Hirschmann MACH104-16TX-PoEP-E-L2P, MACH104-16TX-PoEP-R-L2P, MACH104-16TX-PoEP-L2P, MACH104-16TX-PoEP+2X-L2P, MACH104-16TX-PoEP+2X-R-L2P User Manual

...
Page 1
Installation MACH104
Release 08 01/2019
Technical support
https://hirschmann-support.belden.com
Installation Industrial Ethernet Workgroup Switch
MACH104 Full Gigabit Family
MACH104-20TX-F-4PoE...
MACH104-20TX-F...
MACH104-20TX-FR...
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-F
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-FR
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-F-4PoE
P
Page 2
2019-01-21
Installation MACH104
Release 08 01/2019
The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone.
© 2019 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is not permitted, either in whole or in part. An exception is the preparation of a backup copy of the software for your own use.
The performance features described here are binding only if they have been expressly agreed when the contract was made. This document was produced by Hirschmann Automation and Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right to change the contents of this document without prior notice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network components or the associated operating software. In addition, we refer to the conditions of use specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com).
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany
Page 3
Installation MACH104
Release 08 01/2019
3
Contents
Safety instructions 5
About this manual 13
Legend 14
1 Description 15
1.1 General device description 15
1.2 Description of the device variants 16
1.2.1 MACH104-20TX-F...: Devices with 24 GB ports 16
1.2.2 MACH104-20TX-FR...: Devices with 24 GB ports and redundant power supply 17
1.2.3 MACH104-20TX-F-4-PoE...: Devices with 24 GB ports, 4 of them PoE ports 18
1.3 Supply voltage 19
1.3.1 MACH104-20TX-F... 19
1.3.2 MACH104-20TX-FR... 19
1.3.3 MACH104-20TX-F-4-PoE... 20
1.4 Ethernet ports 20
1.4.1 10/100/1000 Mbit/s twisted pair port 20
1.4.2 100 Mbit/s F/O port 21
1.4.3 1000 Mbit/s F/O port 21
1.4.4 PoE ports 21
1.4.5 Combo ports 22
1.5 Display elements 22
1.5.1 Device state 23
1.5.2 Port status 24
1.6 Management interfaces 25
1.6.1 V.24 interface (external management) 25
1.6.2 USB interface 26
1.7 Signal contact 26
2 Installation 27
2.1 Checking the package contents 27
2.2 Installing an SFP transceiver (optional) 27
Page 4
4
Installation MACH104
Release 08 01/2019
2.3 Wiring and installing the signal contact 28
2.4 Installing the device and grounding 29
2.4.1 Selecting the assembly location 29
2.4.2 Mounting on a flat surface 29
2.4.3 Mounting in a switch cabinet 29
2.4.4 Mounting on the wall 30
2.4.5 Grounding the device 31
2.5 Operating the device 32
2.6 Connecting data cables 32
3 Making basic settings 33
3.1 Default settings 34
4 Maintenance and service 35
5 Deinstallation 36
5.1 Removing the device 36
5.2 Removing an SFP transceiver (optional) 36
6 Technical data 37
6.1 General technical data 37
6.2 Dimension drawings 38
6.3 EMC and immunity 38
6.4 Network range 40
6.5 Power consumption/power output 43
7 Scope of delivery, order numbers and
accessories 44
8 Underlying technical standards 47
A Further support 48
Page 5
Installation MACH104
Release 08 01/2019
5
Safety instructions
General safety instructions
You operate this device with electricity. Improper usage of the device entails the risk of physical injury or significant property damage. The proper and safe operation of this device depends on proper handling during transportation, proper storage and installation, and careful operation and maintenance procedures. Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.The device is free of any service components. In case of a damaged
or malfunctioning device, turn off the supply voltage and return the device to Hirschmann for inspection.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the prerequisite for grounding and labeling circuits, devices, and systems in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Page 6
6
Installation MACH104
Release 08 01/2019
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 37.
Connect to the product only components suitable for the requirements
of the specific application case.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
Grounding the device
The device is grounded via the power supply connections.
Requirements for connecting electrical wires
Before connecting the electrical wires, always verify that the requirements listed are complied with.
Requirements for connecting the supply voltage
Before connecting the supply voltage, always verify that the requirements listed are complied with.
The following requirements apply without restrictions:
The electrical wires are voltage-free.The cables used are permitted for the temperature range of the application case.Only switch on the device when the casing is closed.Relevant for North America:
Exclusively use 60/75 °C (140/167 °F) or 75 °C (167 °F) copper (Cu) wire.
Prerequisites: All of the following requirements are complied with:
The supply voltage corresponds to the voltage specified on the type plate of the device.The power supply conforms to overvoltage category I or II.The power supply has an easily accessible disconnecting device (for example a switch or
a plug). This disconnecting device is clearly identified. So in the case of an emergency, it is clear which disconnecting device belongs to which power supply cable.
This applies to the following device variants only:
MACH104-20TX-FR...
Unplug every non-heating device coupling to disconnect the device from the power supply.
This applies to the following device variants only:
MACH104-20TX-FR...
The wire diameter of the power supply cable is at least 1 mm² (North America: AWG16) on the supply voltage input.
The cross-section of the ground conductor is the same size as or bigger than the cross-
section of the power supply cables.
The power supply cable is suitable for the voltage, the current and the physical load.
Hirschmann recommends a wire diameter of 0.5 mm² to 0.75 mm² (AWG20 up to AWG18).
The following requirements apply alternatively:
Page 7
Installation MACH104
Release 08 01/2019
7
Relevant when the device is supplied via 1 voltage input: Alternative 1 The power supply complies with the requirements for a limited power source
(LPS) as per EN 60950-1.
Alternative 2 Relevant for North America:
The power supply complies with the requirements according to NEC Class 2.
Alternative 3 All of the following requirements are complied with:
The power supply complies with the requirements for a safety extra-low
voltage (SELV) as per IEC/EN 60950-1.
Supply with DC voltage:
A fuse suitable for DC voltage is located in the plus conductor of the power supply. The minus conductor is on ground potential. Otherwise, a fuse is also located in the minus conductor. Regarding the properties of this fuse:
See “Technical data” on page 37.
Supply with AC voltage:
A fuse is located in the outer conductor of the power supply. The neutral conductor is on ground potential at both voltage inputs. Otherwise, a fuse is also located in the neutral conductor. Regarding the properties of this fuse:
See “Technical data” on page 37.
Relevant when the device is supplied via 2 voltage inputs: Alternative 1 The total voltage supply meets the requirements for a limited power source
(LPS) as per EN 60950-1.
Alternative 2 Relevant for North America:
The total voltage supply complies with the requirements as per NEC Class 2.
