Place lockwasher (3) over end of tube (1) having the upset (2). Place end of tube, with upset, through
large hole of bottom body (4) (bottom body has eight of the largest arms attached to it) and out the small
bottom hole. Screw loop (5) on to end of tube. Be sure loop is tight!
Lower column (7) over tube (1) with wider/open end of column pointing toward bottom body (4).
Before resting column on bottom body, push wire connectors (6) together until you hear them click. Rest
column on bottom body; make sure bottom of column checks inside the large hole of the bottom body and
the top of the tube goes through the center hole in the top of the column.
Thread wire connector (8) through side hole, not center hole, in cap (9) and middle body (10)
(middle body has eight middle-sized arms attached to it). Stack the cap and body on top of column. Make
sure that top of tube (1) goes through center holesof cap and middle body.
Place lockwasher (11) inside body (10) over
13 17 top end of tube (1). Screw tube (13), with hex-coupler (12) on to
top end of tube (1). USE PLIERS TO TIGHTEN THIS
TUBE!
12 14 Make wire connection (14) between wire con- nector (8) and either one of the two connectors
11 coming from the middle body. Push connectors to- gether until you hear them click.
10 Turn large arms (15) 90 degrees so that the light sockets point up.
9 16 Turn medium arms (16) 90 degrees so that thelight sockets point up.
8 Go to other side...
7
1
6
2
3
4
15
5
Page 2
30
29
28
27
26
23
31
24
25
22
20
21
19
18
17
Lower column (18) over tube (13) with
wider/open end of column pointing down toward
middle body (10). Before resting column on body,
push wire connectors (17) together until you hear
them click. Rest column on middle body, making
sure that the column bottom checks inside the
large hole and the top of the tube (13) goes
through the top-center column hole.
Place lockwasher (19) over top of tube (13).
Screw tube (20), with hex hickey (21), on to
top end of tube (13). USE PLIERS TO TIGHTEN
TUBE!
Find the coiled piece of power supply wire
(22) provided with this fixture. One end has a wire
connector and one end doesn’t. Uncoil the wire
and push the end without a wire connector
through the hole in the hex-hickey (21) and UP
through the tube (20). When the end of the cord
comes up out of the top of the tube, pull that end
until there are about three inches of cord left
coming out of the hex-hickey hole.
Lower small body (23) over tube (20) so that
the large hole is facing down toward the column.
Before resting the body on the column, make two
wire connections. First, make the connection (25)
between the wire connector coming from the top
of the column and either one of the wire
connectors coming out of the small body. Push the
connectors together until you hear them click.
Second, make the connection (24) between the
power supply wire and the second wire connector
coming out of the small body. Push the connectors
together until you hear them click. Now you can
rest the small body on the column. Make sure that
the top of the column fits inside the large hole of
the small body.
Thread the power supply wire through the
open end of column (26) (large hole) and out the
small hole at the closed end. Lower the column
over the tube (20) and the small body (23). Make
sure that the open end of the column is facing the
small body and the end of the tube (20) goes
through the small hole at the top of the column.
Place one lockwasher (27) over the top of
the tube (20).
Place the groundwire ring (28) over the
lockwasher (27).
Place one lockwasher (29) over the top of
the groundwire ring (28).
Screw loop (30) on to top of tube (20).
TIGHTEN LOOP!
Turn small arms (31) 90 degrees so that the
light sockets point up.
Page 3
I.S.19 hanging instructions
I.S. 19
Drawing 1 - Hanging Assembly
A
1
2
3b
3a
B
6
weave supply wire and
C
ground wire through chain
start here
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
3c
GS
4
5
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
1. Shut off electrical current before starting. If the fixture you are replacing is
turned on and off by a wall switch, simply turn the switch off. If not, remove
the appropriate fuse (or open the circut breakers) until the fixture is dead.
• DO NOT restore current - either by fuse, breaker or switch - until the new
fixture is completely wired and in place.
1. fasten mounting strap (1) to outlet box (A) with the two 8-32 screws (2) -see
Drawing 1.
3. Thread one end of threaded tubing (4) into loop (5) a minimum of 1/2” to 3/4”.
Thighten hexnut (3a) against loop (5) to lock loop in position.
4. Thread other end of threaded tube (4) into mounting strap approximately 1/2”.
5. Slip canopy (B) over loop (5) and adjust height of loop so half of the threaded area
on the loop is exposed - see Drawing 2 below. After loop height is adjusted, thigten
hex nut (3b) up against mounting strap, tighten against mounting strap to lock loop
and threaded tube in position.
6. Remove mounting strap (1) from junction box (A), and thread third hex nut (3c) onto
end of threaded tube (4) above the mounting strap, tighten against mounting strap
to lock assembly in position.
7. Remount mounting strap to junction box.
1. Taking the chain, determine the length you require to hang the fixture.
2. Attach one end of the chain to the top loop of the fixture - see Drawing 2.
3. Now slip loop collar (5) and canopy (B) onto chain.
4. Attach other end of chain to loop (4). Get assistance for this step since fixture
may be heavy and difficult to hold while attaching the chain.
Drawing 2 - Canopy Adjustment
half of threaded area
exposed
HINKLEY LIGHTING 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com
1. Unwrap supply wire and ground wire and weave them up through the chain.
2. Slip supply wire and ground wire through center of loop (4).
3. Connect ground wire to mounting strap (1) using green ground screw (6).
4. Make electrical connections from supply wire to fixture lead wires. Refer to
instruction sheet (I.S. 18) and follow all instructions to make all necessary
wiring connections.
5. Slip canopy up firmly against the ceiling and secure by turning the threaded
collar (5) on loop (4) until tight.
Page 4
Drawing 1 - Flush Mount
supply wire
ACC
E
I.S. 18 wiring grounding instructions
I.S. 18
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
wiring instructions
Indoor Fixtures
B
fixture leads
Drawing 2 - Chain Hung
supply wire
connectors
twist-on
D
AC
twist-on
E
E
connectors
1
E
E
D
B
fixture leads
Drawing 3 - Post-Mount
supply wire
AC
2
E
twist-on
connectors
E
D
B
fixture leads
1
2
1. Connect positive supply wire (A)(typically black or the smooth, unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately
sized twist on connector - see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Please refer to the grounding instructions below to complete all
electrical connections.
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately
sized twist on connector - see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal.
• If installing a wall mount fixture, use caulk to seal gaps between the fixture
mounting plate (backplate) and the wall. This will help prevent water from
entering the outlet box. If the wall surface is lap siding, use caulk and a
fixture mounting platform specially.
4. Please refer to the grounding instructions below to complete all
electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1)
with the ground screw (2) - see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap.
Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the
head of the ground screw (2) on fixture mounting strap (1) and connect to the
loose end of the fixture ground wire directly to the ground wire of the building
system with appropriately sized twist-on connectors - see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power
supply ground with appropriately sized twist-on connector inside post. Cover open
end of connector with silicone sealant to form a watertight seal - see Drawing 3.