*1. To check the firmware version number of the CM4001
3) Press the power key to turn off the instrument.
CM4002
1. Turn on the instrument while pressing
off.
1. Turn on the instrument while pressing
HIOKI Z3210A962-03
Z3210 Wireless Adapter
Instruction Manual for Excel
Introduction
The Z3210ʼs Excel® Direct Input function allows you to input measured values directly into Excel in the
same way as a wireless keyboard. Byconnecting the Z3210 with the firmware version number V2.10 or
higher installed to Z3210-compatible devices and enabling the Excel
easily input data to existing Excel spreadsheets. Please read this instruction manual to check whether
data can be input to your device (computer or tablet) in this way before use.
Supported operating systems: Windows 10
iOS 14, iPadOS 14
Android™ 9, 10, 11
(Operation on ALL terminals is not assured.)
Preparation
Before usingthis function, you need to enable the HID function of the Z3210 and configure the Bluetooth®
connection settings.Depending on your operating environment, the keyboard layout and Excel settings may also be required.
See Table 1 about how to enable/disable the HID function of the Z3210.
No keyboard layout settings are required to change in countriesusing a US101-equivalent keyboard, such
as China, Korea, Taiwan, and the Middle East. However, the keyboard layout setting is required for
countries that use a different keyboard from US101, such as France and Germany.
Depending on
is displayed as a period (.), not a comma (,).
the country, it may be necessary to set Excel options because the decimal point of Z3210
®
Direct Input (HID function)
®
Direct Input (HID) function, you can
Table 1. How to enable/disable the HID function
Model How to enable/disable the HID function
(V1.03 or
higher) *1
1) Turn on the instrument while pressing the MAX/MINandRANGEkeys.
2) Check that the charactersrepresenting the model number “4001” and the firmware version number
“vEr.” and “v1.0x” are displayed in turn, and all symbols are displayed.
CM4003
the backlight key and the RANGE key.
2.Press the MAX/MINk e y. The HID
function can be enabled/disabled every
time the key ispressed.
3.Press the HOLD
The instrumentis automatically turned
the HOLDandCOMPkeys to
enable/disable the HID function.
The instrumentis automatically turned
key to confirm.
the backlight andRANGE keys.
2. Press the power key to turn off the
instrument.
the HOLD and MAX/MIN keys.
2. Press the power key to turn off the
instrument.
1
Page 2
How to check whether the HID function is
enabled or not
FT6031-50
1. Turn on the instrument while pressing
off.
1. Turn on the instrument while pressing
*2. To confirm the firmware version number of the FT6031-50
4) Press the power key to turn off the instrument.
FT6380-50
1. Turn on the instrument while pressing
off.
1. Turn on the instrument while pressing
PD3259-50
1. Turn on the instrument while pressing
off.
1. Turn on the instrument while pressing
IR4052-50
1. Turn on the instrument while holding
off.
1. Turn on the instrument while holding
BT3554-50
1. Turn on the instrument while pressing
instrument.
1. Turn on the instrument while pressing
HIOKI Z3210A962-03
Model How to enable/disable the HID function
(V1.02 or
higher) *2
the COMPand0Ω ADJkeys to
enable/disable the HID function.
The instrumentis automatically turned
the 3P/2Pk ey.
2. Press the power key to turn off the
instrument.
1) Turn on the instrument while pressing the FnandCOMPkeys.
2) When the character “vEr” appears on the display,press the 0Ω ADJk ey.
3) Check that the charactersrepresenting the firmware version number “v1.0x.” and model number
“6031” are displayed in turn.
the A/ΩandFnkeys to enable/disable
the HID function.
The instrumentis automatically turned
the HOLDandFnkeys.
2. Press the Fn key.
3. Press and hold the HOLD and Fn keys
for at least 1 s.
4. Press the HOLD k e y. The HID function
can be enabled/disabled every time the
the A/Ωk ey.
2. Press the power key to turn off the
instrument.
the HOLD and Fn keys.
