Disclaimer: The V371 Fingerprint Reader, as sold, does not perform match-on-card functionality.
Match-on-card functionality may be covered by one or more patents owned by third parties, including US Patents RE43,333 and
RE44,034. The V371 should not be used to perform match-on-card functionality without first determining whether a license is needed
and obtaining such a license as appropriate.
1 System Requirements
The V371 Software supports the following operating systems: Microsoft Windows® 7/8 (64-bit)*, and Windows 7/8 (32-bit)*
*The Lumidigm Device Service 5.30.xx must be installed in order to run the V371 reader on the PC.
The V371 Demo and V371 Demo source code only supports MIFARE Classic 1K and MIFARE Classic 4K smart cards with default
MIFARE key values (0xFF 0xFF 0xFF 0xFF 0xFF 0xFF). The V371 Demo source code may be extended and modified to
support additional smart card types and key values.
Note: Windows XP is not ocially supported in this release. However, 32-bit Windows XP installers are provided for the
Lumidigm Device Service and the V31x device drivers. See the Lumidigm Install Guide v5.30.pdf for more information about
installing onto Windows XP.
2 Installation Instructions
1.Verify that the logged on user has full administrative privileges.
2.Verify that the User Account Control Settings are set to Default – Notify me only when programs try to make changes tomy computer. If not, right-click on the setup exe’s and select run as administrator.
3.Make sure you do not have the following Lumidigm sensors plugged into the system during the installation process.
• V31x, M31x, and V371
4.Uninstall any previous versions of the Lumidigm Device Service.
• If you have version 5.10.32, 5.10.33 or 5.10.34 installed, uninstall the Lumidigm Device Service Packages v5.10.3x.
Note: DO NOT uninstall Lumidigm Device Service Win 7/8 v5.10.3x program. Uninstalling the packages will remove
this program automatically.
• If you are on version 5.00.17 or earlier, uninstall the Lumidigm Device Service Win 7/8 vX.XX.XX where XX.XX.XX is
your version.
5.Run the LumidigmDeviceServicePackagesSetup_5.30.xx .exe setup (required for the fingerprint scanner embedded in the
V371 reader). To download the most recent software package, see:
• This installer will install the required Windows service and device drivers for the V31x and M31x sensors.
Note: If you uninstall the LumidigmDeviceServicePackages, the V31x and M31x device drivers will also be uninstalled.
This installer only supports Windows 7/8 (32 and 64 bit).
6.Run the Lumidigm V371 VCOM_32-bit_5.30.xx.exe. This installer will install the Lumidigm VCOM Integration Kit along with
the V371 Demo source code and compiled V371 Demo.
7.Plug the HID Global Lumidigm V371 Fingerprint Reader into the PC.
• The device drivers for the card reader should load automatically
• The device drivers for the fingerprint scanner should load automatically
• In the Device Manager, the smart card reader should now display as OMNIKEY 5x21 under the Smart card readers
group. If it does not display, right-click the device, and select Update Driver Software.
• In the Device Manager, the fingerprint scanner should display as a Lumidigm V31x Fingerprint Reader under the
Lumidigm Biometric Sensor group.
8.Run the compiled version. See the User Guide and Section 2: Installation Instructions for more information.
• The compiled version of the V371 demo is installed in C:\Program Files (x86)\HID Global\Lumidigm Release v5.30.
xx\VCOM-Integration-Kit\bin\install\V371Demo.exe.
Note: This can be run from the Start menu > All Programs > HID Global > Lumidigm Release v5.30.xx > VCOM
Integration Kit 32-bit > V371 Demo.
9.Build the V371 source code. See Section 4: Build the V371 Demo Source Code.
Note: When a smart card is inserted into the card reader slot of the V371, smart card Plug and Play detection may not work as
expected. You may receive a windows message stating that the driver software was not installed correctly. The smart card will
work as expected in this situation – even with this message. If this message needs to be suppressed, follow these instructions to
disable smart card plug and play in the local group policy. Make sure that this is the correct course of action for your deployment.
From Microsoft: http://technet.microsoft.com/en-us/library/dd979547%28v=ws.10%29.aspx
Each time a smart card is inserted in the computer, Windows attempts to download and install the smart card driver if it is not
already available on the computer. You may see a Plug and Play error when you insert a non-Plug and Play smart card on the
computer. This does not necessarily mean that there is a problem with the smart card.
If your deployment uses only non-Plug and Play smart card solutions, smart card Plug and Play can be disabled by a local
administrator on a client computer. Disabling smart card Plug and Play prevents smart card drivers, also known as smart card
mini-drivers, from downloading and prevents smart card Plug and Play prompts.
3 To Disable Smart Card Plug and Play in Local Group Policy
1.On a client computer, click Start.
2.Enter gpedit.msc in the Search programs and files box, and press Enter.
3.In the console tree under Computer Configuration, click Administrative Templates.
4.In the details pane, double-click Windows Components, and Double-click Smart Card.
5.Right-click Turn on Smart Card Plug and Play service, and click Edit.
6.Click Disabled.
