Hipers DSO-120, DSO-180, DSO-90, DSO-150, DSO-250 User Manual

...
FAR INFRARED RAYS HEATER
USER’S MANUAL
MODEL: DSO-90, DSO-120, DSO-150, DSO-180, DSO-210, DSO-250, DSO-350
Thank you for purchasing HIPERS Far Infrared Rays heater.
Please read this user’s manual carefully before you operate this heater.
It is recommended you to put this manual on where the user can  nd easily. It is obligatory that the user read “Notice for Safety“ carefully before using,
This heater is designed for your country only. If you use it in another country
you have to check the electricity  rst, and if the electricity condition is same you can use it.
Warranty card is enveloped in this manual. The contents (features & speci cations) in this manual are subject to be
changed without notice.
- 2 -
www.soojuskiirgur.ee
TABLE OF CONTENTS
NOTICE FOR SAFETY .................................................................. 3
STRUCTURE & DESCRIPTION .................................................6~7
• STRUTURE & DESCRIPTION FOR MODEL ...............................6
• CONTROLLER ...................................................................................6
• REMOTE CONTROLLER .................................................................7
HOW TO USE ..................................................................................8~10
• OPERATION & STOP ....................................................................... 8
• TEMPERATURE CONTROL ............................................................9
• SELF DIAGNOSIS FOR THE SAFETY DEVICE ...........................10
CLEANING & MAINTENANCE ..................................................11
DAILY CHECK POINTS & ADJUSTMENT .............................12~13
TROUBLE SHOOTING ................................................................. 14~15
SPECIFICATION & ELECTRICAL WIRING DIAGRAM......16
WARRANTY CARD .......................................................................17
- 3 -
STOVES & CHIMNEYS
NOTICE FOR SAFETY
This is for protecting the user’s safety, and preventing any property damage, please read carefully and follow the instruction on this manual.
It is classi ed as “Warning“, and “Caution“ by the contents.
WARNING: In case of misuse, it may cause a serious wounds or death. CAUTION: In case of misuse, it may cause a slight injury or property damage.
Meaning of symbol
Forbidden Obligatory
WARNING
Use AC 220/23 0V(50Hz) p ower supply only, otherwise.
(it may cause a  re or an electric shock.)
Use the p roper form of fuse. Other wise
(it may cause malfunctioning or a  re.)
In case o f cleaning you must take out th e plug from the out let, wait unt il the heated f urnace is coole d down su ciently.
(Other wise, it may cause an electric shock or a burn)
Put a plug into the outlet tightly after removing any dirt on the plug.
(It may cause emitting smoke or a  re by ele ctrical short.)
It is dan gerous to turn OFF this heat er by taking out the p ower plug.
(It may cause a malfunction or electrical shock. Please turn OFF using RUN/STOP button.)
Put a plug into the outlet tightly with Eart h(-) only.
(It may cause an electric shock)
Do not us e a damaged power cord or plug, a nd a loose o utlet.
(It may cause short,  re, a shock.)
Do not fo ld the power cord hardly, or put a heavy material on it.
(It may be damaged on the covering material which might cause a  re, or an electric shock.)
Do not ta ke out the plug wi th holding th e cord or by the wet h ands.
(It may cause a  re or an electric shock)
Do not pl ace any in ammabl e material nea r the heater including c urtain, carpet, pape r, match, clothes, etc.
(It is exposed to danger of  re.)
Do not ex tend the powe r cord with conn ecting anoth er cable in the m iddle.
(It may cause a  re or an electric shock)
Do not pl ace or use any in ammable near the heater including f uel, gas, thi nner, benzene , spray, solven ts, volatile o rganic compo unds, etc.
(It is exposed to danger of  re or explosion.)
Place this manual noticeably near the heater so that, if necessary, the user can always  nd it easily.