2. Press the Fn key.
3. Press and hold the HOLD and Fn keys
for at least 1 s.
4. Press the power key to turn off the
instrument.
key is pressed.
5. Press the Fn key to confirm.
The instrumentis automatically turned
IR4057-50
down the RELEASE ke y.
2. Press and hold the RELEASE key for at
least 3 s.
3. Press the COMP key. The HID function
can be enabled/disabled every time the
key ispressed.
4. Press the RELEASE key to confirm.
The instrument is automatically turned
the comparator buzzer key.
2.Press the arrow key. The HID function
can be enabled/disabled every time the
key ispressed.
3. Press the ENTER key to confirm.
4. Press the power key to turn off the
down the RELEASE ke y.
2. Press and hold the RELEASE key for at
least 3 s.
3. Turn the rotary switch to the OFF
position to turn off the instrument.
the comparator buzzer key.
2. Press the power key to turn off the
instrument.
2
Page 3
How to check whether the HID function is
enabled or not
DT4261
1. Turn on the instrument while holding
1. Set the rotary switch to the Ωposition (at
measurement display.
CM4371-50
1. Turn on the instrument while holding
1. Set the rotary switch to the NCV position
measurement display.
CM4141-50
1. Turn on the instrument while holding
1. Set the rotary switch to the TEMP
measurement display.
CM3286-50
1. Turn on the instrument while holding
1. Set the rotary switch to the Phase
measurement display.
HIOKI Z3210A962-03
ModelHow to enable/disable the HID function
CM4373-50
CM4375-50
down the backlight key and the RANGE
key to enable/disable the HID function.
The instrumentis automatically turned
off.
down the backlight key and the Fnkey
to enable/disable the HID function.
The instrumentis automatically turned
off.
down the backlight key and the Fnkey
to enable/disable the HID function.
The instrumentis automatically turnedoff.
the 5th position from the OFFposition)
while holdingdown the
RANGE key to
turn on the instrument.
2. Release the key.
The display automatically switches to the
(the A+Vposition for the CM4375-50, at
the 5th position from the OFFposition)
while holdingdown the
RANGE key to
turn on the instrument.
2. Release the key.
The display automatically switches to the
position (at the 5th position from the
OFF position) while holdingdown the
RANGE key to turn on the instrument.
2.Release the key.
The display automatically switches to the
down the backlight key and the Fn key
to enable/disable the HID function.
The instrument is automatically turned
off.
Detectposition (at the 5th position from
the OFFposition) while holdingdown the
Fn key to turn on the instrument.
2. Release the key.
The display automatically switches to the
3
Page 4
HIOKI Z3210A962-03
How to Check the Firmware Version Number of the Z3210
The HID switching function requires the Z3210 with the firmware version number V2.10 or higher installed.
You can find the firmware version number by following the stepsbelow. If you have the Z3210 with the
firmware version number V2.10 or lower installedand want to use the HID function, please contact your
authorized Hioki distributor or reseller.
1. Turn on the measuring instrument with the Z3210 connected, and then enable the wireless
communication function.
The symbolwill be displayed.
2. Open your device’s Bluetooth setting.
Windows 10: Press[Windows] + [I], and then go to [Settings] - [Devices] - [Bluetooth].
iOS, iPadOS: Go to [Settings] - [Bluetooth]
Android™: Go to [Settings] - [Wireless & Network] - [Bluetooth](depends on models)
3. Turn on the deviceʼs Bluetooth.
4. Pair the Z3210 with the device.
Windows 10: Go to [Add Bluetooth or another device] - [Bluetooth] - [Z3210.]
iOS, iPadOS: Tap [Z3210.] or [Accessories]
if th
(Visibleas[Accessories]
Android™: Tap [Z3210.]
5. The character string [Z3210Vx.xx:model#serial number] is displayed. Check that the characters
representing the version number “Vx.xx” are “V2.10” or higher.
e Z3210 ispaired with the device for the firsttime.)
