HID Global SDC1000 User Manual

MOTOROLA
SDC1000
MOTOROLA SDC1000
SINGLE DOOR ACCESS CONTROLLER
- 1 -
MOTOROLA
SDC1000
CONTENTS
SINGLE DOOR ACCESS CONTROLLER
1. Important Safety Instructions
2. General
3. Features
4. Specifications
5. Name of the Parts
6. Identifying supplied parts
7. Installation of the Product
8. Wire Color Table of the Main Unit
9. Wire Connection in of basic application
10. Initial Setup
11. Operation
12. Setting Changes
13. FCC REGISTRATION INFORMATION
14. Warranty and Service
- 2 -
MOTOROLA
SDC1000
SINGLE DOOR ACCESS CONTROLLER
1. Important Safety Instructions
When using your door access controller, basing safety precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons including following:
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the product
3. Do not use liquid cleaners, or aerosol cleaners. Use a damp cloth for cleaning. if necessary, use a mild soap.
4. Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.
5. This product should be operated only from the type of power source indicated on the marking label. if you are not sure of the type of power supply to your home, consult your dealer or local power company.
6. Never push objects of any kind into this product though the cabinet slots as they may touch voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product.
7. To reduce the risk of electric shock, do not disassemble this product, but take it to a qualified serviceman when some service or repair work is required. Opening or removing covers may expose you to dangerous voltages or other risks. incorrect reassembly can cause electric shock when the appliance is subsequently used.
8. Unplug this product from the wall outlet and refer to qualified service personnel under the following conditions: a. When the power supply cord or plug is damaged or frayed. b. If liquid has been spilled into the product c. If the product has exposed to rain or water. d. If the product doses not operate normally by following the operating instructions. Adjust only those controls, that are covered by the operating instructions. Improper adjustment of other controls in damage and will often require extensive work by a qualified technician to restore the to normal operation.
e. If the product exhibit a distinct change in performance.
2. General
SDC1000 is an intelligent one door Access Controller based on powerful 8 bit Microprocessor to meet a simple and cost-effective access control market requirement. User friendly device allows you to register max. 128 USER IDs and easy to add or delete USER RFIDs. There are 5 inputs to connect EXIT Button, door contact, PIR sensor , Fire sensor and extra and you can program related output sources and activate timing from the front keypads. System will make alarm in case of number of times wrong entry and Temper switch opens and one TTL output can be connected to Auto-dialer (option) will make a call to the pre-defined phone numbers (max 4ch) and report the alarm to Police, Fire station and/or to your cellular phone by voice message. All event transaction report to the computer by RS232C communication. The modern design and easy installation will provide you an accurate access control for single door and 3 LED indicators informs you all system operating at real time. SDC1000 will give you field proven reliability and cost-effective solution anywhere the access controls and high security is required.
3. Features
- One door Access Controller
- Powerful dual 8 bit Microprocessors
- Built-in 4” Proximity Reader
- 128 USER Access RFIDs including one Master RFID
- Independant 5 inputs and 4 outputs including 2 output Relays
- All I/Os and activating Times user front programmable
- Door Lock and Unlock function
- Setting for Safe/Secure mode
- Numbers of Try-out error Alarm
- RS232 communication port for remote control and events report
- 3 LEDs for system operation status
- Modern design and easy operation
- 3 -
MOTOROLA
SDC1000
SINGLE DOOR ACCESS CONTROLLER
4. Specification
.CPU : Dual 8 bit Microprocessors .Memory : 8 KB Program memory 512 bytes Flash memory .User PIN numbers : 128 User RFIDs including one Master RFID .Proximity Reader : Built-in 4” Proximity reader .Input/Output : 5 Inputs max. rating at DC 12V/20mA
: 2 Relay outputs : DC12V/2A : 1 chime bell output : 5V/150mA ,
: 1 TTL output : 5V/20mA .Communication : One RS232C port, 9600 Baud Rate,N,8,1 .Keypads : 12 Numeric Keypads .LED : 3 LEDs(RED, GREEN, YELLOW) .Power : DC 12V/ 200mA .Operating Environment : 0°C to +60°C, 10% to 90% Humidity .Reset : Power ON Reset
5. Name of each part
SDC1000 Main Unit
6. Identifying supplied parts
Please unpack and check the contents of the box.
Main Unit Wall Mount O-Ring Instructions (1 EA) (1 EA) (5 EA) (1 EA)
- 4 -
MOTOROLA
SDC1000
7. Installation of the Product
7-1. Drill two 6-32 holes and one 1/2" hole on the proper location of the wall.