- 4 -
www.soojuskiirgur.ee
NOTICE FOR SAFETY
WARNING
You must vent ilate well while you are usin g the heater, and do not use it in t he stu y area w here the vent ilation is not possible.
(You need to ventilate with f resh air 1~2 times per hour) (In case of incomplete combustion due to the lack of oxygen carbon monoxide can be increased to cause an accident from poisoning.)
It is dan gerous to use t his heater for a l ong time in the clo sed room or in ca se there are children or th e old and t he weak.
(It is recommended that the user open the windows to let fresh air in the room if the room is stu y.)
It is dan gerous to put yo ur hands or any other thing into the grill or furnace, or to apply a considerable shock o r force to the hea ter.
(It is exposed to  re, burn, or electric shock)
Do not pl ace any in ammabl e vinyl or plast ic goods o n top of heater, or cover the heater grill with clothes.
(It is exposed to  re or burn.)
Do not pl ace any electr ical item or heav y material on top of heater.
(It may cause malfunctioning or electrical shock, or if the heav y material is fallen user can be injured)
Do not to uch any of the heat ed material su ch as grill, furnace, etc.
- While the heater is operating or just af ter extinguish­ing the grill and furnace are hot, so do not touch any of those parts (Espe cially pay attention more to keep children away from the hot materials)
- It may cause a burn.
Do not move or transpor t during operation.
(It may cause a  re or a burn) (In case of m oving this heater you must turn OFF take out power plug before you move it)
It is rec ommended not to use this heater in the highly elevated areas.
(Do not use this heater in the areas where is higher than 1,500 m from the sea level.) (You need f requent ventilation in the areas of 700 ~
1,500m from the sea level.) (Due to the lack of oxygen, carbon monoxide can be
increased to cause an accident from poisoning.)
Do not us e this heater fo r another pur pose other than heating.
(Do not use this heater for dr ying clothes because it may cause a  re.) (Do not use this heater for keeping pet animal or plants warm)
Pay atte ntion to avoidin g water into the h eater
during cleaning.
(It may cause a  re or electric shock)
Do not op erate this hea ter while you are sleeping.
(Due to no ventilation while you are sleeping the room easily get stu y, and lack of oxygen.)
Do not us e this heater on t he unstable p laces.
(Do not use this heater on an inclined surf ace or a shaking support.) (This heater may fall down, which cause a  re or malfunction.)
Place this manual noticeably near the heater so that, if necessary, the user can always  nd it easily.
- 5 -
STOVES & CHIMNEYS
NOTICE FOR SAFETY
CAUTION
In case o f storing this h eater, be sure that you store it in the d ry places ind oor instead of h ot and humid environment.
(Other wise, it gets rusty or goes into trouble)
You must take o ut the plug fro m the outlet , if there
is a  as h of lightenin g or thunder or yo u don’t use it for a long time.
(Other wise, it is exposed to the danger of electrical shock, short circuit or a  re.)
If the su pply cord is damaged, it mus t be replaced by the man ufacturer or its service agent or simi­larly quali ed person in order to avoid a ha zard.
Call you r local after s ales servi ce agent in case t he power co rd is damaged.
(Other wise, it is exposed to the danger of electrical shock, short circuit or a  re.)
Do not pu t this heater on u nstable sur face of groun d such as inclin ed or bumpy.
(The heater may not work p roperly.)
Do not sh ower water to the h eater direc tly, nor use benze ne, thinner, alcohol for cle aning.
(Other wise, it is exposed to the danger of electrical shock, short circuit or a  re.)
Do not pu t an excessive physical shock t o the re­mote controller, nor d isassembl e it arbitraril y.
(it arbitrarily.)
Do not op erate this hea ter in the place w here it
gets we t by the humid such as bathroom .
(It may cause an electrical short circuit or an elec trical shock accident)
TIPS BEFORE INSTALLATION ...
1. Make sure the safety in the place where you wish to use this heater. The ground surface and surrounding should be plain
and non- ammable, and solid.