Pairing the Z3210 with Your Device
Follow the steps below to pair the Z3210 of which the HID function enabled with your device:
1. Turn on the measuring instrument with the Z3210 connected, and turn on the wireless
communication function.
(e.g., press and hold the HOLD and MAX/MIN keys for at least 1 s to enable the CM4001 wireless
communication function.)
The symbolwill be displayed.
2. Open the device’s Bluetooth setting.
Windows 10: Press[Windows] + [I], and then go to [Settings] - [Devices] - [Bluetooth].
iOS, iPadOS: Go to [Settings] - [Bluetooth]
Android™: Go to [Settings] - [Wireless & Network] -[Bluetooth](depends on models)
3. Turn on the deviceʼs Bluetooth.
4. Pair the Z3210 with the device.
Bluetooth] - [Z3210.]
Windows 10: Go to [Add Bluetooth or another device]
iOS, iPadOS: Tap [Z3210.] or [Accessories]
(Visibleas [Accessories] if the Z3210 isconnected to the device for the firsttime.)
Android™: Tap [Z3210.]
The symbolwill be flashed on and off when the instrumentis connected.
- [
4
Page 5
HIOKI Z3210A962-03
Setting the Keyboard Layout for Windows 10
If you do not use a keyboard equivalent to the US101 keyboard or the Japanese 109 keyboard, follow the
steps below:
1. Press [Windows] + [I] to open [Windows Settings].
2. Click [Time and Language] - [Region & language].
3. Under [Languages], select the currently set default language (such as “Japanese”) and click
5. Select a keyboard layout you want to use. (US QWERTY)
The new layout isinstalled on Windows10.
After the installationhas been completed, you can switch the keyboard layout by pressing[Windows] +
[Space].
5
Page 6
HIOKI Z3210A962-03
Setting the Keyboard for iOS and iPadOS
Follow the steps below to set the keyboard:
1. Select [Settings] - [General] - [Keyboard] on the device.
2. Turn off [Enable Caps Lock].
6
Page 7
HIOKI Z3210A962-03
3. In [Settings] - [General] - [Keyboard] - [Hardware Keyboard], turn off [Auto-Capitalization].
If the Z3210 is not paired with your device,[Hardware Keyboard]will not appear. Pair it, and then go
to step1.
How to Switch the Decimal Point to a Comma (,)
The Z3210 outputs values with the decimal point represented by a period (.). Thus, you do not need to
change the decimal point setting in the US, Japan, or other countries where an operating system with the
decimal point represented by a period (.) is used. If you are using an operating system with the decimal
point represented by a comma (,), follow either one of the two methods below:
Method 1 (Changing the Excel decimal point setting to a comma)
In [Files] - [Options] - [Advanced], click to clear the [Use system digit separators] checkbox, and then
enter the period (.) and comma (,) in [Decimal separator] and [Thousands separator], respectively.
Method 2 (Changing decimal points of data from periods into commas without changing the Excel
decimal point setting from a comma)
1. Copy and paste all data in a text editor, such as Notepad (for Windows 10).
2. R
eplace all periods with commas, and then copy and paste the replaced data into Excel.
How to Use the HID Function
1. Switch the keyboard input mode to lowercase and half-width characters and numbers.
2. Tap or click the selected cell where you want to enter data on an Excel spreadsheet.
3. Press the instrumentʼs HOLD key (or perform the function to freeze the reading on the screen
temporarily).
Numeric values and units are transferred to the selected cell. Do not select another cell during data
transfe
If data cannot be input, check the Excel settings(e.g.,sign in to your Microsoft Office account).
r.
7
Page 8
Problem
Instruction
The Z3210 cannot be paired with an Android device
To pair the Z3210 with an Androiddevice through
[Use location].
The Z3210 cannot be found on the device when
The devices that have not been connected may be
completed.
GENNECT Crossis not available.
The Z3210 cannot be connected to GENNECT
the connection setting of GENNECT Cross.
The Excel Direct Input function of the Z3210 is not
Check the following items.
click to clear the [Read-only]checkbox.
