Thank you for purchasing this HIOKI "9263 SMD TEST FIXTURE." To get the maximum performance from the unit, please read this manual first, and keep this at hand.
afety
This Instruction Manual provides information and notes essential for operating this equipment in a safe manner and for maintaining it in safe operating condition. Before using this equipment, be sure to carefully read the following safety notes.
CAUTIO
NOTE
presents possibility of injury to the user or damage to the equipment.
Denotes items of advice related to performance of the equipment or to its correct operation.
. Overview
This HIOKI 9263 SMD TEST FIXTURE can be directly connected to the measurement terminals (UNKNOWN) of the HIOKI LCR and Z HiTESTERs for testing a SMD component. The component can be clamped with a single knob action.
ixing leve
onnecting terminals
. Connecting the Test Fixture
Plug the fixture into the measurement terminals (UNKNOWN) of the tester, with the product name up.
Fasten it in place with the left and right fixing levers.
. Fixing the Samples
Put the sample (figure below) on the clamping portion, and clamp it by turning the knob.
NOTE
Samples whose width are 1 to 10 mm can be clamped.
Be careful to keep dirt away from the clamping portion.
Make sure the sample is firmly clamped. If not, accurate measurements cannot be obtained.
ample
. Open and Short Circuit Compensation
To enhance the accuracy of measurement, perform the open and short circuit compensation.
NOTE
The method of operation depends on the tester to which the test fixture is connected. Refer to the Instruction Manual for the tester.
Open circuit compensation
Turn the knob to open the high and low clamping portions (with no connection between the two ends of the clamping) in width of the sample to be measured.
Short circuit compensation
Turn the knob to short the high and low clamping portions.
. Specifications
Compatible instrument 3502, 3522, 3531 Measurement frequency DC to 5 MHz
range Maximum apply voltage ±40 V DC Widthofsampletobe 1to10mm
tested Residual resistance 5 mΩ max. (at 100 Hz)
(short-circuited) Floating capacitance 1 pF max. (at 5 MHz)
between terminals Dimensions 86(W)×22(H)×40(D) mm
Mass 100 g Operating temperature 0 to 40℃, 80% R.H. or less
and humidity range with no condensation Srorage temperature -10 to 55℃, 80%R.H. or less
and humidity range with no condensation Location for use Elevation of up to 2000 m
(excluding protrusions)
indoor
. Notes on Using the Test Fixture
Be careful to avoid dropping the unit or subjecting to other mechanical shock.
Do not use the unit in direct sunlight, dusty conditions, or in the presence of corrosive gases.
Gently wipe dirt from the surface of the unit with a soft cloth moistened with a small amount of water. Do not try to clean the unit using cleaners containing organic solvents such as benzine or thinners. They may cause discoloration or damage.
If the unit has gotten seriously wet, oily, or dusty, stop using it and send it for service at an approved HIOKI service facility.
For using the tester to which the test fixture is connected, refer to Instruction Manual of the tester.
CAUTIO
For applying a DC voltage, refer to the Instruction Manual of the tester.
ample
lamping portion
nob
emove
ix