You need to have su cient space surrounding the
heater at least 15cm from the wall and the left & right side, at least 1 m distance from the ceiling and the front side without any obstacle.
You need to use exhaust duct in case of operating in
small spaces. (Recommended Duct speci cation: 75mm (Diameter) x 5meter long-aluminum duct) (Be sure there must not be rain drops into the exhaust duct end.) (You must ventilate frequently with fresh air by opening window or fan.)
You must put an extinguisher beside the heater. There must not be direct sun light, excessive heat
near the heater.
After you  x the installation, lock the caster for
avoiding unexpected movement.
Do not use this heater near fabric curtain, carpet or
plastic or vinyl curtain which may cover the heater in case of falling down by the wind or by any physical force, which may cause a  re.
The heater must not be located immediately below a
socket-outlet.
Positioned so that the plug is accessible.
2. You must use Diesel or kerosene as fuel. If you use other fuel, it may cause an excessive soot or
trouble of malfunction.
In case of refueling make sure the heater is turned
OFF.
To be made by the manufacturer or his service agent
who should be contacted if there is an oil leakage.
Regulations concerning the disposal of oil when
scrapping the appliance have to be followed.
3. The proper electricity is 220/230V, 50Hz. It will be applied and adjusted as per customer’s request. You must supply power as per its requirement only once it
is adjusted.
- 6 -
www.soojuskiirgur.ee
STRUCTURE & DESCRIPTION
STRUCTURE & DESCRIPTION FOR MODEL
CAUTION
This design may be changed for improvement of effi ciency
Exhaust Duck/Safety Grolle
Wheel
Control Panel
Heating Tube
Combustion furnace
Front Safet y Grille
Control
Overheating sensor
Fuse
Burner department
Circulation Fan
Conduction Sensor
Fuel Guage
Fuel inlet
Temper atur e Senso r
Fuel Filter
1. LED DISPLAY
It displays the status of temperature, time, operation,
and error, etc.
2. ON/OFF
3. TEMP SELECT BUTION
To select temperature control mode
4. TIME SELECT BUTION
To select time control mode
5. UP/DOWN
To set or change the temperature or time
6. IR RECEIVER FOR REMOTE CONTROLLER
7. OFF TIMER
To select whether off timer mode is operated or not.
- 7 -
STOVES & CHIMNEYS
- When heater turns o , the moter (to cool heater) is operated.
- It is dangerous to turn OFF this heater by taking out the power plug. It may cause a malfunction or electrical shock. Please turn OFF using RUN/STOP button.
- If malfunction cause with power down, this case is in a consumer cost.
STRUCTURE & DESCRIPTION
REMOTE CONTROL
1. ON/OFF
When heater tums ON or OFF, you can this but ton.
2. OFF TIMER
Every time you press this button, heater repeat set-up and cancel.
3. TIME SELECT BUTTON
To select time control mode
4. TEMP SELECT BUTTON
To select temperature control mode
5. UP/ DOWN
To set or change the temperature or time
Connect power cord of heater with outlet. When you connect power plug, current temperature is displayed.When you press UP/DOWN button. the desired temperature is displayed. You can set the desired temperature between “0-40°C“ (1 °C per a press)
CAUTION
- 8 -
www.soojuskiirgur.ee
HOW TO USE
OPERATION & STOP
1. CONNECT POWER PLUG (You can see current temperature) THEN, PRESS ON/OFF BUTTON
(You can check “set tem/time“-the number of right side) But, if this heater operate in case  rst use from purchase, turn Air Screw left around three times and then start with pressing “ON/ OFF“ switch. Heater will be turned ON with “beep“ sound, and
automatically operated. Fasten the air screw after 4 seconds.
If “E1“ error is displayed, press “ON/OFF“ switch one more time.
