Hioki CM4375, CM4376 Instruction Manual

CM4375 CM4376
AC/DC CLAMP METER
Sept. 2018 Edition 1 CM4375A961-00 18-09H
Instruction Manual
EN

Contents

Introduction ..................................................................................................... 1
Notation .......................................................................................................... 2
Verifying Package Contents ...........................................................................4
Options (sold separately)................................................................................5
Usage Notes ................................................................................................... 6
1 Overview 11
1.1 Product Overview and Features ......................................................... 11
1.2 Part Names ........................................................................................12
2 Making Measurements 13
2.1 Inspection Before Measurement ........................................................13
2.2 Current Measurement ........................................................................14
Manual Hold / Auto Hold ......................................................................15
Filter Function.....................................................................................18
MAX value/MIN value/AVG value/PEAK value ...................................19
Rush current (INRUSH)......................................................................20
2.3 Other Measurement Functions ........................................................... 21
2.4 Bluetooth® Communications (only for CM4376) ................................. 25
CM4375A961-00
Index
i
Contents
2.5 Backlight / Auto Power Save (APS) .....................................................30
2.6 Power-on Option Table ....................................................................... 31
3 Specications 33
3.1 GeneralSpecications .......................................................................33
3.2 Inputspecications/Measurementspecications ............................... 35
3.3 Accuracy Table ................................................................................... 42
4 Repairs, Inspections, and Cleaning 57
4.1 Troubleshooting .................................................................................. 57
4.2 Error display ....................................................................................... 59
4.3 Insert/Replace Batteries ..................................................................... 60
4.4 Cleaning ............................................................................................. 61
Index 63
WarrantyCerticate
ii

Introduction

Thank you for purchasing the Hioki CM4375, CM4376 AC/DC Clamp Meter. To obtain maximum performance from the instrument over the long term, be sure to read this manual carefully and keep it handy for future reference. Read the separate document “Operating Precautions” carefully before using the instrument.
Target audience
This manual has been written for use by individuals who use the product in question or who teach others to do so. It is assumed that the reader possesses basic electrical knowledge (equivalent to that of someone who graduated from the electrical program at a technical high school).
Trademark
• Bluetooth® is a registered trademark of Bluetooth SIG, Inc.(USA). The trademark is used by HIOKI E.E. CORPORATION under license.
• Android, Google Play, and Google Chrome are trademarks of Google, Inc.
• IOS is a registered trademark of Cisco Systems, Inc. and/or its afliates in the United States and certain other countries.
• iPhone, iPad, iPad miniTM, iPad Pro, and iPod touch are trademarks of Apple Inc.
• The App Store is a service mark of Apple Inc.
• Any other products and company names are generally either trade names, registered trademarks or trademarks of respective companies.
1
索 引

Notation

Notation
Symbols afxed to the instrument
Indicates cautions and hazards. Refer to the "Usage Notes" (p. 6) section of the instruction manual and the included “Operating Precautions” for more information.
Indicates that the instrument may be connected to or disconnected from a live conductor.
Screen display
The instrument screen displays the alphanumeric characters as follows.
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
1 2 3 4 5 6 7 8 9 0
A different display is used in the case below.
: Wiring break detected
2
Notation
Accuracy
We dene measurement tolerances in terms of f.s. (full scale), rdg. (reading) and dgt. (digit) values with the
following meanings:
f.s. (maximum display value/range)
The maximum displayable value. This is usually the name of the currently selected range.
rdg. (displayed value)
The value currently being measured and displayed on the measuring instrument.
dgt. (resolution)
The smallest displayable unit on a digital measuring instrument, i.e., the input value that causes
the digital display to show a “1” as the least-signicant digit.
索 引
3

Verifying Package Contents

L4937 マグネットアダプ
L4934 小ワニグチ
マグネ付ストラップ
Verifying Package Contents
Model CM4375 or CM4376
AC/DC Clamp Meter
Model L9207-10 Test Lead
Model C0203 Carrying Case
LR03 Alkaline battery ×2
Instruction Manual*
Operating Precautions (0990A907)
Precautions Concerning Use of Equipment that Emits Radio Waves (only for model CM4376)
* Instruction manuals may also be available in other languages.
Please visit our website at http://www.hioki.com
4

