MICE MS30 MM3-2AUI 2, Sub-D-St. – 4.0 1.0 1.0 MM3-4TX5 – 4, M12 4.0 1.0 1.0 MM3-4TX1-RT
1)
– 4, RJ45 – – – – – 5.0 2.0 1.0
MM3-2FLM4/2TX1-RT
1)
– 2, RJ45 2, ST – – – – 5.0 2.0 1.0 MM3-4FLM4 4, ST 2.0 1.0 1.0 MM3-4FXP4 – – – 4, ST 4.0 1.0 1.0 MM3-1FXM2/3TX1 3, RJ45 1, DSC 3.1 1.0 1.0 MM3-2FXM2/2TX1(-EEC) – 2, RJ45 – – 2, DSC – – 2.0 1.0 1.0 MM3-2FXM2/2TX1-RT
1)
– 2, RJ45 – – 2, DSC – – 5.0 2.0 1.0 MM3-2FXM4/2TX1 2, RJ45 2, ST 3.1 1.0 1.0 MM3-4FXM2 – – – – 4, DSC – – 2.0 1.0 1.0 MM3-4FXM4 – – – – 4, ST – – 3.1 1.0 1.0 MM3-1FXS2/3TX1(-EEC) – 3, RJ45 – – – 1, DSC – 3.1 1.0 1.0 MM3-2FXS2/2TX1 – 2, RJ45 – – – 2, DSC – 2.0 1.0 1.0 MM3-2FXS2/2TX1-RT
1)
– 2, RJ45 – – – 2, DSC – 5.0 2.0 1.0 MM3-4FXS2 – – – – – 4, DSC 3.1 1.0 1.0 MM3-1FXL2/3TX1 – 3, RJ45 – – – – 1, DSC 2.0 1.0 1.0
Table 2: Number of media connectors each MICE 3000 media module, kind of connector and necessary software
1)
Realtime modules, in line with IEEE 1588 PTP (Precision Time Protocol)
MICE 2000 media modules
Module type AUI port TP ports F/O port F/O port F/O port F/O port F/O port Supported since
10/100 multimode multimode multimode singlemode singlemode MICE SW release
10 Mbit/s POF 100 Mbit/s 1300 nm, 1550 nm,
PowerMS20
100 Mbit/s 100 Mbit/s 100 Mbit/s MICE
MICE MS30 MM2-4TX1(-EEC) – 4, RJ45 1.0 1.0 1.0 MM2-2FLM4 2, ST 1.0 1.0 1.0 MM2-2FXP4 – – – 2, ST – – – 4.0 1.0 1.0 MM2-4FXM3 – – – – 4, MTRJ – – 1.0 1.0 1.0 MM2-2FXM3/2TX1 2, RJ45 2, MTRJ 1.0 1.0 1.0 MM2-2FXM2 – – – – 2, DSC – – 1.0 1.0 1.0 MM2-2FXS2 – – – – – 2, DSC – 2.0 1.0 1.0
Table 1: Number of media connectors each MICE 2000 media module, kind of connector and necessary software
6. MICE media modules
6.1 PORT ASSIGNMENT (EXAMPLES)
6.2 NUMBER AND KIND OF MEDIA CONNECTORS
Accessories
Pocket Guide 280 720-851
AutoConfigurationAdapter ACA 11 943 751-001
Terminal access cable 943 301-001 6-pin terminal block (50 pieces) 943 845-002 Rail Power Supply RPS 30 943 662-003 Rail Power Supply RPS 80 EEC 943 662-080 Rail Power Supply RPS 120 EEC 943 662-120
Rail Power Supply RPS60/48V EEC 943 952-001 Network Management Software HiVision 943 471-100
1
3
2
4
MM4-4TX/SFPMM3-4FLM4MM2-4FXM3 MM3-4SFP (MM20-Z6Z6Z6Z6)
1 2 3 4
1
2
3
4
1
2
3
4
1* 2*
3* 4*
Port 1 to 4 (SFP ports) alterna-
tively to port 1* to 4* (TP ports)
Z6Z6 Z6
20-Z6
MM
1
2
3
4
Page 6
6
7. General data
Power Power Operating temp. Storage Order consumption output surrounding air temperature number
MICE 2000 media modules: MM2-4TX1 0.8 W 2.8 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 722-101 MM2-4TX1-EEC 0.8 W 2.8 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 722-151 MM2-2FXP4 3.8 W 13.0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 842-101 MM2-4FXM3 6.8 W 23.2 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 721-101 MM2-2FXM3 / 2TX1 3.8 W 13.0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 720-101 MM2-2FXM2 3.8 W 13.0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 718-101 MM2-2FXS2 3.8 W 13.0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 719-101
MICE 3000 media modules: MM3-2AUI 3.4 W 11.6 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 840-101 MM3-4FLM4 5.0 W 17.1 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 760-101 MM3-2FLM4 / 2TX1-RT 5.0 W 17.1 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 117-004 MM3-4TX5 0.8 W 2.8 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 841-101 MM3-4TX1-RT 0.8 W 2.8 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 117-001 MM3-4FXP4 6.8 W 23.2 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 843-101 MM3-1FXM2 / 3TX1 2.3 W 7.9 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 839-101 MM3-1FXM2 / 3TX1-EEC 2.3 W 7.9 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 839-151 MM3-2FXM2 / 2TX1 3.8 W 13.0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 761-101 MM3-2FXM2 / 2TX1-EEC 3.8 W 13.0 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 761-151 MM3-2FXM2 / 2TX1-RT 3.8 W 13.0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 117-002
MICE 4000 media modules
Module type TP ports SFP ports Supported since
10/100/1000 alternativ zu TP-Ports/ MICE SW release
alternatively to TP ports
Power MS20
MICE
MICE MS30 MM4-2TX/SFP 2, RJ45 2 2.0 1.0 MM4-4TX/SFP 4, RJ45 4 1.0 1.0
Table 3: Number of media connectors each MICE 4000 media module, kind of connector and necessary software
Open variant media modules
Module type TP ports SFP ports Supported since
10/100/1000 alternativ zu TP-Ports/ MICE SW release
alternatively to TP ports
Power MS20
MICE
MICE MS30 MM20..., MM21..., MM30...
