HID Global ICLASSU90 User Manual

ACCESS flexibility.
U90 (U90.915 & U90.865) Reader
®
iCLASS SE
INSTALLATION GUIDE
Ultra High Frequency
iCLASS SE
U90 (U90.915 & U90.865)

Parts List

Parts
1 - iCLASS Reader
1 - Installation Guide
2 - #6-32 x .375” Phillips machine screws
2 - #6-32 x .375” Spanner security screw, anti-tamper
2 - 7-pin Terminal connectors
1 - 10-pin Terminal connector
1 - Mounting Gasket
1 - Back Box
recommended
• Cable, 5-9 conductor (Wiegand or clock-and-data)
• Linear DC Power supply
• Metal or plastic junction box
• Security Tool (for anti-tamper screw) HID 04-0001-03
• Drill with various bits for mounting hardware
• Mounting Hardware
PLT-01545, A.0
Specifications
Standby
1
AVG
CURRENT
Max
2
AVG
PEAK
OPERATING
TEMPERATURE
3
-30° to 150° F
(-35° to 65° C)
CABLE LENGTH
Power Supply Lines
40 ft (12 m) - 22 AWG 100 ft (30 m) - 18 AWG
Communication Lines
Wiegand / Clock-and-Data
500 ft (152 m) - 22 AWG
RS-485
4,000 ft (1,219 m) - 24 AWG
UL Reference Number Deciphering
x1 Reader Colors: K = Black
x2 Wiring: T = Terminal
x3 Communications: N = No Module
UL REF
NUMBER
U90Ax1x2x
PRODUCT
U90 960N
BASE PART
NUMBER
INPUT
VOLTAGE (VDC)
12 VDC 320mA 400mA 1.0 A
24 VDC 160mA 200mA 0.5 A
1
Standby AVG - RMS current draw without a card in the RF eld.
2
Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL.
3
Peak - highest instantaneous current draw during RF communication.

Relays

Three (3) each dry relays for operating external audio and visual indicators. Not to be used for Access Control. Rated 30VDC, 2A resistive.
3
INSTALLATION GUIDE
2
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
Loading...
+ 4 hidden pages