ntroduction
Thank you for purchasing this HIOKI "9262 TEST
FIXTURE." To get the maximum performance from
the unit, please read this manual first, and keep this
at hand.
afety
This Instruction Manual provides information and
notes essential for operating this equipment in a
safe manner and for maintaining it in safe operating
condition. Before using this equipment, be sure to
carefully read the following safety notes.
Indicates that incorrect operation
CAUTIO
NOTE
presents possibility of injury to the
user or damage to the equipment.
Denotes items of advice related to
performance of the equipment or to
its correct operation.
. Connecting the Test Fixture
Plug the fixture into the measurement terminals
(UNKNOWN) of the tester, with the product name
up. Fasten it in place with the left and right fixing
levers.
. Open and Short Circuit Compensation
To enhance the accuracy of measurement, perform
the open and short circuit compensation.
NOTE
The method of operation depends on the tester to
which the test fixture is connected. Refer to the
Instruction Manual for the tester.
Open circuit compensation
Put the test fixture in the open-circuit state, with no
connection between the two ends of the clamping
slot.
Short circuit compensation
Use a shorting bar whose impedance is allow as
possible. If you use a metallic wire or the like as
a shorting bar, try to ensure that it is as thick and
short as possible.
ossible
. Specifications
Compatible instrument 3502, 3520, 3531
Measurement frequency 42 Hz to 5 MHz
range
Maximum apply voltage 40 V DC
Sample lead dimensions diameter 2 mm max.;
Residual resistance 5 mΩ max. (at 100 Hz)
(short-circuited)
Floating capacitance 2 pF max. (at 5 MHz)
between terminals
Dimensions 96(W)×26(H)× 33(D) mm
Mass 180 g
separation at least 5 mm
(excluding protrusions)
. Overview
This HIOKI 9262 TEST FIXTURE can be directly
connected to the measurement terminals
(UNKNOWN) of the 3502, 3520, or 3531 for testing a
lead component. The component can be clamped
with a single knob action.
ixing leve
nob
onnecting terminals
lamping slo
ample
. Fixing the Samples
Insert the sample (from above) into the clamping
slot, and clamp it by turning the knob.
NOTE
Samples whose leads differ in diameter by more
than 0.4 mm cannot be clamped.
Be careful to keep dirt away from the clamping
slot.
Make sure the sample is firmly clamped. If not,
accurate measurements cannot be obtained.
ample
emove
etallic plate
etallic wire
ot possible
Insert the shorting bar and clamp it, to short the
high and low test connections.
In order to keep external influences as low as
possible, be sure to thrust the shorting bar in all
the way.
. Notes on Using the Test Fixture
Be careful to avoid dropping the unit or subjecting
to other mechanical shock.
Do not use the unit in direct sunlight, dusty
conditions, or in the presence of corrosive gases.
If the unit has gotten seriously wet, oily, or dusty,
stop using it and send it for service at an approved
HIOKI service facility.
For using the tester to which the test fixture is
connected, refer to Instruction Manual of the
tester.