0 to 4 ports (media and connector at your option, see chapter 8 “Open Variant”) 2.0 MM22-T1T1T1T1 4 ports (twisted pair, RJ45 connector) 3.0 3.0 MM20-Z6Z6Z6Z6
4 ports (fiber optic, SFP slot, 100 Mbit/s) 4.0 4.0
Table 4: MICE open variant media module, necessary software
6.3 PIN ASSIGNMENT OF THE INTERFACES
10/100 Mbit/s twisted pair connection
Fig. 3: Pin assignment of a TP/TX interface in MDI-X mode, RJ45 socket
Fig. 4: Pin assignment of a TP/TX interface, M12 socket
10/100 Mbit/s twisted pair connection PoE (Power over Ethernet) at MM22-T1T1T1T1 PoE media module
Fig. 5: Pin assignment of a TP/TX interface with PoE, for supply via the the idle wire pairs (spare pairs), RJ45 socket
3-pin terminal block (PoE module)
Fig. 6: 3-pin terminal block of the PoE media module
10/100/1000 Mbit/s twisted pair connection
Fig. 7: Pin assignment of the 1000 Mbit/s twisted pair interface
AUI connection
Fig. 8: Pin assignment of the AUI interface
V
n.c. Pin 8 n.c. Pin 7 TD- Pin 6 n.c. Pin 5 n.c. Pin 4
Pin 3TD+ Pin 2RD­Pin 1RD+
12
RD+TD+
RD-
43
TD-
V- Pin 8 V- Pin 7 TD- Pin 6 V+ Pin 5 V+ Pin 4
Pin 3TD+ Pin 2RD­Pin 1RD+
BI_DC-
Pin 8
BI_DC+
Pin 7
BI_DA-
Pin 6
BI_DD-
Pin 5 Pin 4
BI_DD+ BI_DA+
Pin 3
BI_DB-
Pin 2
BI_DB+
Pin 1
48 V
+-
shielding CO
output DI-A
shielding DI
input DO-A
output CI-A
shielding CI
n.c.
GND
Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1
Pin 15 Pin 14 Pin 13 Pin 12 Pin 11 Pin 10 Pin 9
n.c. shielding 12 voltage 12 V output DI-B shielding DO input DO-B output CI-B
Page 7
7
8. Open variant product code
Alternatively to the order number (ref. table in chapter 7, last column) you can use the product code. It offers you, tailored to your requirements, an additional variety of media module types.
The product code of your media module is made from combining the desired product characteristics in accordance with the follo­wing table. The short designation is in column “Ident.”.
Example: Product code MM30-O7O7O7O7SA = media module 1000 Mbit/s with four combo ports gigabit Ethernet (four SFP ports or alternatively four TP ports RJ45). This example equals the module MM4-4TX/SFP with the order number 943 010-001.
