HIOKI HIOKI Z3210 User guide

Page 1
How to check whether the HID function is
enabled or not
CM4001
1. Turn on the instrument while pressing
off.
1. Turn on the instrument while pressing
*1. To check the firmware version number of the CM4001
3) Press the power key to turn off the instrument.
CM4002
1. Turn on the instrument while pressing
off.
1. Turn on the instrument while pressing
HIOKI Z3210A962-03
Z3210 Wireless Adapter
Instruction Manual for Excel

Introduction

The Z3210ʼs Excel® Direct Input function allows you to input measured values directly into Excel in the same way as a wireless keyboard. By connecting the Z3210 with the firmware version number V2.10 or higher installed to Z3210-compatible devices and enabling the Excel easily input data to existing Excel spreadsheets. Please read this instruction manual to check whether data can be input to your device (computer or tablet) in this way before use.
Supported operating systems: Windows 10
iOS 14, iPadOS 14 Android™ 9, 10, 11 (Operation on ALL terminals is not assured.)

Preparation

Before using this function, you need to enable the HID function of the Z3210 and configure the Bluetooth® connection settings. Depending on your operating environment, the keyboard layout and Excel settings may also be required. See Table 1 about how to enable/disable the HID function of the Z3210.
No keyboard layout settings are required to change in countries using a US101-equivalent keyboard, such
as China, Korea, Taiwan, and the Middle East. However, the keyboard layout setting is required for countries that use a different keyboard from US101, such as France and Germany. Depending on is displayed as a period (.), not a comma (,).
the country, it may be necessary to set Excel options because the decimal point of Z3210
®
Direct Input (HID function)
Direct Input (HID) function, you can
Table 1. How to enable/disable the HID function
Model How to enable/disable the HID function
(V1.03 or
higher) *1
1) Turn on the instrument while pressing the MAX/MIN and RANGE keys.
2) Check that the characters representing the model number “4001” and the firmware version number vEr.andv1.0x” are displayed in turn, and all symbols are displayed.
CM4003
the backlight key and the RANGE key.
2. Press the MAX/MIN k e y. The HID
function can be enabled/disabled every time the key is pressed.
3. Press the HOLD
The instrument is automatically turned
the HOLD and COMP keys to enable/disable the HID function. The instrument is automatically turned
key to confirm.
the backlight and RANGE keys.
2. Press the power key to turn off the instrument.
the HOLD and MAX/MIN keys.
2. Press the power key to turn off the instrument.
1
Page 2
How to check whether the HID function is
enabled or not
FT6031-50
1. Turn on the instrument while pressing
off.
1. Turn on the instrument while pressing
*2. To confirm the firmware version number of the FT6031-50
4) Press the power key to turn off the instrument.
FT6380-50
1. Turn on the instrument while pressing
off.
1. Turn on the instrument while pressing
PD3259-50
1. Turn on the instrument while pressing
off.
1. Turn on the instrument while pressing
IR4052-50
1. Turn on the instrument while holding
off.
1. Turn on the instrument while holding
BT3554-50
1. Turn on the instrument while pressing
instrument.
1. Turn on the instrument while pressing
HIOKI Z3210A962-03
Model How to enable/disable the HID function
(V1.02 or
higher) *2