Alternative 3 All of the following requirements are complied with:
The power supply complies with the requirements for a safety extra-low
voltage (SELV) as per IEC/EN 60950-1.
Supply with DC voltage:
A fuse suitable for DC voltage is located at both voltage inputs in the plus
conductor of the power supply.
The minus conductor is on ground potential at both voltage inputs.
Otherwise, a fuse is also located in the minus conductor.
Regarding the properties of this fuse:
See “Technical data” on page 37.
Supply with AC voltage:
A fuse is located at both voltage inputs in the outer conductor of the power
supply.
The neutral conductor is on ground potential at both voltage inputs.
Otherwise, a fuse is also located in the neutral conductor.
Regarding the properties of this fuse:
See “Technical data” on page 37.
Prerequisites:
Page 8
8
Installation MACH104
Release 08 01/2019
Supply voltage
The supply voltage is connected to the device casing through protective elements exclusively. The supply voltage is electrically isolated from the casing.
Device casing
Only technicians authorized by the manufacturer are permitted to open the casing. Never insert sharp objects (small screwdrivers, wires, etc.) into the
inside of the device.
Keep the ventilation slits free to ensure good air circulation.Make sure there is at least 3.94 in (10 cm) of space in front of the
ventilation slits of the casing.
Mount the device horizontally or vertically, either as a desktop device,
in the switch cabinet (figure 12 on page 30) or on the wall (figure 14 on
page 31).
Page 9
Installation MACH104
Release 08 01/2019
9
CE marking
The labeled devices comply with the regulations contained in the following European directive(s):
2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
2014/30/EU (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility.
2014/35/EU Directive of the European Parliament and of the Council on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits.
In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address:
Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany
The product can be used in the industrial sector.
Interference immunity: EN 61000-6-2Emitted interference: EN 55032
Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures.
Note: The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values.
LED or laser components
LED or LASER components according to IEC 60825-1 (2014): CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT
Page 10
10
Installation MACH104
Release 08 01/2019
FCC note:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation. Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations. These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment. The device creates and uses high frequencies and can also radiate these frequencies. If it is not installed and used in accordance with this operating manual, it can cause radio transmission interference. The use of this device in a residential area can also cause interference, and in this case the user is obliged to cover the costs of removing the interference.
BSMI note for use in Taiwan
Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures.
Devices with a specification according to BSMI standards CNS 13438, CNS 14336-1 and CNS 15663 are marked on the device label.
᝾֋٬Ҕޣ;!
೭ࢂҘᜪޑၗૻౢ ࠔǴӧۚՐޑᕉნύ٬ҔǴёૈ཮೷ԋ৔ᓎυᘋǴӧ೭
௃ݩΠǴ٬Ҕޣ཮೏؃௦ڗࢌ٤፾྽ޑჹ฼Ƕ
D45625
RoHS
Page 11
Installation MACH104
Release 08 01/2019
11
Declaration o
f
hazardous substances according to
C
hinese regulatory standar
d
estr
i
cte
d
su
b
stances an
d
t
h
e
i
r c
h
em
i
ca
l
sym
b
o
l
ercur
y
admium Hexavalent
C
hromiu
m
o
l
y
b
rom
i
nate
d
bi
p
h
eny
l
s
o
l
y
b
rom
i
nate
d
di
p
h
eny
l
et
h
ers
omponent
eta
l
components
r
i
nte
d
c
i
rcu
i
t
b
oar
d
assem
bly
Ҕނ፦֖Ԗ௃ݩ኱Ңᖂܴ
ൂϡ
ߎឦ೽ҹ
೛ഢӜᆀǺҬඤᐒǴࠠဦȐࠠԄȑǺ
MACH104-20TX-FR...
MACH104-20TX-FR...
MACH104-20TX-F-4PoE...
Equipment name:
S
witch, Model desi
g
nation:
Ҕނ፦ϷځϯᏢ಄ဦ
؄ᙿ
Ϥሽ
ӭྜྷᖄ
ӭྜྷΒ⾸
ႝၡኳಔ
༟ጤکᆫ!ӝނ೽ҹ
ႝྍϡҹ
ower supp
l
y un
i
t
ഢԵIJįġȺຬрıįIJġŸŵġĦȻϷȺຬрıįıIJġŸŵġĦȻ߯ࡰҔނ፦ϐԭϩК֖ໆຬрԭϩК֖ໆ୷ྗǶ
Note 1: “Exceeding 0.1 wt%” and “exceeding 0.01 wt%” indicates that the amount of the restricted substance within the component exceeds the
reference percentage limit
.
Note 2:
“O
” indicates that the amount o
f
the restricted substance does not exceed the re
f
erence percentage limit.
Note 3:
X” indicates that the amount o
f
the restricted substance corresponds with the exemption.
ഢԵijįȺOȻ߯ࡰ၀໨Ҕނ፦ϐԭϩК֖ໆ҂ຬрԭϩК֖ໆ୷ྗǶ
ഢԵĴįȺXȻ߯ࡰ၀໨Ҕނ፦ࣁ௨ନ໨ҞǶ
Page 12
12
Installation MACH104
Release 08 01/2019
Relevant for installations in switch cabinets according to
UL 60950-1
Higher ambient air temperature during operation: If installed in a
closed switch cabinet or a multi-unit switch cabinet, the ambient air temperature inside the switch cabinet during operation can be higher than the ambient air temperature in the room. Install devices in environments that are compatible with the maximum ambient air temperature of the device.
Reduced air flow: When you install the device in a switch cabinet,
make sure that a sufficient air flow is guaranteed in order to safely operate your devices.
Mechanical stress: Check for potential dangers resulting from
unevenly distributed weight when you install the device in a switch cabinet.
Electric circuit overloading: Observe the effects of electric circuit
overloads on the overload current protection and the power supply cables when you connect devices to the power supply. Refer to the device parameters specified on the type plate of the device.
Safe grounding: Make sure that devices installed in switch cabinets
are grounded safely. When you install a device in a switch cabinet, also watch out for power supply connections other than the direct connections to the circuit branch (for example socket boards).
Recycling note
After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country.
Page 13
Installation MACH104
Release 08 01/2019
13
About this manual
The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device.
The following manuals are available as PDF files on the Internet on the Hirschmann product pages (www.hirschmann.com):
Installation user manualBasic Configuration user manualRedundancy Configuration user manualReference manual for the graphical user interfaceCommand Line Interface reference manual
The Network Management Software Industrial HiVision provides you with options for smooth configuration and monitoring. You find further information on the Internet at the Hirschmann product pages: http://
www.hirschmann.com/en/QR/INET-Industrial-HiVision
Page 14
14
Installation MACH104
Release 08 01/2019
Legend
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
Page 15
Installation MACH104
Release 08 01/2019
15
1 Description
1.1 General device description
The MACH104 family provides you with a range of device variants. The device is designed for the special requirements of industrial automation. The device meets the relevant industry standards, provides very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility.
