1 Specications 3
1.1 RS-232CSpecications ................................................................................................3
Handshake (About Buffer Flow Control) ...............................................................................................3
1.2 GP-IBSpecications .....................................................................................................4
1.3 USBSpecications .......................................................................................................4
1.4 LANSpecications .......................................................................................................4
2 Connection and Setting 5
2.1 Overview of Communication ........................................................................................5
Screen Displayed while Setting Interfaces ........................................................................................... 6
2.2 USBSettingsandConnection .....................................................................................7
Setting USB ..........................................................................................................................................7
Connecting the USB Cable ................................................................................................................... 8
2.3 LANSettingsandConnection .....................................................................................9
LAN Settings .........................................................................................................................................9
Connecting a LAN Cable .................................................................................................................... 13
2.4 GP-IB Connection and Settings
(whentheZ3000isconnected) ..................................................................................14
Connecting the GP-IB Cable .............................................................................................................. 14
Setting GP-IB ......................................................................................................................................14
2.5 RS-232CConnectionandSettings
(whentheZ3001isconnected) ..................................................................................16
Connecting the RS-232C Cable ......................................................................................................... 16
Setting RS-232C .................................................................................................................................17
2.6 Remote Mode ...............................................................................................................18
Canceling Remote Mode .................................................................................................................... 18
Appendix A1
Appx.1 CheckingtheUSBVirtualCOMPort A1
IM7585A987-02
10
9
8
7
6
5
4
3
2
1
付録索引
Contents
ii
1
Introduction
Introduction
This instruction manual provides details on the communication interfaces of the IM7580A series, IM7581 series, IM7583 series, IM7585 series and IM7587 series Impedance Analyzer. In this document, the “instrument” means the IM7580A series, IM7581 series, IM7583 series , IM7585 series and IM7587 series.
Safety Information
This manual contains information and warnings essential for safe operation of the instrument and for maintaining it in safe operating condition. Before using it, be sure to carefully read the following safety precautions.
Notation
In this manual
,
the risk seriousness and the hazard levels are classied as follows.
WARNING
Indicates a potentially hazardous situation that may result in death or serious injury to the operator.
CAUTION
Indicates a potentially hazardous situation that may result in minor or moderate injury to the operator or damage to the instrument or malfunction.
IMPORTANT
Indicates information related to the operation of the instrument or maintenance tasks with which the operators must be fully familiar.
Indicates prohibited actions.
Indicates the action which must be performed.
*
Indicates the action which must be performed.
[ ]
Menus, commands, dialogs, buttons in a dialog, and other names on the screen and the keys are indicated in brackets.
CURSOR
( Bold character)
Bold characters within the text indicate operating key labels.
Windows
Unless otherwise specied
,
“Windows” represents Windows Vista, Windows 7,
Windows 8 or Windows 10.
Dialogue Dialogue box represents a Windows dialog box.
Mouse Operation
Click: Press and quickly release the left button of the mouse. Right-click: Press and quickly release the right button of the mouse. Double click: Quickly click the left button of the mouse twice.
Drag:
While holding down the left button of the mouse, move the mouse and then release the left button to deposit the chosen item in the desired position.
10
9
8
7
6
5
4
3
2
1
付録索引
2
Safety Information
3
1
Specications
1.1 RS-232C Specications
Transmission Method Communication method: Full duplex
Synchronous method: Start-stop synchronization
Transmission Speed 9600 bps, 19200 bps, 38400 bps, 57600 bps Data Bits 8 bits Parity None Stop bit 1 bits Message terminator (delimiter) CR+LF, CR Flow control Software (XON/XOFF control)
“Handshake (About Buffer Flow Control)” (p. 3)
Electrical Specications
Input voltage level
5 to 15 V ON
-15 to -5 V OFF
Output voltage level
5 to 9 V ON
-9 to -5 V OFF
Handshake (About Buffer Flow Control)
Control during Receiving
Input Buffer Usage Amount
85%
75%
25%
Buffer Space
Send XON
Send XOFF
XON/XOFF control:
• When the data in the receive buffer exceeds 75% of the buffer, XOFF(13H) is sent and the controller is notied that there is not much space remaining in the buffer.
• Processing of the data in the buffer continues, and then XON(11H) is sent and the controller is notied that there
is sufcient remaining space in the buffer when the
amount of data becomes less than 25%.
Control during Sending
XON/XOFF control:
• When XOFF is received, the sending of data is halted. When XON is received, the sending of data is resumed.
1
4
GP-IB Specications
1.2 GP-IB Specications
SH1 Supports all source handshake functions.
AH1 Supports all acceptor handshake functions.
T6 Supports standard talker functions.
Supports serial poll functions. Talk only mode is not supported. Supports the talker cancel function by MLA (My Listen Address).
L4 Supports standard listener functions.
Listener only mode is not supported. Supports the listener cancel function by MTA (My Talk Address).
SR1 Supports all service request functions. RL1 Supports all remote/local functions. PP0 Parallel poll functions are not supported. DC1 Supports all device clear functions. DT1 Supports all device trigger functions. C0 Controller functions are not supported.
Code used: ASCII code
1.3 USB Specications
Connector Series B receptacle Compliance tandard USB2.0 (Full Speed/High Speed) No. of ports 1 Class Communication class Supported OS Windows Vista, Windows 7, Windows 8, Windows 10
1.4 LAN Specications
Connector RJ-45 connector × 1
Compliance standard
IEEE 802.3-compliant Ethernet
Transfer system 10BASE-T/ 100BASE-TX/ 1000BASE-T Auto detected Protocol TCP/IP Function Command control