Options (sold separately)

9243 graber
L4937 マグネットアダプ
L4934 小ワニグチ
マグネ付ストラップ
DM4910 熱電対
DT4911TestLead
DT4912TestLead
L4930 接続ケーブル
9243 graber
L4937 マグネットアダプ
L4934 小ワニグチ
マグネ付ストラップ
L9207-10
DM4910 熱電対
DT4911TestLead
DT4912TestLead
L4930 接続ケーブル
L4931renketu
9243 graber
L4937 マグネットアダプ
L4934 小ワニグチ
マグネ付ストラップ
L9207-10
DM4910 熱電対
DT4911TestLead
DT4912TestLead
L4930 接続ケーブル
L4931renketu
L4931 延長ケーブル
L4932(+9207-10cap)
L4933 コンタクトピン
L4935 ワニ口
9243 graber
L4937 マグネットアダプ
9243 graber
L4937 マグネットアダプ
L4934 小ワニグチ
マグネ付ストラップ
L9207-10
DM4910 熱電対
DT4911TestLead
DT4912TestLead
L4930 接続ケーブル
L4931renketu
L4931 延長ケーブル
L4932(+9207-10cap)
L4933 コンタクトピン
L4935 ワニ口
L4936 バスバー
L4937 マグネットアダプ
9243 graber
L4937 マグネットアダプ
L4934 小ワニグチ
マグネ付ストラップ
L9207-10
DM4910 熱電対
DT4911TestLead
DT4912TestLead
L4930 接続ケーブル
L4931renketu
L4931 延長ケーブル
L4932(+9207-10cap)
9243 graber
L4937 マグネットアダプ
L4934 小ワニグチ
マグネ付ストラップ
L9207-10
DM4910 熱電対
DT4911TestLead
DT4912TestLead
L4930 接続ケーブル
L4931renketu
L4931 延長ケーブル
L4932(+9207-10cap)
L4933 コンタクトピン
L4937 マグネットアダプ
L4934 小ワニグチ
L4937 マグネットアダプ
L4934 小ワニグチ
マグネ付ストラップ
9243 graber
L4937 マグネットアダプ
DM4910 熱電対
Options (sold separately)
L9207-10 Test Lead
L4930 Connection Cable Set (Length: 1.2 m)
L4931 Extension Cable Set * (Length: 1.5 m, with the coupling connector)
DT4910 Thermocouples (K)
C0203 Carrying Case
*1: CAT IV 600 V/ CAT III 1000 V/ CAT II 1000 V *5: CAT III 300 V/ CAT II 600 V *2: CAT IV 600 V/ CAT III 1000 V *6: 33 V AC/ 70 V DC *3: CAT III 1000 V *7: CAT III 600 V/ CAT II 600 V *4: CAT III 600 V *8: CAT IV 1000 V
1
*
2
*
2
L4933 Contact Pin Set
L4934 Small Alligator Clip Set
L4935 Alligator Clip Set
9243 Grabber Clip
L4936 Bus Bar Clip Set
L4937 Magnetic Adapter Set
9804 Magnetic Adapter *
L4932 Test Pin Set
L4938 Test Pin Set
L4939 Breaker Pin Set
6
*
2
*
3
*
4
*
8
1
*
7
*
5
*
3
*
4
*
索 引
5