The devices with software variant L2... allow you to set up switched industrial Ethernet networks that conform to the IEEE 802.3 standard.
The devices with software variant L2... allow you to set up switched and routed industrial Ethernet networks that conform to the IEEE 802.3 standard. The devices work without a fan.
The following installation options are available:
19" switch cabinetMounting on a flat surface
You have the option of choosing various media to connect to the end devices and other network components:
Twisted pair cableMultimode F/OSinglemode F/O
The ring redundancy concept allows the network to be reconfigured quickly after a failure.
There are convenient options for managing the device. Manage your devices via:
Web browserTelnetNetwork management software (for example Industrial HiVision)V.24 interface (locally on the device)
The device provides you with a large range of functions, which the manuals for the operating software inform you about. You can download these manuals as PDF files from the Internet on the Hirschmann product pages (www.hirschmann.com). The Hirschmann network components help you ensure continuous communication across all levels of the company.
Page 16
16
Installation MACH104
Release 08 01/2019
1.2 Description of the device variants
1.2.1 MACH104-20TX-F...: Devices with 24 GB ports
MACH104-20TX-F...
4 Gigabit Ethernet combo ports20 Gigabit Ethernet ports
Figure 1: Overview over interfaces, display and operating elements
of the MACH104-20TX-F... 1 - MACH104-20TX-F... device 2 - LED display elements 3 - Signal contact 4 - USB interface 5 - V.24 interface for external management 6 - See the following table, column 1 7 - See the following table, column 2 8 - Power supply connection (on the back of the device)
4 × Gigabit Ethernet ports 4 × Gigabit Ethernet combo ports
10/100/1000 Mbit/s twisted pair, RJ45 sockets
100/1000 Mbit/s F/O, SFP slots Alternatively: 10/100/1000 Mbit/s twisted pair, RJ45 sockets
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-F
2 3 4 51
6
7
7
5
13
911
13 15
17 19 21 23
8
6
24
10 12
14 16
18 20 22 24
6 6 6 6
8
Page 17
Installation MACH104
Release 08 01/2019
17
1.2.2 MACH104-20TX-FR...: Devices with 24 GB ports and
redundant power supply
MACH104-20TX-FR...
4 Gigabit Ethernet combo ports20 Gigabit Ethernet portsThe power supply is designed redundantly.
Figure 2: Overview over interfaces, display and operating elements
of the MACH104-20TX-FR... 1 - MACH104-20TX-FR... device 2 - LED display elements 3 - Signal contact 4 - USB interface 5 - V.24 interface for external management 6 - See the following table, column 1 7 - See the following table, column 2 8 - P1: Power supply connection (on the back of the device) 9 - P2: Redundant power supply connection (on the back of the device)
4 × Gigabit Ethernet ports 4 × Gigabit Ethernet combo ports
10/100/1000 Mbit/s twisted pair, RJ45 sockets
100/1000 Mbit/s F/O, SFP slots Alternatively: 10/100/1000 Mbit/s twisted pair, RJ45 sockets
6
7
5
13
911
13 15
17 19 21 23
8
6
24
10 12
14 16
18 20 22 24
6 6 6 6
7
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-FR
9
8
2 3 4 51
Page 18
18
Installation MACH104
Release 08 01/2019
1.2.3 MACH104-20TX-F-4-PoE...: Devices with 24 GB ports, 4 of them PoE ports
MACH104-20TX-F-4-PoE...
4 Gigabit Ethernet combo ports20 Gigabit Ethernet ports, 4 of which are PoE-capableIntegrated PoE voltage supply for 4 PoE ports
Figure 3: Overview over interfaces, display and operating elements
of the MACH104-20TX-F-4-PoE... 1 - MACH104-20TX-F-4-PoE... device 2 - LED display elements 3 - Signal contact 4 - USB interface 5 - V.24 interface for external management 6 - See the following table, column 1 7 - See the following table, column 2 8 - See the following table, column 3 9 - Power supply connection (on the back of the device) 10 - Integrated PoE PSU (on the back of the device)
4 × Gigabit Ethernet PoE ports
4 × Gigabit Ethernet combo ports 4 × Gigabit Ethernet
ports
10/100/1000 Mbit/s twisted pair, RJ45 sockets with PoE
100/1000 Mbit/s F/O, SFP slots Alternatively: 10/100/1000 Mbit/s twisted pair, RJ45 sockets
10/100/1000 Mbit/s twisted pair, RJ45 sockets
6
7
5
13
911
13 15
17 19 21 23
8
6
24
10 12
14 16
18 20 22 24
8 8 8 8
7
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-F-4PoE
P
2 3 4 51
10
9
Page 19
Installation MACH104
Release 08 01/2019
19
1.3 Supply voltage
Note: Note the safety instructions in “Requirements for connecting electrical
wires” on page 6.
1.3.1 MACH104-20TX-F...
Supply voltage is connected via a non-heating appliance socket.
Figure 4: MACH104-20TX-F connections on the back of the device
1 - Power supply 100 V AC ... 240 V AC 2 - MACH104-20TX-F... device
1.3.2 MACH104-20TX-FR...
Supply voltage is connected via non-heating appliance sockets. The supply voltage can be connected redundantly. Both inputs are uncoupled. The load is not distributed. With redundant supply, the standard power supply supplies the device on its own. The redundant power supply becomes active automatically if the standard power supply fails. Normally the redundant power supply runs in stand-by mode. The supply voltage is electrically isolated from the casing.
Figure 5: MACH104-20TX-FR... connections on the back of the device
1 - Standard power supply 100 V AC ... 240 V AC 2 - MACH104-20TX-FR... device 3 - Redundant power supply 100 V AC ... 240 V AC
With a non-redundant supply of the supply voltage, the device reports the loss of a supply voltage. You can prevent this message by applying the supply voltage via both inputs, or by changing the configuration in the Management.
1
2
31 2
Page 20
20
Installation MACH104
Release 08 01/2019
1.3.3 MACH104-20TX-F-4-PoE...
Supply voltage is connected via a non-heating appliance socket.
Figure 6: MACH104-20TX-F-4-PoE... connections on the back of the device
1 - Standard power supply 100 V AC ... 240 V AC 2 - MACH104-20TX-F-4-PoE... device
1.4 Ethernet ports
You can connect end devices and other segments to the device ports using twisted pair cables or optical fibers (F/O).
1.4.1 10/100/1000 Mbit/s twisted pair port
This port is an RJ45 socket. The 10/100/1000 Mbit/s twisted pair port allows you to connect network components according to the IEEE 802.3 10BASE-T/100BASE-TX/ 1000BASE-T standard. This port supports:
Autonegotiation Autopolarity Autocrossing (if autonegotiation is activated)1000 Mbit/s full duplex100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
Note: Some of these ports also support Power over Ethernet (PoE).
