Parts
1 - Reader and base plate assembly
2 - Terminal connector
4 - M3.5 mm x 12 mm Phillips machine screw
4 - #6-32 x .375” Phillips self-tapping machine screw
4 - #6 x 1.5” Phillips sheet metal screw
3 - #6-32 x .4375” Spanner security screw, anti-tamper (black)
3 - #6-32 x .4375 Phillips security screw (black)
1 - Mounting Gasket
Recommended
• Cable, 6 conductor, 22 or 24 AWG [65 mm or 51 mm] Twisted Pair, Over-All Shield (Belden 3108A or equivalent) - RS-485 + power
• Cable, 6 to 9 conductor, 22 or 24 AWG [65 mm or 51 mm] Over-All Shield, (Alpha 1296C or equivalent) - Wiegand + power
• DC power supply
• Metal or plastic double-gang junction box
• Reader spacer when using metal junction boxes - see How to Order Guide
• Security tool (for spanner security screw, anti-tamper) HID 04-0001-03
Specifications
AVG
1
CURRENT Maximum
2
AVG
PEAK
OPERATING
3
TEMPERATURE
-4° to 149° F
(-20° to 65° C)
14° to 122° F
(-10° to 50° C)
PRODUCT
RKCL40 923N
RPKCL40 923P
RKCLB40 924N 165mA 215mA 275mA
1
Standby AVG - RMS current draw without a card in the RF eld.
2
Maximum AVG - RMS current draw during continuous PIV card reads. Not evaluated by UL.
3
Peak - highest instantaneous current draw during RF communication.
BASE PART
NUMBER
INPUT VOLTAGE
(VDC)
12VDC
Standby
150mA 185mA 250mA
hidglobal.com An ASSA ABLOY Group brand
CABLE LENGTH
Wiegand and RS-485
500 ft - 22 AWG (152 m)
300 ft - 24 AWG (91 m)
UL Reference Number Deciphering
Reader Colors: K = Black,
x
1
x2 Wiring: T = Terminal
x3 Communications: R = Module
UL REF
NUMBER
RPKCL40Ex
RKCLB40E
SRD
Model
RPKCL40E
1x2x3
x1x2x3RKCLB40E
INSTALLATION GUIDE
Installation
1 Mounting
Attach Backplate and Mounting Gasket to Junction Box.
Install gasket
Wall backplate
2 Wiring
Beeper
DRAIN
HOLD
+VDC
GPIO1 GP102
GND
OC/TMPR DATA1/CLK DATA2/DATA
RED
GPIO3 GPIO4
GRN LED
iCLASS SE Biometric/iCLASS SE Display
Junction box not included.
Reverse Configuration Rotating the backplate 180° allows for placing the LCD display on left and the reader on right.
See Section B Alternate Reader Assembly for instructions, before proceeding to Section 2: Wiring.
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
Mounting holes for US double­gang electrical boxes.
ATTENTION
Observe precautions for handling
Terminal Reader
(Terminal block and
module position varies)
GRN LED
Beeper
DRAIN
HOLD
+VDC
GND
RED
P1
GPIO1
GP102
OC/TMPR
DATA1/CLK
DATA2/DATA
GPIO3
GPIO4
P2
ELECTROSTATIC SENSITIVE DEVICES
Note: Previous iCLASS readers had reversed
RS-485 wiring ( P2-7 & P2-6 - A & B).
When upgrading, ensure proper connections
as dened below.
Pigtail Terminal Description Pigtail Terminal Description
Yellow P1-1 Beeper Input Red / Green P2-7 GPIO1 (RS232-T / RS485-FDX/HDX-A)
Orange P1-2 LED Input (GRN) Ta n P2-6 GPIO2 (RS232-R / RS485-FDX/HDX-B)
Black P1-3 Ground (RTN) Violet P2-5 *Open Collector Output / Tamper
Red P1-4 +VDC White P2-4 **Wiegand Data 1 / Clock
Drain P1-5 Unused Green P2-3 **Wiegand Data 0 / Data
Brown P1-6 LED Input (RED) Pink P2-2 GPIO3 (RS485-FDX-Z)
Blue P1-7 Hold Input Gray P2-1 GPIO4 (RS485-FDX-Y)
*Tamper Output - When activated, output synchronizes to ground (default).
