- 5 -
STOVES & CHIMNEYS
NOTICE FOR SAFETY
CAUTION
In case o f storing this h eater, be sure that you store
it in the d ry places ind oor instead of h ot and humid
environment.
(Other wise, it gets rusty or goes into trouble)
You must take o ut the plug fro m the outlet , if there
is a as h of lightenin g or thunder or yo u don’t use
it for a long time.
(Other wise, it is exposed to the danger of electrical
shock, short circuit or a re.)
If the su pply cord is damaged, it mus t be replaced
by the man ufacturer or its service agent or similarly quali ed person in order to avoid a ha zard.
Call you r local after s ales servi ce agent in case t he
power co rd is damaged.
(Other wise, it is exposed to the danger of electrical
shock, short circuit or a re.)
Do not pu t this heater on u nstable sur face of
groun d such as inclin ed or bumpy.
(The heater may not work p roperly.)
Do not sh ower water to the h eater direc tly, nor use
benze ne, thinner, alcohol for cle aning.
(Other wise, it is exposed to the danger of electrical
shock, short circuit or a re.)
Do not pu t an excessive physical shock t o the remote controller, nor d isassembl e it arbitraril y.
(it arbitrarily.)
Do not op erate this hea ter in the place w here it
gets we t by the humid such as bathroom .
(It may cause an electrical short circuit or an elec trical
shock accident)
TIPS BEFORE INSTALLATION ...
1. Make sure the safety in the place where you wish to use
this heater.
The ground surface and surrounding should be plain
and non- ammable, and solid.
You need to have su cient space surrounding the
heater at least 15cm from the wall and the left & right
side, at least 1 m distance from the ceiling and the
front side without any obstacle.
You need to use exhaust duct in case of operating in
small spaces.
(Recommended Duct speci cation:
75mm ⌀ (Diameter) x 5meter long-aluminum duct)
(Be sure there must not be rain drops into the
exhaust duct end.)
(You must ventilate frequently with fresh air by
opening window or fan.)
You must put an extinguisher beside the heater.
There must not be direct sun light, excessive heat
near the heater.
After you x the installation, lock the caster for
avoiding unexpected movement.
Do not use this heater near fabric curtain, carpet or
plastic or vinyl curtain which may cover the heater in
case of falling down by the wind or by any physical
force, which may cause a re.
The heater must not be located immediately below a
socket-outlet.
Positioned so that the plug is accessible.
2. You must use Diesel or kerosene as fuel.
If you use other fuel, it may cause an excessive soot or
trouble of malfunction.
In case of refueling make sure the heater is turned
OFF.
To be made by the manufacturer or his service agent
who should be contacted if there is an oil leakage.
Regulations concerning the disposal of oil when
scrapping the appliance have to be followed.
3. The proper electricity is 220/230V, 50Hz. It will be
applied and adjusted as per customer’s request. You
must supply power as per its requirement only once it
is adjusted.