SLIDING GATE OPENER CONTROL BOARD SL16XX USER MANUAL A7
I Safety Instruction
1. For security, please read instructions carefully before initial operation; making sure that the power is off before connection.
2. Please clear the memory before initial operation. (Ref.: Erasing ALL learned/memorized Transmitters
3. Do not learn the remote control when motor is operating in order to avoid mis-operation.
4. The received signal may be interfered by other communication devices. (e.g. the wireless control system with the same frequency range)
5. It is forbidden to control the high-risk coefficient equipment / system. (e.g. cranes)
endanger life or property during running failure, or its security risks have been eliminated.
7. It should be applied in dry indoor place or in the electric appliance place.
II Technical Index
1. Working voltage: 220VAC/110VAC50Hz/60HZ
2. Temperature range: -20 to 60
3. Loading capacity: 1HP, 250VAC
4. Built-in fuse: 10A, please exchange appropriate fuse according to loading capacity
5. Time of Soft-start & soft-stop: 4S/6S
6. Operation time: adjustable from 10S to 130S
7. Working frequency: 433.92MHz
8. Transmitters stored: 30 -300PCS
9. Size : 150*77*38
10. Weight301g
III Wire connection
IV Set up
4.1 Learning transmittersPress the learning button, LED is on, enters into the learning / memorizing transmitter process; Press the same button
twice, LED blinks for several times, then off. The learning process is successful. (Ignore this step if transmitter already matches the opener before
delivery):
4.2 Erasing transmitter: Press the learning button, continue pressing for 8s until LED turns off; Release learning button, L ED will be on (about 1s)
and then off; the erasing process is successful. (Ignore this step if transmitter already matches the opener before delivery)
4.3 Opening/closing limit adjustment: Remote control the door ( or move the door manually ) , adjust the position of limit device to make sure the
door would touch the limit switch when open or close the door .LED LD5/DL6 in the controller will be off when limit device touches limit switch
4.4 Running time/waiting time adjustment: « Adjust potentiometer T. Normal to change the running time (10-130s) of motor .Adjust it to make the
running time slightly longer (1-2s) than opening time that it needs. Adjust potentiometer T. Wait to change the time that between door opening to
auto-closing(10-130s).This function is available when DIP 1 is at ON position .
4.5 Photocell protection function test: Photocell connector connects the NC contact of photocell switch , DL7 LED turn on after t he connection, And
DL7 LED turn off when blocking out the transmit or receive signal of photocell artificially
4.6 DIP Switch set
As shown:
A: 【 1\2\3\4 】
For working voltage
220VAC\110VAC B:【5\6】Connector for flash lamp C: 8
Connector for motor common
port 1; 7
Connector for motor
running port 1; 9
Connector for
motor running port 2. D: 7/9
Connector for motor starting
capacitance.
As shown:
A:【12\13】
Connector for photocell
protection switch NC contact
B:【10\11】
24VAC output can power
supply the photocell.
C: If no need of using photocell,
make connector【12\13】
short circuit with terminated line(the connector is short circuit when leave factory)
As shown: DIP switch 2 in OFF position, connector 14\15\16
for
limit switch is Normal Open
As shown: DIP switch 2 in ON position, connector 14\15\16
for
limit switch is Normal Close
As shown: Connector
17\18\19\20\21
for external close/stop/open/loop control, control systems is the same as using transmitter
DIP2
ON
External limit NC switch
OFFExternal limit NO switch
DIP3
ON or OFF can change the current
operating direction of motor
(opener can be chosen to install on
DIP1
ON: Auto-close is effective
OF: Auto-close is off
DIP4
ON
Three button control
OF:Single button control
Page 2
V Operation Instruction
5.1 Three button control process (DIP 1 at ON position)
5.2 Single button control process (DIP 1 at OFF position)
Model
Frequency
Code
Transmitter stored
Voltage
Model
Frequency
Code
Transmitter stored
Voltage
SL1600
433.92Mhz
Rolling
30
220VAC
SL1620
433.92Mhz
Rolling
30
110VAC
SL1601
433.92Mhz
Rolling
300
220VAC
SL1621
433.92Mhz
Rolling
300
110VAC
SL1602
433.92Mhz
Fixed
60
220VAC
SL1622
433.92Mhz
Fixed
60
110VAC
SL1603
433.92Mhz
Fixed
600
220VAC
SL1623
433.92Mhz
Fixed
600
110VAC
The interpretation and ownership of this manual belong to Hiland company. Any change of the product can be without prior notice.
STOP
Press transmitter button 1
Press transmitter button 3
Open
limit
point
Press
transmitter
button 2
Close
limit
point
Photocell
protection
Press
transmitter
button 2
Max
running
time
Max
running
time
OPEN
CLOSE
Close
limit
Photocell
protection
Press
transmitter
button 1
Max
running
time
Press transmitter button 1
Open
limit
point
Press
transmitter
button 1
Max
running
time
OPEN
STOP
STOP
CLOSE
Description :
Single button control ,
press-open-press-stop-press-st
op; Only the learned button is effective in the transmitter,
original button is not effective any more when a new button has been learned in the same
transmitter (For example, button 1 was learned firstly,
button 2 or 3 has been learned
of the same transmitter afterwards , then button 1 was not effective any more)