2. SELECT THE DESIRED OPERATION TYPE USING “TEMP or TIME“ BUTTON.
3. Set the time or temperature by pressing “Temp select button“ or “Time select button“.
- “Temperature“: You can set the desired temperature between “0~40°C“
- “Time“: Set the desired time limit between “10~25min“ (5min per a press)
Tip
• In order to be operated, the setting temperature should be higher than current temperature.
• After power On, the default mode is temperature control mode.
• During the operation if you push On/O button, the heater is stop and the o timer function is cancelled.
Circulation Fan operate in a minute after turning on heater and stop in two minutes after turning o heater. (This fan is for circulating heat and for cooling heater)
The model equipped “solenoid valve (by-pass device) makes the remaining oil returned to the oil tank. For 10sec. from the time of
burner o , the solenoid valve is operation, which makes remaining oil returned to the oil tank , and by this device, the smell caused by unburned gas are remarkably shrunk.
Cur Temp
Cur Temp
Set Temp/T ime
Set Temp/T ime
- 9 -
STOVES & CHIMNEYS
HOW TO USE
TEMPERATURE CONTROL
1. Push On/O button. 2. By pusing Temperature button, please select Temperature control mode.
• At that time, Temperature control lamp is lighten.
3. By pushing ““ button, please select desire temperature.
• The set ting range: 0~ 40 °C
• The default value: 25°C
• During the time you push or , the setting temperature is
increased/decreased very fast.
• The range of current temp display –9~50 °C
4. During operaton, the current temp. and setting temp. both are displayed, and if you push On/O button and make the operation stop, only current temp. is shown.
5. When the setting temp. is higher 2 °C than current temp., it star ts operation, and the setting temp. is less than 1 °C
than current temp., the operation is stop.
• Current temp. < Settin g temp. … Opeartion (+2°C)
• Current temp. > Setting temp. … Opearation stop (-1°C)
Tip
• The current temp is less than -9°C(16° F), the dispaly of the temp. is ‘LO’, and more than 50°C(99° F) it dispalys as ‘HI’ (50°C is not same value as 99° F, actually 37°C is same value as 99° F)
• The set ting temperature is increased/decreased 1 °C by pushing of (/ ) button, if you push the button more than for 2sec. the value is increased/decreased 1 °C in 0.2 sec.
• If you push and  button for 5sec. simultaneously, the unit is converted from °C to °F or from °F to °C (The defaulte unit is °C)
This mode enables the user set the desired temp era­ture, and once it is fi xed this heater work s automati­cally with running and stop repeatedly to meet this temperature. (If power ON and Heater starts operation, the temper­ature control mode will be operated as default.)
- 10 -
www.soojuskiirgur.ee
If the following error or trouble signs are displayed on the operation panel
Displayed messages
Discription of
troubles
Items to check and required actions
E1. No ignition The burner is mis red
- The lack of fuel
- There is Air in the fuel tube (Air Discharge)
- Phototube pollution (Cleaning)
E2. Phototube
(Flame sensor)
Phototube troble
Detrction of residual
 ame
- Unpluged Phototube (→plug), Phototube Trouble (→exchange)
- If the heater is stopped just after ignition, there is re­sidual  ame (No damage Re-operation)
E3. Temperature sensor
Temperature sensor
trouble
- Check if the temperature sensor connector is loosened. (Firmly connect the connector if it is loosened)
E4. Overheat sensor Product is overheated
- Check if there are any bump signs inside the burner. (Ask the survice)
- Check if the overheat protector wire is disconnected (Operate the heater again after connecting the wire)
E5. Slope Tile of heater
- Check if the heater is moved (Tilt may occur when the heater is shaken or moved. Operate the heater again)
- Inversion switch wire is disconnec ted (Operate the heater again after connectong the wire)
E6. Lack of fuel Lack of fuel
- Refuel (→ Re-operation)
Hi
Tem per atu re
is above 50 °C
- Check if the tempatature sensor is installed inside. (Install the sensor outside)
- If the troubles E1 - E6 occur, check the causes and take the required action. If you press the Power Button twice, you may restart the heater
If the troubles persist even after taking the actions as slanted in the below table, ask the survice
Troubles Items to check Required action
All lamps of operation panel are turned o
- Power failure
- Power plug is unpluged
- Fuse burns out
- Ühendage pistikupessa
- Vahetage sulavkaitse välja
Lamp si repeatedly turned o
and turned on
- Selec t the time (check the lamp) - Seadistage temperatuur
The heather is operated as no
indication of oil stu
- Flowmeter wirning is unpluged - Ühendage juhe
Something burning smells during the initial operation
- Foreign substances are burnt inside the gasket - Põlemise lõhn kaob 1–2 tunni järel
The fuel smell is unusual
- There is amell when the heater is stoped as soon as starting
- On oil supply, spilling fuel
- Laske 15minutit töötada
- Eemaldage lekkinud õli
Room temperature is higher
than normal one
- Check if the location of temperature sensor (it may occur if the sensor is installed inside.)