the COMP and ADJ keys to enable/disable the HID function. The instrument is automatically turned
the 3P/2P k ey.
2. Press the power key to turn off the instrument.
1) Turn on the instrument while pressing the Fn and COMP keys.
2) When the character “vEr” appears on the display, press the ADJ k ey.
3) Check that the characters representing the firmware version number “v1.0x.” and model number “6031” are displayed in turn.
the A/Ω and Fn keys to enable/disable the HID function. The instrument is automatically turned
the HOLD and Fn keys.
2. Press the Fn key.
3. Press and hold the HOLD and Fn keys
for at least 1 s.
4. Press the HOLD k e y. The HID function
can be enabled/disabled every time the
the A/Ω k ey.
2. Press the power key to turn off the instrument.
the HOLD and Fn keys.
2. Press the Fn key.
3. Press and hold the HOLD and Fn keys for at least 1 s.
4. Press the power key to turn off the instrument.
key is pressed.
5. Press the Fn key to confirm.
The instrument is automatically turned
IR4057-50
down the RELEASE ke y.
2. Press and hold the RELEASE key for at least 3 s.
3. Press the COMP key. The HID function
can be enabled/disabled every time the key is pressed.
4. Press the RELEASE key to confirm. The instrument is automatically turned
the comparator buzzer key.
2. Press the arrow key. The HID function can be enabled/disabled every time the key is pressed.
3. Press the ENTER key to confirm.
4. Press the power key to turn off the
down the RELEASE ke y.
2. Press and hold the RELEASE key for at
least 3 s.
3. Turn the rotary switch to the OFF
position to turn off the instrument.
the comparator buzzer key.
2. Press the power key to turn off the instrument.
2
Page 3
How to check whether the HID function is
enabled or not
DT4261
1. Turn on the instrument while holding
1. Set the rotary switch to the Ω position (at
measurement display.
CM4371-50
1. Turn on the instrument while holding
1. Set the rotary switch to the NCV position
measurement display.
CM4141-50
1. Turn on the instrument while holding
1. Set the rotary switch to the TEMP
measurement display.
CM3286-50
1. Turn on the instrument while holding
1. Set the rotary switch to the Phase
measurement display.
HIOKI Z3210A962-03
Model How to enable/disable the HID function
CM4373-50 CM4375-50
down the backlight key and the RANGE key to enable/disable the HID function. The instrument is automatically turned
off.
down the backlight key and the Fn key
to enable/disable the HID function. The instrument is automatically turned
off.
down the backlight key and the Fn key
to enable/disable the HID function. The instrument is automatically turned off.
the 5th position from the OFF position) while holding down the
RANGE key to
turn on the instrument.
2. Release the key.
The display automatically switches to the
(the A+V position for the CM4375-50, at the 5th position from the OFF position) while holding down the
RANGE key to
turn on the instrument.
2. Release the key. The display automatically switches to the
position (at the 5th position from the
OFF position) while holding down the RANGE key to turn on the instrument.
2. Release the key. The display automatically switches to the
down the backlight key and the Fn key to enable/disable the HID function. The instrument is automatically turned off.
Detect position (at the 5th position from
the OFF position) while holding down the
Fn key to turn on the instrument.
2. Release the key.
The display automatically switches to the
3
Page 4
HIOKI Z3210A962-03