7.Click OK, and reboot system for changes to take eect (Reboot may be required)
For enterprise deployments, smart card Plug and Play can be disabled by deploying a Group Policy. For information about
administrative templates, see Administrative templates overview for GPMC (http://go.microsoft.com/fwlink/?LinkId=152390).
4 Build the V371 Demo Source Code
1.The solution and project files are Visual Studio 2005. You may need to convert to your version of Visual Studio and make
additional changes for the source code to work.
2.Open the V371Demo solution file located in C:\Program Files (x86)\HID Global\Lumidigm Release v5.30.xx \VCOM-Integration-Kit\SampleCode\V371Demo\Build.
3.Set the V371Demo project as the StartUp project.
4.Set the working directory to ..\..\..\bin or “C:\Program Files (x86)\HID Global\Lumidigm Release v5.30.xx \VCOM-Integration-Kit\bin. Note: Be sure to build as Win32.
5 V371 Demo Overview
The HID Global Lumidigm V371 Demo provides an insight into the enrollment and verification capabilities of the HID Global
Lumidigm V371 using a MIFARE Classic 1K and MIFARE Classic 4K Smart cards. The application is a simple MFC C++ GUI
program developed using Visual Studio 2005. The application utilizes the Lumidigm VCOM API to interface with the fingerprint
sensor (HID Lumidigm V310 Sensor) and communicates with the smart card reader (HID OMNIKEY CardMan 5x21-CL) using the
Microsoft PC SC API.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
CAUTION: Any changes or modifications to this devise not explicitly approved by the manufacturer could void your authority to operate this equipment.
Canada Radio CeRtiFiCation
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Ce MaRking
HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/CE.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e outras condições da diretiva 1999/5/EC.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC.
Download copies of the R&TTE Declaration of Conformity (DoC) at http://www.hidglobal.com/certifications.
HID Global
Americas & Corporate
611 Center Ridge Drive
Austin, TX 78758
USA
Support: 866-607-7339
Fax: 949-732-2120
Asia Pacific
19/F 625 King's Road
North Point, Island East
Hong Kong
Support: 852-3160-9833
Fax: 852-3160-4809
Avis de non-responsabilité: Le V371 lecteur d'empreintes digitales, tel qu'il est vendu, ne prend pas en charge la fonctionnalité Match
On Card.
La fonctionnalité Match On Card est possiblement couverte par un ou plusieurs brevets détenus par des tierces parties, dont les
brevets américains RE43,333 et RE44,034. Le V371 ne doit pas être utilisé pour exécuter la fonctionnalité Match On Card sans qu'il
soit d'abord déterminé si une licence est nécessaire et sans l'obtention d'une telle licence, le cas échéant.
1 Configuration requise
Le logiciel du V371 prend en charge les systèmes d'exploitation suivants:
•Microsoft Windows 7/8 (64 bits)*
•Microsoft Windows 7/8 (32 bits)*
*Lumidigm Device Service 5.30.xx doit être installé afin de pouvoir lancer le lecteur V371 sur l'ordinateur.
La version démo du V371 et le code source de la version démo du V371 prennent uniquement en charge les cartes à puce
MIFARE Classic 1K et MIFARE Classic 4K avec les valeurs de clé MIFARE par défaut (0xFF 0xFF 0xFF 0xFF 0xFF 0xFF). Le
code source de la version démo du V371 peut être étendu et modifié afin de prendre en charge d'autres types de cartes à puce
et d'autres valeurs de clé.
Note: Windows XP n'est pas ociellement pris en charge dans cette version. Des programmes d'installation pour Windows XP
32 bits sont cependant fournis pour Lumidigm Device Service et pour les pilotes de périphérique du V31x. Consultez le fichier
Lumidigm Install Guide v5.30.pdf pour plus d'informations sur l'installation sur Windows XP.
2 Instructions d'installation
1.Vérifiez que l'utilisateur connecté dispose de tous les privilèges d'administration.
2.Vérifiez que les Paramètres de contrôle de compte d'utilisateur sont réglés sur Par défaut. M'avertir uniquement quanddes programmes tentent d'apporter des modifications à mon ordinateur. Sinon, cliquez avec le bouton droit de la souris
sur le fichier setup.exe et sélectionnez «Exécuter en tant qu'administrateur».
3.Assurez-vous que les capteurs Lumidigm suivants ne sont pas connectés à votre système pendant l'installation.
• V31x, M31x et V371
4.Désinstallez toute version précédente de Lumidigm Device Service.
• Si la version 5.10.32, 5.10.33 ou 5.10.34 est installée sur votre système, désinstallez Lumidigm Device Service Packages
v5.10.3x.
Note: NE PAS désinstaller le programme Lumidigm Device Service Win 7/8 v5.10.3x . Ce programme sera supprimé
automatiquement lors de la désinstallation des packages.
• Si vous utilisez la version 5.00.17 ou une version antérieure, désinstallez Lumidigm Device Service Win 7/8 vX.XX.XX
where XX.XX.XX est le numéro de votre version.
5.Exécutez le fichier d'installation LumidigmDeviceServicePackagesSetup_5.30.xx .exe (nécessaire pour le scanneur
d'empreintes digitales intégré dans le lecteur V371). Pour télécharger le logiciel le plus récent, voir:
• Le programme d'installation installera les services Windows et les pilotes de périphérique pour les capteurs V31x et
M31x.