(If the gang box is already installed on the wall then skip this step.) 7-2. Using 2 screws, install wall mount to the wall. 7-3. Insert 5 O-rings to the wall mount as indicated, then route the cable of the main unit through the center hole and push the main unit to wall mount to lock the main unit and make sure that the main unit is locked with wall mount.
SINGLE DOOR ACCESS CONTROLLER
* CAUTIONS *
When the main unit is once fixed to wall mount, the locking pins will tighten the main unit therefore the operation test of the main unit should be required prior to fix the main unit to wall mount. If the main unit has to be disassembled from the wall mount, then you need another
wall mount to be replaced as the locking pins of wall mount will be broken when the main unit detached from the wall mount.
- 5 -
MOTOROLA
SDC1000
8. Wire Color Table of the Main Unit
POWER
Power(DC 12V) +12V Red wire, Red with White stripe Power(DC 12V) 0V(GND) Black wire, Black with White stripe
OUTPUT
Door RELAY(2A) COM Gray wire with Red stripe Door RELAY(2A) NC Blue wire with White stripe Door RELAY(2A) NO White wire with Red stripe
Alarm RELAY(2A) COM White wire Alarm RELAY(2A) NC Purple wire with White stripe Alarm RELAY(2A) NO Purple wire
TTL Output TTL Orange wire with White stripe CHIME BELL Output BELL Brown wire with White stripe
INPUT
Exit Button EXIT Yellow wire with Red stripe Door Sensor CONTACT Green wire External Input #1 IN#1 Orange wire External Input #2 IN#2 Green wire with White stripe External Input #3 IN#3 Brown wire Extra Reader Input DATA0 Pink wire Extra Reader Input DATA1 Cyan wire
SINGLE DOOR ACCESS CONTROLLER
RS232C INTERFACE
RS232-TX TXD Grey wire RS232-RX RXD Blue wire RS232-GND GND Yellow wire
- 6 -
MOTOROLA
SDC1000
9. Wire connection for basic application
This connection can be changed for different applications.
SINGLE DOOR ACCESS CONTROLLER
- 7 -
MOTOROLA
SDC1000
SINGLE DOOR ACCESS CONTROLLER
9-1. Power Connection
Connect (+)wire of DC 12V power to Red wire and Red/White stripe wire and
connect Power GND(-)wire of DC 12V to Black wire and Black/White stripe wire.
. Door Lock connection
9-2
9-2-1 Connection of POWER FAIL SAFE: Door Lock
- Connect Door RELAY(COM),Grey/Red stripe wire to DC +12V.
- Connect (+)wire of Door Lock to Door RELAY(NC),Blue/White stripe wire.
- Connect (-)wire of Door Lock to Power GND(-) wire.
9-2-2 Connection of POWER FAIL SECURE Door Lock
- Connect Door RELAY(COM),Grey/Red stripe wire to DC +12V.
- Connect (+)wire of Door Lock to Door RELAY(NO),White/Red stripe wire.
- Connect (-)wire of Door Lock to Power GND(-) wire.
. Alarm Device connection
9-3
- Connect Alarm RELAY(COM),white wire to DC +12V.
- Connect (+)wire of Alarm Device to Alarm RELAY(NO),Purple wire.
- Connect (-)wire of Alarm Device to Power GND(-) wire.
9-4. Exit Button connection
- Connect one of the wire of Exit Button to Exit Button Input, Yellow/Red stripe wire.
- Connect the other wire of Exit Button to Power GND(-) wire.
(In case of using Normal Closing Contact for Exit Button then please make setting
change of ACTIVE level of Exit Button in section 8-20)
9-5. Door Contact sensor connection
- Connect Door Contact sensor(COM) wire to Door Contact Input, Green wire.
- Connect Door Contact sensor(NO) wire to Power GND(-) wire. (In case of using Normal Closing(NC) Contact for Door Contact sensor then please make setting change of ACTIVE level of Door Contact in section 8-21)
9-6. Auxiliary Input Device connection(Applied to AUX Input#1,#2,#3)
- Connect one wire of Auxiliary Input Device to AUX Input wire (Input#1 Orange, Input#2 Green/White stripe, Input#3 Brown wire).
- Connect the other wire of Auxiliary Input Device to Power GND(-) wire. (In case of using Normal Closing(NC) Contact for Auxiliary Input Device then please make setting change of ACTIVE level of AUX Input in section 8-17 ~ 8-19)
- 8 -