See “PoE ports” on page 21.
Delivery state: Autonegotiation activated The port casing is electrically connected to the front panel. The pin assignment corresponds to MDI-X.
12
Page 21
Installation MACH104
Release 08 01/2019
21
1.4.2 100 Mbit/s F/O port
This port is an SFP slot. The 100 Mbit/s F/O port allows you to connect network components according to the IEEE 802.3 100BASE-FX standard. This port supports:
Full or half duplex mode
Default setting: Full duplex
1.4.3 1000 Mbit/s F/O port
This port is an SFP slot. The 1000 Mbit/s F/O port offers you the ability to connect network components according to the IEEE 802.3 100BASE-SX/1000BASE-LX standard. This port supports:
Autonegotiation Full duplex mode
Delivery state: Autonegotiation activated
1.4.4 PoE ports
The device variants MACH104-20TX-F-4-PoE... support Power over Ethernet (PoE) in accordance with IEEE 802.3af.
Figure Pin Function Ports with PoE support:
PoE voltage feed
1 BI_DB+ Minus terminal of the supply voltage 2BI_DB Minus terminal of the supply voltage 3 BI_DA+ Plus terminal of the supply voltage 4BI_DD+ 5BI_DD 6BI_DA Plus terminal of the supply voltage 7BI_DC+ 8BI_DC
Table 1: Pin assignment of a 1000 MBit/s TP interface in MDI-X mode, RJ45
socket - for PoE with the power supplied via the wire pairs transmitting the signal
Ports PoE support
1 to 4 Yes 5 to 20 No
Table 2: Twisted-pair ports and PoE support
1 2 3 4 5 6 7 8
Page 22
22
Installation MACH104
Release 08 01/2019
The PoE ports support the connection and a remote power supply of (for example) IP phones (Voice-over-IP), webcams, sensors, print servers, and WLAN access points. With PoE, these end devices are powered via the twisted pair cable.
The following applies to PoE ports:
max. Powered Device (PD) class 0 (15.4 W)The PoE power is supplied via the wire pairs transmitting the signal
(phantom voltage).
The individual ports (joint PoE voltage) are not electrically insulated from
each other.
1.4.5 Combo ports
You have the option of alternatively connecting a twisted pair cable via a RJ45 socket or an optical fiber via a SFP transceiver to a combo port. By inserting a SFP transceiver, you deactivate automatically the corresponding twisted pair interface.
1.5 Display elements
After the supply voltage is set up, the Software starts and initializes the device. Afterwards, the device performs a self-test. During this process, various LEDs light up. The process takes around 15 seconds.
Figure 7: MACH104-Display elements
1 - Display elements device status 2 - Display elements port status
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-F
7
5
13
911
13 15
17 19 21 23
8
6
24
10 12
14 16
18 20 22 24
21
Page 23
Installation MACH104
Release 08 01/2019
23
1.5.1 Device state
These LEDs provide information about conditions which affect the operation of the whole device. The following table applies to the stated device variants only:
MACH104-20TX-FR...
The following table applies to the stated device variants only:
MACH104-20TX-F...MACH104-20TX-F-4-PoE...
The following table applies to every device variant:
LED Display Color Activity Meaning
P Supply
voltage
none Supply voltages 1 and 2 are too low. green lights up Supply voltage 1 and 2 is on yellow lights up Supply voltage 1 or 2 is on
LED Display Color Activity Meaning
P Supply
voltage
none Supply voltage is too low green lights up Supply voltage is on
LED Display Color Activity Meaning
Sb Stand-by none Stand-by mode not enabled
green lights up Standby mode enabled
FAULT Signal
contact
none The signal contact is closed, it is not
reporting any detected errors.
red lights up The signal contact is open - it is reporting a
detected error.
RM Ring
Manager
none The RM function is deactivated. green lights up The RM function is active.
The redundant port is disabled.
flashing The device detects an incorrect
configuration of the HIPER-Ring (for example the ring is not connected to the ring port).
yellow lights up The RM function is active.
The redundant port is enabled.
FAULT
RM
Sb
P
Page 24
24
Installation MACH104
Release 08 01/2019
If the manual setting is active on the signal contact “FAULT”, then the error display is independent of the setting of the signal contact.
1.5.2 Port status
These LEDs display port-related information.
RM and Sb
ACA memory operations
green Flashing
alternately
Error in the memory operation
flashes synchronously 2 × per period
Saves a configuration file from the storage medium ACA to the device.
flashes synchronously 1 × per period
Saves a configuration file from the device to the storage medium ACA.
LED Display Color Activity Meaning
LS Link status none Device detects an invalid or missing
link
green lights up Device detects a valid link
flashes 1 time a period Port is switched to stand-by flashes 3 times a
period
Port is switched off
DA Data traffic yellow flashing Device is transmitting and/or receiving
data
LED Display Color Activity Meaning
LS DA2
LS DA1
Page 25
Installation MACH104
Release 08 01/2019
25
1.6 Management interfaces
1.6.1 V.24 interface (external management)
The V.24 interface is an RJ11 socket. The V.24 user interface is serial and allows you to connect the following devices directly:
External management station (VT100 terminal or PC with appropriate
terminal emulation). With this management station, the Command Line Interface (CLI) is available to you. Furthermore, the system monitor is available to you at the system start.
The AutoConfiguration Adapter ACA11
The interface casing is electrically connected to the front panel. The V.24 interface is not electrically isolated from the supply voltage.
Figure 8: Pin assignment of the V.24 interface and the DB9 plug
You will find the order number for the terminal cable, which is ordered separately, in the Technical Data section (see on page 37 “Technical data”).
VT100 terminal settings
Speed 9600 Baud Data 8 bit Stopbit 1 bit Handshake off Parity none
1
1
8
5
6
2 3
5
1 2 3 4 5 6
CTS n.c. TX GND RX RTS
RJ11
DB9
RJ11
DB9
Page 26
26
Installation MACH104
Release 08 01/2019
1.6.2 USB interface
The USB interface allows you to connect the AutoConfiguration Adapter ACA21-USB (EEC) storage medium. This is used for saving/loading the configuration data and diagnostic information, and for loading the software.
See “Accessories and order numbers” on page 44.
1.7 Signal contact
Figure 9: MACH104 device, front view
1 - Signal contact
The signal contact is a potential-free relay contact. The signal contact is open when the device is not connected to a power supply. The signal contact allows you to control external devices or monitor device functions. In the configuration, you specify how the device uses the signal contact. You find detailed information regarding possible applications and configuration of the signal contact in the software user documentation on the Hirschmann product pages (www.hirschmann.com).
