Hi-Par HP1000E, HP315E Control, HP600E Control Control User Manual

Data is based on operation of a standard double ended HPS/MH lamp. Supply power is based on typical commercial 240V,50/60Hz.
Note: When the controller is connected the CONTROL indicator LED ashes 2 times every 2 seconds - indicating controller is functioning correctly. However, if the Connect Link Cable is removed during operation the ballast will shut down after 3 minutes. When operating ballast without a HI-PAR Control Station the CONTROL indicator LED will be o. Turn power o and on to reset the ballast when either connecting or disconnecting the Control Station.
BOX CONTENT:
1. Digital Ballast
DE lamps ONLY
6. OUTPUT to HPS or MH lamp
2. Power Cord
3. Magnet Ring
4. Power Input
8. Connect
Link Cable
Performance
Model
HP1000E Control
Model
Voltage
(V)
Max Input
Power
(W)
Maximum
Current
(A)
Power Factor
(COSθ)
Working
Voltage
(V)
Ignitor
Voltage
(kV)
240V 1185
THD
<10% 5.0 .97 215-265 4.0
USER MANUAL
HP1000E Control for DE HPS and MH lamps
Installation Directions
5. Rubber Feet
STATUS
LED
Output lock down Output errors Low input voltage Over temperature High input
1 Flash 2 Flash 3 Flash 4 Flash 5 Flash
MIN
MAINS POWER
1116 1016
761 602
MAX
1185 1085
830 671
BOOST
100%
75% 60%
MIN
LAMP POWER
1066
966 716 566
MAX
1135 1035
785 635
BOOST
100%
75% 60%
7. Dimming Knob
Physical Data
Length
(mm) Model Width (mm) High (mm) Colour Material
Weight (kgs)
338 HP1000E Control 166 96 Black Aluminium 4.0
WARNING: This manual contains important safety that should be followed during the installation and maintenance of the product. Please read this manual thoroughly before attempting to install or operate this product.
1. Before any assembly or maintenance, make sure the power supply is turned o.
2. To ensure safe system operation, only use certied light shades, cords, and
lamp sockets which match a national or international safety standard.
3. Lamp must be operated a distance away from any ammable substance.
4. Do not cover the digital ballast without proper heat sinking; doing so may aect
the normal case temperature (tc) of the digital ballast. Improper heat dissipation may shorten ballast life and void the warranty. tc=70oC/158oF.
5. Product is for indoor/enclosed use only; it must be protected from water/liquids.
6. Ensure proper mounting and installation of the digital ballast; it must be securely
fastened to a xed substrate to protect it from detachment, impact and excessive vibrations. If not secured, damage to the unit or persons may result.
7. Please ensure the input power matches with the specications of the digital Ballast. If you are not clear about the electrical source, please contact your power utility company, an electrician or your local distributor.
8. Install the power cord so it can not be pinched, stepped on or tripped over; secure cord and digital ballast properly to avoid lighting interruptions/hazards.
9. If the power cord needs to be extended, please make sure it meets the standard electrical safety requirement; the wire diameter should be at least 1.5mm² or 16AWG. Not following electrical code may result in re or other accidents.
10. To avoid the risk of shock or re, and as to not void the Warranty, do not open or disassemble the digital ballast.
11. If you have any questions on the installation of the digital ballast, or should you experience any trouble please contact your local authorised HI-PAR dealer.
Connecting the Ballast
- Please refer to the included wiring diagram for proper wiring connection.
- Only use the provided cables to connect the ballast to the power supply/socket.
- Insert recommended HPS/MH lamp into lamp socket.
- Ensure lamp type is correct orientation.
- Do not use an external ignitor.
- Lamps with auto-ignitor will not work with the digital ballast.
- Connect the ballast into the Hi-PAR Control Station.
Ignitor Safe Protection
The Digital Ballast will ignite automatically. During this period, the ballast can protect itself without manual intervention. If HPS lamp does not work after 5 minutes (For MH, at most 15 min), please check the connection or change the lamp.
User Guide
This product must be equipped with the right High Pressure Sodium lamp (HPS) or Metal Halide lamp (MH) to get the highest eciency, safety, and luminance output from the lamp.
Connecting the Ballast to the HI-PAR ‘Control Station’ (controller - sold separately)
- Control Station communicates with ballast via TRS (Stereo) cable
- Multiple ballasts can be installed in ‘daisy-chain’ arrangement
- Up to 200 Ballasts per zone, two zones per Control Station
- Control Station and Thermo Sensors regulate timing and dimming control
CONTROL STATION Compatible - Plug and Play Linkable 400 Fixture - 200 Ballast on each channel
ZONE A
THERMO SENSOR
POWER
THERMO SENSOR
UP TO
200
BALLASTS
UP TO
200
BALLASTS
ZONE B
www.hi-par-horticulture.comwww.hi-par-horticulture.com
Loading...