Note: Si vous désinstallez les packages Lumidigm Device Service, les pilotes de périphérique V31x et M31x seront
également désinstallés. Ce programme d'installation ne prend en charge que Windows 7/8 (32 and 64 bits).
6.Exécutez le fichier V371 VCOM_32-bit_5.30.xx.exe. Ce programme d'installation installera le kit d'intégration Lumidigm
VCOM ainsi que le code source de la version démo du V371 et la version démo compilée du V371.
7.Connectez le lecteur d'empreintes digitales HID Global Lumidigm V371 à l'ordinateur.
• Les pilotes de périphérique pour le lecteur de cartes devraient être chargés automatiquement.
• Les pilotes de périphérique pour le scanneur d'empreintes digitales devraient être chargés automatiquement.
• Dans le Gestionnaire de périphériques, le lecteur de cartes à puce devrait maintenant être affiché sous le nom
OMNIKEY 5x21 dans le groupe Lecteurs de cartes à puce. S'il n'apparaît pas, cliquez avec le bouton droit de la souris
sur le périphérique, puis sélectionnez l'option Mettre à jour le pilote.
• Dans le Gestionnaire de périphériques, le scanneur d'empreintes digitales devrait maintenant être affiché sous le
nom Lumidigm V31x Fingerprint Reader dans le groupe Lumidigm Biometric Sensor.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
Page 3
hidglobal.comAn ASSA ABLOY Group brand
INSTALLATION GUIDE
8.Exécutez la version compilée. Pour plus d'informations, voir le guide de l'utilisateur et la Section 2: Instructions
d'installation.
• La version compilée et la version démo du V371 sont installées sous C:\Program Files (x86)\HID Global\Lumidigm
Release v5.30.xx\VCOM-Integration-Kit\bin\install\V371Demo.exe.
Note: Le programme peut être lancé depuis le menu suivant: Start> All Programs > HID Global > Lumidigm Release
v5.30.xx > VCOM Integration Kit 32-bit > V371 Demo.
9.Compilez le code source du V371. Voir la Section 4: Compiler le code source de la version démo du V371.
Note: Lorsque vous insérez une carte à puce dans la fente du lecteur de cartes V371, il est possible que la détection Plug-andPlay de cartes à puce ne fonctionne pas comme prévu. Il est possible que vous receviez un message Windows vous signalant
que le pilote n'a pas été installé correctement. Dans ce cas, la carte à puce ne fonctionnera pas comme prévu, même avec ce
message. Si ce message doit être supprimé, suivez ces instructions pour désactiver la fonction Plug-and-Play de cartes à puce
dans la stratégie de groupe locale. Assurez-vous qu'il s'agit de la bonne mesure pour la mise en œuvre de votre système.
Pour Microsoft: http://technet.microsoft.com/en-us/library/dd979547%28v=ws.10%29.aspx
Chaque fois qu'une carte à puce est insérée dans l'ordinateur, Windows tente de télécharger et d'installer le pilote de cartes à
puce si celui-ci n'est pas déjà disponible sur l'ordinateur. Il est possible qu'une erreur de Plug-and-Play survienne lorsque vous
insérez une carte à puce non Plug-and-Play dans l'ordinateur. Cela ne signifie pas nécessairement qu'il y a un problème avec la
carte à puce.
Si votre système n'utilise que des solutions de cartes à puce non Plug-and-Play, la fonction Plug-and-Play pour cartes à puce
peut être désactivée par un administrateur local sur un ordinateur client. La désactivation de la fonction Plug-and-Play pour
cartes à puce empêche le téléchargement des pilotes de cartes à puce, également connus sous le terme de minipilotes, ainsi que
l'achage d'invites Plug-and-Play pour cartes à puce.
3 Désactiver la fonction Plug-and-Play pour cartes à puce dans la stratégie de groupe
locale.
1.Sur un ordinateur client, cliquez sur Démarrer.
2.Entrez gpedit.msc dans le champ Rechercher les programmes et fichiers, puis appuyez sur Entrée.
3.Dans l'arborescence de la console apparaissant sous Configuration ordinateur, cliquez sur Modèles d'administration.
4.Dans le volet de détails, double-cliquez sur Composants Windows.
5.Double-cliquez sur Carte à puce.
6.Cliquez avec le bouton droit de la souris sur Activer le service Plug-and-Play de la carte à puce.
7.Cliquez sur Modifier.
8.Cliquez sur Désactivé.
9.Cliquez sur OK.
10. Redémarrez le système pour que les changements prennent eet (le redémarrage peut être nécessaire)
Pour la mise en œuvre de systèmes en entreprise, la fonction Plug-and-Play pour cartes à puce peut être désactivée à l'aide
d'une stratégie de groupe. Pour plus d'informations sur les modèles d'administration, voir la page Vue d'ensemble des modèles
d'administration pour GPMC (http://go.microsoft.com/fwlink/?LinkId=152390).
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
Page 4
hidglobal.comAn ASSA ABLOY Group brand
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.