How to Check the Firmware Version Number of the Z3210

The HID switching function requires the Z3210 with the firmware version number V2.10 or higher installed. You can find the firmware version number by following the steps below. If you have the Z3210 with the firmware version number V2.10 or lower installed and want to use the HID function, please contact your
authorized Hioki distributor or reseller.
1. Turn on the measuring instrument with the Z3210 connected, and then enable the wireless
communication function. The symbol will be displayed.
2. Open your device’s Bluetooth setting.
Windows 10: Press [Windows] + [I], and then go to [Settings] - [Devices] - [Bluetooth]. iOS, iPadOS: Go to [Settings] - [Bluetooth] Android™: Go to [Settings] - [Wireless & Network] - [Bluetooth] (depends on models)
3. Turn on the deviceʼs Bluetooth.
4. Pair the Z3210 with the device.
Windows 10: Go to [Add Bluetooth or another device] - [Bluetooth] - [Z3210.] iOS, iPadOS: Tap [Z3210.] or [Accessories]
if th
(Visible as [Accessories]
Android™: Tap [Z3210.]
5. The character string [Z3210Vx.xx:model#serial number] is displayed. Check that the characters
representing the version number “Vx.xx” are “V2.10” or higher.
e Z3210 is paired with the device for the first time.)

Pairing the Z3210 with Your Device

Follow the steps below to pair the Z3210 of which the HID function enabled with your device:
1. Turn on the measuring instrument with the Z3210 connected, and turn on the wireless communication function. (e.g., press and hold the HOLD and MAX/MIN keys for at least 1 s to enable the CM4001 wireless
communication function.) The symbol will be displayed.
2. Open the devices Bluetooth setting.
Windows 10: Press [Windows] + [I], and then go to [Settings] - [Devices] - [Bluetooth]. iOS, iPadOS: Go to [Settings] - [Bluetooth] Android™: Go to [Settings] - [Wireless & Network] - [Bluetooth] (depends on models)
3. Turn on the deviceʼs Bluetooth.
4. Pair the Z3210 with the device.
Bluetooth] - [Z3210.]
Windows 10: Go to [Add Bluetooth or another device] iOS, iPadOS: Tap [Z3210.] or [Accessories]
(Visible as [Accessories] if the Z3210 is connected to the device for the first time.)
Android™: Tap [Z3210.]
The symbol will be flashed on and off when the instrument is connected.
- [
4
Page 5
HIOKI Z3210A962-03

Setting the Keyboard Layout for Windows 10

If you do not use a keyboard equivalent to the US101 keyboard or the Japanese 109 keyboard, follow the steps below:
1. Press [Windows] + [I] to open [Windows Settings].
2. Click [Time and Language] - [Region & language].
3. Under [Languages], select the currently set default language (such as “Japanese”) and click
[Options].
4. Click [Keyboard] - [Add a Keyboard]. (Otherwise, click [Hardware Keyboard Layout] - [Change Layout].)
5. Select a keyboard layout you want to use. (US QWERTY)
The new layout is installed on Windows 10.
After the installation has been completed, you can switch the keyboard layout by pressing [Windows] +
[Space].
5
Page 6
HIOKI Z3210A962-03

Setting the Keyboard for iOS and iPadOS

Follow the steps below to set the keyboard:
1. Select [Settings] - [General] - [Keyboard] on the device.
2. Turn off [Enable Caps Lock].
6
Page 7
HIOKI Z3210A962-03
3. In [Settings] - [General] - [Keyboard] - [Hardware Keyboard], turn off [Auto-Capitalization].
If the Z3210 is not paired with your device, [Hardware Keyboard] will not appear. Pair it, and then go
to step 1.

How to Switch the Decimal Point to a Comma (,)

The Z3210 outputs values with the decimal point represented by a period (.). Thus, you do not need to change the decimal point setting in the US, Japan, or other countries where an operating system with the decimal point represented by a period (.) is used. If you are using an operating system with the decimal point represented by a comma (,), follow either one of the two methods below:

Method 1 (Changing the Excel decimal point setting to a comma)

In [Files] - [Options] - [Advanced], click to clear the [Use system digit separators] checkbox, and then enter the period (.) and comma (,) in [Decimal separator] and [Thousands separator], respectively.

Method 2 (Changing decimal points of data from periods into commas without changing the Excel decimal point setting from a comma)

1. Copy and paste all data in a text editor, such as Notepad (for Windows 10).
2. R
eplace all periods with commas, and then copy and paste the replaced data into Excel.

How to Use the HID Function

1. Switch the keyboard input mode to lowercase and half-width characters and numbers.
2. Tap or click the selected cell where you want to enter data on an Excel spreadsheet.
3. Press the instrumentʼs HOLD key (or perform the function to freeze the reading on the screen
temporarily). Numeric values and units are transferred to the selected cell. Do not select another cell during data
transfe
If data cannot be input, check the Excel settings (e.g., sign in to your Microsoft Office account).
r.
7
Page 8
Problem
Instruction
The Z3210 cannot be paired with an Android device
To pair the Z3210 with an Android device through
[Use location].
The Z3210 cannot be found on the device when
The devices that have not been connected may be
completed.
GENNECT Cross is not available.
The Z3210 cannot be connected to GENNECT
the connection setting of GENNECT Cross.
The Excel Direct Input function of the Z3210 is not
Check the following items.
click to clear the [Read-only] checkbox.
GENNECT Cross and the Excel Direct Input
Concurrent use of them is not available. After
enabling/disabling the HID function.
HIOKI Z3210A962-03