**Dependent upon reader conguration. See the HTOG for Wiegand and Clock-in-Data congurations.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.
© 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
hidglobal.com An ASSA ABLOY Group brand
INSTALLATION GUIDE
iCLASS SE Biometric/iCLASS SE Display
3 Attach to Backplate
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
Mount the Reader Assembly (Reader, LCD Assembly, and reader backplate) to the wall backplate.
4 Power & Testing
Standard Configuration: Slide Reader
Assembly towards the right to lock.
Alternate Configuration: Slide Reader Assembly to the left to lock.
Install Security screws.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.
© 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
hidglobal.com An ASSA ABLOY Group brand
INSTALLATION GUIDE
iCLASS SE Biometric/iCLASS SE Display
A Biometric Reader
Proper Usage
Ensure a good quality Contact:
• Do not press too hard
• Do not move during image acquisition
• Leave your finger on the sensor at least 2 seconds
• Do not slide or roll your finger across the sensor
Cleaning
For optimum performance, it is recommended that the user clean the bio-reader periodically.
The use of a dry cloth is recommended to clean the acquisition surface.
Caution: Acidic liquids, alcohol or abrasive materials are prohibited.
In order not to scratch the surface, remove all dust and residue with gentle movements.
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
Acquisition Surface
B Credential Presentation Best Practices
To ensure a successful read of a card:
1. Hold card between the thumb and index finger.
2. Present the card so that the index finger creates a spacing between the card and the reader face.
Do not place the card flat on the reader.
3. Place the card parallel to the reader form factor. Do not angle to the right or left
4. Place the card parallel to the reader face. Do not angle the card up or down from the reader face.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.
© 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
hidglobal.com An ASSA ABLOY Group brand
INSTALLATION GUIDE
iCLASS SE Biometric/iCLASS SE Display
E Alternate Reader Assembly
The following steps reconfigure the reader assembly to position the LCD Display component on the left side of theassembly.
1. Disassemble the Reader.
• Remove the Reader from the backplate.
• Carefully unplug the ribbon cable from the module in the back of the Reader. Caution: Do not pull on the ribbon cable as this may damage the connection to the connector.
• Remove the LCD Display from the backplate.
• Gently pull the ribbon cable through the backplate.
Reader Backplate
Ribbon cable
Standard Configuration
Reader LCD Display
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
Alternate Configuration
LCD Display Reader
Reader
2. Reassemble with the LCD Display on the left side of the assembly.
• Rotate the backplate so that the large cutout for the power cable is on the left
• Gently route the ribbon cable back through the backplate slots, as shown below
• Plug the ribbon cable back into the module (back of Reader) and ensure module is fully seated into the reader
• Attach the LCD Display to the backplate (this must be installed first, as the Reader will fit slightly over the LCD Display)
• Attach the Reader to the backplate (power cable must be threaded through the large square cutout on the backplate)
• Return to Section 2.
Ribbon cable
Reader Backplate
LCD Display
Test card
LCD Display
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.
© 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
hidglobal.com An ASSA ABLOY Group brand
Reader
INSTALLATION GUIDE
iCLASS SE Biometric/iCLASS SE Display
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
Regulatory
The final product, containing the modular transmitter must be labeled with its own FCC ID and IC ID. If the FCC & IC ID is not visible, when the module is installed inside another device, then the final assembly label must contain the FCC and IC ID numbers with a statement such as follows: “Contains Transmitter Module with FCC ID JQ6-ICLASSBTM and IC ID 2236B-ICLASSBTM”.
UL
Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended to be used with listed (UL294) control equipment. Suitable for outdoor use. Only Wiegand and RS-485 communications have been evaluated by UL.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Any changes or modifcations to this device not explicitly approved by the manufacturer could void your authority to operate this equipment.
Indala Prox products RP10EL, RP15EL, RP30EL, RP40EL and RPK40EL are certified for FCC, Canada Radio Certification and CE Marking only.
Canada Radio CeRtiFiCation
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Ce MaRking
HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/CE.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e outras condições da diretiva 1999/5/EC.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC.
Download copies of the R&TTE Declaration of Conformity (DoC) at http://www.hidglobal.com/certifications.