MM3-2FXM4 / 2TX1 3.8 W 13.0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 837-101 MM3-4FXM2 6.8 W 23.2 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 764-101 MM3-4FXM4 6.8 W 23.2 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 835-101 MM3-1FXS2 / 3TX1 2.3 W 7.9 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 838-101 MM3-1FXS2 / 3TX1 EEC 2.3 W 7.9 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 838-151 MM3-2FXS2 / 2TX1 3.8 W 13.0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 762-101 MM3-2FXS2 / 2TX1-EEC 3.8 W 13.0 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 762-151 MM3-2FXS2 / 2TX1-RT 3.8 W 13.0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 117-003 MM3-4FXS2 6.8 W 23.2 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 836-101 MM3-1FXL2 / 3TX1 3.4 W 11.6 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 763-101 MM3-4SFP 8.0 W 27.3 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 938-001
MICE 4000 media modules: MM4-4TX / SFP 9.0 W 30.8 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 010-001 MM4-2TX / SFP 5.8 W 19.8 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 622-001
Open variant media modules (You will find further informationen on www.hirschmann-ac.com): MM20-... 4 TX-/0 FX-Ports 0.8 W 2.8 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM20-... 3 TX-/1 FX-Ports 2.3 W 7.9 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM20-... 2 TX-/2 FX-Ports 3.8 W 13.0 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM20-... 0 TX-/2 FX-Ports 3.8 W 13.0 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM20-... 1 TX-/3 FX-Ports 5.3 W 18.1 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM20-... 0 TX-/4 FX-Ports 6.8 W 23.2 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM20-A8A89999 3.4 W 11.6 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM20-F4F4F4F4 5.0 W 17.1 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM20-Z6Z6Z6Z6 8.0 W 27.3 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM30-O7O7O7O7 9.0 W 30.8 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM30-O7O79999 5.8 W 19.8 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM21-T1T1T1T1 0.8 W 2.8 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM21-F4F4T1T1 5.0 W 17.1 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM21-M2M2T1T1 3.8 W 13.0 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM21-S2S2T1T1 3.8 W 13.0 Btu (IT)/h see chapter 8 see chapter 8 product code; chap. 8 MM22-T1T1T1T1 0.8 W 2.8 Btu (IT)/h see chapter 8 see chapter 8 product code, chap. 8
Expansion moduel MB-2T 0 W 0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 733-002
Fast ETHERNET SFP modules: M-FAST SFP-MM / LC 0 W 0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 865-001 M-FAST SFP-MM / LC EEC 0 W 0 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 945-001 M-FAST SFP-SM / LC 0 W 0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 866-001 M-FAST SFP-SM / LC EEC 0 W 0 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 946-001 M-FAST SFP-SM+ / LC 0 W 0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 867-001 M-FAST SFP-SM+ / LC EEC 0 W 0 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 947-001 M-FAST SFP-LH / LC 0 W 0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 868-001
Gigabit ETHERNET SFP modules: M-SFP-SX / LC 0 W 0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 014-001 M-SFP-SX / LC EEC 0 W 0 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 896-001 M-SFP-LX / LC 0 W 0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 015-001 M-SFP-LX / LC EEC 0 W 0 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 897-001 M-SFP-LH / LC 0 W 0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 042-001 M-SFP-LH / LC EEC 0 W 0 Btu (IT)/h -40 °C … +70 °C -40 °C … +85 °C 943 898-001 M-SFP-LH+ / LC 0 W 0 Btu (IT)/h 0 °C … +60 °C -40 °C … +70 °C 943 049-001
Page 8
Hirschmann Automation and Control GmbH Stuttgarter Straße 45-51 D-72654 Neckartenzlingen Germany Tel.: +49-1805-14-1538 Fax: +49-7127-14-1551 E-Mail: hac-support@hirschmann.de Internet: http://www.hirschmann-ac.com
Printed in Germany Subject to alterations
Position Attribute Ident. Feature 1 to 4 Product MM20 Media module 10/100 Mbit/s (standard)
MM21 Media module 10/100 Mbit/s (realtime) MM22 Media module 10/100 Mbit/s (Power over Ethernet) MM30 Media module 1000 Mbit/s (standard)
5 - (hyphen)
6 and 7 1st port (media/connector) T1 Twisted pair (TX) / RJ45
T5 Twisted pair (TX) / M12 M2 Multimode FX DSC (only 100 Mbit/s) M3 Multimode FX MTRJ (only 100 Mbit/s) M4 Multimode FX ST (only 100 Mbit/s) S2 Singlemode FX DSC (only 100 Mbit/s) S4 Singlemode FX ST (only 100 Mbit/s) L2 Singlemode longhaul FX DSC (only 100 Mbit/s) G2 Singlemode longhaul FX DSC 200km (only 100 Mbit/s) F4 Multimode FL ST (only 10 Mbit/s) P4 POF FX ST (only 100 Mbit/s) O7 Combo port gigabit Ethernet (SFP only 1000 Mbit/s) A8 AUI Sub-D Z6 Fiber optic / SFP slot (100 Mbit/s)
8 and 9 2nd port (media/connector) ... See position 6 and 7
10 and 11 3rd port (media/connector) ... See position 6 and 7
99 Empty
12 and 13 4th port (media/connector) ... See position 6 and 7
99 Empty
14 Temperature range S Standard 0 °C to +60 °C
T Extended -40 °C to +70 °C E Extended -40 °C to +70 °C & Conformal Coating
15 Specifications A CE, UL 508, ISA 12.12.01 (UL 1604)
H A plus GL, IEC 61850, IEEE 1613 substation, EN 50121-4 railway (along track) B H plus ATEX100a
Loading...