INSTALLATION GUIDE
iCLASS SE® Biometric/
iCLASS SE Display Reader
RKCL40, RPKCL40, RKCLB40
SRD MODEL: RPKCL40E, RKCLB40E
PLT-02738 A.0
Parts
1 - Reader and base plate assembly
1 - Installation guide
2 - Terminal connector
4 - M3.5 mm x 12 mm Phillips machine screw
4 - #6-32 x .375” Phillips self-tapping machine screw
4 - #6 x 1.5” Phillips sheet metal screw
3 - #6-32 x .4375” Spanner security screw, anti-tamper (black)
3 - #6-32 x .4375 Phillips security screw (black)
1 - Mounting Gasket
Recommended
• Cable, 6 conductor, 22 or 24 AWG [65 mm or 51 mm] Twisted Pair, Over-All Shield (Belden 3108A or equivalent) - RS-485 + power
• Cable, 6 to 9 conductor, 22 or 24 AWG [65 mm or 51 mm] Over-All Shield, (Alpha 1296C or equivalent) - Wiegand + power
• DC power supply
• Metal or plastic double-gang junction box
• Reader spacer when using metal junction boxes - see How to Order Guide
• Security tool (for spanner security screw, anti-tamper) HID 04-0001-03
Specifications
AVG
1
CURRENT
Maximum
2
AVG
PEAK
OPERATING
3
TEMPERATURE
-4° to 149° F
(-20° to 65° C)
14° to 122° F
(-10° to 50° C)
PRODUCT
RKCL40 923N
RPKCL40 923P
RKCLB40 924N 165mA 215mA 275mA
1
Standby AVG - RMS current draw without a card in the RF eld.
2
Maximum AVG - RMS current draw during continuous PIV card reads.
Not evaluated by UL.
3
Peak - highest instantaneous current draw during RF communication.
BASE PART
NUMBER
INPUT VOLTAGE
(VDC)
12VDC
Standby
150mA 185mA 250mA
hidglobal.com An ASSA ABLOY Group brand
CABLE LENGTH
Wiegand and RS-485
500 ft - 22 AWG (152 m)
300 ft - 24 AWG (91 m)
UL Reference Number Deciphering
Reader Colors: K = Black,
x
1
x2 Wiring: T = Terminal
x3 Communications: R = Module
UL REF
NUMBER
RPKCL40Ex
RKCLB40E
SRD
Model
RPKCL40E
1x2x3
x1x2x3RKCLB40E
INSTALLATION GUIDE
Installation
1 Mounting
Attach Backplate and Mounting Gasket to Junction Box.
Install gasket
Wall backplate
2 Wiring
Beeper
DRAIN
HOLD
+VDC
GPIO1
GP102
GND
OC/TMPR
DATA1/CLK
DATA2/DATA
RED
GPIO3
GPIO4
GRN LED
iCLASS SE Biometric/iCLASS SE Display
Junction box not
included.
Reverse Configuration Rotating the backplate
180° allows for placing the LCD display on left
and the reader on right.
See Section B Alternate Reader Assembly for
instructions, before proceeding to Section 2:
Wiring.
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
Mounting holes for US doublegang electrical boxes.
ATTENTION
Observe precautions for handling
Terminal Reader
(Terminal block and
module position varies)
GRN LED
Beeper
DRAIN
HOLD
+VDC
GND
RED
P1
GPIO1
GP102
OC/TMPR
DATA1/CLK
DATA2/DATA
GPIO3
GPIO4
P2
ELECTROSTATIC SENSITIVE DEVICES
Note: Previous iCLASS readers had reversed
RS-485 wiring ( P2-7 & P2-6 - A & B).
When upgrading, ensure proper connections
as dened below.
Pigtail Terminal Description Pigtail Terminal Description
Yellow P1-1 Beeper Input Red / Green P2-7 GPIO1 (RS232-T / RS485-FDX/HDX-A)
Orange P1-2 LED Input (GRN) Ta n P2-6 GPIO2 (RS232-R / RS485-FDX/HDX-B)
Black P1-3 Ground (RTN) Violet P2-5 *Open Collector Output / Tamper
Red P1-4 +VDC White P2-4 **Wiegand Data 1 / Clock
Drain P1-5 Unused Green P2-3 **Wiegand Data 0 / Data
Brown P1-6 LED Input (RED) Pink P2-2 GPIO3 (RS485-FDX-Z)
Blue P1-7 Hold Input Gray P2-1 GPIO4 (RS485-FDX-Y)
*Tamper Output - When activated, output synchronizes to ground (default).
**Dependent upon reader conguration. See the HTOG for Wiegand and Clock-in-Data congurations.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
hidglobal.com An ASSA ABLOY Group brand
INSTALLATION GUIDE
iCLASS SE Biometric/iCLASS SE Display
3 Attach to Backplate
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
Mount the Reader Assembly (Reader,
LCD Assembly, and reader backplate)
to the wall backplate.
4 Power & Testing
Standard Configuration: Slide Reader
Assembly towards the right to lock.
Alternate Configuration: Slide Reader
Assembly to the left to lock.
Install Security screws.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
hidglobal.com An ASSA ABLOY Group brand