Usage Notes

Usage Notes
Follow these precautions to ensure safe operation and to obtain the full benets of the various
functions. Read the separate document “Operating Precautions” carefully before using the
instrument. Ensure that your use of the product falls within the specications not only of the
instrument itself, but also of any accessories, options, batteries, and other equipment being used.
DANGER
To prevent an electric shock, do not touch any areas beyond the barrier
while the instrument is in use.
See: "1.2 Part Names" (p. 12)
The maximum measurement current varies with the frequency, and the
current that can be measured continuously is limited. Operating the instrument at less than this limitation is referred to as derating. Do not measure currents in excess of the derating curve. Doing so may result in instrument damage or malfunction, a re, or burn due to sensor heating.
• To prevent an electric shock, conrm that the white portion (insulation layer)
inside the cable is not exposed. If a color inside the cable is exposed, do not use the cable.
6
Usage Notes
WARNING
Do not allow the instrument to get wet, and do not take measurements with
wet hands. This may cause an electric shock. (This precaution does not
apply to insulated conductors.)
To prevent an electric shock, do not exceed the lower of the ratings shown
on the instrument and test leads.
CAUTION
Do not place any foreign object between the jaws or any insert foreign object into the gap of the sensor head. Doing so may worsen the performance of the sensor or the opening-closing operation of the sensor head.
Avoid dropping or jarring the instrument, which could damage the jaw, adversely affecting measurement.
Attach the clamp around only one conductor. If you clamp single-
phase (2-wire) or three-phase (3-wire) conductors together, the instrument will not be able to make a measurement.
索 引
7
Usage Notes
Test Lead
To prevent an electric shock, when measuring the voltage of a power line use a test lead that satises the following criteria:
The optional test leads provided for the instrument conform to the safety standard EN61010. Use a test lead in accordance with its dened measurement
category and rated voltage.
The cable is hardened in freezing temperatures. Do not bend or pull it to avoid tearing its shield or cutting cable.
8
WARNING
• Conforms to safety standards IEC61010 or EN61010
• Measurement category III or IV
Its rated voltage is higher than the voltage to be measured
To prevent a short-circuit accident, be sure to use the test leads with the
sleeves attached when performing measurements in the CAT III and CAT IV
measurement categories.
If the sleeves are removed during measurement, stop the measurement.
CAUTION
Model L4937, 9804 Magnetic Adapter Set (optional)
Usage Notes
DANGER
P
ersons wearing electronic medical devices such as a pacemaker should not use the Magnetic Adapter Set. Such persons should avoid even proximity to the Magnetic Adapter Set, as it may be dangerous. Medical device operation could be compromised, presenting a hazard to human life.
CAUTION
• Do not subject the Magnetic Adapter Set to mechanical shock, for example, due to dropping it. Shock can cause it to be chipped or cracked.
• Do not use the Magnetic Adapter Set in locations where it may be exposed to rainwater, dust, or condensation. In those conditions, the Magnetic Adapter Set may be decomposed or deteriorated. The magnet adhesion may be diminished. In such case, the instrument may not be hung in place and may fall.
• Do not bring the Magnetic Adapter Set near magnetic storage device such as
oppy disks, magnetic cards, pre-paid cards, or magnetized tickets. Doing so may
corrupt and may render them unusable. Furthermore, if the Magnetic Adapter Set is brought near precision electronic equipment such as PCs, TV screens, or electronic wrist watches, they may fail.
索 引
9
Usage Notes
10
1

Overview

1.1 Product Overview and Features

This instrument is a clamp meter that can perform true RMS measurement of current simply by clamping it around a circuit. In addition to current, it provides voltage measurement, frequency measurement, rush current measurement, resistance measurement, diode measurement, capacitance measurement, temperature measurement, and DC power measurement. Model CM4376 also provide Bluetooth® communications functionality, allowing measurement data to be monitored and logged from a mobile device.
Measurement function list
DC current/DC voltage, DC power
Capacitance, temperature
Continuity check, resistance, diode
AUTO AC/DC, AC voltage, DC voltage, AC+DC voltage, frequency
AUTO AC/DC, AC current, DC current, AC+DC current, frequency
11
索 引
Overview

1.2 Part Names

Front Rear
1
2
3
(CM4376)
12
1 Operation grip
2 Jaw open/closed mark
(The jaws are open if the mark is not
4
5
6
7
8
9
10
11
12
showing.)
3 SHIFT key
(Selects function indicated in blue lettering.)
4 Jaw
5 Barrier
6 Serial number (The serial number consists of
9 digits. The rst two (from the left) indicate
the year of manufacture, and the next two indicate the month of manufacture.)
7 Rotary switch
8 HOLD key
9 LCD
10 Battery cover
11 Operation keys
12 Measurement terminals
2
NO
NONO

