AvA
FR42873vbz
ASSEMBL Y INSTR U CTI O N S
The construction of this fixture will be accomplished by first assembling the main body
of the fixture, making all necessary electrical connections, hanging the fixture from the
ceiling and then installing the fixture shade.
SAFETY WARNING: Read wiring and grounding instructions [FRIS 18]
and any additional directions. Turn power supply off during installation. If new wiring
is required, consult a qualified electrician or local authorities for code requirements.
STEP 1
1
Slide the socket wires up through stem (A) and then thread the cluster assembly
(B) onto fixture rod (A) - See
Drawing 1.
STEP 2
1
Slide the glass (4) onto the cross bar (1) align screw holes, and slip screw (2)
through the screw holes in the crossbar (1) and shade mounting tab. Then thread
.
the cap (3) onto screw to secure shade.- See
Drawing 1
STEP 3
Refer to Hanging Instruction Sheet [FRIS19-41] to hang fixture. Then refer
back to this sheet to continue fixture installation.
STEP 4
Take the oval rings and hook them through the corresponding hooks on the
ceiling mount (a), then attach cage (d) by hooking the other end of the oval ring (c)
to the hook (d) on cage (e) . – See Drawing 3.
(c)
a
c
d
e

FRIS19-41
HANGING INSTRUCTIONS
SAFE TY WARNING: Read wiring and grounding instructions [FRIS 18]
and any additional directions. Turn power supply off during installation. If new wiring
is required, consult a qualified electrician or local authorities for code requirements.
[DRAWING 1]
b
STEP 1
1 Shut off electrical current before starting. If the fixture you are replacing is
turned on and off by a wall switch, simply turn the switch off. If not, remove the
appropriate fuse (or open the circuit breakers) until the fixture is dead.
• DO NOT restore current - either by fuse, breaker or switch - until the new
fixture is completely wired and in place.
STEP 2
1 Prepare mounting strap (a) by threading screws (b) into appropriately threaded hole
(h) - see Drawing 1. Make sure spacing of screws matches spacing of mounting holes
(3) in Canopy (c) -see Drawing 2.
2 Install mounting strap (a) to junction box (j), with two 8-32 screws (1) - see Drawing 2.
STEP 3
Make electrical connections from supply wire to fixture lead wires. Refer to
instruction sheet [FRIS18] and follow all instructions to make all necessary
wiring connections. Then refer back to this sheet to continue installation of
this fixture.
STEP 4
1 To mount fixture to ceiling , slip screws (b) in mounting strap (a) through
holes (3) in canopy (c) - see Drawing 2.
a
[DRAWING 2]
j
a
1
b
2 Hold canopy (c) up to ceiling and thread deocrative knobs (4) onto end of
screws (b) and tighten to secure fixture to ceiling.
3 Return to previous instruction sheet to complete fixture assembly.
2223
c
4
01.01.13

FRIS18
WIRING AND GROUNDING INSTRUCTIONS
SAFETY WARNING: Read wiring and grounding instructions
[FRIS 18] and any additional directions. Turn power supply off during installation. If new
wiring is required, consult a qualified electrician or local authorities for code requirements.
STEP 1 WIRING INSTRUCTIONS
Indoor Fixtures
1 Connect positive supply wire (a) (typically black or the smooth, unmarked side of
the two-conductor cord) to positive fixture lead (b) with appropriately sized twist
on connector - See Drawings 1 or 2.
2 Connect negative supply wire (c) (typically white or the ribbed, marked side of
the two-conductor cord) to negative fixture lead (d).
3 Please refer to the grounding instructions below to complete all electrical
connections.
Outdoor Fixtures
1 Connect positive supply wire (a) (typically black or the smooth unmarked side of
the two-conductor cord) to positive fixture lead (b) with appropriately sized twist
on connector - See Drawings 2 or 3.
2 Connect negative supply wire (c) (typically white or the ribbed, marked side of
the two-conductor cord) to negative fixture lead (d).
3 Cover open end of connectors with silicone sealant to form a watertight seal.
• If installing a wall mount fixture, use caulk to seal gaps between the fixture
mounting plate (backplate) and the wall. This will help prevent water from
entering the outlet box. If the wall surface is lap siding, use caulk and a fixture
mounting platform specially.
4 Please refer to the grounding instructions below to complete all electrical
connections.
STEP 2 GROUNDING INSTRUCTIONS
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (e) (typically copper or green plastic coated) to the fixture mounting strap
(1) with the ground screw (2) - See Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting
screws in strap.
Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (e) (typically copper or green plastic coated) under the
head of the ground screw (2) on fixture mounting strap (1) and connect to the
loose end of the fixture ground wire directly to the ground wire of the building
system with appropriately sized twist-on connectors - See Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (e) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal - See
Drawing 3.
supply wire
a c e
b
xture leads
supply wire
a c
b d
xture leads
supply wire
a c
d
b
xture leads
[drawing 1]
twist-on
d
connectors
[drawing 2]
twist-on
e
connectors
1
2
e
[drawing 3]
e
twist-on
connectors
e
1
2
1.30.08