Figure Pin Function
1VCC (VBus) 2 Data 3 + Data 4 Ground (GND)
Table 3: Pin assignment of the USB interface
1
2
4
3
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-F
1
Page 27
Installation MACH104
Release 08 01/2019
27
2Installation
On delivery, the device is ready for operation. The following procedure has been proven to be successful for the assembly of the device:
Checking the package contentsInstalling an SFP transceiver (optional)Wiring and installing the signal contactInstalling the device and groundingOperating the deviceConnecting data cables
Note: Note the safety instructions in “Requirements for connecting electrical
wires” on page 6.
2.1 Checking the package contents
Check whether the package includes all items named in the section
“Scope of delivery, order numbers and accessories” on page 44.
Check the individual parts for transport damage.
2.2 Installing an SFP transceiver (optional)
Prerequisites:
Exclusively use Hirschmann SFP transceivers.
See “Accessories and order numbers” on page 44.
Figure 10: Installing SFP transceivers: Installation sequence
1
2
3
Page 28
28
Installation MACH104
Release 08 01/2019
Proceed as follows:
Take the SFP transceiver out of the transport packaging (1).Remove the protection cap from the SFP transceiver (2).Push the SFP transceiver with the lock closed into the slot until it latches
in (3).
2.3 Wiring and installing the signal contact
Figure 11: 2-pin terminal block
Every time you connect the electrical conductors, make sure that the following requirements are met:
The electrical wires are voltage-free.The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
See “General technical data” on page 37.
Remove the terminal connector from the device.Connect the signal contact lines with the terminal block connections.Mount the terminal block for the signal contact on the front of the device
using the screw lock. Check whether the terminal block is correctly plugged and screwed on.
You find the prescribed tightening torque in chapter:
“General technical data” on page 37
WARNING
ELECTRIC SHOCK
Never insert sharp objects (small screwdrivers, wires, or similar items) into the connection terminals for the signal lines, and do not touch the terminals.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
FAULT
Page 29
Installation MACH104
Release 08 01/2019
29
2.4 Installing the device and grounding
The device can be mounted on a flat surface, in a 19" standard switch cabinet, or on the wall.
2.4.1 Selecting the assembly location
Select the assembly location according to the safety guidelines (see on
page 5 “Safety instructions”).
When selecting the assembly location, also make sure the following requirements are met:
The assembly location can be accessed for maintenance and repair work.The LED display elements are clearly visible.Twisted pair cables are at a sufficient distance from potential sources of
electrical interference, such as power supply cables.
The device has a separate power source with a ground connection. The
power supply can be interrupted by means of a separate isolator or power switch. We recommend using overvoltage protection for all devices.
2.4.2 Mounting on a flat surface
Before operating the device on a flat surface, such as a table, stick the supplied casing feet onto the bottom of the device, with approx. 0.8 in (2 cm) of space from the corners. If necessary, remove any dirt from the bottom of the device where you
want to place the stick-on feet.
Remove the protective foil from the adhesive surface of a casing foot and
attach the casing foot on the device.
2.4.3 Mounting in a switch cabinet
Note: Note the instructions on installations in 19" switch cabinets according to UL 60950-1.
See “Relevant for installations in switch cabinets according to UL 60950-1” on page 12.
Note: For more information on sliding/mounting rails and how to install them, please contact your switch cabinet manufacturer.
The devices are designed to be mounted in a 19" switch cabinet. Ensure adequate ventilation. If necessary, install an additional fan in the
switch cabinet to prevent the device from overheating.
Measure the depth of the 19" switch cabinet so as to allow the power
supply cables to be fitted at the back and the data cables to be fitted at the front.
Assemble the sliding or mounting rails in the 19" switch cabinet as
specified by the manufacturer.
Page 30
30
Installation MACH104
Release 08 01/2019
Figure 12: Assembly in a switch cabinet with sliding/mounting rails
1 - MACH104 device 2 - sliding/mounting rail 3 - 19" switch cabinet
Figure 13: Mounting the MACH104 in the 19" cabinet
Fasten the device by screwing the brackets to the switch cabinet.
Note: When operating the device in an environment with strong vibrations, you have the option to additionally fasten the device to the switch cabinet using 2 holding brackets on the back of the device. You obtain the additional brackets as accessories.
See “Accessories and order numbers” on page 44.
2.4.4 Mounting on the wall
Remove the screws on the pre-installed mounting brackets.Move the two pre-installed mounting brackets into the position shown
below.
Use the screws to secure the mounting brackets on the device.
1
3
2
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-F
Page 31
Installation MACH104
Release 08 01/2019
31
Additionally attach 2 brackets to the back of the device.
See figure 14.
You obtain the additional brackets as accessories.
See “Accessories and order numbers” on page 44.
Fasten the device by screwing the brackets to the wall.
Figure 14: Vertical mounting on the wall
2.4.5 Grounding the device
The device is grounded via the power supply connections.
Page 32
32
Installation MACH104
Release 08 01/2019
2.5 Operating the device
Note: Note the safety instructions in “Requirements for connecting electrical
wires” on page 6.
By connecting the voltage supply via the voltage supply socket(s), you start the operation of the device.
2.6 Connecting data cables
Note: Verify that you connect only optical ports with the same optical transmission properties with each other.
Further information:
See “Ethernet ports” on page 20.
Connect the data cables according to your requirements.
WARNING
ELECTRIC SHOCK
Connect only a supply voltage that corresponds to the type plate of your device.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Page 33
Installation MACH104
Release 08 01/2019
33
3 Making basic settings
Note: Two or more devices configured with the same IP address can cause unpredictable operation of your network. Install and maintain a process that assigns a unique IP address to every device in the network.
When you install the device for the first time enter the IP parameters.
The device provides the following options for entering the IP parameters during the first installation:
Configuration via DHCP (state on delivery)Input via the V.24 interfaceInput via the HiView or Industrial HiVision application. You find further
information about the applications HiView or Industrial HiVision on the Internet at the Hirschmann product pages:
HiView
http://www.hirschmann.com/en/QR/INET-HiView
Industrial HiVision
http://www.hirschmann.com/en/QR/INET-Industrial-HiVision
Configuration via BOOTPConfiguration via DHCP (Option 82)AutoConfiguration Adapter
Further information on the basic settings of the device can be found in the “Basic Configuration” user manual.