Making Measurements

2.1 Inspection Before Measurement

Check if there is any damage to the instrument occurred during storage or shipping and
verify that instrument operates normally before using it. If you nd any damage, contact your
authorized Hioki distributor or reseller.
Check item
The battery cover is closed and its screw has
been securely tightened.
There is no foreign matter on the
measurement terminals. (p. 12)
The test leads are not broken.
1 Ω or less
OK
There is no damage to the test lead
insulation, and neither the white sheathing nor
metal conductor inside the wire are exposed.
The instrument is neither damaged nor cracked.
No indicators are missing.
(All lit up)
13
索 引
Current Measurement

2.2 Current Measurement

1
2
Press for 1 sec.
Zero adjustment
Frequency detection range of AC current
5.0 A or more
DC current polarity detection function (p. 31)
If the measured value is negative, the buzzer will sound, and the display will turn red (threshold: −10 A).
14
3
Clamp the instrument around a conductor.Turn the rotary switch.
4
AUTO
(AUTO AC/DC)
e.g.: 3P4W (3-phase, 4-wire) circuit
breaker (AC current measurement)
Be sure that the currents direction points the arrow.
(AC A)
(AC+DC A)(DC A)
Hz
(Frequency)

Manual Hold / Auto Hold

Current Measurement
Manual hold Auto hold
Press for 1 sec.
Measured value
retains.
Pressing the HOLD key again cancels the measured value hold function.
(Measured value stabilizes.)
Measured value automatically retains.
Pressing the HOLD key for 1 sec. cancels the auto hold function.
blinks.
Clamp the instrument around a conductor.
Disconnect
索 引
15
Current Measurement
Auto hold conditions
Display value updates are stopped when the following two conditions are satised:
• When the measured value exceeds the threshold value described in the table in the next page. (voltage, current). When the measured value is less than the threshold value described in the table in the next page.
(resistance, continuity, diode)
• When the range over which the measured value is uctuating stabilizes within the uctuation range described in the table in the next page.
Held measured value
Measured value
Auto hold e.g.: 100.0 A
Fluctuation range
Fluctuation range
Auto hold e.g.: 99.0 A
Fluctuation range
Threshold e.g.: 12.0 A
Start
End
If the measured value falls below the threshold value (voltage, current) or exceeds the threshold value (resistance, continuity, diode) after display value updates are stopped, the display value update is restarted.
Display value updates will stop if the two conditions are satised once again.
End
Start
Measurement
End
Start
Time
16
Current Measurement
Measurement function Fluctuation range Threshold value
AUTO A AC current DC current AC+DC current
AC voltage DC voltage (excluding the 600.0 mV range) AC+DC voltage
Resistance Continuity
Diode 1.800 V range: within 40 counts 1.800 V range: 1460 counts
The auto hold function only operates for the above measurement functions.
Within 120 counts 120 counts
6.000 V/60.00 V/600.0 V range: within 120 counts 1000 V range: within 20 counts 1500 V range: within 30 counts
/6.000 kΩ/60.00 kΩ/
600.0
Ω
600.0 k
Ω range: within 100 counts
6.000 V/60.00 V/600.0 Vrange: 120 counts 1000 V range: 20 counts 1500 V range: 30 counts
600.0 Ω/6.000 kΩ/60.00 kΩ/
600.0 k
Ω range: 4900 counts
17
索 引
Current Measurement

Filter Function

FILTER OFF FILTER ON
Measured value including noise
Press for 1 sec.
Measured value with reduced noise
Frequency characteristics when using the
lter function (100 A input)
FILTER OFF
FILTER ON Passband 100 [Hz]
Measured value [A]
Frequency [Hz]
18
Turn off the lter function when performing
measurement of power supply frequencies in excess
of 100 Hz, for example on an aircraft or ship.