Hinkley Lighting 4928BN User Manual

Page 1
Drawing 1 - Assembly
C
assembly instructions
4928
Item No. 4928
B
A
1
2
3
4
Drawing 2 - Assembly
6
5
1. Find a clear area in which you can work.
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
*** The construction of this fixture will be accomplished by first assembling the main body of the fixture, making all necessary electrical connections, hanging the fixture from the ceiling and then installing the fixture shade.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
1. Slip center column (1) along wire and thread onto top of body (2) and tighten- see Drawing 1..
Note: It will be necessary to determine the length of rods you will require to hang your fixture at the desired height. After this has been established, please follow the instructions below.
2. Slip first rod section (B) along wire and thread into top of main fixture body (A).
3. Slip next section of rod (C) along wire and thread into top of previously installed
rod.
4. Continue adding sections of rod until all necessary length have been attached to the fixture.
5. Fixture can now be mounted to the ceiling by following mounting instruction sheet (IS19-81) provided.
6. After fixture is installed slip bottom cap (3) onto thread tube (D) and hold in position, and thread decorative ball (4) onto threaded tube (D) and tighten.
1. To complete assembly slip glass bobesche (6) over socket (5) - see Drawing 2.
2. Fixture can be lamped accordingly at this point, and power can be restored.
H I N K L E Y LIG H T I N G 33 00 0 Pin O ak P ar kway A vo n Lake, O H 44 012 80 0. 44 6.55 39 / 4 40.65 3. 55 00 hin kl ey li ghti ng .c om
1.1.13
Page 2
Drawing 1 - Fixture Assembly
C
I.S.19-81 hanging instructions
I.S. 19-81
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS ( IS-18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR
REQUIRMENTS.
A
S
R
E
F
G
D
1. Shut off electrical current before starting. If the fixture you are replacing is
turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circut breakers) until the fixture is dead.
DO NOT restore current - either by fuse, breaker or switch - until the new fixture is completely wired and in place.
B
1. In the following order : take retainer ring (L) , canopy (H) and slide them
over the stems (R) attached previously.
2. Thread supply wires (S) through center of swivel (E) that is attached to
mounting strap (A).
3. Slide swivel with mounting strap along wire and thread end of swivel
H
I
into top of stems (R).
4. Lift fixture and attach mounting strap (A) to junction box (C) using
2-8/32 screws (B).
5. Make all necessary electrical connections following instruction sheet
(IS-18) provided. Ground wire (D) can be attached to mounting strap (A)
using green ground screw (G).
6. Slip canopy (H) up along rods (R) and over mounting strap with swivel
and hold in position.
7. Slip retainer ring (I) up to canopy and thread onto coupler (F), to secure
canopy.
8. Return to assembly instructions to complete fixture construciton.
HINKLEY L IGHTI N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800. 44 6.55 39 / 440.653.5500 hinkleyligh ting.com
Page 3
Drawing 1 - Flush Mount
supply wire
A CC
E
I.S. 18 wiring grounding instructions
I.S. 18
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
wiring instructions
Indoor Fixtures
B
fixture leads
Drawing 2 - Chain Hung
supply wire
connectors
twist-on
D
A C
twist-on
E
E
connectors
1
E
E
D
B
fixture leads
Drawing 3 - Post-Mount
supply wire
A C
2
E
twist-on connectors
E
D
B
fixture leads
1
2
1. Connect positive supply wire (A) (typically black or the smooth, unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Please refer to the grounding instructions below to complete all electrical connections.
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
4. Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1) with the ground screw (2) - see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (2) on fixture mounting strap (1) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors - see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal - see Drawing 3.