Page 34
34
Installation MACH104
Release 08 01/2019
3.1 Default settings
The device looks for the IP address using DHCPManagement password:
user, password: public (read only) admin, password: private (read and write)
V.24 data rate: 9600 BaudRing redundancy disabledEthernet ports: link status is not evaluated (signal contact)Optical 100 Mbit/s ports: 100 Mbit/s full duplex
Other ports: Autonegotiation
Redundancy manager disabled
(DIP switch RM and Standby: ON)
Standby coupling disabled
(DIP switch RM and Standby: ON) Port 3 = control port, Port 4 = coupling port for redundant ring coupling
Rapid Spanning Tree enabled
Page 35
Installation MACH104
Release 08 01/2019
35
4 Maintenance and service
When designing this device, Hirschmann largely avoided using high-wear
parts. The parts subject to wear and tear are dimensioned to last longer than the lifetime of the product when it is operated normally. Operate this device according to the specifications.
See “Technical data” on page 37.
Relays are subject to natural wear. This wear depends on the frequency
of the switching operations. Check the resistance of the closed relay contacts and the switching function depending on the frequency of the switching operations.
Hirschmann is continually working on improving and developing their
software. Check regularly whether there is an updated version of the software that provides you with additional benefits. You find information and software downloads on the Hirschmann product pages on the Internet (http://www.hirschmann.com).
Internal fuses are triggered only in the case of a detected error in the
device. In case of damage or malfunction of the device, turn off the supply voltage and return the device to the plant for inspection.
Depending on the degree of pollution in the operating environment, check
at regular intervals that the ventilation slots in the device are not obstructed.
Note: You find information on settling complaints on the Internet at http://
www.beldensolutions.com/en/Service/Repairs/index.phtml.
Page 36
36
Installation MACH104
Release 08 01/2019
5Deinstallation
5.1 Removing the device
Disconnect the data cables.Disable the supply voltage.Disconnect the supply voltage.Remove the terminal connector from the device.To detach the device from the switch cabinet or the wall, remove the
screws from the brackets on the device.
Figure 15: Disassembling the device
5.2 Removing an SFP transceiver (optional)
Figure 16: De-installing SFP transceivers: De-installation sequence
Proceed as follows:
Open the locking mechanism of the SFP transceiver (1).Pull the SFP transceiver out of the slot via the open locking
mechanism (2).
Close the SFP transceiver with the protection cap (3).
V.24USB
Aufkleber MAC-Adresse
P
FAULT
FAULT
Sb
RM
5
6
7
8
13
24
911
10 12
13 15
14 16
17 19
18 20
21 23
22 24
MACH104-20TX-F
1
2
3
Page 37
Installation MACH104
Release 08 01/2019
37
6 Technical data
6.1 General technical data
Dimensions See “Dimension drawings” on page 38. Weight MACH104-20TX-F... 9.26 lb (4.2 kg)
MACH104-20TX-FR... 9.7 lb (4.4 kg) MACH104-20TX-F-4-PoE... 10.14 lb (4.6 kg)
Supply voltage Rated voltage range 100 V AC ... 240 V AC, 50 Hz ... 60 Hz
Voltage range including maximum tolerances
90 V AC ... 265 V AC, 47 Hz ... 63 Hz
Current consumption
Rated current for devices without PoE
max. 0.3 A (240 V AC) max. 0.5 A (100 V AC)
Rated current for devices with PoE
max. 0.9 A (240 V AC)
max. 1.7 A (100 V AC) Activation current typ. < 40 A at 265 V AC and cold start PoE power Maximum number of Powered
Devices (PDs)
This applies to the following device
variants only:
MACH104-20TX-F-4-PoE...
4 × Powered Device (PD) Class 0 (15.4 W) Power loss buffer > 12 ms (115 V AC) Overload current
protection at input
Non-replaceable fuse
Climatic conditions during operation
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
+32 °F ... +122 °F (0 °C ... +50 °C)
Humidity 20 % ... 90 %
(non-condensing)
Air pressure min. 795 hPa (+6562 ft; +2000 m)
max. 1060 hPa (−1312 ft; −400 m) Climatic conditions
during storage
Ambient air temperature
b
b. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
–4 °F ... +185 °F (20 °C ... +85 °C)
Humidity 10 % ... 95 %
(non-condensing)
Air pressure min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (−1312 ft; −400 m) Signal contact Switching current max. 1 A, SELV
Switching voltage max. 60 V DC or max. 30 V AC, SELV Connection type 2-pin terminal block
max. conductor cross section AWG16
(1.3 mm²)
Tightening torque 2.2 lb-in (0.25 Nm) Pollution degree 2 Protection classes Laser protection Class 1 in compliance with IEC 60825-1
Degree of protection IP30
Page 38
38
Installation MACH104
Release 08 01/2019
6.2 Dimension drawings
6.3 EMC and immunity
EMC interference immunity
IEC/EN 61000-4-2 Electrostatic discharge
Contact discharge Air discharge
6kV 8kV
IEC/EN 61000-4-3 Electromagnetic field
80 MHz ... 3000 MHz max. 20 V/m
IEC/EN 61000-4-4 Fast transients (burst)
Power line Data line
2kV 4kV
mm inch
31,75
1.25
462,6
18.21
43,9
1.73
3,3
0.13
3,3
0.13
4,5
0.18
342
13.46
19,3
0.76
19,3
0.76
444
17.48
Page 39
Installation MACH104
Release 08 01/2019
39
IEC/EN 61000-4-5 Voltage surges
Power line, line / line Power line, line / ground Data line
1 kV 2kV 4kV
IEC/EN 61000-4-6 Conducted disturbances
150 kHz ... 80 MHz 10 V
EN 61000-4-9 Pulse magnetic fields 300 A/m
EMC interference emission
EN 55032 Class A Yes FCC 47 CFR Part 15 Class A Yes
EMC interference immunity
Page 40
40
Installation MACH104
Release
08
01/2019
6.4 Network range
Note: The line lengths specified for the transceivers apply for the respective fiber data (fiber attenuation and Bandwidth Length Product (BLP)/ Dispersion).
10/100/1000 Mbit/s twisted pair port
Length of a twisted pair segment max. 328 ft (100 m) (for Cat5e cable)
Table 4: Network range: 10/100/1000 Mbit/s twisted pair port
Product code M-FAST-SFP-...
Mode
a
a. MM = Multimode, SM = Singlemode, LH = Singlemode Longhaul
Wave length Fiber System
attenuation
Example for F/O cable length
b
b. Including 3 dB system reserve when compliance with the fiber data is observed.
