![](/html/b4/b455/b455f2f869b5fd6264a3854c69cadcac6cab1eb3a8fac097c58e57420bc005be/bg1.png)
Drawing 1 - Fixture Mounting
A
D
C
assembly instructions
5470
Family: Plymouth Item No. 5470 OB
start here
J
1. Find a clear area in which you can work.
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
*** The construction of this fixture will be accomplished by first mounting the
mounting strap to the junction box, making all necessary electrical connections,
mounting the fixture to the wall, and then installing the glass.
E
Drawing 2 - Glass Installation
B
3
2
1
5
1. Prepare mounting strap (A) by threading 1-5/8” nipple
into the center hole of the mounting strap (A), approximately 1/4“.- see Drawing 1.
2. Attach mounting strap (A) to junction box (J) using two 1” screws (C) provided.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires. Refer to instruction
sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then
refer back to this sheet to continue installation of this fixture.
1. To mount fixture, slip center hole of backplate (E) over nipple (C) and hold fixture in
position.
2. Thread decorative knob (D) onto end of nipple (C) and tighten to secure fixture.
1. To install glass, remove threaded socket ring (3) from socket (1) - see Drawing 3.
2. Place glass (2) over exposed section of socket (1).
3. Thread socket ring (3) onto socket (1) to secure glass (2).
4. Fixture can now be lamped accordingly.
Note: Maximum wattage for 5470 fixture is 100 watts per bulb.
H I N K L E Y L I G H T I N G 1 2 600 B ere a Roa d Cle vela nd, OH 4 4111 8 00.4 46.5 539 / 21 6.67 1.33 00 w ww. h inkl e y lig htin g.co m
2.7.08