Hinkley Lighting 2075 User Manual

Page 1
assembly instructions
Item No. 2070 / 2074 / 2075
2070
2074
2075
Drawing 1 - Fixture Mounting
C
D
E
Drawing 2 - Glass Installation
door frame
A
B
J
1
2
3
start here (page 1)
1. Find a clear area in which you can work.
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
*** fixture will be accomplished by first, installing mounting hardware, making all necessary electrical connections, mounting fixture to wall, installing the mirror and candle sleeves, installing the glass, and then attaching the door.
1. Prepare mounting strap (A) by threading nipple into the center hole of the mount- ing strap (A), approximately 1/4“.- see Drawing 1.
2. Attach mounting strap (A) to junction box (J) using two screws (C) provided.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to continue installation of this fixture.
1. To mount fixture, slip center hole of backplate (E) over nipple (C) and hold fixture in
2
4
HINKLEY LIGHTING 33000 Pin Oak Parkway Avon Lake, Ohio 44012 800 446 5539 www.hinkleylighting.com
position - see Drawing 1.
2. Thread decorative knob (D) onto end of nipple (C) and tighten to secure fixture.
1. After mounting fixture to wall, install the side panels of glass (1) by sliding them through the front door frame, and placing them between the glass clips (2) and against the fixture frame - see Drawing 2.
2. Fold glass clips (2) up against glass to secure glass in fixture.
3. Proceed to page 2 of instruction sheets to complete fixture assembly.
01.01.13
Page 2
Drawing 3 - Glass Installation
assembly instructions
Item No. 2070 / 2074 / 2075
start here
2070
2074
2075
3
H
6
5
Drawing 4 - Door detail
L
1. Find a clear area in which you can work.
S
D
T
2
4
P
3
hinge
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
*** fixture will be accomplished by first, installing mounting hardware, making all necessary electrical connections, mounting fixture to wall, installing the mirror and candle sleeves, installing the glass, and then attaching the door.
1. After fixture is properly mounted to wall, slipped mirrored reflector (3) throught the door frame and behind the socket assembly (4) - see Drawing 3.
2. Slip center hole (H) in mirrored reflector (3) over mounting knob (D), and line up secondary holes (S) in mirrored reflector (3) with threaded holes (T) in back panel of fixture.
3. Thread ball knob with stud (5) into hole (T) in back panel of fixture to secure mirrored reflector (3). DO NOT use a tool to tighten part (5), over tightening could cause reflector damage.
4. Slip candle sleeve (6) over socket.
5. Fixture can be lamped accordingly at this time.
1. To complete fixture assembly it is necessary to attach the door (6) to the fixture.
2. Slip pin (P) out of door assembly (6) - see Drawing 4.
3. Place door on front of fixture and align door hinge and slip pin (P) back into place
to attach door.
4. Latch (L) can be slipped into lower part of latch on cage to lock door (6) shut.
5. Fixture assembly is completed and power can be restored.
01.01.13
6
HINKLEY LIGHTING 33000 Pin Oak Parkway Avon Lake, Ohio 44012 800 446 5539 www.hinkleylighting.com
Page 3
Drawing 1 - Flush Mount
supply wire
A CC
E
I.S. 18 wiring grounding instructions
I.S. 18
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
wiring instructions
Indoor Fixtures
B
fixture leads
Drawing 2 - Chain Hung
supply wire
connectors
twist-on
D
A C
twist-on
E
E
connectors
1
E
E
D
B
fixture leads
Drawing 3 - Post-Mount
supply wire
A C
2
E
twist-on connectors
E
D
B
fixture leads
1
2
1. Connect positive supply wire (A) (typically black or the smooth, unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Please refer to the grounding instructions below to complete all electrical connections.
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
4. Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1) with the ground screw (2) - see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (2) on fixture mounting strap (1) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors - see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal - see Drawing 3.
HINKLEY LIGHTING 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com
Page 4
1. After securing fixture to the wall it is recommended that the gap between the wall and the
fixture backplate be sealed with any good quality waterproof caulk or silicone sealant, on the top and sides leaving the bottom open as a weep hole.
(NOT INCLUDED) see Drawing 1.
start here---
I.S.200 Caulking Instruction____
Drawing 1
H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com