Troubleshooting

Identify the problem in the following table and follow the instructions to solve it.
through Bluetooth.
you attempt to pair the Z3210 with iOS for the first
time.
available.
Bluetooth, enable the device’s GPS function (location information). Use OS settings to turn on
displayed as [Accessories] on iOS or iPad OS. It will be correctly displayed after the pairing is
Cross when the HID function is enabled. Please follow the steps below to reconnect the measuring instrument to GENNECT Cross.
1. Delete the measuring instrument on the list of the Bluetooth setting of your device.
2. Disable the HID function of the Z3210. (For details, see the “Preparation” section of this manual.)
3. Reconnect the measuring instrument through
The HID function is disabled.
Enable it. See the “Preparationsection of
this manual for details.
The instrument is not paired with the device.
Unpair the instrument once and try to
register it again.
Excel has not been initialized.
→ Configure the Excel settings so that data
can be input.
The file is read-onl y.
Open the file’s property window, and then
function of Z3210 cannot be used simultaneously.
unpairing the instrument on the Bluetooth setting of your device, turn the HID function on or off,
depending on the function you want to use. See this manual’s “
Preparationsection for details about
8
Page 9
Problem
Instruction
GENNECT Cross displays a PIN on its connection
GENNECT Cross doesn’t start working correctly
manual.
The software keyboard of the connected device
When the device is HID-connected to the
instrument.
The device that has been paired with an instrument displays the PIN after the instrument is turned on.
Restart the instrument.
Windows 10ʼs Bluetooth setting window continues
to display the messageConnected.
Remove the Bluetooth device on Windows 10 and try pairing again.
Windows 10ʼs Bluetooth list repeatedly displays the messages “Paired” and “Connected.”
Remove the Bluetooth device on Windows 10 and try pairing again.
When I try to pair multiple measuring instruments
If you want to register multiple measuring
instrument and register them.
Uppercase and lowercase letters in units are reversed.
Turn off Caps Lock mode.
Excel is not fast enough to accept input data in
In Excel, calculations are performed when cells are
data into an Excel spreadsheet.
Using a comma (,) as the decimal separator in
It is recommended to enter all data into a tab-
spreadsheet.
Measured values cannot be entered when using an
Excel spreadsheet that has been already saved.
Select a cell to enter measured values.
Using applications other than Excel is preferable.
Applications with no particular tasks assigned to its
assigned beforehand.
HIOKI Z3210A962-03
screen (Instrument Settings screen) and attempts to be paired with the Z3210 to use the HID function.
cannot be used for typing.
when the HID function is enabled. Follow the steps below:
1. Close GENNECT Cross.
2. Remove the measuring instrument on the
Bluetooth settings of your device.
3. Disable the HID function of the Z3210. For
details, see the “Preparation
section of this
measuring instrument, the software keyboard may be disabled depending on the device settings. If necessary, turn off the connected measuring
with an iOS device, the second and subsequent instruments disappear from the list.
time, missing some characters.
Excel without changing the language setting is preferable.
instruments subsequently, turn off and on the iOS deviceʼs Bluetooth connectivity for every measuring
active, slowing down the process on some computers. If this happens, the following methods are recommended: (1) configure the Excel setting such that it performs follow-up calculations, or (2) enter all data into a tab-capable text editor, such as Notepad (Windows 10), and copy and paste the
capable text editor, including Notepad (Windows
10), and copy and paste the data into an Excel
[Tab] may be available. Check if no task is
9
Page 10
HIOKI Z3210A962-03
EN
Mar. 2022 Revised edition 3 Z3210A962-03 22-03H
10
Loading...