- Fix the sensor at the correct posion
HOW TO USE
ITEMS TO CHECK BEFORE INFROMING OF TROUBLE
- 11 -
STOVES & CHIMNEYS
To store the heater, cool down the heater and plug out and wrap with plastic cover and keep in the well air- owing place.
- You’d better consume all oil not to remain in.
CAUTION
To keep heater in outdoor or humidity place is major cause of problem.
CLEANING & MAINTENANCE
CLEANING & MAINTENANCE
STORING
To pull out the fro nt grille, please raise a lit tle and pull it out (Assemb ly is opposition way.)
In case that you keep the heater for a long time and you want to maintain it in clean status, please power o and cool
down the heater, and pull out the plug as the above picture and clean according to the following instruction.
• Please pull out the front grille by raising it and pull it out to the front.
• Please clean the heating re ection which is in the back side of heater and burner area.
(The burning pipe is coated by ceramic material so careful clean not to damange to the coating.)
DO NOT DISASSEMBLE THE BURNING PARTS.
• Please wipe out the front controller area with soft wool.
• After  nishing of cleaning, please assemble the front grille to the heater
- 12 -
www.soojuskiirgur.ee
CLEAN OF FLAME SENSOR (Cds)
- If the detection part of CdS is contaminated by soot or other dirt, the performance can be lowered and it may cause a problem.
- Please take out CdS carefully which is placed in lower part of burner.
- Please clean the detection part of CdS by soft clothes.
- Please be sure CdS is  xed correctly.? (Mark “A“ should be inserted fully.)
CLEAN OF COMPONENTS
- In case you need to change components, please contact us.
- In case repair or exchange of components, please contact the service center operated by our distributor or head o ce
- Do not try to repair this heater by non-licensed service personnel, because it may cause a worse condition, so please contact local service center, or distributor that is designated by our company.
DAILY CHECK POINTS & ADJUSTMENT
DAILY CHECK POINTS
Soft clothes
- 13 -
STOVES & CHIMNEYS
IN CASE OF SUDDEN STOP DURING OPERATION
- Please check if now is operating in the time control operation.? If so, the heater can be rest for 5min.
- Please check if now the setting temp. is less than the current temp.
- Please check if the heater is stop by pressing On/O switch by remote controller or front controller.
- Please check if the heater is stop by sleep timer function.
- Please check if the heater is stop by auto-self-checking.
AIR FLOW-OUT
In case that Electric pump so noisy and burner no ignition, main cause of the problem is air  ow into the electric pump
and not distribute oil. If oil is all consumed without remaining in the tank, air can be  ow into inside electric pump.
- The method to  ow-out air
Operate the heater When the electric pump operated, turn on the air out ow screw to counter-clockwise. And you wait till air  ow out
and oil start to come out.
When you see oil start to come out, turn o the air out ow screw to clockwise
(In case much air inside, please repeat same way 2~3times.)
