HID Global ICLASSU90 User Manual

Page 1
ACCESS flexibility.
U90 (U90.915 & U90.865) Reader
®
iCLASS SE
INSTALLATION GUIDE
Ultra High Frequency
Page 2
iCLASS SE
U90 (U90.915 & U90.865)

Parts List

Parts
1 - iCLASS Reader
1 - Installation Guide
2 - #6-32 x .375” Phillips machine screws
2 - #6-32 x .375” Spanner security screw, anti-tamper
2 - 7-pin Terminal connectors
1 - 10-pin Terminal connector
1 - Mounting Gasket
1 - Back Box
recommended
• Cable, 5-9 conductor (Wiegand or clock-and-data)
• Linear DC Power supply
• Metal or plastic junction box
• Security Tool (for anti-tamper screw) HID 04-0001-03
• Drill with various bits for mounting hardware
• Mounting Hardware
PLT-01545, A.0
Specifications
Standby
1
AVG
CURRENT
Max
2
AVG
PEAK
OPERATING
TEMPERATURE
3
-30° to 150° F
(-35° to 65° C)
CABLE LENGTH
Power Supply Lines
40 ft (12 m) - 22 AWG 100 ft (30 m) - 18 AWG
Communication Lines
Wiegand / Clock-and-Data
500 ft (152 m) - 22 AWG
RS-485
4,000 ft (1,219 m) - 24 AWG
UL Reference Number Deciphering
x1 Reader Colors: K = Black
x2 Wiring: T = Terminal
x3 Communications: N = No Module
UL REF
NUMBER
U90Ax1x2x
PRODUCT
U90 960N
BASE PART
NUMBER
INPUT
VOLTAGE (VDC)
12 VDC 320mA 400mA 1.0 A
24 VDC 160mA 200mA 0.5 A
1
Standby AVG - RMS current draw without a card in the RF eld.
2
Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL.
3
Peak - highest instantaneous current draw during RF communication.

Relays

Three (3) each dry relays for operating external audio and visual indicators. Not to be used for Access Control. Rated 30VDC, 2A resistive.
3
INSTALLATION GUIDE
2
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
Page 3
PLT-01545, A.0 iCLASS SE
U90 (U90.915 & U90.865)
1
Mounting
200
100 75
EU
JBOX
75
100
200
VESA
CONDUIT
US
JBOX
EU
JBOX
EU
JBOX
US
JBOX
JBOX
75
EU
75
Mounting holes need to be drilled to mate with the mount selected for the site.
There are many options for mounting surfaces (pole, concrete, metal, wall bracket, etc.). See the iCLASS SE U90 Reader User Guide for detailed information.
200
100
100
200
Modify the gasket to the match the large holes on the mounting plate and to match the area between the mount and the box, to create a seal against the elements (see below).
Trim Gasket to match the contact area
Attach the box with the gasket to the mount
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
INSTALLATION GUIDE
3
Page 4
iCLASS SE
U90 (U90.915 & U90.865)
PLT-01545, A.0
2
Wiring
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
Terminal Description Terminal Description Terminal Description
P1-1 Beeper Input (BEEP) P2-1 GPIO4 (RS485-Y / TXA) P3-1 Earth Ground
P1-2 LED Input (GRN) P2-2 GPIO3 (RS485-Z / TXB) P3-2 Normally Closed (NC) - Relay 1
P1-3 Ground (GND) P2-3 ** Wiegand Data 0 / Data (DATA0/DATA) P3-3 Common (COM) - Relay 1
P1-4 +VDC P2-4 ** Wiegand Data 1 / Clock (DATA1/CLK) P3-4 Normally Open (NO) - Relay 1
P1-5 Unused (DRAIN) P2-5 * Open Collector Output / Tamper (OC/TMPR) P3-5 Normally Closed (NC) - Relay 2
P1-6 LED Input (RED) P2-6 GPIO2 (RS232-R / RS485-RXB) P3-6 Common (COM) - Relay 2
P1-7 Hold Input (HOLD) P2-7 GPIO1 (RS232-T / RS485-RXA) P3-7 Normally Open (NO) - Relay 2
P3-8 Normally Closed (NC) - Relay 3
P3-9 Common (COM) - Relay 3
P3-10 Normally Open (NO) - Relay 3
* Tamper Output - When activated, output synchronizes to ground (default).
** Dependent upon reader conguration. See the HTOG for Wiegand and Clock-in-Data congurations.
INSTALLATION GUIDE
4
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
Page 5
PLT-01545, A.0 iCLASS SE
U90 (U90.915 & U90.865)
3
4
Turn power on
Install Reader to Backbox
Power & Testing
Basic test of a card
LED is under the trap door
LED will be red (under the trap door)
LED will be Green Note: This is tested with a card mounted in a vehicle and driven by the reader.

Configurable Features

Open Collector Output - Controls an external device (16 VDC Max) operating in Host Mode only. Sink - 40mA / Source - 1mA. See the iCLASS Application Note for details.
• Optical Tamper - Reader is configurable for Optical Tamper. Once activated, and when the reader is removed from the mounting box, the Optical Tamper is activated. Contact HID Technical Support
for Optical Tamper options. See iCLASS SE U90 User Guide.
• Hold Input - when asserted, this line either buffers a card or disables a card read until released, as configured.
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
INSTALLATION GUIDE
5
Page 6
UL
Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended to be used with listed (UL294) control equipment.
Only Wiegand and RS-485 communications have been evaluated by UL.
CAUTION: Any changes or modifcations to this devise not explicitly approved by the manufacturer could void your authority to operate this equipment.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interfer­ence received, including interference that may cause undesired operation.
FCC RF Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna
Canada Radio Certification
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
CE Marking
HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/CE.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e outras condições da diretiva 1999/5/EC.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC.
Download copies of the R&TTE Declaration of Conformity (DoC) at http://www.hidglobal.com/certifications.
ACCESS experience.
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
HID GLOBAL, HID, the HID logo, and iCLASS SE, are the trademarks or registered trademarks of HID Global Corporation, or its licensors, in the U.S. and other countries.
HID Global
Americas & Corporate
611 Center Ridge Drive Austin, TX 78753 USA Support: 866 607 7339 Fax: 949 732 2120
For additional oces around the world, see www.hidglobal.com corporate oces. HID Global Customer Support: support.hidglobal.com
Asia Pacific
19/F 625 King’s Road NorthPoint, Island East Hong Kong Support: 852 3160 9833 Fax: 852 3160 4809
Europe, Middle East & Africa
Phoenix Road Haverhill, Suolk CB9 7AE England Support: +44 1440 711 822 Fax: +44 1440 714 840
Equipment 8T29
ACC Control READER
hidglobal.com
US Patents: See www.hidglobal.com/patents
Check reader label for current regulatory
PLT-01545 A.0
approvals.
Brazil
Condomínio Business Center St. Ermano Marchetti, 1435 Galpão A2 CEP 05038-001 Lapa - São Paulo/SP Brazil Support: 55 11 5514-7100
General Signaling Equipment