Hirschmann LION-GIGA-1SX User Manual

Page 1
WORKGROUP SWITCH
1000BASE-SX GIGABIT ETHERNET UPLINK MODULE
Hirschmann’s LION-GIGA-1SX 1000Base-SX SC Gigabit Ethernet Uplink Module provides a short wavelength (850 nm) Gigabit port that can be used for a high-speed backbone or server connections. It contains one 1000Base-SX port that can be connected to a site up to 550 m (1805 ft) away with fiber cable.
Module Port LEDs
Port LEDs for the module are located on the front panel of the switch. These LEDs provide port status for “at-a­glance” network monitoring. The following table details the indicator functions provided by the LION-24TP:
INSTALLING THE MODULE
CAUTION: The LION-GIGA-1SX module is designed for the LION-24TP switch only. Do not try to install this module in any other units.
The LION-GIGA-1SX Uplink Module installs in either of the two front panel slots on the LION-24TP switch. To install the module, follow the instructions below.
Equipment Checklist
After unpacking the LION-GIGA-1SX Uplink Module, check the contents of the box to be sure you’ve received the following items:
• One LION-GIGA-1SX Uplink Module
• This document
Handling the Module
CAUTION: The LION-GIGA-1SX Uplink Module can easily be damaged by electrostatic discharge. To prevent electrostatic damage, observe the following guidelines:
• Do not remove the module from its packaging until you are ready to install it.
• Do not touch any of the module’s pins, connectors or components.
• Hold the module only by its edges or front p anel.
• Wear an anti-static wristband connected to a suitable earth ground whenever handling the module.
• Store or transport this modul e only in appropriate anti­static packaging.
Instructions
CAUTION: The switch must be powered off before installing or replacing any module.
1. Power off the switch: Disconnect the AC power
cord from the switch.
2. Remove network cables: If you are replacing a
module, remove the cable attached to the port on the module.
3. Loosen the screws on the installed module or
slot faceplate: Using your fingers or a flathead screwdriver, turn the screws securing the module (or faceplate on the slot) in a counter-clockwise direction until they are free of the chassis. Be sure not to completely remove the screws from the module or faceplat e.
4. Remove the installed module or faceplate:
Firmly pull on the screws until the module is free of the switch. Carefully slide the module straight out of the slot.
Keep the original faceplate for future use. If you should remove the module, replace the faceplate to prevent dust and debris from entering the unit and to maintain proper air flow.
5. Insert the new module into the switch: Holding the new module with the text on the front panel upright, carefully slide the module into the switch slot and press gently until it snaps into place. Be sure the new module’s front panel is flush with the switch panel.
6. Secure the new module: Secure the new module in place by screwing the attached screws clockwise into the switch’s chassis. Tighten them enough to secure the module, but not so tight as to prevent them from being unscrewed by hand.
7. Connect the network cable: Connect fiber cable to the port on the newly installed module. See “Connectivity Guidelines” in this guide for further information.
8. Power on the switch: Reconnect the previously removed power sources to the switch. The switch’s front-panel LEDs should indicate the status of the new connection. Check the LED indicator for the fiber port to ensure that it is operating correctly. Refer to the table of LEDs in this guide for a description of the LED indications. If the module does not respond, see “Troubleshooting” below.
More details concerning connection options and network applications can be found in the LION-24TP User Guide. Information on the module’s configuration options can be found in the Management Guide that is included with the base unit.
TROUBLESHOOTING
If you experience any problems with the module, check the following items before contacting Hirschmann’s Technical Support:
• Ensure the LION-24TP switch with the Gigabit
Ethernet Uplink Module is powered up.
• Ensure that the device attached to the module is powered up and operating correctly.
• Ensure that the module is properly seate d in the slot.
• Verify that the attached device is configured to match the communication mode used by the module (that is, 1 Gbps, full duplex).
• Check the connectors on both ends of the cable to be sure they are properly engaged. When attaching fib er cable to an SC-type port, be sur e the plug clicks into place to ensure that it is properly seated.
• Be sure the fiber terminator s are clean. You can clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened with a li ttle ethanol. Dirty fiber termina tors on fiber optic cables will impair the quality of the light transmitted through the c able.
Uplink Module LEDs
LED Condition Status
M1, M2 On/Flashing Amber Port has established a valid 10/100 Mbps network
connection. Flashing indicates activity.
On/Flashing Green Port has established a valid 1000 Mbps network
connection. Flashing indicates activity.
Off There is no valid link on the port.