DETAIL OF BURNER STRUCTURE
- When you contact service person with a problem, please refer the below detail structure of the burner.
DAILY CHECK POINTS & ADJUSTMENT
ADJUSTMENT
FUSE(BLZND)
IGNITER
BURNER MOTER
FLAME SENSOR (phototube)
AIR SCREW
FUEL INLET
TRANSMIT PREVENT SENSOR
FUEL RETURN HOSE
AIR RELEASE SCREW
ELECTRONIC PUMP
FUEL LINE
AIR SUCTION HOLE
FLOWMETER
OVERHEATING SENSOR
- 14 -
www.soojuskiirgur.ee
TROUBLE SHOOTING
PROBLEM CAUSE SOLUTION
NO OPERATION
No Power supply?
Check the power supply is proper. (ex. 220/230V a.c. 50Hz)
Check power plug is disconnected
Power plug into the outlet
Is the Fuse short? Replace fuse with new one (250V a.c. 3.15A)
NO FAN MOTOR
OPERATED
“Lack of Fuel“ light ON ? Lack of Fuel
Fill it up with Kerosene or Diesel Do not mix or use together these two dif­ferent fuel.
Is set temp. lower than current temp.?
Set the temp as higher than current temp.
Mis re lamp ON?
Air in the electric pump.
Remove the air in the electric pump. (Refer to page 19)
Overheating Lamp ON?
Under operation of overheating prevention
Ventilate with fresh air in the room, and turn OFF the heater for a while (Refer to page 16)
Inclination display lamp ON?
Ground surface is in­clined or not plain
Replace the heater in plain ground (Refer to page 16)
Can you see“Er2“ on the display?
Error on Temperature sensor
Select Timer control operation from tem­perature control mode. (Refer to page 16)
NO IGNITION
ON BURNER
Is fuel  lter stu y? Filter is contaminated
Clean the  lter with compressed air, or re­place with new one. (Refer to page 18)
Is air suction valve adjusted excessively or too small?
Call after sales service agent.
Voltage is low? In case of low voltage
Burner will not work properly, so use a booster to elevate voltage. (A/S)
Please check below points before you think trouble has been occurred.
Is Power ON? Is Fuel enough? Is Flame sensor clean?
- 15 -
STOVES & CHIMNEYS
TROUBLE SHOOTING
PROBLEM CAUSE SOLUTION
IMMEDIATE
STOP JUST
AFTER IGNITION
“Lack of Fuel“ light ON? Running out of fuel Fill up the fuel.
Check if the fuel is Diesel or kerosene
It may cause less per­formance & trouble
Drain the existing fuel, and  ll with Diesel or kerosene only.
Water or any other impurities on fuel?
It may cause less per­formance & trouble
Replace the fuel with good quality one.
Is  ame sensor located well?
In di erent position, it causes an error.
Place the sensor in original location.
Is  ame sensor dirty?
Error because of soot or dirt
Call after sales service agent.
Noise in fuel pump?
Excessive air in the pump and nozzle.
Remove the air in the electric pump.
EXCESSIVE
SOOT IS
GENERATED
Check if the fuel is Diesel or kerosene
It may cause less per­formance & trouble
Drain the existing fuel, and  ll with Diesel or kerosene only.
Water or any other impurities on fuel?
It may cause less per­formance & trouble
Replace the fuel with good quality one.
Is air suction valve adjusted excessively or too small?
Error on Temperature sensor
Call after sales service agent.
Is tube clogged?
Smoke may  ow backward
Clean the tube by removing soot inside of tube, or replace with new one.
NOISE IN
BURNER
Is Fuel  lter stu y?
Dirty  lter with impurities and contamination.
Clean or replace with new one
Noise in fuel pump?
Excessive air in the pump and nozzle.
Remove the air in the electric pump.
