Hidrotermal HIDRO-BPS075, HIDRO-BPS120, HIDRO-BPS100, HIDRO-BPS100H, HIDRO-BPS120H User Manual

...
-1-
HIDRO-BPS SERIES PUMP
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
1.READ AND FOLLOW ALL INSTRUC TIONS
2.WARNING To reduce the risk of injury. do not
3.WARNING Risk of Electrical Shock. Connected only to gro unding type receptacle protected by a ground fault circuit interrupter (GFCI). Contact a qualified electrician if you cannot verify that the re ceptacle is protected by GFCI.
4.CAUTION Do not bury cord. Locate cord to minimize abuse from lawnmowers, hedge trimmers, and other equipment.
5.CAUTION In case the running parts will injure people, don't make the electric pump running before then pipeline have been connected.
6.WARNING To reduce the risk of electrical shock, replace damaged cord immediately.
7.WARNING To reduce the risk of electrical shock, do not use extension cord to connect unit electric supply; provide a properly located outlet.
8.CAUTION Jetpump for je tted bathtubs, spapools, swimmingpools, massage tations, cleaning system.
9.Do not install within an outer encl-osure or
beneath the skirt of a hot tub unless so marked.
10. This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responĀ­sible person to ensure that they can use the appliance safely.
11.
12.FOR INDOOR USE ONLY.
13.SAVE THESE INSTRUCTIONS
This appliance can be used by children aged from 8 years and above if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and user mainĀ­tenance shall not be made by children unless they are older than 8 and above and supervised. Keep the appliance and its cord out of reach of children aged less than 8 years.
-Appliance can be used by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
-Children shall not play with the appliance.
SWIMMING POOL PUMP
USER MANUAL
1.General
These instructions are for correct installation, and optimum performance of the Bath pumps, so they should be read carefully. These are single-stage centrifugal pumps designed to operate with compact hydromassage equipment, They are equipped with a total-emptying system to prevent the discharge of residual liquid in each stopping.
O
These units are designed to operate with clean water at a maximum water temperature of 50 C.
Built of top quality materials, they are subjected to strict hydraulic and electrical controls and are carefully verified.
Correct installation is ensured by following these instructions and those of the wiring diagram; otherwise, over loads may be produced in the motor. We decline responsibility for any damage caused by not following these instructions..
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
-2-
2.lnstallation
3.Pipe Assembly
4.Electrical connection
EN60335-2-41
5.Controls Prior to Initial Start-up
6.Start-up
Performance curves
-3-
7.Maintenance and clean
Our pumps for hydromassage facilities do not require any special maintenance or programming. If the pump will be idle for a long period of time, it is recommended to disassemble, clean and store it in a dry, well-ventilated place. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person to a hazard. Pump can be automotive empty water after correct installation. When the pump needs to clean (1) filling with water up to level position of bathtub`s nozzle, (2) operating 2-3mimute,(3) exhausting water of bathtub after engine stop.
-Is the proper voltage applied to the pump?
-Is there an extension cord being used?
-Jets should be pointed away from the suction inlet so air is not forced into pump suction
-Is the in-tub suction inlet blocked or covered?
-Is there any debris in the pump housing?
-Is there a leak in the piping or the pump?
-incoming power to the pump?
-Is circuit breaker on?
-Is GFCI operating properly?
-Is the air switch plugged in?
NO POWER
TO PUMP
PUMP DOES
NO TURN
BLOCKAGE OR
LEAK
LOW VOLTAGE
PUMP NOT PUMPING PROPERLY
SYMPTOM
POSSIBLE CAUSE
CHECK
8.Trouble Shooting Guide
Head
0 50 100 150 200 250 300 350 400 450
0 3 6 9 12 15 1 8 21 24 2 7
0 20 40 6 0 80
0 20 40 60 80 100
20
16
12
8
4
0
30
25
20
15
10
5
0
60
50
40
30
20
10
0
H
(psi)H(m)
H
(ft)
HIDRO-BPS200(H)
HIDRO-BPS150(H)
HIDRO-BPS100(H)
HIDRO-BPS120(H)
U . S.GPM
IMP.GPM
3
m/h
l/min
Flow
HIDRO-BPS050
HIDRO-BPS075
-4-
V / Hz esp: See pump nameplate. Liquid temperature: 4 ~ 50
Storage temperature: -10 ~ Relativa Air Humidity: 95 Max.
+50 .
Installation diagram
Water pump
Stand filter
Vacuum hose
Vacuum head
Edition: 2017-06 a
520
170 211
225
1
G2 /
4
1
G2 /
4
331
225
308
142
159 238
390
340
17.5
12.5
0.75 1.0
1.51.1
3.8
5.8
470
18.5
1.5 2.0 7.0
HIDRO-BPS200(H)
48.5or50
Model
Fitting size (mm)
Amps
Qmax (l/min)
Hmax (m)
kW HP
Power(P1)
HIDRO-BPS150(H)
HIDRO-BPS120(H)
HIDRO-BPS100(H)
1.2
0.9 4.6
370
15
0.55 0.75
1.00.75
1.1
1.5
kW HP
Power(P2)
0.85
0.65
195
7
0.37 0.5
1.9
HIDRO-BPS075
HIDRO-BPS050
0.75
0.55 2.7
255
10
0.25 0.33
0.50.37
Loading...