![](/html/a1/a1f5/a1f5b7ea0fd515932a4f59a9344252fa7e0f7622a9933cc6883d9de4955a5d38/bg1.png)
HIOTH User Manual
HIOTH TECHNOLOGY CO.,LTD.
PIR MOTION DETECTOR
Introduction
The Motion Detector is a Z-Wave enabled device which is fully compatible with any Z-Wave
enabled network. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it
regardless of the manufacture, and ours can also be used in other manufacturer’s networks, This
Motion Detector can control our modules via controller settings. Inclusion of this Motion Detector
on other manufacture’s Wireless Controller menu allows remote turn on of connected modules when the detector is triggered.
The Motion Detector is designed with two detecting sensors, Passive Infra Red (PIR) sensor
and light sensor, in order to fulfill the purpose of security and home automation. Once night falls,
the percentage of ambient illumination is lower than preset value. If a person moves within or
across the device field of vision, a trigger radio signal will be transmitted so as to turn on the connected lightings for better illumination.
CT-SMZW2004-ES
PIR Motion Detector
![](/html/a1/a1f5/a1f5b7ea0fd515932a4f59a9344252fa7e0f7622a9933cc6883d9de4955a5d38/bg2.png)
HIOTH User Manual
HIOTH TECHNOLOGY CO.,LTD.
Technical Information
Compatible with any Z-Wave network controller
Battery powered and cost savings
Support the scene control
Specifications
Radio protocol: Z-Wave 868.42MHz EU
Power supply: DC 4.5V(1.5V AA*3)
RF range:25m (in an open area of the wireless controller and the latest line-of-sight between
Z-Wave receiving module)
Operation Frequency: 908.42 MHz (SP814-2) / 921.42 MHz (SP814-9)
PIR Detection Coverage: Wall-Mounted:
Up to 10m x 110 ° (at 1.8m mounting height& 25 ° C)
Ceiling-Mounted:
Up to5m x 360 ° (at2.8m mounting height& 25 ° C)
Dimension:85 mm x 85 mm x 45 mm
Operation
NOTE:
① Lens Cover
② Photocell Sensor
③ PIR Sensor
④ Two-Color Indication LED(red & green)
![](/html/a1/a1f5/a1f5b7ea0fd515932a4f59a9344252fa7e0f7622a9933cc6883d9de4955a5d38/bg3.png)
HIOTH User Manual
HIOTH TECHNOLOGY CO.,LTD.
⑤ Link Key
Fig.1
Z-WAVE NETWORK INCLUSION
In the rear casing, there is a link key which is used to carry out inclusion, exclusion, association
or reset. When the detector is first powered up, the LED flashes on and off alternately and repeate
dly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with
Z-Wave enabled devices.
1) Connect the power supply, and make sure that device in a state of "No node ID" (2-second
on, 2-second off).
2) Choose "Z-Wave" to enter the Network Inclusion mode on the APP, then click " ".
3) Pressing link key 3 times within 1.5 second (Detector beeps when link key is pressed.).
4) When prompt a message “Request Access Success”, please go to the device list interface, and
refresh the device list, the device will be displayed.
Z-WAVE NETWORK EXCLUSION
1) Make sure the device is connected to the power supply.
2) Remove the device on the APP, then click "finish".
3) Pressing link key 3 times within 1.5 second (Detector beeps when link key is pressed.).
4) Please go to the device list interface, and refresh the device list, the device will not be
displayed.