BRaziL
Compliance Statement
Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução 242/2000, e atende aos requisitos técnicos aplicados. Para maiores informações, consulte o site da ANATEL - www.anatel.gov.br
This product is homologated at ANATEL according to procedure regulated by Resolution 242/2000, and it complies with the applicable technical requirements. For more information, consult ANATEL website - www.anatel.gov.br
RF Warning Statement
Per Article 6 of Resolution 506, equipment of restricted radiation must carry the following statement in a visible location:
Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.
This equipment operates in secondary character, meaning it does not have the right of protection against harmful interference, even against those the same character, and it cannot cause any interference to systems operating in the primary character.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.
© 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
hidglobal.com An ASSA ABLOY Group brand
INSTALLATION GUIDE
Fabricante: HID Global Corporation
Modelo: iCLASS SE RK40E, multiCLASS RPK40E
Este produto esta aprovada pela Anatel, de acordo com os procedimentos regulamentados pela
Resolução nº 242/2000 e atende aos requisitos técnicos aplicados.
secundário, isto é, não tem direito a proteção
estações do mesmo tipo, e não pode causar
interferência a sistemas operando em caráter
iCLASS SE Biometric/iCLASS SE Display
iCLASS Keypad Readers
FOTO SELO ANATEL
“Este equipamento opera em caráter
contra interferência prejudicial, mesmo de
primário”
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
iCLASS Non-Keypad Readers
FOTO SELO ANATEL
Fabricante: HID Global Corporation
Modelo: iCLASS SE R10, multiCLASS RP10E, multiCLASS RP30E
iCLASS SE R40E, multiCLASS RP15E, multiCLASS RP40E
Este produto esta aprovada pela Anatel, de acordo com os procedimentos regulamentados pela
Resolução nº 242/2000 e atende aos requisitos técnicos aplicados.
“Este equipamento opera em caráter
secundário, isto é, não tem direito a proteção
contra interferência prejudicial, mesmo de
estações do mesmo tipo, e não pode causar
interferência a sistemas operando em caráter
primário”
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.
© 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
hidglobal.com An ASSA ABLOY Group brand
INSTALLATION GUIDE
iCLASS SE Biometric/iCLASS SE Display
RKCL40E, RPKCL40E, RKCLB40E
SRD Model: RPKCL40E, RKCLB40E
taiwan
According to “Administrative Regulations on Low Power Radio Waves Radiated Devices” Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to a approved low power radio-frequency devices. The low power radio-frequency devices shall not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act. The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.
Japan MiC
“ この装置は総務省の型式指定を受けています。” (総務省指定番号は第AC-xxxxx号です) 本製品は電波を使用したRFID 機器の読み取り・書き込み装置です。 そのため使用する用途・場所によっては、医療機器に影響を与える恐れがあります
SingapoRe
Complies with
IDA Standards
DA103548
koRean kCC
R10E, R15E, R30E, and R40E RP10E, RP15E, RP30E and RP40E
RK40E RPK40E
항목 규격
송신주파수
수신주파수
출력
전원
전파형식
발진방식
변조방식
RFID:13.56 MHz
RFID:13.56 MHz
RFID: 10m에서
47.544mv이하
DC 16.0V
A1D
X-tal
AM AM(13.56MHz), FSK(125kHz)
RFID:13.5607 MHz,
LPD:125 KHz
RFID:13.56 MHz,
LPD:125 KHz
RFID: 10m에서 47.544mv이하.
LPD:3 m 거리에서 500 /m이하
X-tal (13.56MHz)
Resonator(125kHz)
HID Global
Americas & Corporate
611 Center Ridge Drive Austin, TX 78758 USA Support: 866-607-7339 Fax: 949-732-2120
For additional oces around the world, see www.hidglobal.com corporate oces. HID Global Customer Support: www.hidglobal.com/support
Asia Pacific
19/F 625 King's Road North Point, Island East Hong Kong Support: 852-3160-9833 Fax: 852-3160-4809
Europe, Middle East & Africa
Phoenix Road Haverhill, Suolk CB9 7AE England Support: 55 11 5514-7100 Fax: 55 11 5514-7109
Equipment 8T29 ACC Control Reader
hidglobal.com An ASSA ABLOY Group brand
General Signaling Equipment
Loading...