Fiber attenuation
BLP/Dispersion
-MM/LC... MM 1310 nm 50/125 µm 0 dB ... 8 dB 0 mi ... 3.11 mi (0 km ... 5 km)
1.0 dB/km 800 MHz×km
-MM/LC... MM 1310 nm 62.5/125 µm 0 dB ... 11 dB 0 mi ... 2.49 mi (0 km ... 4 km)
1.0 dB/km 500 MHz×km
-SM/LC... SM 1310 nm 9/125 µm 0 dB ... 13 dB 0 mi ... 15.53 mi (0 km ... 25 km)
0.4 dB/km 3.5 ps/(nm×km)
-SM+/LC... SM 1310 nm 9/125 µm 10 dB ... 29 dB 15.53 mi ... 40.39 mi (25 km ... 65 km)
0.4 dB/km 3.5 ps/(nm×km)
-LH/LC... SM 1550 nm 9/125 µm 10 dB ... 29 dB 29.20 mi ... 64.62 mi (47 km ... 104 km)
0.25 dB/km 19 ps/(nm×km)
-LH/LC... SM 1550 nm 9/125 µm 10 dB ... 29 dB 14.29 mi ... 86.99 mi (55 km ... 140 km)
0.18 dB/km
c
c. With ultra-low-loss optical fiber.
18 ps/(nm×km)
Table 5: Fiber port 100BASE-FX (SFP fiber optic Fast Ethernet Transceiver)
Page 41
Installation MACH104
Release
08
01/2019
41
Product code M-SFP-...
Mode
a
a. MM = Multimode, SM = Singlemode, LH = Singlemode Longhaul
Wave length Fiber System
attenuation
Example for F/O cable length
b
b. Including 3 dB system reserve when compliance with the fiber data is observed.
Fiber attenuation
BLPc/Dispersion
c. Using the bandwidth-length product is inappropriate for expansion calculations.
-SX/LC... MM 850 nm 50/125 µm 0 dB ... 7.5 dB 0 mi ... 0.34 mi
(0 km ... 0.55 km)
3.0 dB/km 400 MHz×km
-SX/LC... MM 850 nm 62.5/125 µm 0 dB ... 7.5 dB 0 mi ... 0.17 mi
(0 km ... 0.275 km)
3.2 dB/km 200 MHz×km
-MX/LC... MM 1310 nm 50/125 µm 0 dB ... 12 dB 0 km ... 1.5 km 1.0 dB/km 800 MHz×km
-MX/LC... MM 1310 nm 62.5/125 µm 0 dB ... 12 dB 0 mi ... 31.06 mi
(0 km ... 50 km)
1.0 dB/km 500 MHz×km
-LX/LC... MM 1310 nm
d
d. With F/O adapter compliant with IEEE 802.3-2002 Clause 38 (single-mode fiber offset-launch mode conditioning patch cord).
50/125 µm 0 dB ... 10.5 dB 0 mi ... 0.34 mi
(0 km ... 0.55 km)
1.0 dB/km 800 MHz×km
-LX/LC... MM 1310 nm
e
e. With F/O adapter compliant with IEEE 802.3-2002 Clause 38 (single-mode fiber offset-launch mode conditioning patch cord).
62.5/125 µm 0 dB ... 10.5 dB 0 mi ... 0.34 mi (0 km ... 0.55 km)
1.0 dB/km 500 MHz×km
-LX/LC... SM 1310 nm 9/125 µm 0 dB ... 10.5 dB 0 mi ... 12.43 mi (0 km ... 20 km)
f
f. Including 2.5 dB system reserve when compliance with the fiber data is observed.
0.4 dB/km 3.5 ps/(nm×km)
-LX+/LC... SM 1310 nm 9/125 µm 5 dB ... 20 dB 8.70 mi ... 26.10 mi (14 km ... 42 km)
0.4 dB/km 3.5 ps/(nm×km)
-LH/LC... LH 1550 nm 9/125 µm 5 dB ... 22 dB 14.29 mi ... 49.71 mi (23 km ... 80 km)
0.25 dB/km 19 ps/(nm×km)
-LH+/LC LH 1550 nm 9/125 µm 15 dB ... 30 dB 44.12 mi ... 67.11 mi (71 km ... 108 km)
0.25 dB/km 19 ps/(nm×km)
-LH+/LC LH 1550 nm 9/125 µm 15 dB ... 30 dB 44.12 mi ... 79.54 mi (71 km ... 128 km)
0.21 dB/km (typically)
19 ps/(nm×km)
Table 6: F/O port 1000BASE-FX (SFP fiber optic Gigabit Ethernet Transceiver)
Page 42
42
Installation MACH104
Release
08
01/2019
Product code M-SFP-BIDI...
Mode
a
a. MM = Multimode, SM = Singlemode, LH = Singlemode Longhaul
Wave lengthTXWave lengthRXFiber System
attenuation
Example for F/O cable length
b
b. Including 3 dB system reserve when compliance with the fiber data is observed.
Fiber attenuation
Dispersion
Type A LX/LC EEC SM 1310 nm 1550 nm 9/125 µm 0 dB ... 11 dB 0 km ... 12.43 mi
(0 km ... 20 km)
0.4 dB/km 3.5 ps/(nm×km)
Type B LX/LC EEC SM 1550 nm 1310 nm 9/125 µm 0 dB ... 11 dB 0 mi ... 12.43 mi
(0 km ... 20 km)
0.25 dB/km 19 ps/(nm×km)
Type A LH/LC EEC LH 1490 nm 1590 nm 9/125 µm 5 dB ... 24 dB 14.29 mi ... 49.71 mi
(23 km ... 80 km)
0.25 dB/km 19 ps/(nm×km)
Type B LH/LC EEC LH 1590 nm 1490 nm 9/125 µm 5 dB ... 24 dB 14.29 mi ... 49.71 mi
(23 km ... 80 km)
0.25 dB/km 19 ps/(nm×km)
Table 7: F/O port (bidirectional Gigabit Ethernet SFP transceiver)
Page 43
Installation MACH104
Release 08 01/2019
43
6.5 Power consumption/power output
MACH104device Maximum
power consumption
Maximum power output
MACH104-20TX-F... 35 W 119 Btu (IT)/h MACH104-20TX-FR... 35 W 119 Btu (IT)/h MACH104-20TX-F-4-PoE..., with 4 ×
Class 0 Powered-Device connected
110 W 170 Btu (IT)/h
Page 44
44
Installation MACH104
Release 08 01/2019
7 Scope of delivery, order numbers and
accessories
MACH104-20TX-F...
MACH104-20TX-FR...
MACH104-20TX-F-4-PoE...
Accessories and order numbers
Note: Note that products recommended as accessories may have characteristics that do not fully correspond to those of the respective product. This may limit their possible usage in the overall system.
