3. Carefully review instructions prior to assembly.
2
1
Drawing 2 - Assembly
8
7
H
3
4
*** The construction of this fixture will be accomplished by first assembling the main
body of the fixture, making all necessary electrical connections, hanging the fixture
from the ceiling and then installing the fixture shade.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
1. Slip center tube (2) and slip over upset on top of main body (1) - see Drawing 1.
2. Slip center column (3) along wire and thread into coupler (4) located on top of
main body (1) and tighten.
Note: It will be necessary to determine the length of rods you will require to hang your
fixture at the desired height. After this has been established, please follow the
instructions below.
3. Slip first rod section (B) along wire and thread into top of main fixture body (A).
4. Slip next section of rod (C) along wire and thread into top of previously installed
rod.
5. Continue adding sections of rod until all necessary length have been attached to
the fixture.
6. Fixture can now be mounted to the ceiling by following mounting instruction sheet
(IS19-81) provided.
26
2
5
1. To assembly shade first slip candle sleeve, shade harp, and glass (7) over socket (6)
on main body (5) - see Drawing 2.
. Fixture should be lamped accordingly at this time.
3
. Slip ring (8) onto top of glass (7).
4. Thread tail piece (9) into bottom of arm.
9
H I N K L E Y L I G H T I N G 33 00 0 Pi n Oak Pa rk wa y Av on L ak e, OH 44 01 2 80 0. 44 6. 5539 / 44 0. 653.5 50 0 hink le yl ig ht ing. co m
1.1.13
Page 2
Drawing 1 - Fixture Assembly
I.S.19-81 hanging instructions
I.S. 19-81
J
B
A
swivel
R
start here
D
C
E
F
G
L
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
1. Shut off electrical current before starting. If the fixture you are replacing is
turned on and off by a wall switch, simply turn the switch off. If not, remove
the appropriate fuse (or open the circut breakers) until the fixture is dead.
• DO NOT restore current - either by fuse, breaker or switch - until the new
fixture is completely wired and in place.
1. In the following order: take retainer ring (I)
and slide them over the rods (R) attached previously.
2. Slip mounting plate with swivel (A) along wires and thread into top of rods (R).
3. Attach universal mounting strap (B) to the junction box (J) with screws (C).
4. Slip holes (E) in mounting plate with swivel (A) over screws (D) in universal mount-
ing strap (B).
5. Thread ball knobs (F) onto screws (D) to secure fixture to universal strap (B).
6. All necessary wiring can be done at this time. Please follow I.S. 18 for wiring
instructions.
7. Slip canopy (G) up along rods (R) and over mounting plate with swivel (A).
8. Slip retaining ring (L) up to canopy and thread onto coupler (K), located on the
mounting plate and swivel assembly, to secure parts.
9. Return to assembly instruction to complete assembly of this fixture.
canopy
(G)
H I N K L E Y L I G H T I N G12600 B er ea R oad Cl ev eland, O H 44 111 80 0. 446.5 53 9 / 216.6 71 .3 30 0 ww w.hi nk le yl ight in g. co m
Page 3
Drawing 1 - Flush Mount
supply wire
ACC
E
I.S. 18 wiring grounding instructions
I.S. 18
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)
AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING
INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED
ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
wiring instructions
Indoor Fixtures
B
fixture leads
Drawing 2 - Chain Hung
supply wire
connectors
twist-on
D
AC
twist-on
E
E
connectors
1
E
E
D
B
fixture leads
Drawing 3 - Post-Mount
supply wire
AC
2
E
twist-on
connectors
E
D
B
fixture leads
1
2
1. Connect positive supply wire (A)(typically black or the smooth, unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately
sized twist on connector - see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Please refer to the grounding instructions below to complete all
electrical connections.
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately
sized twist on connector - see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal.
• If installing a wall mount fixture, use caulk to seal gaps between the fixture
mounting plate (backplate) and the wall. This will help prevent water from
entering the outlet box. If the wall surface is lap siding, use caulk and a
fixture mounting platform specially.
4. Please refer to the grounding instructions below to complete all
electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1)
with the ground screw (2) - see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap.
Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the
head of the ground screw (2) on fixture mounting strap (1) and connect to the
loose end of the fixture ground wire directly to the ground wire of the building
system with appropriately sized twist-on connectors - see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power
supply ground with appropriately sized twist-on connector inside post. Cover open
end of connector with silicone sealant to form a watertight seal - see Drawing 3.
HINKLEY LIGHTING 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.