- 16 -
www.soojuskiirgur.ee
SPECIFICATION & ELECTRICAL WIRING DIAGRAM
Model DSO-90 DSO-120 DSO-150 DSO-180 DSO-210 DSO-250 DSO-350
Fuel Green Diesel Green Diesel Green Diesel Green Diesel Green Diesel Green Diesel Green Diesel
Heating Output (kcal/h)
9,000 12,000 15,000 18,000 21,000 25,000 35,000
Calori c power (kW) 10.4 14.0 17.4 20.9 24.4 29.0 40.7
Fuel Consumption (l/h) 1. 0 1.2 1.5 1.9 2.1 2.3 3.8
Heating Area 36–53m² 55–88m² 66–133m² 86–196m² 135–237m² 166–280m² 231–330m²
Electric Power Consumption
50W 50W 50W 65W 65W 115W 120 W
Size (WxDxH)
740 x 320
x 1020
940 x 320
x 1020
1290 x 320
x 1020
1290 x 320
x 1190
1290 x 320
x 1190
1340 x 350
x 1510
1370 x 400
x 1800
Weight 42kg 45kg 60kg 63kg 63kg 90kg 116 kg
Used Heating Heating Heating Heating Heating Heating Heating
Power Supply
220V /
50Hz AC
220V /
50Hz AC
220V /
50Hz AC
220V /
50Hz AC
220V /
50Hz AC
220V /
50Hz AC
230 V / 50
Hz AC
Tank Capacity 28L 30L 45L 45L 45L 85L 90 L
Diameter of Somke Pipe (in case of Using)
90mm 100mm 100mm 100mm 100mm 100mm 100mm
Black
Black Black
Black
BR
White
Green
AC 220 V Overheating
Sensor
Conduction Switch
Flowmeter Temperature
Sensor
Green GreenYello w
Yello w
Brown
Brown
Yellow Black 2P Gray 2P
Red
Flame Sensor
Ignition Trans
Fan Motor
Electronic Lamp
- 17 -
STOVES & CHIMNEYS
WARRANTY CARD
This HIPERS far infrared rays heater gives you more reliable performance and comfortableness, and durabil­ity the more you use it, because it is produced under the strict quality assuarance system including various inspection during production and after production and reliance test, etc. In case you encounter any problem, please contact the local service agent, or a distributor. If the problem is occurred due to the production failure, or natural malfunctioning, we will o er you free repair service under our warranty clause.
GENERAL
1. Warranty period is 36 months after purchasing date.
- If the problem is occurred by the mistake or misuse of the customer, we charge a repair cost even if it is within warranty period.
2. This warranty card is valid within your country.
3. Please keep this warranty card for better service in case of trouble.
4. Please contact your local distributor or after sales service agent.
5. Please  ll out this form after purchase.
DESCRIPTION HIPERS Far Infrared Rays Heater
MODEL DSO-90 / DSO-120 / DSO-150 / DSO-180 / DSO-210 / DSO-250 / DSO-350
DATE OF PURCHASE PRODUCT
WARRANTY PERIOD ( ) Months PRICE
DISTRIBUTOR
NAME OF COMPANY
TELEPHONE NO.
CUSTOMER
NAME
ADDRESS
TELEPHONE NO.
O cial representative of Hipers in Scandinavia and Baltic states:
Veltron International OÜ (Velt Ekspert)
Tel.: +372 5648 8805
E-mail address: info@veltekspert.ee; hanno@soojuskiirgur.ee
Address: Pärnu mnt.139/11, Tallinn, Estonia
Manufacturer: Daesung Hione Co,. Ltd Made in Korea
O cial representative of Hipers in Scandinavia and Baltic states:
Veltron International OÜ (Velt Ekspert)
Tel.: +372 5648 8805 E-mail address: info@veltekspert.ee; hanno@soojuskiirgur.ee Address: Pärnu mnt.139/11, Tallinn, Estonia
Loading...