Number Article
1 × General safety instructions 1× Device 1 × 2-pin terminal block for signal contact 2 × Brackets with fastening screws (pre-mounted) 1 × Casing feet, stick on 1 × Non-heating appliance cable (Euro model)
Number Article
1 × General safety instructions 1× Device 1 × 2-pin terminal block for signal contact 2 × Brackets with fastening screws (pre-mounted) 1 × Casing feet, stick on 2 × Non-heating appliance cable (Euro model)
Number Article
1 × General safety instructions 1× Device 1 × 2-pin terminal block for signal contact 2 × Brackets with fastening screws (pre-mounted) 1 × Casing feet, stick on 1 × Non-heating appliance cable (Euro model)
MACH104device Order number
MACH104-20TX-F-L2P 942 003-001 MACH104-20TX-FR-L2P 942 003-101 MACH104-20TX-F-4-PoE-L2P 942 003-201 MACH104-20TX-F-L3P 942 003-002 MACH104-20TX-FR-L3P 942 003-102 MACH104-20TX-F-4-PoE-L3P 942 003-202
Page 45
Installation MACH104
Release 08 01/2019
45
Name Order number
AutoConfiguration AdapterACA21-USB (EEC) 943 271-003 AutoConfiguration AdapterACA11 943 751-001 Terminal cable 943 301-001 2-pin terminal block (50 pieces) 943 845-010 Bracket for fastening the casing 943 943-001 Bracket, long (+ 1.97 in (50 mm)), for fastening the casing (extra) 943 943-101 Network management software Industrial HiVision 943 156-xxx OPC Server software HiOPC 943 055-001
Gigabit Ethernet SFP transceiver Order number
M-SFP-TX/RJ45 943 977-001 M-SFP-TX/RJ45 EEC 942 161-001 The following operating conditions apply to twisted pair transceivers:
Usable with:
- HiOS as of software version 03.0.00
- Classic Switch software, as of software version 04.1.00.
- HiSecOS as of software version 01.2.00 Do not use with the following devices:
- SPIDER II- MSP/MSM
- EES
Longer RSTP switching times and link loss detection times compared to twisted pair ports
provided by the device directly.
Not applicable for combo and Fast Ethernet ports.Only support of the autonegotiation mode including autocrossing.
M-SFP-SX/LC 943 014-001 M-SFP-SX/LC EEC 943 896-001 M-SFP-MX/LC EEC 942 108-001 M-SFP-LX/LC 943 015-001 M-SFP-LX/LC EEC 943 897-001 M-SFP-LX+/LC 942 023-001 M-SFP-LX+/ LC EEC 942 024-001 M-SFP-LH/LC 943 042-001 M-SFP-LH/LC EEC 943 898-001 M-SFP-LH+/LC 943 049-001 M-SFP-LH+/LC EEC 942 119-001 SFP-GIG-LX/LC
a
a. You find further information on certifications on the Internet at the Hirschmann product
pages (www.hirschmann.com).
942 196-001
SFP-GIG-LX/LC EEC
a
942 196-002
Page 46
46
Installation MACH104
Release 08 01/2019
Fast Ethernet SFP transceiver Order number
M-FAST SFP-TX/RJ45 942 098-001 M-FAST SFP-TX/RJ45 EEC 942 098-002 The following operating conditions apply to twisted pair transceivers:
Usable with:
- HiOS as of software version 03.0.00
- for PRP ports on RSP devices, as of software version 02.0.01
- for PRP ports on EES devices, as of software version 02.0.02
- Classic switch software as of software version 08.0.00
- HiSecOS as of software version 01.2.00
Longer RSTP switching times and link loss detection times compared to twisted pair ports
provided by the device directly.
Not applicable for combo ports.Not applicable for ports which support only Gigabit Ethernet.To set autocrossing manually is currently not possible.
M-FAST SFP-MM/LC 943 865-001 M-FAST SFP-MM/LC EEC 943 945-001 M-FAST SFP-SM/LC 943 866-001 M-FAST SFP-SM/LC EEC 943 946-001 M-FAST SFP-SM+/LC 943 867-001 M-FAST SFP-SM+/LC EEC 943 947-001 M-FAST SFP-LH/LC 943 868-001 M-FAST SFP-LH/LC EEC 943 948-001 SFP-FAST-MM/LC
a
a. You find further information on certifications on the Internet at the Hirschmann product
pages (www.hirschmann.com).
942 194-001
SFP-FAST-MM/LC EEC
a
942 194-002
SFP-FAST-SM/LC
a
942 195-001
SFP-FAST-SM/LC EEC
a
942 195-002
Bidirectional Gigabit Ethernet SFP transceiver Order number
M-SFP-BIDI Type A LX/LC EEC 943 974-001 M-SFP-BIDI Type B LX/LC EEC 943 974-002 M-SFP-BIDI Type A LH/LC EEC 943 975-001 M-SFP-BIDI Type B LH/LC EEC 943 975-002 M-SFP-BIDI Bundle LX/LC EEC (type A + B) 943 974-101 M-SFP-BIDI Bundle LH/LC EEC (type A + B) 943 975-101
Page 47
Installation MACH104
Release 08 01/2019
47
8 Underlying technical standards
The device generally fulfills the technical standards named in their current versions. The device has an approval based on a specific standard exclusively if the approval indicator appears on the device casing. If your device has a shipping approval according to Germanischer Lloyd or DNV GL, you find the respective approval mark printed on the device label. You will find out whether your device has other shipping approvals on the Hirschmann website under www.hirschmann.com in the product information.
Name
CSA 22.2 No. 60950-1 Information Technology Equipment – Safety – Part 1: General
Requirements
EN 61000-6-2 Electromagnetic compatibility (EMC) – Part 6-2: Generic
standards – Immunity for industrial environments
EN 55032 Electromagnetic compatibility of multimedia equipment –
Emission Requirements FCC 47 CFR Part 15 Code of Federal Regulations EN 60950-1 Information technology equipment – Safety – Part 1: General
requirements IEEE 802.1D MAC Bridges (switching function) IEEE 802.1Q Virtual LANs (VLANs, MRP, Spanning Tree) IEEE 802.1w Rapid Reconfiguration IEEE 802.3 Ethernet UL 60950-1 Information technology equipment – Safety – Part 1: General
requirements
Table 8: List of the technical standards
Page 48
48
Installation MACH104
Release 08 01/2019
A Further support
Technical questions
For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly.
You find the addresses of our partners on the Internet at http://
www.hirschmann.com.
A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at https://
hirschmann-support.belden.com.
This site also includes a free of charge knowledge base and a software download section.
Hirschmann Competence Center
The Hirschmann Competence Center is ahead of its competitors on three counts with its complete range of innovative services:
Consulting incorporates comprehensive technical advice, from system
evaluation through network planning to project planning.
Training offers you an introduction to the basics, product briefing and user
training with certification. You find the training courses on technology and products currently available at http://www.hicomcenter.com.
Support ranges from the first installation through the standby service to
maintenance concepts.
With the Hirschmann Competence Center, you decided against making any compromises. Our client-customized package leaves you free to choose the service components you want to use.
Internet:
http://www.hicomcenter.com
Page 49
Installation MACH104
Release 08 01/2019
49