RX
TX
Gigabit Uplink Module
LION-GIGA-1SX
Console
M1 M2
Power
M1
M2
Diag
157911
13
15
17
19
21
23
3
2
6
810
12
14
16
18
20
22 24
4
LION-24TP
Console
M1 M2
Power
M1
M2
Diag
157911
13
15
17
19
21
23
3
2
6
810
12
14
16
18
20
22 24
4
LION-24TP
RX
TX
Console
M1 M2
Power
M1
M2
Diag
157911
13
15
17
19
21
23
3
2
6
810
12
14
16
18
20
22 24
4
LION-24TP
RX
TX
GigabitUplinkModule
LION-GIGA-1SX
Page 2
150480-102 R01
01-0700
Hirschmann reserves the right to make changes in specificatio ns and other information contained in this document without prior notice. The reader should in all cases consult Hirschmann to determine whet her any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL HIRSCHMANN BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF HIRSCHMANN HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
© 2004 by Richard Hirschmann GmbH & Co., Germ any All Rights Reserved Printed in Taiwan, R.O.C.
Microsoft, Windows, Windows 95, Windows 98, Windows NT, and Windows XP are either trademarks or registered trademarks of Microsoft Corporation.
Netscape and Netscape Navigator are trademarks of Netscape Communications Corporation.
All other product names mentioned in this manual may be t rademarks or registered trademarks of their re s pective companies.
FCC NOTICE
This device complies with Part 15 of the FCC rules . Operation is subject to th e following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interfe r ence received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not in sta lled in accordance with the operator’s manual, may ca use harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to corre ct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance coul d voi d the user ’s authority to operate the equipment.
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique éd icté par le ministère des Communications du Canada.
EC CONFORMANCE DECLARATION
European contact: Richard Hirschmann GmbH & Co.
Automation and Network Solutions Stuttgarter Straße 45-51 72654 Neckartenzlingen, GERMANY
This information technology product complies with ISO/IEC Guide 22 and EN45014. It conforms to the following specificati ons:
EN55022(1988)/CISPR-22(1985) Class A EN50082-1: IEC 1000-4-2, 3, 4, 6
This information technology product complies wit h the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE Mark accordingly.
SPECIFICATIONS
Ports
1 1000Base-SX
Network Interface
SC connector
62.5/125 or 50/125 micron multimode fiber (MMF) cable
Size
10.0 x 7.2 x 2.5 cm (3.94 x 2.83 x 0.98 in.)
Power Consumption
2.04W maximum
Temperature
Operating: 0° to 50° C (32° to 122° F) Storage: -40° to 70° C (-40° to 158° F)
Humidity
Operating: 5% to 95%
Compliances
CE Mark Emissions
FCC Class A EN55022 (CISPR 22) Class A
Immunity
IEC 1000-4-2/3/4/6
Standards
IEEE 802.3z Gigabit Ethernet ISO/IEC 8802-3
CONNECTIVITY GUIDELINES
LION-GIGA-1SX
1000BASE SX-SC
GIGABIT ETHERNET
UPLINK MODULE
QUICK INSTALLATION GUIDE
01-0700
HIRSCHMANN
Only qualified personnel should perform installation procedures.
NOTICE
z
SAFETY WARNING
Before installing or removing the LION-GIGA-1S X , first di sconnect the switch from the main power supply. For full safety instructions, please refer to the user guide that acco mpanies the switch.
Warning:
Optical Safety for Fiber Optic Modules
When using a fiber optic media uplink module, never look at the transmit laser while it is powered on. Also, never look di rectly at the fiber TX port and fiber cable ends when they are po w ere d on.
Aver ti ssmen t:
Ports pour fibres optiques ­sécurité sur le plan optique
Ne regardez jamais le laser tant qu'il est sous tension. Ne regardez jamais directement le port TX (Transmission) à fibres optiques et les embouts de câbles à fibres optiques tant qu'ils sont sous tension.
Warnhinweis:
Faseroptikanschlüsse ­Optische Sicherheit
Niemals ein Übertragungslaser betracht en, während dieses eingeschaltet ist. Niemals direkt auf den Faser-TX-Anschluß und auf die Faserkabelenden schauen, während diese ein geschaltet sind.
Cable Types and Specific a tions
Cable Type Max. Length Connector
10Base-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45 100Base-TX Cat. 5 100-ohm UTP 100 m (328 ft) RJ-45 1000Base-T Cat. 5 100-ohm UTP or better 100 m (328 ft) RJ-45 100Base-FX 50/125 or 62.5/125 micron
multimode filber
Half Duplex 412 m (1351.4 ft) SC or ST Full Duplex 2 km (1.24 miles) SC or ST
10/125 single-mode filber 10 km (6.21 miles) SC or ST
1000Base-SX 50/125 or 62.5/125 micron
multimode filber
See the following table
SC or ST
1000Base-LX MMF or SMF See the following
table
SC or ST
1000Base-SX Fiber Specifications
Fiber Diameter Modal Bandwidth Range
62.5/125 MMF 160 MHz/km 2 - 220 m (7 - 722 ft) 200 MHz/km 2 - 275 m (7 - 902 ft)
50/125 MMF 400 MHz/km 2 - 500 m ( 7 - 1641 ft)
500 MHz/km 2 - 550 m (7 - 1805 ft)
1000Base-LX Fiber Specifications
Fiber Diameter Modal Bandwidth Range
10/125 SMF N/A 2 m - 5 km (7 ft - 3.2 miles)
Loading...