• The 3169-20/21 CLAMP ON POWER HiTESTER is supplied
with a instruction manual in addition to this manual. Please be
sure to read both manuals.
• This manual is a quick reference source with examples and information regarding the setting-up of and key operation for the
3169-20/21 CLAMP ON POWER HiTESTER for measurement
purposes.
• For current input with this device, a clamp-on sensor (optional) is
required. For details, refer to the instruction manual for the
clamp-on sensor you are using.
Safety Notes
The following symbols in this manual indicate the relative importance of cautions and warnings.
Indicates that incorrect operation presents an
extreme hazard that could result in serious injury or
death to the user.
Indicates that incorrect operation presents a significant hazard that could result in serious injury or
death to the user.
Indicates that incorrect operation presents a possibility of injury to the user or damage to the product.
Advisory items related to performance or correct
operation of the product.
1
2
3
4
5
6
7
8
Other Symbols
❖
*
Indicates the prohibited action.
Indicates the reference.
Indicates quick references for operation and reme-
dies for troubleshooting.
Indicates terminology explained at the bottom of
the page.
9
10
11
Quick Start Manual
2
3
Parts Names
❖4 "Connecting to Lines to be Measured" (page 35)
❖11 "Using D/A Output (3169-21 only)"
(page 157)
Recorder, logger
D/A output
(3169-21)
PC card
❖7.2 "Using a PC Card"
(page 117)
❖3 "Measurement Preparations"
(page 25)
*: The RS-232C is connected to a printer or PC.
The reference pages referred to above are those in the instruction
manual.
EXT I/O
RS-232C
1
❖10 "Using the External Input/
Output Terminal" (page 151)
❖9 "Using the Instrument with
a Computer" (page 145)
PC
Printer
❖8 "Using a Printer"
(page 137)
1
2
3
4
5
6
7
8
9
10
11
Quick Start Manual
4
1.1 Instrument Labels and Functions
1.1Instrument Labels and Functions
Front Panel
Display
5.7-inch STN LCD
Function (F1-F5) keys
Selects or switches the screens
and setting items.
Cursor key
These keys move the cursor on the screen.
1.1 Instrument Labels and Functions
5
1
Front Panel Enhanced View
MEASURE key
Switches to a screen that displays measurements.
SET UP key
Switches to a screen that displays settings.
FILE key
Used to work on files.
I RANGE key
Sets the current measurement range for the circuit
to be measured on-screen.
U RANGE key
Sets the voltage measurement range.
SAVE key
Enables the manual saving of measurement data
on the PC card or in internal memory. Manual saving is not possible during time-series measurement.
COPY key
Outputs screen image data to the PC card, internal
memory, or a printer.
START/STOP key
Starts or stops time-series measurements including
integration measurement.
2
3
4
5
6
7
8
9
START/STOP LED
Flashes in green while the instrument is standing by
for time-series measurement, and lights in green
while the instrument is performing time-series measurement.
10
11
Quick Start Manual
6
1.1 Instrument Labels and Functions
Top Panel
Left Panel
Voltage Input terminals
Connect the supplied 9438-03 VOLTAGE CORD.
Black Red Yellow Blue
NU1U2U
3
CH1 CH2 CH3 CH4
Current Input terminals
Connect an optional clamp-on sensor.
Contrast Control Knob
(CONTRAST)
Adjusts the contrast of the screen.
AC Power Inlet
Connects the power cord.
The supply voltage ranges
from 100 V to 240 V.
KEY LOCK switch
Sliding this switch in the direction of the
arrow disables all key operation except
the POWER switch.
POWER switch
Turns the instrument on and off.
: Power OFF
: Power ON
Right Panel
7
1.1 Instrument Labels and Functions
PC Card slot
A PC Card can be
inserted here.
Eject button
Press this button to eject a
PC Card from the slot.
Rear Panel
RS-232C Interface connector
Connects to a PC or printer using
an RS-232C cable.
D/A Output Terminal
(D/A OUT)
Installed in the 3169-21
only. Connects the supplied 9441 connection cable. Used for analog
output.
External Input/Output Terminal (EXT I/O)
Connects the optional 9440 connection cable.
Used to start and stop time-series measurement,
and control data storage on the PC card.
1
2
3
4
5
6
7
8
Number plate
Contains manufacturer’s ID
numbers. Please do not remove, as this information is
reguired for product management.
9
10
11
Quick Start Manual
8
1.2 Screen Names and Display Elements
1.2Screen Names and Display Elements
1.2.1Screen Configuration
The screens are divided into three basic types: measurement
screens, setting screens, and file screens. Each screen is selected
using three panel keys:
Measurement screen
MAIN
POWER
INTEGRATE
DEMAND
ZOOM
HARMONIC LIST
HARMONIC GRAPH
WAVEFORM
WIRING CHECK
WIRING DIAGRAM
MEASURE, SET UP
, and
FILE
.
File screen
INTERNAL SETTINGS
INTERNAL MEMORY
PC CARD
FIRMWARE UPDATE
Setting screen
MEASUREMENT
DATA OUTPUT
SAVE, PRINT ITEMS
SYSTEM
D/A OUTPUT
(3169-21 only)
Loading...