![](/html/a3/a3de/a3de69748422d4d86d33f88c0d21823a799017ed393efdc6668e5434c1fa2ef8/bg1.png)
The 1507QC is for use with SPT type
wire only. This connector is not for use
with the following models:
1507QC Quick Connect
1). Remove screw with Philips Head screw driver.
2). Seperate the two parts of the connector body.
3). Place pass through wire from transformer into
large area labeled
"Two Wire"
4). Place wire from fixture into the smaller area.
5). Place top over bottom and press downward.
The internal barbs will pierce both wires insulation
making electrical contact.
6). Replace screw to secure quick connector assembly.
.
3/4" Long Philips
Head Screw
1"
3/4"
Top of Connector has
internal barbs that cut
into wire insulation
2"
Connector Top
(wire barbs inside)
Connector Bottom
W
w
i
r
e
f
r
o
m
T
r
a
n
s
f
o
r
m
e
e
r
u
t
x
i
F
m
o
r
f
e
r
i
r
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF HINKLEY LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OFHINKLEY LIGHTING IS PROHIBITED.