Thank you for purchasing the HIOKI Model 9455 PIN TYPE LEAD.To obtain maximum per-
formance from the device, please read this manual first, and keep it handy for future reference.
Inspection
When you receive the product, inspect it to ensure that no damage occurred during shipment. If you find any damage or discover that the product does not perform as indicated in
its specification
s, please contact your authorized Hioki distributor or reseller.
Safety Information
Carefully read the following safety notes before using the product.
Mishandling during use could result in injury or death, as well as
damage to the product. Familiarize yourself with the instruction sand
precautions in this manual before use the instrument.
The following symbols in this manual indicate the relative importance of cautions and warnings.
1
Safety Symbols
Indicates that incorrect operation presents an extreme hazard that
could result in serious injury or death to the user.
Indicates that incorrect operation p
could result in serious injury or death to the user.
Indicates that incorrect operation presents a po
user or damage to the device.
Indicates advisory items related to pe
the device.
Indicates the presence of a potential hazard.
For more information about locations where this symbol appears on
produ
ct components, see the “Usage Notes” section (p.2), warning
messages listed at the beginning of operating instructions.
Indicates DC (Direct Current).
resents a significant hazard that
ssibility of injury to the
rformance or correct operation of
Page 18
2
HIOKI 9455A980-04
Usage Notes
Usage Notes
Observe the following precautionary information to ensure that the instrument can be used
safely and in a manner that allows it to perform as described in its specifications.
Use of the instrument should confirm not only to its specifications, but also to the specifications of all accessories, options, and other equipment in use.
Do not use these leads on a circuit with a voltage exceeding the maximum input voltage of the tester to which they are connected. In any
event, do not use on a circuit exceeding 60 V DC. There is a danger of
electric shock.
• The ends of the 9455 Pin Type Lead are sharp. Be careful to avoid injury.
• Before use, verify that the insulation on leads is not-damaged and that
no metal is exposed. If you find any damage or failure, replace the 9455
Pin Type Lead with those specified by Hioki, as the product will not be
able to make accurate measurements or send/ receive data otherwise.
Page 19
OverviewChapter 1
1172-44 4-Terminal Probe (R-Arm) (Option)
Source
Sense
Tip of the probe
26.5
14.2
6.1
0.2
Source electrode
0.2
φ0.1
φ0.3
Sense electrode
End cap
HIOKI 9455A980-04
1.1Product Overview
The ends of the 9455 Pin Type Lead have an extremely fine four-electrode construction,
developed for testing for raised leads on mounted ICs. They can therefore be used for
accurate measurement of resistance on small-dimensioned items.
1.2Names of Parts
Chapter 1 Overview
3
3
Page 20
4
0.2 mm
Source
electrode
Sense
electrode
HIOKI 9455A980-04
Chapter 2 Method of Measurement
Method of
Measurement
Connect the leads correctly to the tester. For details, refer to the instructions supplied with
the tester.
For testers with zero adjustment, carry out the zero adjustment with the standard leads
connected, then remove the standard leads and connect these leads to carry out measurement.
Chapter 2
Hold these leads lightly against the two sides of the item to be tested.
After the sense electrode contacts the item, pushing the probe in by another 0.2 mm brings
the
source electrode into contact, and allows measurement to start.
Page 21
Chapter 2 Method of Measurement
Probe may be
damaged if held at
an angle.
Hold
perpendicularly
against item being
tested.
Do not move probe sideways
while pressed down.
HIOKI 9455A980-04
5
These leads are a precision instrument. Take all reasonable care in handling them.
• Treat the tips of the probes carefully; do not press them too hard against
the item being tested or anything else. Because of the precision construction, this could cause the tips to break or bend.
• Hold the probes perpendicularly against the tested item. If pressed at an
scraped off material may prevent the four-terminal function from
angle,
operating correctly.
• While the probe is pressed against an item being tested, do not move it
sideways, a
using the 9466 Remote control switch.
s this may result in a broken tip. Take particular care when
3
• There are two movable parts on the pin tips. Measurement uses a stroke
mm.
of 0.2
• After use, protect the probe tips with the plastic caps.
Page 22
6
The end cap can be purchased via authorized Hioki distributor or reseller.
Apply the adhesive here.
4-Terminal Probe
Install the end cap to the 4-Terminal Probe.
Pan-head screw
(polycarbonate) (M3×6)
End cap
Probe body
1172-44
HIOKI 9455A980-04
Chapter 3 Maintenance and Repair
Maintenance and
Repair
If you find any damage to the instrument, please contact your authorized Hioki distributor
or reseller for repair.
Although repairs by customers are discouraged, you can replace the 1172-44 4-Terminal
Probe (R-arm) with a new one, which can be purchased separately, by following the procedure below.
Procedure
Fix the part of the spring of the 1172-44 4-Terminal Probe with adhesive (epoxy
1.
resin or other types) and so on.
It is to make it elastic only by 1 step by this lead though 1172-44is elastic by 2 steps.
Install the end cap before the
and the end-cap screw to become unable to tighten up.
adhesive has cured. Failure to do so will cause the Probe
Chapter 3
Remove the pan-head screw (polycarbonate) (M3 × 6) from the probe body, then
2.
remove the end cap.
Page 23
Chapter 3 Maintenance and Repair
Strip with a modeling knife or other
tool, and separate solder joints.
Thermally shrunk
sleeving
Probe
Solder joints, then insulate
White or red
Insulating tape
Insulating tape
Enlarged view
Red
Blue
Shield
Tighten the pan-head screw until the head of the screw touches the probe shaft.
HIOKI 9455A980-04
Remove the thermally shrunk sleeving, and separate the two soldered joints.
3.
Take care not to damage the inner conductor.
7
First, pass the shielded wire through the probe body. Then, solder the shielded
4.
wire to the two lead wires connected to the 4-Terminal Probe with the end cap
installed.
The solder joints should be offset, to reduce the possibility of a short-circuit. Finally, reinforce the soldered portions with insulating tape or similar, to prevent short circuits.
Reassemble the 4-Terminal Probe (R-Arm), end cap.
5.
While pinching the end cap, turn the probe body to assemble them.
Finally fix the leads with the pan-head screw.
6.
Tighten the pan-head screw until the head of the screw touches the probe shaft. Do not
overtighten - doing so will tear the screw thread.
Refer to the "Names of Parts" (p.3) diagram, and check the connectivity of the banana
plugs and probe tips using a tester
connectivity function.
3
Page 24
8
HIOKI 9455A980-04
Chapter 4 Specifications
SpecificationsChapter 4
General Specifications
Operating
environment
Operating temperature
and humidity range
Storage temperature
and humidity range
DimensionsOverall length : Approx. 850 mm (33.46″)
WeightApprox. 100 g (3.5 oz.)
Option*1172-44 4-Terminal Probe (R-arm)
*: To order the option, please contact your authorized Hioki distributor or reseller.
Options are subject to change. Please check Hioki's website for the latest information.
Basic Specifications
Rated voltage
Indoor use, pollution degree 2, altitude up to 2000 m (6562 ft.)
0°C to 40°C (32°F to 104°F),
80% RH or less (non-condensing)
-10°C to 50°C (14°F to 122°F),
80% RH or less (non-condensing)
60 V DC or less
Page 25
HIOKI 9455A980-04
Page 26
HIOKI 9455A980-04
Page 27
HIOKI 9455A980-04
Page 28
www.hioki.co.jp/
HIOKI 9455A980-04
Loading...