GENNECT Crossand the Excel Direct Input
Concurrent use of them is not available. After
enabling/disabling the HID function.
HIOKI Z3210A962-03
Troubleshooting
Identify the problem in the following table and follow the instructions to solve it.
through Bluetooth.
you attempt to pair the Z3210 with iOS for the first
time.
available.
Bluetooth, enable the device’s GPS function
(location information). Use OS settings to turn on
displayedas[Accessories] on iOS or iPadOS. It
will be correctly displayed after the pairing is
Cross when the HID function is enabled.
Please follow the steps below to reconnect the
measuring instrument to GENNECT Cross.
1. Delete the measuring instrument on the list of
the Bluetooth setting of your device.
2. Disable the HID function of the Z3210. (For
details, see the “Preparation” section of this
manual.)
3. Reconnect the measuring instrument through
・ The HID function is disabled.
→ Enable it. See the “Preparation” section of
this manual for details.
・ The instrument is not paired with the device.
→ Unpair the instrument once and try to
register it again.
・Excel has not been initialized.
→ Configure the Excel settings so that data
can be input.
・ The file is read-onl y.
→ Open the file’s property window, and then
function of Z3210 cannot be usedsimultaneously.
unpairing the instrument on the Bluetooth setting of
your device, turn the HID function on or off,
depending on the function you want to use. See
this manual’s “
Preparation” section for details about
8
Page 9
Problem
Instruction
GENNECT Crossdisplays a PIN on its connection
GENNECT Crossdoesn’t start working correctly
manual.
The softwarekeyboard of the connecteddevice
When the deviceis HID-connected to the
instrument.
The device that has been paired with an instrument
displays the PIN after the instrument is turned on.
Restart the instrument.
Windows 10ʼs Bluetooth setting window continues
to display the message “Connected.”
Remove the Bluetooth device on Windows 10 and
try pairing again.
Windows 10ʼs Bluetooth list repeatedly displays the
messages “Paired” and “Connected.”
Remove the Bluetooth device on Windows 10 and
try pairing again.
When I try to pair multiple measuring instruments
If you want to register multiple measuring
instrument and register them.
Uppercase and lowercase letters in units are
reversed.
Turn off Caps Lock mode.
Excel is not fast enough to accept input data in
In Excel, calculations are performed when cells are
data into an Excel spreadsheet.
Using a comma (,) as the decimalseparator in
It isrecommended to enter all data into a tab-
spreadsheet.
Measured values cannot be entered when using an
Excel spreadsheet that has been already saved.
Select a cell to enter measuredvalues.
Using applications other than Excel is preferable.
Applications with no particular tasks assigned to its
assigned beforehand.
HIOKI Z3210A962-03
screen(InstrumentSettingsscreen)andattempts
to be paired with the Z3210 to use the HID function.
cannot be used for typing.
when the HID function isenabled.
Follow the stepsbelow:
1. Close GENNECT Cross.
2. Remove the measuring instrument on the
Bluetooth settings of your device.
3. Disable the HID function of the Z3210. For
details, see the “Preparation
” section of this
measuring instrument, the software keyboard may
be disabled depending on the device settings. If
necessary, turn off the connected measuring
with an iOS device, the second and subsequent
instruments disappear from the list.
time, missing somecharacters.
Excel without changing the language setting is
preferable.
instruments subsequently, turn off and on the iOS
deviceʼs Bluetooth connectivity for every measuring
active, slowing down the process on some
computers. If this happens, the following methods
are recommended: (1) configure the Excel setting
such that it performs follow-up calculations, or (2)
enter all data into a tab-capable text editor, such as
Notepad (Windows 10), and copy and paste the
capable text editor, including Notepad (Windows
10), and copy andpaste the data into an Excel
[Tab] may be available. Check if no taskis
9
Page 10
HIOKI Z3210A962-03
EN
Mar. 2022 Revisededition 3
Z3210A962-03 22-03H
10
Loading...